{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,5,2]],"date-time":"2026-05-02T06:38:05Z","timestamp":1777703885244,"version":"3.51.4"},"reference-count":29,"publisher":"SAGE Publications","issue":"4","license":[{"start":{"date-parts":[[2019,7,30]],"date-time":"2019-07-30T00:00:00Z","timestamp":1564444800000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/journals.sagepub.com\/page\/policies\/text-and-data-mining-license"}],"content-domain":{"domain":["journals.sagepub.com"],"crossmark-restriction":true},"short-container-title":["Journal of Intelligent &amp; Fuzzy Systems"],"published-print":{"date-parts":[[2019,10,25]]},"abstract":"<jats:p>To achieve superior harmonic reduction using hybrid energy generation high power devices interfaces, an advanced fuzzy current and voltage controlled technique is proposed in this paper. It proves that the proposed fuzzy controlled way could decrease the numbers of active and passive filters in the micro grid hybrid energy system. Furthermore, a closed control loop for wind system connected rectifier is not essential as the wind voltage and speed variation can be automatically recognized by the advanced control loop. Therefore, the advanced control architecture decreases the system complexity without affecting the system performance. Control and design of both the dc\/dc converter and three-phase inverter are presented. Moreover, the proposed scheme offers outstanding performance for overcoming the voltage and current distortions. The simulation model of the proposed system is developed in MATLAB Simulink environment and tested for the proposed control technique performance. Further, experimental results revealed the power and viability of the proposed method.<\/jats:p>","DOI":"10.3233\/jifs-190504","type":"journal-article","created":{"date-parts":[[2019,8,2]],"date-time":"2019-08-02T12:17:59Z","timestamp":1564748279000},"page":"5335-5350","update-policy":"https:\/\/doi.org\/10.1177\/sage-journals-update-policy","source":"Crossref","is-referenced-by-count":2,"title":["Flexible hybrid system power quality improvement using advanced control architecture"],"prefix":"10.1177","volume":"37","author":[{"given":"Iram","family":"Akhtar","sequence":"first","affiliation":[{"name":"Department of Electrical Engineering, Jamia Millia Islamia, New Delhi, India"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Sheeraz","family":"Kirmani","sequence":"additional","affiliation":[{"name":"Department of Electrical Engineering, Jamia Millia Islamia, New Delhi, India"}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"179","published-online":{"date-parts":[[2019,7,30]]},"reference":[{"key":"e_1_3_1_2_2","doi-asserted-by":"publisher","DOI":"10.1049\/iet-rpg.2016.0440"},{"key":"e_1_3_1_3_2","doi-asserted-by":"publisher","DOI":"10.1049\/iet-gtd.2015.0769"},{"key":"e_1_3_1_4_2","doi-asserted-by":"publisher","DOI":"10.1109\/TPEL.2015.2480407"},{"key":"e_1_3_1_5_2","doi-asserted-by":"publisher","DOI":"10.1109\/TIE.2015.2477061"},{"issue":"12","key":"e_1_3_1_6_2","first-page":"560","article-title":"Design of fuzzy neural network control for single-stage boost inverter","volume":"2","author":"Wai R.J.","year":"2015","unstructured":"WaiR.J. and LiuY.K., Design of fuzzy neural network control for single-stage boost inverter, Proc \u2013 Int Conf Mach Learn Cybern 2(12) (2015), 560\u2013565.","journal-title":"Proc \u2013 Int Conf Mach Learn Cybern"},{"key":"e_1_3_1_7_2","doi-asserted-by":"publisher","DOI":"10.1109\/TSG.2014.2309491"},{"key":"e_1_3_1_8_2","doi-asserted-by":"publisher","DOI":"10.1049\/iet-rpg.2014.0404"},{"key":"e_1_3_1_9_2","doi-asserted-by":"publisher","DOI":"10.1109\/TIE.2012.2186103"},{"key":"e_1_3_1_10_2","doi-asserted-by":"publisher","DOI":"10.1109\/TIE.2005.855652"},{"key":"e_1_3_1_11_2","doi-asserted-by":"publisher","DOI":"10.1109\/TII.2013.2290069"},{"key":"e_1_3_1_12_2","doi-asserted-by":"publisher","DOI":"10.1109\/TIE.2012.2209609"},{"key":"e_1_3_1_13_2","doi-asserted-by":"publisher","DOI":"10.1109\/TSTE.2013.2275939"},{"key":"e_1_3_1_14_2","doi-asserted-by":"publisher","DOI":"10.1109\/TIA.2005.861277"},{"key":"e_1_3_1_15_2","doi-asserted-by":"publisher","DOI":"10.1109\/TPEL.2012.2228280"},{"key":"e_1_3_1_16_2","doi-asserted-by":"publisher","DOI":"10.1109\/TSTE.2012.2214794"},{"key":"e_1_3_1_17_2","doi-asserted-by":"publisher","DOI":"10.1109\/TPEL.2013.2280600"},{"key":"e_1_3_1_18_2","doi-asserted-by":"publisher","DOI":"10.1109\/TPWRS.2013.2243765"},{"key":"e_1_3_1_19_2","doi-asserted-by":"publisher","DOI":"10.1109\/TIA.2013.2288430"},{"key":"e_1_3_1_20_2","first-page":"1","article-title":"Adaptive TS Fuzzy-Based MPC for DC Microgrids With Dynamic CPLs: Nonlinear Power Observer Approach","author":"Vafamand N.","year":"2018","unstructured":"VafamandN., YousefizadehS., KhoobanM.H., BendtsenJ.D. and DragicevicT., Adaptive TS Fuzzy-Based MPC for DC Microgrids With Dynamic CPLs: Nonlinear Power Observer Approach, IEEE Syst J (2018), 1\u20138.","journal-title":"IEEE Syst J"},{"key":"e_1_3_1_21_2","first-page":"1","article-title":"TS Fuzzy Model-Based Controller Design for a Class of Nonlinear Systems Including Nonsmooth Functions","author":"Vafamand N.","year":"2017","unstructured":"VafamandN., AsemaniM.H., KhayatiyanA., KhoobanM.H. and DragicevicT., TS Fuzzy Model-Based Controller Design for a Class of Nonlinear Systems Including Nonsmooth Functions, IEEE Trans Syst Man, Cybern Syst (2017), 1\u201312.","journal-title":"IEEE Trans Syst Man, Cybern Syst"},{"key":"e_1_3_1_22_2","doi-asserted-by":"publisher","DOI":"10.1109\/TIE.2018.2880666"},{"key":"e_1_3_1_23_2","doi-asserted-by":"publisher","DOI":"10.1109\/TIE.2018.2826485"},{"key":"e_1_3_1_24_2","first-page":"1","article-title":"Robust non-fragile Fuzzy Control of uncertain DC Microgrids Feeding Constant Power Loads","volume":"8993","author":"Vafamand N.","year":"2019","unstructured":"VafamandN., KhoobanM.H., DragicevicT., BlaabjergF. and BoudjadarJ., Robust non-fragile Fuzzy Control of uncertain DC Microgrids Feeding Constant Power Loads, IEEE Trans Power Electron 8993(c) (2019), 1\u20131.","journal-title":"IEEE Trans Power Electron"},{"key":"e_1_3_1_25_2","doi-asserted-by":"publisher","DOI":"10.1115\/1.4035240"},{"key":"e_1_3_1_26_2","doi-asserted-by":"publisher","DOI":"10.1109\/JESTPE.2017.2708815"},{"key":"e_1_3_1_27_2","doi-asserted-by":"publisher","DOI":"10.1109\/TIA.2018.2848959"},{"key":"e_1_3_1_28_2","doi-asserted-by":"publisher","DOI":"10.1109\/TIE.2011.2143373"},{"key":"e_1_3_1_29_2","doi-asserted-by":"publisher","DOI":"10.1109\/TIA.2013.2282494"},{"key":"e_1_3_1_30_2","doi-asserted-by":"publisher","DOI":"10.1109\/TPEL.2014.2362171"}],"container-title":["Journal of Intelligent &amp; Fuzzy Systems"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/journals.sagepub.com\/doi\/pdf\/10.3233\/JIFS-190504","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/journals.sagepub.com\/doi\/full-xml\/10.3233\/JIFS-190504","content-type":"application\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/journals.sagepub.com\/doi\/pdf\/10.3233\/JIFS-190504","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,4,29]],"date-time":"2026-04-29T09:39:53Z","timestamp":1777455593000},"score":1,"resource":{"primary":{"URL":"https:\/\/journals.sagepub.com\/doi\/10.3233\/JIFS-190504"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2019,7,30]]},"references-count":29,"journal-issue":{"issue":"4","published-print":{"date-parts":[[2019,10,25]]}},"alternative-id":["10.3233\/JIFS-190504"],"URL":"https:\/\/doi.org\/10.3233\/jifs-190504","relation":{},"ISSN":["1064-1246","1875-8967"],"issn-type":[{"value":"1064-1246","type":"print"},{"value":"1875-8967","type":"electronic"}],"subject":[],"published":{"date-parts":[[2019,7,30]]}}}