{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,1,31]],"date-time":"2026-01-31T04:53:52Z","timestamp":1769835232977,"version":"3.49.0"},"reference-count":27,"publisher":"SAGE Publications","issue":"1","content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["IFS"],"published-print":{"date-parts":[[2022,6,1]]},"abstract":"<jats:p>In the modern industrial process, a complete production process is achieved by requiring a variety of equipment to cooperate with each other. The abnormality in any equipment will have a large or small impact on process safety or product quality, resulting in increased risk. In recent years, many data-driven early-warning methods have been developed in academia. However, most of the methods need to be implemented on the support of normal and fault data. In order to overcome the problem, this paper establishes a new early-warning model based on negative selection algorithm (NSA) for centrifugal compressor unit without fault data. Firstly, a nearest neighbor fixed boundary negative selection algorithm (NFB-NSA) is proposed by optimizing detector generation mechanism and matching rules for test samples. Secondly, the performance of NFB-NSA is tested by Iris dataset. The experimental results among NFB-NSA, V-detector, and other anomaly detection methods for Iris dataset shows that NFB-NSA can achieve the highest detection accuracy and the lowest false alarm rate in most cases. Finally, the early-warning of centrifugal compressor unit under normal samples is carried on by NFB-NSA in this paper. Validated by field data, NFB-NSA is demonstrated to be of excellent accuracy and robustness by results of experiments. Moreover, the influence of size of training sample on performance of NFB-NSA is obtained.<\/jats:p>","DOI":"10.3233\/jifs-213075","type":"journal-article","created":{"date-parts":[[2022,1,18]],"date-time":"2022-01-18T15:30:57Z","timestamp":1642519857000},"page":"1065-1075","source":"Crossref","is-referenced-by-count":1,"title":["Nearest fixed boundary negative selection algorithm based method for early-warning of centrifugal compressor unit without fault data"],"prefix":"10.1177","volume":"43","author":[{"given":"Yang","family":"Lin","sequence":"first","affiliation":[{"name":"State Key Laboratory of Safety and Control for Chemicals, SINOPEC Research Institute of Safety Engineering Co., Ltd., Qingdao, China"}]},{"given":"Yiqun","family":"Ling","sequence":"additional","affiliation":[{"name":"China Petrochemical Corporation, Beijing, China"}]},{"given":"Zhe","family":"Yang","sequence":"additional","affiliation":[{"name":"State Key Laboratory of Safety and Control for Chemicals, SINOPEC Research Institute of Safety Engineering Co., Ltd., Qingdao, China"}]},{"given":"Chunli","family":"Wang","sequence":"additional","affiliation":[{"name":"China Petrochemical Corporation, Beijing, China"}]},{"given":"Chuankun","family":"Li","sequence":"additional","affiliation":[{"name":"State Key Laboratory of Safety and Control for Chemicals, SINOPEC Research Institute of Safety Engineering Co., Ltd., Qingdao, China"}]}],"member":"179","reference":[{"key":"10.3233\/JIFS-213075_ref1","doi-asserted-by":"crossref","first-page":"432","DOI":"10.1016\/j.psep.2020.09.006","article-title":"Time-dependent economic risk analysis of the natural gas transmission pipeline system - ScienceDirect[J]","volume":"146","author":"Shi","year":"2021","journal-title":"Process Safety and Environmental Protection"},{"key":"10.3233\/JIFS-213075_ref2","doi-asserted-by":"crossref","first-page":"1710","DOI":"10.1016\/j.jngse.2015.10.036","article-title":"The early-warning model of equipment chain in gas pipeline based on DNN-HMM[J]","volume":"27","author":"Qiu","year":"2015","journal-title":"Journal of Natural Gas Science & Engineering"},{"key":"10.3233\/JIFS-213075_ref3","doi-asserted-by":"crossref","first-page":"93","DOI":"10.1016\/j.psep.2021.03.052","article-title":"Process Topology Convolutional Network Model for Chemical Process Fault Diagnosis[J]","volume":"150","author":"Wu","year":"2021","journal-title":"Process Safety and Environmental Protection"},{"key":"10.3233\/JIFS-213075_ref4","doi-asserted-by":"crossref","first-page":"146","DOI":"10.1016\/j.conengprac.2018.08.013","article-title":"Combining model-based diagnosis and data-driven anomaly classifiers for fault isolation[J]","volume":"80","author":"Daniel","year":"2018","journal-title":"Control Engineering Practice"},{"key":"10.3233\/JIFS-213075_ref5","doi-asserted-by":"crossref","first-page":"905","DOI":"10.1016\/j.psep.2020.12.016","article-title":"Data-driven techniques for fault detection in anaerobic digestion process[J]","volume":"146","author":"Kazemi","year":"2021","journal-title":"Process Safety and Environmental Protection"},{"key":"10.3233\/JIFS-213075_ref6","doi-asserted-by":"crossref","first-page":"577","DOI":"10.1016\/j.ijepes.2018.01.009","article-title":"A radically data-driven method for fault detection and diagnosis in wind turbines[J]","volume":"99","author":"Yu","year":"2018","journal-title":"International Journal of Electrical Power & Energy Systems"},{"key":"10.3233\/JIFS-213075_ref7","doi-asserted-by":"crossref","first-page":"419","DOI":"10.1016\/j.enbuild.2014.01.003","article-title":"Field implementation and evaluation of a decoupling-based fault detection and diagnostic method for chillers[J]","volume":"72","author":"Zhao","year":"2014","journal-title":"Energy & Buildings"},{"key":"10.3233\/JIFS-213075_ref8","doi-asserted-by":"crossref","first-page":"259","DOI":"10.1016\/j.ymssp.2016.03.018","article-title":"Centrifugal compressor fault diagnosis based on qualitative simulation and thermal parameters[J]","volume":"81","author":"Lu","year":"2016","journal-title":"Mechanical Systems & Signal Processing"},{"key":"10.3233\/JIFS-213075_ref9","doi-asserted-by":"crossref","first-page":"27","DOI":"10.1016\/j.ress.2018.02.007","article-title":"Fault detection and identification method using observer-based residuals[J]","volume":"184","author":"Jeong","year":"2019","journal-title":"Reliability Engineering and System Safety"},{"key":"10.3233\/JIFS-213075_ref10","doi-asserted-by":"crossref","first-page":"119657","DOI":"10.1016\/j.energy.2020.119657","article-title":"A sequential model-based approach for gas turbine performance diagnostics[J]","volume":"220","author":"Chen","year":"2021","journal-title":"Energy"},{"issue":"21","key":"10.3233\/JIFS-213075_ref11","doi-asserted-by":"crossref","first-page":"90","DOI":"10.3182\/20100915-3-IT-2017.00071","article-title":"Principal Component Analysis based on ANOVA Test for Multishaft Centrifugal Compressor Fault Detection and Diagnosis[J]","volume":"43","author":"Zanoli","year":"2010","journal-title":"Ifac Proceedings Volumes"},{"issue":"4","key":"10.3233\/JIFS-213075_ref12","doi-asserted-by":"crossref","first-page":"298","DOI":"10.1016\/j.mechatronics.2013.11.009","article-title":"Data-driven design of robust fault detection system for wind turbines[J]","volume":"24","author":"Yin","year":"2014","journal-title":"Mechatronics"},{"key":"10.3233\/JIFS-213075_ref13","doi-asserted-by":"crossref","first-page":"163","DOI":"10.1016\/j.knosys.2017.02.023","article-title":"Detecting known and unknown faults in automotive systems using ensemble-based anomaly detection[J]","volume":"123","author":"Andreas","year":"2017","journal-title":"Knowledge-Based Systems"},{"key":"10.3233\/JIFS-213075_ref14","doi-asserted-by":"crossref","first-page":"593","DOI":"10.1016\/j.measurement.2018.12.029","article-title":"A novel fault measure and early warning system for air compressor[J]","volume":"135","author":"Cui","year":"2019","journal-title":"Measurement"},{"key":"10.3233\/JIFS-213075_ref15","doi-asserted-by":"crossref","first-page":"104759","DOI":"10.1016\/j.engfailanal.2020.104759","article-title":"Vibration-based fault diagnosis of the natural gas compressor using adaptive stochastic resonance realized by Generative Adversarial Networks[J]","volume":"116","author":"Zhou","year":"2020","journal-title":"Engineering Failure Analysis"},{"issue":"2","key":"10.3233\/JIFS-213075_ref16","doi-asserted-by":"crossref","first-page":"289","DOI":"10.1007\/s10489-014-0599-9","article-title":"An immune optimization based real-valued negative selection algorithm[J]","volume":"42","author":"Xiao","year":"2015","journal-title":"Applied Intelligence"},{"issue":"4","key":"10.3233\/JIFS-213075_ref17","first-page":"2403","article-title":"A Combined Model-Based and Intelligent Method for Small Fault Detection and Isolation of Actuators[J]","volume":"63","author":"Cheng","year":"2016","journal-title":"IEEE Transactions on Industrial Electronics"},{"issue":"99","key":"10.3233\/JIFS-213075_ref18","first-page":"1","article-title":"A Combined Data-Driven and Model-Based Residual Selection Algorithm for Fault Detection and Isolation[J]","volume":"PP","author":"Jung","year":"2017","journal-title":"IEEE Transactions on Control Systems Technology"},{"issue":"2","key":"10.3233\/JIFS-213075_ref19","doi-asserted-by":"crossref","first-page":"108601","DOI":"10.1016\/j.measurement.2020.108601","article-title":"Intelligent fault diagnosis of rotating components in the absence of fault data: A transfer-based approach[J]","volume":"173","author":"Deng","year":"2021","journal-title":"Measurement"},{"issue":"2","key":"10.3233\/JIFS-213075_ref20","doi-asserted-by":"crossref","first-page":"261","DOI":"10.1016\/j.pnsc.2008.06.008","article-title":"A self-adaptive negative selection algorithm used for anomaly detection[J]","volume":"19","author":"Jinquan","year":"2009","journal-title":"Progress in natural Science"},{"issue":"2","key":"10.3233\/JIFS-213075_ref21","doi-asserted-by":"crossref","first-page":"223","DOI":"10.1162\/evco.2007.15.2.223","article-title":"Revisiting Negative Selection Algorithms[J]","volume":"15","author":"Ji","year":"2007","journal-title":"Evolutionary Computation"},{"key":"10.3233\/JIFS-213075_ref22","doi-asserted-by":"crossref","first-page":"261","DOI":"10.1007\/978-3-540-45192-1_25","article-title":"A Randomized Real-Valued Negative Selection Algorithm[J]","volume":"2787","author":"Gonz\u00e1lez","year":"2003","journal-title":"Lecture Notes in Computer Science"},{"issue":"10","key":"10.3233\/JIFS-213075_ref23","doi-asserted-by":"crossref","first-page":"1390","DOI":"10.1016\/j.ins.2008.12.015","article-title":"V-detector: An efficient negative selection algorithm with \u201cprobably adequate\u201d detector coverage[J]","volume":"179","author":"Ji","year":"2009","journal-title":"Information sciences"},{"issue":"3","key":"10.3233\/JIFS-213075_ref24","doi-asserted-by":"crossref","first-page":"281","DOI":"10.1109\/TEVC.2002.1011541","article-title":"An immunity-based technique to characterize intrusions in computer networks[J]","volume":"6","author":"Dasgupta","year":"2002","journal-title":"IEEE Transactions on Evolutionary Computation"},{"key":"10.3233\/JIFS-213075_ref25","doi-asserted-by":"crossref","first-page":"93","DOI":"10.1016\/j.engappai.2015.12.014","article-title":"A negative selection algorithm with online adaptive learning under small samples for anomaly detection[J]","volume":"50","author":"Li","year":"2016","journal-title":"Engineering Applications of Artificial Intelligence"},{"key":"10.3233\/JIFS-213075_ref26","doi-asserted-by":"crossref","first-page":"515","DOI":"10.1016\/j.neucom.2014.08.022","article-title":"A negative selection algorithm with online adaptive learning under small samples for anomaly detection[J]","volume":"149","author":"Li","year":"2015","journal-title":"Neurocomputing"},{"issue":"5","key":"10.3233\/JIFS-213075_ref27","doi-asserted-by":"crossref","first-page":"4685","DOI":"10.3233\/JIFS-18113","article-title":"A time lag based correlation analysis model for index selection in state evaluation of centrifugal compressor unit[J]","volume":"34","author":"Lin","year":"2018","journal-title":"Journal of Intelligent & Fuzzy Systems"}],"container-title":["Journal of Intelligent &amp; Fuzzy Systems"],"original-title":[],"link":[{"URL":"https:\/\/content.iospress.com\/download?id=10.3233\/JIFS-213075","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,1,30]],"date-time":"2026-01-30T15:19:53Z","timestamp":1769786393000},"score":1,"resource":{"primary":{"URL":"https:\/\/journals.sagepub.com\/doi\/full\/10.3233\/JIFS-213075"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2022,6,1]]},"references-count":27,"journal-issue":{"issue":"1"},"URL":"https:\/\/doi.org\/10.3233\/jifs-213075","relation":{},"ISSN":["1064-1246","1875-8967"],"issn-type":[{"value":"1064-1246","type":"print"},{"value":"1875-8967","type":"electronic"}],"subject":[],"published":{"date-parts":[[2022,6,1]]}}}