{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,4,29]],"date-time":"2026-04-29T12:30:07Z","timestamp":1777465807353,"version":"3.51.4"},"reference-count":22,"publisher":"SAGE Publications","issue":"2","content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["BMR"],"published-print":{"date-parts":[[2022,3,7]]},"abstract":"<jats:p>OBJECTIVE: To compare the clinical outcomes and cement leakage rate between high-viscosity and low-viscosity cement percutaneous vertebroplasty (PVP) with manipulative reduction in the treatment of K\u00fcmmell\u2019s disease (KD). METHOD: PVP using high-viscosity cement (Group H) or low-viscosity cement (Group L) with manipulative reduction was compared in 86 KD patients. Visual Analogue Scale (VAS), Oswestry Disability Index (ODI), vertebral height, kyphosis angle and complications were evaluated and compared preoperative, one day postoperative, and at final follow-up. RESULTS: The VAS score, ODI score, mean anterior and middle vertebral height variation significantly improved in both groups postoperatively. However, there was no significant difference between the two groups considering the above results preoperative and postoperative. Significantly less cement leakage (13.6%) and shorter operative time (35.6 \u00b1 5.1 min) were observed in Group H when compared with Group L (45.2% and 41.1 \u00b1 5.3 min) (p&lt; 0.05). CONCLUSION: The clinical outcomes and radiologic findings of PVP with manipulative reduction was not influenced by cement viscosity. However, high cement viscosity PVP was found to be significant less cement leakage and shorter operative time.<\/jats:p>","DOI":"10.3233\/bmr-191778","type":"journal-article","created":{"date-parts":[[2021,5,25]],"date-time":"2021-05-25T12:34:43Z","timestamp":1621946083000},"page":"301-307","source":"Crossref","is-referenced-by-count":3,"title":["Comparison of high- and low-viscosity cement percutaneous vertebroplasty with manipulative reduction for the treatment of K\u00fcmmell\u2019s disease: A retrospective cohort study"],"prefix":"10.1177","volume":"35","author":[{"given":"Liang","family":"Zhang","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Jingcheng","family":"Wang","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Yongxiang","family":"Wang","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Xinmin","family":"Feng","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"179","reference":[{"key":"10.3233\/BMR-191778_ref1","doi-asserted-by":"crossref","first-page":"180","DOI":"10.1055\/s-0029-1199707","article-title":"Die rarefizierende ostitis der wirbelk\u00f6rper","volume":"21","author":"K\u00fcmmell","year":"1895","journal-title":"Deutsche Med"},{"key":"10.3233\/BMR-191778_ref2","doi-asserted-by":"crossref","first-page":"199","DOI":"10.1111\/os.12609","article-title":"Different performance of intravertebral vacuum clefts in K\u00fcmmell\u2019s disease and relevant treatment strategies","volume":"12","author":"Wang","year":"2020","journal-title":"Orthop Surg"},{"key":"10.3233\/BMR-191778_ref3","doi-asserted-by":"crossref","first-page":"1","DOI":"10.3340\/jkns.2017.0505.010","article-title":"Posttraumatic delayed vertebral collapse: Kummell\u2019s disease","volume":"61","author":"Lim","year":"2018","journal-title":"J Korean Neurosurg Soc"},{"key":"10.3233\/BMR-191778_ref4","doi-asserted-by":"crossref","first-page":"119","DOI":"10.13004\/kjnt.2017.13.2.119","article-title":"Kummell\u2019s disease treated with percutaneous vertebroplasty: minimum 1 year follow-up","volume":"13","author":"Park","year":"2017","journal-title":"Korean J Neurotrauma"},{"key":"10.3233\/BMR-191778_ref5","doi-asserted-by":"crossref","first-page":"S97","DOI":"10.1016\/j.spinee.2014.08.246","article-title":"The cause of delayed neurologic deficits following osteoporotic vertebral pseudoarthrosis","volume":"14","author":"Nakamae","year":"2014","journal-title":"Spine J"},{"key":"10.3233\/BMR-191778_ref6","doi-asserted-by":"crossref","first-page":"577","DOI":"10.4103\/0019-5413.168752","article-title":"Comparison of percutaneous vertebroplasty and percutaneous kyphoplasty for the management of kummell\u2019s disease: a retrospective study","volume":"49","author":"Zhang","year":"2015","journal-title":"Indian J Orthop"},{"key":"10.3233\/BMR-191778_ref7","first-page":"E1021","article-title":"Percutaneous kyphoplasty for kummell disease with severe spinal canal stenosis","volume":"18","author":"Chen","year":"2015","journal-title":"Pain Physician"},{"key":"10.3233\/BMR-191778_ref8","doi-asserted-by":"crossref","first-page":"629","DOI":"10.1302\/0301-620X.88B5.17345","article-title":"Percutaneous vertebroplasty for vertebral compression fractures with and without intravertebral clefts","volume":"88","author":"Ha","year":"2006","journal-title":"J Bone Joint Surg Br"},{"key":"10.3233\/BMR-191778_ref9","doi-asserted-by":"crossref","first-page":"e0184","DOI":"10.1097\/MD.0000000000010184","article-title":"Comparison of high- and low-viscosity cement in the treatment of vertebral compression fractures: a systematic review and meta-analysis","volume":"97","author":"Zhang","year":"2018","journal-title":"Medicine (Baltimore)"},{"key":"10.3233\/BMR-191778_ref10","doi-asserted-by":"crossref","first-page":"e20515","DOI":"10.1097\/MD.0000000000020515","article-title":"Efficacy and safety of high-viscosity cement in percutaneous vertebroplasty for treatment of osteoporotic vertebral compression fractures: a retrospective cohort study","volume":"99","author":"Li","year":"2020","journal-title":"Medicine (Baltimore)"},{"key":"10.3233\/BMR-191778_ref11","doi-asserted-by":"crossref","first-page":"1411","DOI":"10.2214\/ajr.180.5.1801411","article-title":"Percutaneous vertebroplasty: treatment of painful vertebral compression fractures with intraosseous vacuum phenomena","volume":"180","author":"Peh","year":"2003","journal-title":"American Journal of Roentgenology"},{"key":"10.3233\/BMR-191778_ref12","doi-asserted-by":"crossref","first-page":"634","DOI":"10.2214\/AJR.06.0542","article-title":"Importance of intravertebral fracture clefts in vertebroplasty outcome","volume":"188","author":"Wiggins","year":"2007","journal-title":"American Journal of Roentgenology"},{"key":"10.3233\/BMR-191778_ref13","doi-asserted-by":"crossref","first-page":"2175","DOI":"10.1007\/s00198-005-2023-0","article-title":"The severity of vertebral fractures and health-related quality of life in osteoporotic postmenopausal women","volume":"16","author":"Fechtenbaum","year":"2005","journal-title":"Osteoporosis Int"},{"key":"10.3233\/BMR-191778_ref14","doi-asserted-by":"crossref","first-page":"1564","DOI":"10.1359\/jbmr.2000.15.8.1564","article-title":"Consequences of vertebral deformities in older men and women","volume":"15","author":"Pluijm","year":"2000","journal-title":"J Bone Miner Res"},{"key":"10.3233\/BMR-191778_ref15","doi-asserted-by":"crossref","first-page":"e8936","DOI":"10.1097\/MD.0000000000008936","article-title":"Comparison the clinical outcomes and complications of high-viscosity versus low-viscosity in osteoporotic vertebral compression fractures","volume":"96","author":"Guo","year":"2017","journal-title":"Medicine (Baltimore)"},{"key":"10.3233\/BMR-191778_ref16","doi-asserted-by":"crossref","first-page":"161","DOI":"10.1097\/BSD.0000000000000259","article-title":"Clinical efficacy of percutaneous kyphoplasty at the hyperextension position for the treatment of osteoporotic K\u00fcmmell disease","volume":"29","author":"Huang","year":"2016","journal-title":"Clinical Spine Surgery"},{"key":"10.3233\/BMR-191778_ref17","doi-asserted-by":"crossref","first-page":"1109","DOI":"10.1111\/papr.12561","article-title":"Failed percutaneous vertebroplasty due to insufficient correction of intravertebral instability in kummell\u2019s disease: a case report","volume":"17","author":"Kim","year":"2017","journal-title":"Pain Practice"},{"key":"10.3233\/BMR-191778_ref18","doi-asserted-by":"crossref","unstructured":"Yu H, Li Y, Yao X, Lin J, Pan Y, Zhuang H, et al. Application of percutaneous vertebroplasty and percutaneous kyphoplasty in treating K\u00fcmmell\u2019s patients with different stages and postural correction status. Expert. Rev Med Devices 2020; 17: 357-364.","DOI":"10.1080\/17434440.2020.1736039"},{"key":"10.3233\/BMR-191778_ref19","doi-asserted-by":"crossref","first-page":"E88","DOI":"10.1097\/BSD.0b013e31829142bf","article-title":"The existence of intravertebral cleft impact on outcomes of nonacute osteoporotic vertebral compression fractures patients treated by percutaneous kyphoplasty: a comparative study","volume":"27","author":"Wu","year":"2014","journal-title":"J. Spinal Disord Tech"},{"key":"10.3233\/BMR-191778_ref20","doi-asserted-by":"crossref","first-page":"126","DOI":"10.1016\/j.ijsu.2017.05.067","article-title":"An updated comparison of high- and low-viscosity cement vertebro-plasty in the treatment of osteoporotic thoracolumbar vertebral compression fractures: a retrospective cohort study","volume":"43","author":"Zhang","year":"2017","journal-title":"Int J Surg"},{"key":"10.3233\/BMR-191778_ref21","doi-asserted-by":"crossref","first-page":"2562","DOI":"10.1097\/01.brs.0000240695.58651.62","article-title":"High-viscosity cement significantly enhances uniformity of cement filling in vertebroplasty: an experimental model and study on cement leakage","volume":"31","author":"Baroud","year":"2006","journal-title":"Spine"},{"key":"10.3233\/BMR-191778_ref22","first-page":"36","article-title":"A comparative study of high-viscosity cement percutaneous vertebroplasty vs. low-viscosity cement percutaneous kyphoplasty for treatment of osteoporotic vertebral compression fractures","author":"Sun","year":"2016","journal-title":"J Huazhong Univ Sci Technol Med Sci"}],"container-title":["Journal of Back and Musculoskeletal Rehabilitation"],"original-title":[],"link":[{"URL":"https:\/\/content.iospress.com\/download?id=10.3233\/BMR-191778","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,4,28]],"date-time":"2026-04-28T13:26:43Z","timestamp":1777382803000},"score":1,"resource":{"primary":{"URL":"https:\/\/journals.sagepub.com\/doi\/full\/10.3233\/BMR-191778"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2022,3,7]]},"references-count":22,"journal-issue":{"issue":"2"},"URL":"https:\/\/doi.org\/10.3233\/bmr-191778","relation":{},"ISSN":["1878-6324","1053-8127"],"issn-type":[{"value":"1878-6324","type":"electronic"},{"value":"1053-8127","type":"print"}],"subject":[],"published":{"date-parts":[[2022,3,7]]}}}