{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,9,15]],"date-time":"2026-09-15T12:22:57Z","timestamp":1789474977980,"version":"build-2803163510"},"reference-count":19,"publisher":"SAGE Publications","issue":"2","content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["BMR"],"published-print":{"date-parts":[[2019,3,11]]},"DOI":"10.3233\/bmr-170870","type":"journal-article","created":{"date-parts":[[2018,10,16]],"date-time":"2018-10-16T12:01:32Z","timestamp":1539691292000},"page":"261-267","source":"Crossref","is-referenced-by-count":14,"title":["Can an unipedicular approach replace bipedicular percutaneous vertebroplasty for osteoporotic vertebral compression fracture?"],"prefix":"10.1177","volume":"32","author":[{"given":"Wentao","family":"Wang","sequence":"first","affiliation":[{"name":"Department of Spine Surgery, Honghui Hospital, Xi\u2019an Jiaotong University College of Medicine, Xi\u2019an 710054, Shaanxi, China"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Kun","family":"Duan","sequence":"additional","affiliation":[{"name":"Department of General Surgery, The 417th Hospital, China National Nuclear Corporation, Xi\u2019an 710054, Shaanxi, China"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Minjie","family":"Ma","sequence":"additional","affiliation":[{"name":"Department of Spine Surgery, Honghui Hospital, Xi\u2019an Jiaotong University College of Medicine, Xi\u2019an 710054, Shaanxi, China"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Yong","family":"Jiang","sequence":"additional","affiliation":[{"name":"Department of Spine Surgery, Honghui Hospital, Xi\u2019an Jiaotong University College of Medicine, Xi\u2019an 710054, Shaanxi, China"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Tuanjiang","family":"Liu","sequence":"additional","affiliation":[{"name":"Department of Spine Surgery, Honghui Hospital, Xi\u2019an Jiaotong University College of Medicine, Xi\u2019an 710054, Shaanxi, China"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Jijun","family":"Liu","sequence":"additional","affiliation":[{"name":"Department of Spine Surgery, Honghui Hospital, Xi\u2019an Jiaotong University College of Medicine, Xi\u2019an 710054, Shaanxi, China"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Dingjun","family":"Hao","sequence":"additional","affiliation":[{"name":"Department of Spine Surgery, Honghui Hospital, Xi\u2019an Jiaotong University College of Medicine, Xi\u2019an 710054, Shaanxi, China"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"179","reference":[{"issue":"33","key":"10.3233\/BMR-170870_ref1","first-page":"166","article-title":"[Preliminary note on the treatment of vertebral angioma by percutaneous acrylic vertebroplasty]","volume":"2","author":"Galibert","year":"1987","journal-title":"Neurochirurgie."},{"issue":"36","key":"10.3233\/BMR-170870_ref2","doi-asserted-by":"crossref","first-page":"533","DOI":"10.1016\/S0033-8389(05)70042-7","article-title":"Percutaneous vertebroplasty with polymethylmethacrylate","volume":"3","author":"Deramond","year":"1998","journal-title":"Technique, indications, and results. Radiol Clin North Am."},{"issue":"24","key":"10.3233\/BMR-170870_ref3","doi-asserted-by":"crossref","first-page":"187","DOI":"10.1007\/s11604-005-1542-0","article-title":"Unilateral transpedicular percutaneous vertebroplasty using puncture simulation","volume":"3","author":"Kobayashi","year":"2006","journal-title":"Radiat Med."},{"key":"10.3233\/BMR-170870_ref4","doi-asserted-by":"crossref","first-page":"145","DOI":"10.1186\/s12891-015-0590-6","article-title":"Unipedicular versus bipedicular percutaneous vertebroplasty for osteoporotic vertebral compression fractures: a prospective randomized study","volume":"16","author":"Zhang","year":"2015","journal-title":"BMC Musculoskelet Disord."},{"issue":"28","key":"10.3233\/BMR-170870_ref5","doi-asserted-by":"crossref","first-page":"E85","DOI":"10.1097\/BSD.0000000000000147","article-title":"Unilateral or bilateral percutaneous vertebroplasty for acute osteoporotic vertebral fracture: a prospective study","volume":"2","author":"Zhang","year":"2015","journal-title":"J Spinal Disord Tech."},{"issue":"31","key":"10.3233\/BMR-170870_ref6","doi-asserted-by":"crossref","first-page":"504","DOI":"10.3174\/ajnr.A1861","article-title":"Clinical experience with high-viscosity cements for percutaneous vertebral body augmentation: occurrence, degree, and location of cement leakage compared with kyphoplasty","volume":"3","author":"Georgy","year":"2010","journal-title":"AJNR Am J Neuroradiol."},{"issue":"35","key":"10.3233\/BMR-170870_ref7","doi-asserted-by":"crossref","first-page":"E1037","DOI":"10.1097\/BRS.0b013e3181ddd262","article-title":"A clinical comparative study on low versus medium viscosity polymethylmetacrylate bone cement in percutaneous vertebroplasty: viscosity associated with cement leakage","volume":"20","author":"Nieuwenhuijse","year":"2010","journal-title":"Spine (Phila Pa 1976)"},{"issue":"222","key":"10.3233\/BMR-170870_ref8","doi-asserted-by":"crossref","first-page":"737","DOI":"10.1148\/radiol.2223010718","article-title":"Unilateral transpedicular percutaneous vertebroplasty: initial experience","volume":"3","author":"Kim","year":"2002","journal-title":"Radiology."},{"key":"10.3233\/BMR-170870_ref9","doi-asserted-by":"crossref","first-page":"S2","DOI":"10.1007\/s00586-009-1114-6","article-title":"Classification of thoracolumbar fractures and dislocations","volume":"19","author":"Aebi","year":"2010","journal-title":"Eur Spine J."},{"issue":"24","key":"10.3233\/BMR-170870_ref10","doi-asserted-by":"crossref","first-page":"1772","DOI":"10.1097\/00007632-199909010-00004","article-title":"Biomechanical efficacy of unipedicular versus bipedicular vertebroplasty for the management of osteoporotic compression fractures","volume":"17","author":"Tohmeh","year":"1999","journal-title":"Spine (Phila Pa 1976)"},{"key":"10.3233\/BMR-170870_ref11","doi-asserted-by":"crossref","first-page":"B19","DOI":"10.1097\/BRS.0000000000000493","article-title":"A comparison between unilateral transverse process-pedicle and bilateral puncture techniques in percutaneous kyphoplasty","volume":"26","author":"Yan","year":"2014","journal-title":"Spine (Phila Pa 1976)"},{"issue":"32","key":"10.3233\/BMR-170870_ref12","doi-asserted-by":"crossref","first-page":"817","DOI":"10.1007\/s00264-007-0439-1","article-title":"Comparative study of balloon kyphoplasty with unilateral versus bilateral approach in osteoporotic vertebral compression fractures","volume":"6","author":"Chung","year":"2008","journal-title":"Int Orthop."},{"issue":"24","key":"10.3233\/BMR-170870_ref13","doi-asserted-by":"crossref","first-page":"E62","DOI":"10.1097\/BSD.0b013e318228f470","article-title":"Comparative study of kyphoplasty for chronic painful osteoporotic vertebral compression fractures via unipedicular versus bipedicular approach","volume":"7","author":"Chen","year":"2011","journal-title":"J Spinal Disord Tech."},{"issue":"13","key":"10.3233\/BMR-170870_ref14","first-page":"4277","article-title":"Biomechanical changes following vertebroplasty by unilateral or bilateral approach: Finite element analysis","volume":"22","author":"Long","year":"2009","journal-title":"Zhongguo Zuzhi Gongcheng Yanjiu yu Linchuang Kangfu."},{"key":"10.3233\/BMR-170870_ref15","doi-asserted-by":"crossref","first-page":"260","DOI":"10.1186\/1471-2474-15-260","article-title":"Significantly reduced radiation dose to operators during percutaneous vertebroplasty using a new cement delivery device","volume":"15","author":"Zhang","year":"2014","journal-title":"BMC Musculoskelet Disord."},{"issue":"20","key":"10.3233\/BMR-170870_ref16","doi-asserted-by":"crossref","first-page":"1717","DOI":"10.1007\/s00198-009-0872-7","article-title":"Clinical and radiological comparison of unipedicular versus bipedicular balloon kyphoplasty for the treatment of vertebral compression fractures","volume":"10","author":"Song","year":"2009","journal-title":"Osteoporos Int."},{"issue":"30","key":"10.3233\/BMR-170870_ref17","first-page":"201","article-title":"Biomechanical comparison of unipedicular versus bipedicular kyphoplasty","volume":"2005","author":"Steinmann","journal-title":"Spine (Phila Pa 1976)"},{"issue":"20","key":"10.3233\/BMR-170870_ref18","doi-asserted-by":"crossref","first-page":"1547","DOI":"10.1007\/s00198-008-0832-7","article-title":"Spinal deformity index (SDI) is a good predictor of incident vertebral fractures","volume":"9","author":"Kerkeni","year":"2009","journal-title":"Osteoporos Int."},{"key":"10.3233\/BMR-170870_ref19","doi-asserted-by":"crossref","unstructured":"Lee S, Kim W, Ko J-K. Multiple pulmonary cement embolism after percutaneous vertebroplasty. QJM. 2013hct079.","DOI":"10.1093\/qjmed\/hct079"}],"container-title":["Journal of Back and Musculoskeletal Rehabilitation"],"original-title":[],"link":[{"URL":"https:\/\/content.iospress.com\/download?id=10.3233\/BMR-170870","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,4,28]],"date-time":"2026-04-28T13:25:33Z","timestamp":1777382733000},"score":1,"resource":{"primary":{"URL":"https:\/\/journals.sagepub.com\/doi\/full\/10.3233\/BMR-170870"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2019,3,11]]},"references-count":19,"journal-issue":{"issue":"2"},"URL":"https:\/\/doi.org\/10.3233\/bmr-170870","relation":{},"ISSN":["1878-6324","1053-8127"],"issn-type":[{"value":"1878-6324","type":"electronic"},{"value":"1053-8127","type":"print"}],"subject":[],"published":{"date-parts":[[2019,3,11]]}}}