{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,4,29]],"date-time":"2026-04-29T12:11:50Z","timestamp":1777464710555,"version":"3.51.4"},"reference-count":40,"publisher":"SAGE Publications","issue":"4","content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["BME"],"published-print":{"date-parts":[[2020,9,14]]},"abstract":"<jats:p>BACKGROUND: Laminectomy may cause kyphotic postoperative deformity in the cervical region leading to segmental instability over time. Laminoplasty may be an alternative procedure to laminectomy, as it protects the spine against post-laminectomy kyphosis; however, similar to laminectomy, laminoplasty may cause sagittal plane deformities by destructing or weakening the dorsal tension band. OBJECTIVE: Using finite element analysis (FE), we attempted to determine whether a posterior motion preservation system (PEEK posterior rod system concept) could overcome the postoperative complications of laminectomy and laminoplasty and eliminate the side effects of rigid posterior stabilization in the cervical region. METHODS: We compared PEEK rods in four different diameters with a titanium rod for posterior cervical fixation. The present study may lead to motion preservation systems of the cervical vertebra. RESULTS: When PEEK rod is compared with titanium rod, considerable increase in range of motion is observed. CONCLUSIONS: PEEK rod-lateral mass screw instrumentation systems may be useful in motion preservation surgery of the posterior cervical region.<\/jats:p>","DOI":"10.3233\/bme-206004","type":"journal-article","created":{"date-parts":[[2020,9,4]],"date-time":"2020-09-04T12:09:13Z","timestamp":1599221353000},"page":"235-251","source":"Crossref","is-referenced-by-count":2,"title":["A new concept of motion preservation surgery of the cervical spine: PEEK rods for the posterior cervical region"],"prefix":"10.1177","volume":"31","author":[{"given":"Ahmet Levent","family":"Aydin","sequence":"first","affiliation":[{"name":", Ko\u00e7 University, , Turkey"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Mehdi","family":"Sasani","sequence":"additional","affiliation":[{"name":", Ko\u00e7 University, , Turkey"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Deniz Ufuk","family":"Erbulut","sequence":"additional","affiliation":[{"name":", University of Toledo, , , USA"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Tunc","family":"Oktenoglu","sequence":"additional","affiliation":[{"name":", Ko\u00e7 University, , Turkey"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Ali Fahir","family":"Ozer","sequence":"additional","affiliation":[{"name":", Ko\u00e7 University, , Turkey"}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"179","reference":[{"issue":"5","key":"10.3233\/BME-206004_ref1","doi-asserted-by":"crossref","first-page":"669","DOI":"10.1007\/s00586-006-0254-1","article-title":"The association between cervical spine curvature and neck pain","volume":"16","author":"Grob","year":"2007","journal-title":"Eur Spine J"},{"issue":"1","key":"10.3233\/BME-206004_ref3","doi-asserted-by":"crossref","first-page":"57","DOI":"10.3171\/PED-08\/01\/057","article-title":"Incidence of spinal deformity after resection of intramedullary spinal cord tumors in children who underwent laminectomy compared with laminoplasty","volume":"1","author":"McGirt","year":"2008","journal-title":"J Neurosurg Pediatr"},{"key":"10.3233\/BME-206004_ref5","doi-asserted-by":"crossref","first-page":"66","DOI":"10.1016\/j.jocn.2017.10.089","article-title":"Outcomes of cervical laminoplasty-Population-level analysis of a national longitudinal database","volume":"48","author":"Veeravagu","year":"2018","journal-title":"J Clin Neurosci"},{"key":"10.3233\/BME-206004_ref6","first-page":"356","article-title":"Comparison of anterior and posterior approaches in cervical myelopathy treatment","volume":"16","author":"Aydogan","year":"2017","journal-title":"TOTB\u0130D Dergisi"},{"issue":"6","key":"10.3233\/BME-206004_ref7","doi-asserted-by":"crossref","first-page":"956","DOI":"10.1302\/0301-620X.77B6.7593114","article-title":"Long-term follow-up of cervical spondylotic myelopathy treated by canal-expansive laminoplasty","volume":"77","author":"Kimura","year":"1995","journal-title":"J Bone Joint Surg Br"},{"issue":"1","key":"10.3233\/BME-206004_ref8","doi-asserted-by":"crossref","first-page":"26","DOI":"10.1016\/S1529-9430(01)00008-0","article-title":"Short-term complications and long term results of expansive open-door laminoplasty for cervical stenotic myelopathy","volume":"1","author":"Satomi","year":"2001","journal-title":"Spine J"},{"issue":"5","key":"10.3233\/BME-206004_ref9","doi-asserted-by":"crossref","first-page":"482","DOI":"10.1016\/j.medengphy.2010.03.001","article-title":"Validation of a C2\u2013C7 cervical spine finite element model using specimen-specific flexibility data","volume":"32","author":"Kallemeyn","year":"2010","journal-title":"Med Eng Phys"},{"issue":"1","key":"10.3233\/BME-206004_ref10","doi-asserted-by":"crossref","first-page":"76","DOI":"10.1227\/00006123-198007000-00014","article-title":"Basic biomechanics of the spine","volume":"7","author":"Panjabi","year":"1980","journal-title":"Neurosurgery"},{"key":"10.3233\/BME-206004_ref11","volume-title":"Clinical Biomechanics of the Spine","author":"White","year":"1990"},{"key":"10.3233\/BME-206004_ref12","first-page":"185","volume-title":"The Textbook of Spinal Surgery","author":"Bernhardt","year":"1997"},{"issue":"5","key":"10.3233\/BME-206004_ref13","doi-asserted-by":"crossref","first-page":"642","DOI":"10.2106\/00004623-197658050-00011","article-title":"Mechanical properties of the human thoracic spine as shown by three-dimensional load-displacement curves","volume":"58","author":"Panjabi","year":"1976","journal-title":"J Bone Joint Surg Am"},{"issue":"3","key":"10.3233\/BME-206004_ref14","first-page":"126","article-title":"Cervical laminoplasty","volume":"19","author":"Palaoglu","year":"2009","journal-title":"Turk Norosirurji Dergisi"},{"key":"10.3233\/BME-206004_ref15","first-page":"375","volume-title":"Biomechanics of Spine Stabilization","author":"Benzel","year":"2001"},{"issue":"29","key":"10.3233\/BME-206004_ref16","doi-asserted-by":"crossref","first-page":"e11542","DOI":"10.1097\/MD.0000000000011542","article-title":"Comparison of laminoplasty versus laminectomy and fusion in the treatment of multilevel cervical ossification of the posterior longitudinal ligament: A systematic review and meta-analysis","volume":"97","author":"Ma","year":"2018","journal-title":"Medicine (Baltimore)"},{"issue":"2","key":"10.3233\/BME-206004_ref17","doi-asserted-by":"crossref","first-page":"150","DOI":"10.3171\/2009.2.SPINE08727","article-title":"Laminectomy and fusion for the treatment of cervical degenerative myelopathy","volume":"11","author":"Anderson","year":"2009","journal-title":"J Neurosurg Spine"},{"issue":"5","key":"10.3233\/BME-206004_ref18","doi-asserted-by":"crossref","first-page":"508","DOI":"10.3171\/2017.4.SPINE16831","article-title":"Laminoplasty versus laminectomy with posterior spinal fusion for multilevel cervical spondylotic myelopathy: Influence of cervical alignment on outcomes","volume":"27","author":"Lau","year":"2017","journal-title":"J Neurosurg Spine"},{"issue":"1","key":"10.3233\/BME-206004_ref19","doi-asserted-by":"crossref","first-page":"91","DOI":"10.1016\/j.nec.2017.09.017","article-title":"Laminectomy with or without fusion to manage degenerative cervical myelopathy","volume":"29","author":"Abduljabbar","year":"2018","journal-title":"Neurosurg Clin N Am"},{"key":"10.3233\/BME-206004_ref21","doi-asserted-by":"crossref","first-page":"451956","DOI":"10.1155\/2013\/451956","article-title":"Biomechanics of posterior dynamic stabilization systems","volume":"2013","author":"Erbulut","year":"2013","journal-title":"Adv Orthop"},{"issue":"2","key":"10.3233\/BME-206004_ref22","doi-asserted-by":"crossref","first-page":"200","DOI":"10.3171\/2014.12.SPINE14419","article-title":"Determination of the biomechanical effect of an interspinous process device on implanted and adjacent lumbar spinal segments using a hybrid testing protocol: A finite-element study","volume":"23","author":"Erbulut","year":"2015","journal-title":"J Neurosurg Spine"},{"issue":"2","key":"10.3233\/BME-206004_ref23","first-page":"188","article-title":"Posterior dynamic stabilization for the treatment of patients with lumbar degenerative disc disease: Long-term clinical and radiological results","volume":"23","author":"Canbay","year":"2013","journal-title":"Turk Neurosurg"},{"key":"10.3233\/BME-206004_ref24","doi-asserted-by":"crossref","first-page":"753470","DOI":"10.1155\/2013\/753470","article-title":"Dynamic stabilization for challenging lumbar degenerative diseases of the spine: A review of the literature","volume":"2013","author":"Kaner","year":"2013","journal-title":"Adv Orthop"},{"key":"10.3233\/BME-206004_ref25","doi-asserted-by":"crossref","unstructured":"T. Kaner, S. Dalbayrak, T. Oktenoglu, M. Sasani, A.L. Aydin and A.F. Ozer, Comparison of posterior dynamic and posterior rigid transpedicular stabilization with fusion to treat degenerative spondylolisthesis, Orthopedics 33(5) (2010).","DOI":"10.3928\/01477447-20100329-09"},{"issue":"3","key":"10.3233\/BME-206004_ref26","doi-asserted-by":"crossref","first-page":"130","DOI":"10.1016\/S1935-9810(08)70029-X","article-title":"The combined use of a posterior dynamic transpedicular stabilization system and a prosthetic disc nucleus device in treating lumbar degenerative disc disease with disc herniations","volume":"2","author":"Sasani","year":"2008","journal-title":"SAS J"},{"issue":"4","key":"10.3233\/BME-206004_ref27","doi-asserted-by":"crossref","first-page":"044101","DOI":"10.1088\/1748-6041\/3\/4\/044101","article-title":"Comparison of the load-sharing characteristics between pedicle-based dynamic and rigid rod devices","volume":"3","author":"Ahn","year":"2008","journal-title":"Biomed Mater"},{"issue":"3","key":"10.3233\/BME-206004_ref28","doi-asserted-by":"crossref","first-page":"310","DOI":"10.4055\/cios.2017.9.3.310","article-title":"Lumbar single-level dynamic stabilization with semi-rigid and full dynamic systems: A retrospective clinical and radiological analysis of 71 patients","volume":"9","author":"Ozer","year":"2017","journal-title":"Clin Orthop Surg"},{"key":"10.3233\/BME-206004_ref29","doi-asserted-by":"crossref","first-page":"53","DOI":"10.1186\/s12891-016-0913-2","article-title":"Non-fusion procedure using PEEK rod systems for lumbar degenerative diseases: Clinical experience with a 2-year follow-up","volume":"17","author":"Huang","year":"2016","journal-title":"BMC Musculoskelet Disord"},{"issue":"Suppl 1","key":"10.3233\/BME-206004_ref30","doi-asserted-by":"crossref","first-page":"S111","DOI":"10.1007\/s00590-014-1421-4","article-title":"PEEK rod systems for the spine","volume":"24","author":"Mavrogenis","year":"2014","journal-title":"Eur J Orthop Surg Traumatol"},{"issue":"8","key":"10.3233\/BME-206004_ref31","doi-asserted-by":"crossref","first-page":"081009","DOI":"10.1115\/1.4004862","article-title":"Biomechanical assessment of a PEEK rod system for semi-rigid fixation of lumbar fusion constructs","volume":"133","author":"Gornet","year":"2011","journal-title":"J Biomech Eng"},{"key":"10.3233\/BME-206004_ref32","doi-asserted-by":"crossref","first-page":"106","DOI":"10.1016\/j.jocn.2019.01.029","article-title":"Implant failure of pedicle screws in long-segment posterior cervical fusion is likely to occur at C7 and is avoidable by concomitant C6 or T1 buttress pedicle screws","volume":"63","author":"Nagashima","year":"2019","journal-title":"J Clin Neurosci"},{"issue":"5","key":"10.3233\/BME-206004_ref33","doi-asserted-by":"crossref","first-page":"699","DOI":"10.3109\/02688697.2015.1026798","article-title":"Cervical lateral mass screw-rod fixation: Surgical experience with 2500 consecutive screws, an analytical review, and long-term outcomes","volume":"29","author":"Al Barbarawi","year":"2015","journal-title":"Br J Neurosurg"},{"issue":"4","key":"10.3233\/BME-206004_ref34","doi-asserted-by":"crossref","first-page":"548","DOI":"10.1016\/j.wneu.2014.12.008","article-title":"Biomechanical comparison of cervical fixation via transarticular facet screws without rods versus lateral mass screws with rods","volume":"83","author":"Yi","year":"2015","journal-title":"World Neurosurg"},{"issue":"6","key":"10.3233\/BME-206004_ref35","doi-asserted-by":"crossref","first-page":"983","DOI":"10.1227\/NEU.0b013e31828e20ff","article-title":"Analysis of cervical sagittal alignment after screw-rod fixation","volume":"72","author":"Heary","year":"2013","journal-title":"Neurosurgery"},{"key":"10.3233\/BME-206004_ref36","doi-asserted-by":"crossref","first-page":"18","DOI":"10.1016\/j.clinbiomech.2018.04.001","article-title":"Posterior cervical spine crisscross fixation: Biomechanical evaluation","volume":"55","author":"Cusick","year":"2018","journal-title":"Clin Biomech (Bristol, Avon)"},{"key":"10.3233\/BME-206004_ref37","doi-asserted-by":"crossref","first-page":"103519","DOI":"10.1016\/j.compbiomed.2019.103519","article-title":"Using finite element analysis to determine effects of the motion loading method on facet joint forces after cervical disc degeneration","volume":"116","author":"Cai","year":"2020","journal-title":"Comput Biol Med"},{"key":"10.3233\/BME-206004_ref38","doi-asserted-by":"crossref","first-page":"e905","DOI":"10.1016\/j.wneu.2019.05.025","article-title":"Comparison of the biomechanical changes after percutaneous full-endoscopic anterior cervical discectomy versus posterior cervical foraminotomy at C5-C6: A finite element-based study","volume":"128","author":"Yuchi","year":"2019","journal-title":"World Neurosurg"},{"issue":"1","key":"10.3233\/BME-206004_ref39","doi-asserted-by":"crossref","first-page":"71","DOI":"10.1186\/s13018-019-1113-1","article-title":"Biomechanical comparison of percutaneous posterior endoscopic cervical discectomy and anterior cervical decompression and fusion on the treatment of cervical spondylotic radiculopathy","volume":"14","author":"Ren","year":"2019","journal-title":"J Orthop Surg Res"},{"issue":"3","key":"10.3233\/BME-206004_ref40","doi-asserted-by":"crossref","first-page":"e3162","DOI":"10.1002\/cnm.3162","article-title":"A comparison of the influence of three different lumbar interbody fusion approaches on stress in the pedicle screw fixation system: Finite element static and vibration analyses","volume":"35","author":"Fan","year":"2019","journal-title":"Int J Numer Method Biomed Eng"},{"issue":"Suppl 2","key":"10.3233\/BME-206004_ref41","doi-asserted-by":"crossref","first-page":"168","DOI":"10.1186\/s12938-016-0246-2","article-title":"Compression-distraction reduction surgical verification and optimization to treat the basilar invagination and atlantoaxial dislocation: A finite element analysis","volume":"15","author":"Bo","year":"2016","journal-title":"Biomed Eng Online"},{"issue":"15","key":"10.3233\/BME-206004_ref42","doi-asserted-by":"crossref","first-page":"2875","DOI":"10.1016\/j.jbiomech.2010.07.027","article-title":"Computational analysis of bone remodeling during an anterior cervical fusion","volume":"43","author":"Espinha","year":"2010","journal-title":"J Biomech"},{"issue":"3","key":"10.3233\/BME-206004_ref43","doi-asserted-by":"crossref","first-page":"477","DOI":"10.1243\/09544119JEIM611","article-title":"Stress analysis in a pedicle screw fixation system with flexible rods in the lumbar spine","volume":"224","author":"Kim","year":"2010","journal-title":"Proc Inst Mech Eng H"}],"container-title":["Bio-Medical Materials and Engineering"],"original-title":[],"link":[{"URL":"https:\/\/content.iospress.com\/download?id=10.3233\/BME-206004","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,4,28]],"date-time":"2026-04-28T13:23:58Z","timestamp":1777382638000},"score":1,"resource":{"primary":{"URL":"https:\/\/journals.sagepub.com\/doi\/full\/10.3233\/BME-206004"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2020,9,14]]},"references-count":40,"journal-issue":{"issue":"4"},"URL":"https:\/\/doi.org\/10.3233\/bme-206004","relation":{},"ISSN":["0959-2989","1878-3619"],"issn-type":[{"value":"0959-2989","type":"print"},{"value":"1878-3619","type":"electronic"}],"subject":[],"published":{"date-parts":[[2020,9,14]]}}}