{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,4,29]],"date-time":"2026-04-29T12:33:42Z","timestamp":1777466022500,"version":"3.51.4"},"reference-count":32,"publisher":"SAGE Publications","issue":"5","license":[{"start":{"date-parts":[[2023,9,1]],"date-time":"2023-09-01T00:00:00Z","timestamp":1693526400000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/journals.sagepub.com\/page\/policies\/text-and-data-mining-license"}],"content-domain":{"domain":["journals.sagepub.com"],"crossmark-restriction":true},"short-container-title":["Journal of Back and Musculoskeletal Rehabilitation"],"published-print":{"date-parts":[[2023,9]]},"abstract":"<jats:sec>\n                    <jats:title>BACKGROUND:<\/jats:title>\n                    <jats:p>In cervicothoracic junction, the use of strong fixation device such as pedicle screw placement is often needed.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>OBJECTIVE:<\/jats:title>\n                    <jats:p>The current study aimed to evaluate the accuracy and safety of pedicle screw placement using stress conduction analysis in the clinical application.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>METHODS:<\/jats:title>\n                    <jats:p>We retrospectively collected patients who underwent pedicle screw internal fixation in cervicothoracic junction. Patients were divided into conventional nail placement (Group A) and modified pedicle screw implantation under guidance of stress analysis (Group B) according to the methods of pedicle screw placement. The accuracy of pedicle screw placement was assessed by computed tomography (CT) examination, and the success rate was calculated.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>RESULTS:<\/jats:title>\n                    <jats:p>\n                      A total of 80 patients who underwent pedicle screw internal fixation in cervicothoracic junction were included. There were no obvious differences in baseline characteristics between two groups. The success rate of total screw placement, cervical spine screw placement and upper thoracic spine screw placement in Group B was higher than those in Group A (\n                      <jats:inline-formula>\n                        <mml:math xmlns:mml=\"http:\/\/www.w3.org\/1998\/Math\/MathML\" alttext=\"P&lt;\" display=\"inline\" overflow=\"scroll\">\n                          <mml:mrow>\n                            <mml:mi>P<\/mml:mi>\n                            <mml:mo>&lt;<\/mml:mo>\n                            <mml:mi\/>\n                          <\/mml:mrow>\n                        <\/mml:math>\n                      <\/jats:inline-formula>\n                      0.001,\n                      <jats:inline-formula>\n                        <mml:math xmlns:mml=\"http:\/\/www.w3.org\/1998\/Math\/MathML\" alttext=\"P=\" display=\"inline\" overflow=\"scroll\">\n                          <mml:mrow>\n                            <mml:mi>P<\/mml:mi>\n                            <mml:mo>=<\/mml:mo>\n                            <mml:mi\/>\n                          <\/mml:mrow>\n                        <\/mml:math>\n                      <\/jats:inline-formula>\n                      0.005,\n                      <jats:inline-formula>\n                        <mml:math xmlns:mml=\"http:\/\/www.w3.org\/1998\/Math\/MathML\" alttext=\"P=\" display=\"inline\" overflow=\"scroll\">\n                          <mml:mrow>\n                            <mml:mi>P<\/mml:mi>\n                            <mml:mo>=<\/mml:mo>\n                            <mml:mi\/>\n                          <\/mml:mrow>\n                        <\/mml:math>\n                      <\/jats:inline-formula>\n                      0.008). Additionally, Heary Grade I in the Group B was higher than Group A (\n                      <jats:inline-formula>\n                        <mml:math xmlns:mml=\"http:\/\/www.w3.org\/1998\/Math\/MathML\" alttext=\"P=\" display=\"inline\" overflow=\"scroll\">\n                          <mml:mrow>\n                            <mml:mi>P<\/mml:mi>\n                            <mml:mo>=<\/mml:mo>\n                            <mml:mi\/>\n                          <\/mml:mrow>\n                        <\/mml:math>\n                      <\/jats:inline-formula>\n                      0.001).\n                    <\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>CONCLUSION:<\/jats:title>\n                    <jats:p>Stress analysis-guided technique can increase the accuracy of pedicle screw placement. Importantly, it meets the requirements of internal fixation of the cervicothoracic junction.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.3233\/bmr-220154","type":"journal-article","created":{"date-parts":[[2023,6,20]],"date-time":"2023-06-20T11:09:04Z","timestamp":1687259344000},"page":"1087-1094","update-policy":"https:\/\/doi.org\/10.1177\/sage-journals-update-policy","source":"Crossref","is-referenced-by-count":0,"title":["Modified pedicle screw fixation under guidance of stress analysis for cervicothoracic junction: Surgical technique and outcomes"],"prefix":"10.1177","volume":"36","author":[{"given":"Chuanjie","family":"Jiang","sequence":"first","affiliation":[{"name":"Shandong Wendeng Orthopedic and Traumatic Hospital","place":["China"]}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Yongjun","family":"Yang","sequence":"additional","affiliation":[{"name":"Shandong Wendeng Orthopedic and Traumatic Hospital","place":["China"]}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Jianlin","family":"Yu","sequence":"additional","affiliation":[{"name":"Shandong Wendeng Orthopedic and Traumatic Hospital","place":["China"]}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Jiping","family":"Zhou","sequence":"additional","affiliation":[{"name":"Shandong Wendeng Orthopedic and Traumatic Hospital","place":["China"]}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Haipeng","family":"Lin","sequence":"additional","affiliation":[{"name":"Shandong Wendeng Orthopedic and Traumatic Hospital","place":["China"]}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Xiuyang","family":"Duan","sequence":"additional","affiliation":[{"name":"Shandong Wendeng Orthopedic and Traumatic Hospital","place":["China"]}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Jinjian","family":"Li","sequence":"additional","affiliation":[{"name":"Shandong Wendeng Orthopedic and Traumatic Hospital","place":["China"]}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"179","published-online":{"date-parts":[[2023,9]]},"reference":[{"key":"e_1_3_3_2_2","doi-asserted-by":"publisher","DOI":"10.1097\/00002517-199912000-00012"},{"key":"e_1_3_3_3_2","doi-asserted-by":"publisher","DOI":"10.4103\/jcvjs.JCVJS_177_20"},{"key":"e_1_3_3_4_2","doi-asserted-by":"publisher","DOI":"10.1097\/SCS.0000000000006097"},{"key":"e_1_3_3_5_2","first-page":"219256822199479","article-title":"Comparing Combined Anterior and Posterior to Posterior-Only Decompression and Fusion Crossing the Cervico-Thoracic Junction in Octogenarians","author":"Ishak B","year":"2021","unstructured":"IshakB Abdul-JabbarA. Comparing Combined Anterior and Posterior to Posterior-Only Decompression and Fusion Crossing the Cervico-Thoracic Junction in Octogenarians. Global Spine J. 2021; 2192568221994793.","journal-title":"Global Spine J."},{"key":"e_1_3_3_6_2","doi-asserted-by":"publisher","DOI":"10.1097\/00007632-199508150-00007"},{"key":"e_1_3_3_7_2","doi-asserted-by":"publisher","DOI":"10.3171\/foc.2004.16.1.11"},{"key":"e_1_3_3_8_2","doi-asserted-by":"publisher","DOI":"10.1097\/00007632-199103001-00010"},{"key":"e_1_3_3_9_2","doi-asserted-by":"publisher","DOI":"10.1097\/BRS.0000000000003845"},{"key":"e_1_3_3_10_2","first-page":"219256822110156","article-title":"Subaxial Cervical Pedicular Screw Insertion via the Nonanatomic Axis: Technical Notes and Preliminary Clinical Report","author":"Wang Y","year":"2021","unstructured":"WangY HuB WuJ ChenW. Subaxial Cervical Pedicular Screw Insertion via the Nonanatomic Axis: Technical Notes and Preliminary Clinical Report. Global Spine J. 2021; 21925682211015649.","journal-title":"Global Spine J."},{"key":"e_1_3_3_11_2","doi-asserted-by":"publisher","DOI":"10.31616\/asj.2018.12.4.726"},{"key":"e_1_3_3_12_2","article-title":"Accuracy of pedicle screw placement using patient-specific template guide system","author":"Fujita R","year":"2021","unstructured":"FujitaR OdaI TakeuchiH OshimaS FujiyaM YaharaY, et al. Accuracy of pedicle screw placement using patient-specific template guide system. J Orthop Sci. 2021.","journal-title":"J Orthop Sci."},{"issue":"23","key":"e_1_3_3_13_2","first-page":"10950","article-title":"Advances in research and new methods of thoracic pedicle screw placement","volume":"7","author":"Qi DB","year":"2013","unstructured":"QiDB ZhangYG. Advances in research and new methods of thoracic pedicle screw placement. Chinese Journal of Clinicians(Electronic Edition). 2013; 7(23): 10950-2.","journal-title":"Chinese Journal of Clinicians(Electronic Edition)."},{"issue":"1","key":"e_1_3_3_14_2","article-title":"Design and Application of a Novel Patient-Specific Three-Dimensional Printed Drill Navigational Guiding in Atlantoaxial Pedicle Screw Placement","volume":"114","author":"Pu X","year":"2018","unstructured":"PuX YinM MaJ LiuY ChenG HuangQ, et al. Design and Application of a Novel Patient-Specific Three-Dimensional Printed Drill Navigational Guiding in Atlantoaxial Pedicle Screw Placement. World Neurosurg. 2018; 114(e1-e10).","journal-title":"World Neurosurg."},{"key":"e_1_3_3_15_2","doi-asserted-by":"publisher","DOI":"10.3233\/XST-190566"},{"key":"e_1_3_3_16_2","doi-asserted-by":"publisher","DOI":"10.1007\/s10856-019-6320-0"},{"key":"e_1_3_3_17_2","doi-asserted-by":"publisher","DOI":"10.1097\/00007632-200004150-00011"},{"key":"e_1_3_3_18_2","doi-asserted-by":"publisher","DOI":"10.4103\/0028-3886.22622"},{"key":"e_1_3_3_19_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.jbiomech.2016.06.027"},{"issue":"100733","key":"e_1_3_3_20_2","article-title":"Reduced cortical bone thickness increases stress and strain in the female femoral diaphysis analyzed by a CT-based finite element method: Implications for the anatomical background of fatigue fracture of the femur","volume":"13","author":"Endo D","year":"2020","unstructured":"EndoD Ogami-TakamuraK ImamuraT SaikiK MuraiK OkamotoK, et al. Reduced cortical bone thickness increases stress and strain in the female femoral diaphysis analyzed by a CT-based finite element method: Implications for the anatomical background of fatigue fracture of the femur. Bone Rep. 2020; 13(100733).","journal-title":"Bone Rep."},{"issue":"4","key":"e_1_3_3_21_2","first-page":"325","article-title":"Thoracic pedicle screws: postoperative computerized tomography scanning assessment","volume":"100","author":"Heary RF","year":"2004","unstructured":"HearyRF BonoCM BlackM. Thoracic pedicle screws: postoperative computerized tomography scanning assessment. J Neurosurg. 2004; 100(4 Suppl Spine): 325-31.","journal-title":"J Neurosurg."},{"key":"e_1_3_3_22_2","doi-asserted-by":"publisher","DOI":"10.3340\/jkns.2010.48.1.46"},{"key":"e_1_3_3_23_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.spinee.2013.03.029"},{"key":"e_1_3_3_24_2","doi-asserted-by":"publisher","DOI":"10.1097\/01.blo.0000150321.81088.ab"},{"key":"e_1_3_3_25_2","doi-asserted-by":"publisher","DOI":"10.1007\/s00586-011-2011-3"},{"key":"e_1_3_3_26_2","doi-asserted-by":"publisher","DOI":"10.1007\/s00701-017-3289-7"},{"key":"e_1_3_3_27_2","doi-asserted-by":"publisher","DOI":"10.3171\/SPI.2008.9.11.450"},{"key":"e_1_3_3_28_2","doi-asserted-by":"publisher","DOI":"10.3171\/2014.7.SPINE1489"},{"key":"e_1_3_3_29_2","doi-asserted-by":"publisher","DOI":"10.1097\/01.brs.0000150482.26918.d8"},{"key":"e_1_3_3_30_2","doi-asserted-by":"publisher","DOI":"10.3171\/spi.2006.5.6.520"},{"key":"e_1_3_3_31_2","doi-asserted-by":"publisher","DOI":"10.1111\/os.12599"},{"key":"e_1_3_3_32_2","doi-asserted-by":"publisher","DOI":"10.1097\/BRS.0000000000002876"},{"key":"e_1_3_3_33_2","doi-asserted-by":"publisher","DOI":"10.1093\/neuros\/nyaa078"}],"container-title":["Journal of Back and Musculoskeletal Rehabilitation"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/journals.sagepub.com\/doi\/pdf\/10.3233\/BMR-220154","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/journals.sagepub.com\/doi\/full-xml\/10.3233\/BMR-220154","content-type":"application\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/journals.sagepub.com\/doi\/pdf\/10.3233\/BMR-220154","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,4,28]],"date-time":"2026-04-28T13:27:26Z","timestamp":1777382846000},"score":1,"resource":{"primary":{"URL":"https:\/\/journals.sagepub.com\/doi\/10.3233\/BMR-220154"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2023,9]]},"references-count":32,"journal-issue":{"issue":"5","published-print":{"date-parts":[[2023,9]]}},"alternative-id":["10.3233\/BMR-220154"],"URL":"https:\/\/doi.org\/10.3233\/bmr-220154","relation":{},"ISSN":["1053-8127","1878-6324"],"issn-type":[{"value":"1053-8127","type":"print"},{"value":"1878-6324","type":"electronic"}],"subject":[],"published":{"date-parts":[[2023,9]]}}}