{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,2,5]],"date-time":"2026-02-05T09:46:53Z","timestamp":1770284813043,"version":"3.49.0"},"reference-count":21,"publisher":"SAGE Publications","issue":"6","license":[{"start":{"date-parts":[[2019,5,21]],"date-time":"2019-05-21T00:00:00Z","timestamp":1558396800000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/journals.sagepub.com\/page\/policies\/text-and-data-mining-license"}],"content-domain":{"domain":["journals.sagepub.com"],"crossmark-restriction":true},"short-container-title":["Journal of Intelligent &amp; Fuzzy Systems"],"published-print":{"date-parts":[[2019,6,11]]},"abstract":"<jats:p>\u00a0Distribution network operators have been generally engaged over the last few decades toward distribution system automation to enhance reliability and efficiency of power systems. From the viewpoint of reliability, optimal sectionalizing switch placement is an effective strategy since it mitigates both power network asset cost and number of customers not supplied by outages. From efficiency perspective, introducing capacitors and distributed generations (DGs) and DGs optimal sitting in power distribution systems with the goal of volt\/var control can reduce system loss and voltage deviation. In this regard, this paper proposes a methodology to determine the optimal location of sectionalizing switches and DG units while the concept of Volt\/Var control problem is also considered. The objective functions are formulated to enhance the network condition during normal and contingency conditions. A new enhanced sine cosine algorithm is proposed for providing the best compromise solution. A self-adaptive probabilistic mutation strategy is appended into the original algorithm to balance exploitation and exploration in order to achieve the promising search space and ultimately converge to the global or near-global optimum. A 33-bus IEEE test system is deployed to assess the superiority of the proposed framework.<\/jats:p>","DOI":"10.3233\/jifs-18631","type":"journal-article","created":{"date-parts":[[2019,5,24]],"date-time":"2019-05-24T10:53:30Z","timestamp":1558695210000},"page":"6605-6617","update-policy":"https:\/\/doi.org\/10.1177\/sage-journals-update-policy","source":"Crossref","is-referenced-by-count":4,"title":["Multi-Objective Coordination of Local and Centralized Volt\/Var Control with Optimal Switch and Distributed Generations Placement"],"prefix":"10.1177","volume":"36","author":[{"given":"Majid","family":"Saeidi","sequence":"first","affiliation":[{"name":"Department of Electrical and Electronic Engineering, Shiraz University of Technology, Shiraz, Iran"}]},{"given":"Taher","family":"Niknam","sequence":"additional","affiliation":[{"name":"Department of Electrical and Electronic Engineering, Shiraz University of Technology, Shiraz, Iran"}]},{"given":"Jamshid","family":"Aghaei","sequence":"additional","affiliation":[{"name":"Department of Electrical and Electronic Engineering, Shiraz University of Technology, Shiraz, Iran"}]},{"given":"Mohsen","family":"Zare","sequence":"additional","affiliation":[{"name":"Department of Electrical Engineering, Faculty of Engineering, Jahrom University, Jahrom, Iran"}]}],"member":"179","published-online":{"date-parts":[[2019,5,21]]},"reference":[{"key":"e_1_3_1_2_2","doi-asserted-by":"publisher","DOI":"10.1109\/TII.2016.2585379"},{"key":"e_1_3_1_3_2","doi-asserted-by":"publisher","DOI":"10.1109\/MPE.2009.934876"},{"key":"e_1_3_1_4_2","doi-asserted-by":"publisher","DOI":"10.1109\/TPWRS.2014.2312424"},{"key":"e_1_3_1_5_2","doi-asserted-by":"publisher","DOI":"10.1109\/TPWRS.2006.876673"},{"key":"e_1_3_1_6_2","doi-asserted-by":"publisher","DOI":"10.1109\/TPWRD.2004.838470"},{"key":"e_1_3_1_7_2","doi-asserted-by":"publisher","DOI":"10.1109\/TPWRD.2011.2119498"},{"key":"e_1_3_1_8_2","first-page":"1","article-title":"\u201cSwitch placement algorithm for reducing customers outage impacts on radial distribution networks,\u201d","author":"Bezerra J.R.","year":"2012","unstructured":"BezerraJ.R., BarrosoG.C., LeaoR.P.S., \u201cSwitch placement algorithm for reducing customers outage impacts on radial distribution networks,\u201d, in Proc. IEEE Region 10 Conf., pp. 1\u20136, Nov 2012.","journal-title":"in Proc. IEEE Region 10 Conf"},{"key":"e_1_3_1_9_2","doi-asserted-by":"publisher","DOI":"10.1109\/TPWRD.2007.905428"},{"key":"e_1_3_1_10_2","first-page":"1","article-title":"\u201cOptimal allocation of remote controlled switches in radial distribution systems,\u201d","author":"de Assis L.S.","year":"2012","unstructured":"de AssisL.S., GonzalezJ.F.V., UsbertiF.L., LyraC. and Von ZubenF., \u201cOptimal allocation of remote controlled switches in radial distribution systems,\u201d, in Proc. IEEE PES Gen Meet., pp. 1\u20138, Jul 2012.","journal-title":"in Proc. IEEE PES Gen Meet."},{"key":"e_1_3_1_11_2","doi-asserted-by":"publisher","DOI":"10.1109\/TPWRS.2008.926471"},{"key":"e_1_3_1_12_2","doi-asserted-by":"publisher","DOI":"10.1109\/TPWRD.2013.2244923"},{"key":"e_1_3_1_13_2","doi-asserted-by":"publisher","DOI":"10.1109\/TPWRD.2007.916112"},{"key":"e_1_3_1_14_2","doi-asserted-by":"publisher","DOI":"10.3233\/IFS-130892"},{"key":"e_1_3_1_15_2","doi-asserted-by":"publisher","DOI":"10.1109\/61.35652"},{"key":"e_1_3_1_16_2","doi-asserted-by":"publisher","DOI":"10.1109\/59.192914"},{"key":"e_1_3_1_17_2","doi-asserted-by":"publisher","DOI":"10.1109\/59.709114"},{"key":"e_1_3_1_18_2","first-page":"1","article-title":"Optimal sectionalizing switches and DG placement considering critical system condition","author":"Nematollahi M.","year":"2013","unstructured":"NematollahiM., TadayonM., Optimal sectionalizing switches and DG placement considering critical system condition. In Electrical Engineering (ICEE), 2013, 21st Iranian Conference, pp. 1\u20136, May 2013, 2013.","journal-title":"In Electrical Engineering (ICEE)"},{"key":"e_1_3_1_19_2","doi-asserted-by":"publisher","DOI":"10.1109\/TSG.2016.2609681"},{"key":"e_1_3_1_20_2","doi-asserted-by":"publisher","DOI":"10.1063\/1.4727920"},{"key":"e_1_3_1_21_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.knosys.2015.12.022"},{"key":"e_1_3_1_22_2","doi-asserted-by":"publisher","DOI":"10.1049\/iet-gtd.2017.1011"}],"container-title":["Journal of Intelligent &amp; Fuzzy Systems"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/journals.sagepub.com\/doi\/pdf\/10.3233\/JIFS-18631","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/journals.sagepub.com\/doi\/full-xml\/10.3233\/JIFS-18631","content-type":"application\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/journals.sagepub.com\/doi\/pdf\/10.3233\/JIFS-18631","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,2,4]],"date-time":"2026-02-04T19:52:12Z","timestamp":1770234732000},"score":1,"resource":{"primary":{"URL":"https:\/\/journals.sagepub.com\/doi\/10.3233\/JIFS-18631"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2019,5,21]]},"references-count":21,"journal-issue":{"issue":"6","published-print":{"date-parts":[[2019,6,11]]}},"alternative-id":["10.3233\/JIFS-18631"],"URL":"https:\/\/doi.org\/10.3233\/jifs-18631","relation":{},"ISSN":["1064-1246","1875-8967"],"issn-type":[{"value":"1064-1246","type":"print"},{"value":"1875-8967","type":"electronic"}],"subject":[],"published":{"date-parts":[[2019,5,21]]}}}