{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,5,2]],"date-time":"2026-05-02T06:32:08Z","timestamp":1777703528867,"version":"3.51.4"},"reference-count":44,"publisher":"SAGE Publications","issue":"2","license":[{"start":{"date-parts":[[2019,7,25]],"date-time":"2019-07-25T00:00:00Z","timestamp":1564012800000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/journals.sagepub.com\/page\/policies\/text-and-data-mining-license"}],"content-domain":{"domain":["journals.sagepub.com"],"crossmark-restriction":true},"short-container-title":["Journal of Intelligent &amp; Fuzzy Systems"],"published-print":{"date-parts":[[2019,9,9]]},"abstract":"<jats:p>\u00a0Accurate and fast islanding detection of distributed generation is extremely important for its effective operation in distribution systems. For this purpose, several islanding detection methods have been suggested. Among them, hybrid islanding detection techniques are preferred due to their minimum effects on the power system. However, hybrid islanding detection techniques also suffer from two main limitations. They still degrade the power quality and also take comparatively large time to detect the islanding phenomenon. Thus, fast detection and power quality degradation issues are still not solved by hybrid islanding detection techniques. To address this issue, this paper suggests a new islanding detection technique based on rate of change of reactive power (ROCORP) and radial basis function neural network (RBFNN). The proposed technique uses ROCORP as the RBFNN input. The appropriate database of several islanding and non-islanding events is generated by performing the offline simulations on 26 Bus Malaysian distribution system for training the RBFNN. The simulation results shows that it can detects islanding and non-islanding events very fast without degrading the power quality of the system and is independent of threshold limitations.<\/jats:p>","DOI":"10.3233\/jifs-181849","type":"journal-article","created":{"date-parts":[[2019,7,26]],"date-time":"2019-07-26T12:27:29Z","timestamp":1564144049000},"page":"2169-2179","update-policy":"https:\/\/doi.org\/10.1177\/sage-journals-update-policy","source":"Crossref","is-referenced-by-count":4,"title":["A new islanding detection technique based on rate of change of reactive power and radial basis function neural network for distributed generation"],"prefix":"10.1177","volume":"37","author":[{"given":"Asad Ali","family":"Chandio","sequence":"first","affiliation":[{"name":"Department of Electrical Engineering, Quaid-e-Awam University of Engineering Science &amp; Technology, Nawabshah, Sindh, Pakistan"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"J.A.","family":"Laghari","sequence":"additional","affiliation":[{"name":"Department of Electrical Engineering, Quaid-e-Awam University of Engineering Science &amp; Technology, Nawabshah, Sindh, Pakistan"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Suhail","family":"Khokhar","sequence":"additional","affiliation":[{"name":"Department of Electrical Engineering, Quaid-e-Awam University of Engineering Science &amp; Technology, Nawabshah, Sindh, Pakistan"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Suhail Ahmed","family":"Almani","sequence":"additional","affiliation":[{"name":"Department of Electrical Engineering, Quaid-e-Awam University of Engineering Science &amp; Technology, Nawabshah, Sindh, Pakistan"}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"179","published-online":{"date-parts":[[2019,7,25]]},"reference":[{"key":"e_1_3_1_2_2","first-page":"1","volume-title":"2015 IEEE Power & Energy Society: IEEE;","author":"Azim R.","year":"2015","unstructured":"AzimR., ZhuY., SaleemH.A., SunK., LiF., ShiD., et al., A decision tree based approach for microgrid islanding detection. Innovative Smart Grid Technologies Conference (ISGT), 2015 IEEE Power & Energy Society: IEEE; 2015. pp. 1\u20135."},{"key":"e_1_3_1_3_2","doi-asserted-by":"crossref","unstructured":"BassoT. DeBlasioR. IEEE Smart Grid Series of Standards IEEE 2030 (Interoperability) and IEEE 1547 (Interconnection) Status: Preprint. National Renewable Energy Laboratory (NREL) Golden CO.; 2012.","DOI":"10.1109\/ISGT.2012.6175748"},{"key":"e_1_3_1_4_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.ijepes.2014.05.003"},{"key":"e_1_3_1_5_2","doi-asserted-by":"publisher","DOI":"10.1109\/GreenTech.2017.21"},{"key":"e_1_3_1_6_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.rser.2013.01.018"},{"key":"e_1_3_1_7_2","doi-asserted-by":"publisher","DOI":"10.1109\/60.969474"},{"key":"e_1_3_1_8_2","first-page":"95","volume-title":"Sixth International Conference on Developments in Power System Protection (Conf Publ No 434)","author":"Kane P.O.","year":"1997","unstructured":"KaneP.O. and FoxB., Loss of mains detection for embedded generation by system impedance monitoring, Sixth International Conference on Developments in Power System Protection (Conf Publ No 434) 1997. pp. 95\u201398."},{"key":"e_1_3_1_9_2","doi-asserted-by":"publisher","DOI":"10.1109\/TPWRD.2003.822964"},{"key":"e_1_3_1_10_2","first-page":"196","volume-title":"2006 PECon\u201906 IEEE International: IEEE;","author":"Singam B.","year":"2006","unstructured":"SingamB. and HuiL.Y., Assessing SMS and PJD schemes of anti-islanding with varying quality factor. Power and Energy Conference, 2006 PECon\u201906 IEEE International: IEEE; 2006. pp. 196\u2013201."},{"key":"e_1_3_1_11_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.enconman.2015.03.029"},{"key":"e_1_3_1_12_2","doi-asserted-by":"publisher","DOI":"10.1109\/TPWRD.2009.2013382"},{"key":"e_1_3_1_13_2","first-page":"225","volume-title":"2013 IEEE International Conference on: IEEE;","author":"Shi L.","year":"2013","unstructured":"ShiL. and WuF., An islanding detection algorithm based on fuzzy adaptive phase drift control. Information and Automation (ICIA), 2013 IEEE International Conference on: IEEE; 2013. pp. 225\u2013229."},{"key":"e_1_3_1_14_2","first-page":"1","volume-title":"2011 IEEE: IEEE;","author":"Mahat P.","year":"2011","unstructured":"MahatP., ChenZ. and Bak-JensenB., Review on islanding operation of distribution system with distributed generation. Power and Energy Society General Meeting, 2011 IEEE: IEEE; 2011. pp. 1\u20138."},{"key":"e_1_3_1_15_2","doi-asserted-by":"publisher","DOI":"10.1109\/ECCE.2013.6647411"},{"key":"e_1_3_1_16_2","doi-asserted-by":"publisher","DOI":"10.1049\/iet-rpg.2009.0019"},{"key":"e_1_3_1_17_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.rser.2014.04.026"},{"key":"e_1_3_1_18_2","doi-asserted-by":"publisher","DOI":"10.1109\/TPEL.2013.2263845"},{"key":"e_1_3_1_19_2","doi-asserted-by":"publisher","DOI":"10.1109\/TPEL.2010.2089643"},{"key":"e_1_3_1_20_2","doi-asserted-by":"publisher","DOI":"10.1049\/cp.2014.1469"},{"key":"e_1_3_1_21_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.rser.2013.08.025"},{"key":"e_1_3_1_22_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.enconman.2014.08.024"},{"key":"e_1_3_1_23_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.enconman.2013.07.033"},{"key":"e_1_3_1_24_2","doi-asserted-by":"publisher","DOI":"10.1109\/EPEC.2015.7379956"},{"key":"e_1_3_1_25_2","doi-asserted-by":"publisher","DOI":"10.1109\/IMCEC.2016.7867435"},{"key":"e_1_3_1_26_2","doi-asserted-by":"publisher","DOI":"10.1109\/TPWRD.2015.2406577"},{"key":"e_1_3_1_27_2","first-page":"2828","volume-title":"2015 IEEE International Conference on: IEEE;","author":"Kothari N.","year":"2015","unstructured":"KothariN. and FernandesB., A hybrid active islanding detection technique for single-phase inverter-based distributed generation system. Industrial Technology (ICIT), 2015 IEEE International Conference on: IEEE; 2015. pp. 2828\u20132834."},{"key":"e_1_3_1_28_2","doi-asserted-by":"publisher","DOI":"10.1109\/TPWRD.2009.2013376"},{"key":"e_1_3_1_29_2","doi-asserted-by":"publisher","DOI":"10.1080\/15325008.2012.682249"},{"key":"e_1_3_1_30_2","doi-asserted-by":"publisher","DOI":"10.1109\/TSTE.2016.2515158"},{"key":"e_1_3_1_31_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.epsr.2013.08.010"},{"key":"e_1_3_1_32_2","unstructured":"RostamiA. AbdiH. OlamaeiJ. NaderiE. and MoradiM. A new hybrid islanding detection technique using rate of change of frequency and real power with capacitor switching 2016."},{"key":"e_1_3_1_33_2","first-page":"2409","volume-title":"2007 ISIE 2007 IEEE International Symposium on: IEEE;","author":"Pigazo A.","year":"2007","unstructured":"PigazoA., MorenoV.M., LiserreM. and Dell\u2019AquilaA., Wavelet-based islanding detection algorithm for single-phase photovoltaic (pv) distributed generation systems. Industrial Electronics, 2007 ISIE 2007 IEEE International Symposium on: IEEE; 2007. pp. 2409\u20132413."},{"key":"e_1_3_1_34_2","doi-asserted-by":"publisher","DOI":"10.1109\/TPWRS.2006.887892"},{"key":"e_1_3_1_35_2","first-page":"1","article-title":"Islanding Detection of Hybrid Distributed Generation under Reduced Non-detection Zone","author":"Cui Q.","year":"2017","unstructured":"CuiQ., El-ArroudiK. and JoosG., Islanding Detection of Hybrid Distributed Generation under Reduced Non-detection Zone, IEEE Transactions on Smart Grid. 2017; pp. 1.","journal-title":"IEEE Transactions on Smart Grid."},{"key":"e_1_3_1_36_2","doi-asserted-by":"publisher","DOI":"10.1049\/iet-rpg.2016.0080"},{"key":"e_1_3_1_37_2","first-page":"1","volume-title":"2010 45th International: IEEE;","author":"Ghazi R.","year":"2010","unstructured":"GhaziR. and LotfiN., A new hybrid intelligent based approach to islanding detection in distributed generation. Universities Power Engineering Conference (UPEC), 2010 45th International: IEEE; 2010. pp. 1\u20135."},{"key":"e_1_3_1_38_2","first-page":"1","volume-title":"2012 IEEE: IEEE;","author":"Bitaraf H.","year":"2012","unstructured":"BitarafH., SheikholeslamzadehM., RanjbarA.M. and MozafariB., Neuro-fuzzy islanding detection in distributed generation. Innovative Smart Grid Technologies-Asia (ISGT Asia), 2012 IEEE: IEEE; 2012, pp. 1\u20135."},{"key":"e_1_3_1_39_2","doi-asserted-by":"publisher","DOI":"10.1080\/15325008.2010.526986"},{"key":"e_1_3_1_40_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.enconman.2013.12.062"},{"key":"e_1_3_1_41_2","doi-asserted-by":"publisher","DOI":"10.1049\/iet-gtd.2015.0069"},{"key":"e_1_3_1_42_2","article-title":"Deep learning hybrid method for islanding detection in distributed generation","author":"Kong X.","year":"2017","unstructured":"KongX., XuX., YanZ., ChenS., YangH. and HanD., Deep learning hybrid method for islanding detection in distributed generation, Applied Energy. 2017.","journal-title":"Applied Energy"},{"key":"e_1_3_1_43_2","article-title":"Hybrid Islanding Detection in Microgrid with Multiple Connection Points to Smart Grids using Fuzzy-Neural Network","author":"Kermany S.D.","year":"2016","unstructured":"KermanyS.D., JoorabianM., DeilamiS. and MasoumM.A., Hybrid Islanding Detection in Microgrid with Multiple Connection Points to Smart Grids using Fuzzy-Neural Network, IEEE Transactions on Power Systems. 2016.","journal-title":"IEEE Transactions on Power Systems"},{"key":"e_1_3_1_44_2","first-page":"18","article-title":"A Hybrid Multi-feature based Islanding Detection Technique for Grid Connected Distributed Generation","author":"Sareen K.","year":"2017","unstructured":"SareenK., BhaljaB.R. and MaheshwariR.P., A Hybrid Multi-feature based Islanding Detection Technique for Grid Connected Distributed Generation, International Journal of Emerging Electric Power Systems (2017), 18.","journal-title":"International Journal of Emerging Electric Power Systems"},{"key":"e_1_3_1_45_2","doi-asserted-by":"publisher","DOI":"10.1109\/TPEL.2004.833436"}],"container-title":["Journal of Intelligent &amp; Fuzzy Systems"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/journals.sagepub.com\/doi\/pdf\/10.3233\/JIFS-181849","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/journals.sagepub.com\/doi\/full-xml\/10.3233\/JIFS-181849","content-type":"application\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/journals.sagepub.com\/doi\/pdf\/10.3233\/JIFS-181849","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,4,29]],"date-time":"2026-04-29T09:38:54Z","timestamp":1777455534000},"score":1,"resource":{"primary":{"URL":"https:\/\/journals.sagepub.com\/doi\/10.3233\/JIFS-181849"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2019,7,25]]},"references-count":44,"journal-issue":{"issue":"2","published-print":{"date-parts":[[2019,9,9]]}},"alternative-id":["10.3233\/JIFS-181849"],"URL":"https:\/\/doi.org\/10.3233\/jifs-181849","relation":{},"ISSN":["1064-1246","1875-8967"],"issn-type":[{"value":"1064-1246","type":"print"},{"value":"1875-8967","type":"electronic"}],"subject":[],"published":{"date-parts":[[2019,7,25]]}}}