{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,5,27]],"date-time":"2026-05-27T20:11:06Z","timestamp":1779912666296,"version":"3.53.1"},"reference-count":20,"publisher":"SAGE Publications","issue":"6","content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["BME"],"published-print":{"date-parts":[[2022,11,2]]},"abstract":"<jats:p>BACKGROUND: With the increasing aging of population, the incidence rate of diseases such as fracture and osteoporosis has been increasing. The demand for implant in Department of orthopedics has increased. The elastic modulus of the existing solid metal implant is much higher than that of human bone tissue, and it is easy to produce stress shielding effect after operation, which causes complications such as loosening of prosthesis and low fusion efficiency. OBJECTIVE: In order to solve the mismatch of elastic modulus between solid metal orthopedic implants and human bone tissue, metal structures with excellent mechanical properties were prepared. METHODS: The porous structure was designed by spatial dot matrix method, and the metal porous structure was prepared based on selective laser melting 3D printing technology. The residual stress in the preparation process was eliminated by vacuum annealing heat treatment, and the static compression experiment was carried out to study the effects of different pore shape and porosity parameters on the compressive yield strength and elastic modulus of porous structure. The performance changes of porous structure before and after heat treatment were compared, and the porous structure meeting the performance requirements of human bone tissue was selected. RESULTS: The porous structure prepared by selective laser melting technology met the requirements of human bone tissue. The elastic modulus was as low as 0.74\u00a0GPa and the compressive yield strength is 201.91\u00a0MPa; After annealing heat treatment, the compressive yield strength of porous structure decreased, the maximum change was 3.69%, the elastic modulus increased, and the maximum change was 8.69%. CONCLUSIONS: For the porous structure with the same pore shape, the lower the porosity, the better the mechanical properties of the porous structure. For the same porosity, the comprehensive mechanical properties of dodecahedral porous structure were the best and octahedral porous structure was the worst; the porous structure after annealing heat treatment was more conducive to meet the performance requirements of human bone tissue.<\/jats:p>","DOI":"10.3233\/bme-211377","type":"journal-article","created":{"date-parts":[[2022,5,31]],"date-time":"2022-05-31T11:59:58Z","timestamp":1653998398000},"page":"465-476","source":"Crossref","is-referenced-by-count":6,"title":["Preparation and mechanical properties analysis of porous structure for bone tissue engineering"],"prefix":"10.1177","volume":"33","author":[{"given":"Jingbin","family":"Cui","sequence":"first","affiliation":[{"name":"School of Mechanical Engineering, Yanshan University, , , China"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Yali","family":"Yi","sequence":"additional","affiliation":[{"name":"School of Mechanical Engineering, Yanshan University, , , China"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Jinming","family":"Zhang","sequence":"additional","affiliation":[{"name":"School of Mechanical Engineering, Yanshan University, , , China"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Liping","family":"Chai","sequence":"additional","affiliation":[{"name":"Hebei Ruihe Medical Equipment Co. Ltd, , , China"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Herong","family":"Jin","sequence":"additional","affiliation":[{"name":"Parallel Robot and Mechatronic System Laboratory of Hebei Province, Yanshan University, , , China"},{"name":"Key Laboratory of Advanced Forging and Stamping Technology and Science of Ministry of National Education, Yanshan University, , , China"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"179","reference":[{"issue":"11","key":"10.3233\/BME-211377_ref1","first-page":"249","article-title":"Evaluation of mechanical, antimicrobial efficacy and biocompatibility of si doped carbon coatings onto stainless steel and titanium orthopaedic implants","volume":"96-B","author":"Bociaga","year":"2018","journal-title":"Orthopaedic Proc"},{"key":"10.3233\/BME-211377_ref2","doi-asserted-by":"publisher","first-page":"100270","DOI":"10.1016\/j.jbiomech.2021.110270","article-title":"Decreased stress shielding with a PEEK femoral total knee prosthesis measured in validated computational models","volume":"118","author":"Ruiter","year":"2021","journal-title":"J Biomech"},{"key":"10.3233\/BME-211377_ref3","doi-asserted-by":"publisher","first-page":"104608","DOI":"10.1016\/j.jmbbm.2021.104608","article-title":"Mechanical interaction between additive-manufactured metal lattice structures and bone in compression: Implications for stress shielding of orthopaedic implants","volume":"121","author":"Liverani","year":"2021","journal-title":"J Mech Behav Biomed"},{"issue":"12","key":"10.3233\/BME-211377_ref4","doi-asserted-by":"publisher","first-page":"2632","DOI":"10.1016\/j.jse.2020.03.037","article-title":"Proximal-medial part in the coracoid graft demonstrates the most evident stress shielding following the Latarjet procedure: A simulation study using the 3-dimensional finite element method","volume":"29","author":"Sano","year":"2020","journal-title":"J Shoulder Elb Surg"},{"key":"10.3233\/BME-211377_ref5","doi-asserted-by":"publisher","first-page":"132","DOI":"10.1016\/j.jor.2019.09.008","article-title":"Stress shielding analysis on easy step staple prosthesis for calcaneus fractures","volume":"18","author":"Filardi","year":"2020","journal-title":"J Orthoped"},{"key":"10.3233\/BME-211377_ref6","doi-asserted-by":"publisher","first-page":"112247","DOI":"10.1016\/j.msec.2021.112247","article-title":"Femtosecond laser-induced nanoporous layer for enhanced osteogenesis of titanium implants","volume":"127","author":"Yao","year":"2021","journal-title":"Mater Sci Eng C"},{"issue":"44","key":"10.3233\/BME-211377_ref7","doi-asserted-by":"publisher","first-page":"28684","DOI":"10.1021\/acsomega.0c03824","article-title":"Effect of pore size on the physicochemical properties and osteogenesis of Ti6Al4V porous scaffolds with bionic structure","volume":"5","author":"Wang","year":"2020","journal-title":"ACS Omega"},{"issue":"11","key":"10.3233\/BME-211377_ref8","doi-asserted-by":"publisher","first-page":"154","DOI":"10.14016\/j.cnki.jgzz.2019.11.154","article-title":"The study on mechanical properties of porous tantalum components formed by laser selective melting","volume":"40","author":"Wu","year":"2019","journal-title":"Laser J"},{"issue":"2","key":"10.3233\/BME-211377_ref9","doi-asserted-by":"publisher","first-page":"185","DOI":"10.1177\/0954411917751558","article-title":"Microstructure and mechanical properties of porous titanium structures fabricated by electron beam melting for cranial implants","volume":"232","author":"Moiduddin","year":"2018","journal-title":"Proc Inst Mech Eng, Part H, J Eng Med"},{"key":"10.3233\/BME-211377_ref10","doi-asserted-by":"publisher","first-page":"117186","DOI":"10.1016\/j.jmatprotec.2021.117186","article-title":"Radially graded porous structure design for laser powder bed fusion additive manufacturing of Ti-6Al-4V alloy","volume":"296","author":"Kas","year":"2021","journal-title":"J Mater Process Technol"},{"key":"10.3233\/BME-211377_ref11","doi-asserted-by":"publisher","first-page":"104222","DOI":"10.1016\/j.jmbbm.2020.104222","article-title":"Porous structure design and mechanical behavior analysis based on TPMS for customized root analogue implant","volume":"115","author":"Song","year":"2021","journal-title":"J Mech Behav Biomed"},{"key":"10.3233\/BME-211377_ref12","doi-asserted-by":"publisher","first-page":"106331","DOI":"10.1016\/j.ijmecsci.2021.106331","article-title":"A topology strategy to reduce stress shielding of additively manufactured porous metallic biomaterials","volume":"197","author":"Zhang","year":"2021","journal-title":"Int J Mech Sci"},{"key":"10.3233\/BME-211377_ref13","doi-asserted-by":"publisher","first-page":"1562","DOI":"10.1016\/j.jallcom.2017.11.263","article-title":"Effect of subtransus heat treatment on the microstructure and mechanical properties of additively manufactured Ti-6Al-4V alloy","volume":"735","author":"Zhang","year":"2018","journal-title":"J Alloys Compd"},{"key":"10.3233\/BME-211377_ref14","doi-asserted-by":"publisher","first-page":"300","DOI":"10.1016\/j.ijfatigue.2012.11.011","article-title":"On the mechanical behaviour of titanium alloy TiAl6V4 manufactured by selective laser melting: Fatigue resistance and crack growth performance","volume":"48","author":"Leuders","year":"2013","journal-title":"Int J Fatigue"},{"key":"10.3233\/BME-211377_ref15","doi-asserted-by":"publisher","first-page":"1056","DOI":"10.1016\/j.jallcom.2018.06.076","article-title":"Effect of heat treatment on the phase transformation and mechanical properties of Ti6Al4V fabricated by selective laser melting","volume":"764","author":"Yan","year":"2018","journal-title":"J Alloys Compd"},{"issue":"52","key":"10.3233\/BME-211377_ref16","doi-asserted-by":"publisher","first-page":"7821","DOI":"10.3969\/j.issn.2095-4344.2016.52.010","article-title":"3D printing titanium alloy pore support bone ingrowth analysis","volume":"20","author":"Wang","year":"2016","journal-title":"Chin J Tissue Eng Res"},{"key":"10.3233\/BME-211377_ref17","doi-asserted-by":"publisher","first-page":"690","DOI":"10.1016\/j.msec.2015.10.069","article-title":"Effect of pore size on bone ingrowth into porous titanium implants fabricated by additive manufacturing: An in vivo experiment \u2013 ScienceDirect","volume":"59","author":"Naoya","year":"2016","journal-title":"Mater Sci Eng: C"},{"issue":"5","key":"10.3233\/BME-211377_ref18","doi-asserted-by":"publisher","first-page":"711","DOI":"10.1007\/s00402-010-1218-9","article-title":"Frictional and bone ingrowth properties of engineered surface topographies produced by electron beam technology","volume":"131","author":"Biemond","year":"2011","journal-title":"Arch Orthop Traum Surg"},{"issue":"18","key":"10.3233\/BME-211377_ref19","doi-asserted-by":"publisher","first-page":"2810","DOI":"10.1016\/j.biomaterials.2007.02.020","article-title":"Bone ingrowth in porous titanium implants produced by 3D fiber deposition","volume":"28","author":"Li","year":"2007","journal-title":"Biomaterials"},{"issue":"10","key":"10.3233\/BME-211377_ref20","doi-asserted-by":"publisher","first-page":"138","DOI":"10.13251\/j.issn.0254-6051.2018.10.028","article-title":"Influence of heat treatment on performance of TC4 alloy manufactured by selective laser melting","volume":"43","author":"Zhou","year":"2018","journal-title":"Heat Treat Met"}],"container-title":["Bio-Medical Materials and Engineering"],"original-title":[],"link":[{"URL":"https:\/\/content.iospress.com\/download?id=10.3233\/BME-211377","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,4,28]],"date-time":"2026-04-28T13:24:17Z","timestamp":1777382657000},"score":1,"resource":{"primary":{"URL":"https:\/\/journals.sagepub.com\/doi\/full\/10.3233\/BME-211377"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2022,11,2]]},"references-count":20,"journal-issue":{"issue":"6"},"URL":"https:\/\/doi.org\/10.3233\/bme-211377","relation":{},"ISSN":["0959-2989","1878-3619"],"issn-type":[{"value":"0959-2989","type":"print"},{"value":"1878-3619","type":"electronic"}],"subject":[],"published":{"date-parts":[[2022,11,2]]}}}