{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,4,29]],"date-time":"2026-04-29T21:17:40Z","timestamp":1777497460542,"version":"3.51.4"},"reference-count":18,"publisher":"SAGE Publications","issue":"1-2","content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["CH"],"published-print":{"date-parts":[[2024,2,22]]},"abstract":"<jats:p>BACKGROUND: The range of software available to radiologists has increased enormously with the advancement of AI. A good example of this is software to determine ASPECTS in the treatment of potential stroke patients. OBJECTIVE: In this study, two software packages (eASPECTS from Brainomix and VIA_ASPECTS from Siemens) were tested and compared for their performance in the daily clinical routine of a maximum care provider with a 24\/7 stroke unit. METHODS: A total of 637 noncontrast CT images were obtained from consecutive patients with suspected stroke, of whom 73 were finally diagnosed with MCA infarction. Differences in agreement and quantification of agreement were analysed, as well as the correlation and sensitivity, specificity and accuracy compared to raters. RESULTS: Compared to VIA_ASPECTS, eASPECTS shows good agreement and strong correlation with the raters. VIA_ASPECTS has lower accuracy and low specificity than eASPECTS but a higher sensitivity. CONCLUSION: Both software products have the potential to be decision support tools for radiologists. There are, however, differences between the two software products in terms of their intended use.<\/jats:p>","DOI":"10.3233\/ch-238105","type":"journal-article","created":{"date-parts":[[2023,8,25]],"date-time":"2023-08-25T10:32:31Z","timestamp":1692959551000},"page":"109-119","source":"Crossref","is-referenced-by-count":1,"title":["Performance evaluation of two different software programs for automated ASPECTS scoring in patients with suspected stroke"],"prefix":"10.1177","volume":"86","author":[{"given":"Carolina","family":"R\u00edo B\u00e1rtulos","sequence":"first","affiliation":[{"name":"Insitut f\u00fcr R\u00f6ntgendiagnostik und Nuklearmedizin, St\u00e4dtisches Klinikum Braunschweig gGmbH, Braunschweig, Germany"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Lukas","family":"Pirl","sequence":"additional","affiliation":[{"name":"Insitut f\u00fcr R\u00f6ntgendiagnostik und Nuklearmedizin, St\u00e4dtisches Klinikum Braunschweig gGmbH, Braunschweig, Germany"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Dennis","family":"Lier","sequence":"additional","affiliation":[{"name":"Insitut f\u00fcr R\u00f6ntgendiagnostik und Nuklearmedizin, St\u00e4dtisches Klinikum Braunschweig gGmbH, Braunschweig, Germany"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Mathis","family":"Planert","sequence":"additional","affiliation":[{"name":"Insitut f\u00fcr R\u00f6ntgendiagnostik und Nuklearmedizin, St\u00e4dtisches Klinikum Braunschweig gGmbH, Braunschweig, Germany"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Juliane","family":"Hohmann","sequence":"additional","affiliation":[{"name":"Insitut f\u00fcr R\u00f6ntgendiagnostik und Nuklearmedizin, St\u00e4dtisches Klinikum Braunschweig gGmbH, Braunschweig, Germany"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Abdelouahed","family":"El Mountassir","sequence":"additional","affiliation":[{"name":"Insitut f\u00fcr R\u00f6ntgendiagnostik und Nuklearmedizin, St\u00e4dtisches Klinikum Braunschweig gGmbH, Braunschweig, Germany"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Mohamed","family":"El Anwar","sequence":"additional","affiliation":[{"name":"Insitut f\u00fcr R\u00f6ntgendiagnostik und Nuklearmedizin, St\u00e4dtisches Klinikum Braunschweig gGmbH, Braunschweig, Germany"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Philipp","family":"Wiggermann","sequence":"additional","affiliation":[{"name":"Insitut f\u00fcr R\u00f6ntgendiagnostik und Nuklearmedizin, St\u00e4dtisches Klinikum Braunschweig gGmbH, Braunschweig, Germany"}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"179","reference":[{"issue":"6","key":"10.3233\/CH-238105_ref1","doi-asserted-by":"crossref","first-page":"3797","DOI":"10.1007\/s00330-021-07892-z","article-title":"Artificial intelligence in radiology: 100 commercially available products and their scientific evidence","volume":"31","author":"van Leeuwen","year":"2021","journal-title":"Eur Radiol"},{"key":"10.3233\/CH-238105_ref2","doi-asserted-by":"publisher","DOI":"10.3233\/CH-239102"},{"issue":"3","key":"10.3233\/CH-238105_ref3","doi-asserted-by":"crossref","first-page":"343","DOI":"10.3233\/CH-170275","article-title":"A two-stage multi-view learning framework based computer-aided diagnosis of liver tumors with contrast enhanced ultrasound images","volume":"69","author":"Guo","year":"2018","journal-title":"Clin Hemorheol Microcirc"},{"issue":"2","key":"10.3233\/CH-238105_ref4","doi-asserted-by":"crossref","first-page":"208","DOI":"10.1053\/j.ro.2023.02.006","article-title":"A Practical Guide for AI Algorithm Selection for the Radiology Department","volume":"58","author":"Forghani","year":"2023","journal-title":"Semin Roentgenol"},{"issue":"9216","key":"10.3233\/CH-238105_ref5","doi-asserted-by":"crossref","first-page":"1670","DOI":"10.1016\/S0140-6736(00)02237-6","article-title":"Validity and reliability of a quantitative computed tomography score in predicting outcome of hyperacute stroke before thrombolytic therapy","volume":"355","author":"Barber","year":"2000","journal-title":"The Lancet"},{"issue":"8","key":"10.3233\/CH-238105_ref6","first-page":"1534","article-title":"Use of the Alberta Stroke Program Early CT Score (ASPECTS) for assessing CT scans in patients with acute stroke","volume":"22","author":"Pexman","year":"2001","journal-title":"AJNR Am J Neuroradiol"},{"issue":"1","key":"10.3233\/CH-238105_ref7","doi-asserted-by":"crossref","first-page":"6","DOI":"10.1177\/2396987319832140","article-title":"European Stroke Organisation (ESO) - European Society for Minimally Invasive Neurological Therapy (ESMINT) Guidelines on Mechanical Thrombectomy in Acute Ischaemic StrokeEndorsed by Stroke Alliance for Europe (SAFE)","volume":"4","author":"Turc","year":"2019","journal-title":"Eur Stroke J"},{"issue":"7","key":"10.3233\/CH-238105_ref8","doi-asserted-by":"crossref","first-page":"664","DOI":"10.1136\/neurintsurg-2018-014250","article-title":"Influence of ASPECTS and endovascular thrombectomy in acute ischemic stroke: a meta-analysis","volume":"11","author":"Phan","year":"2019","journal-title":"J Neurointerv Surg"},{"issue":"6","key":"10.3233\/CH-238105_ref9","doi-asserted-by":"crossref","first-page":"615","DOI":"10.1177\/1747493016681020","article-title":"e-ASPECTS software is non-inferior to neuroradiologists in applying the ASPECT score to computed tomography scans of acute ischemic stroke patients","volume":"12","author":"Nagel","year":"2017","journal-title":"Int J Stroke"},{"issue":"3","key":"10.3233\/CH-238105_ref10","doi-asserted-by":"crossref","first-page":"249","DOI":"10.1212\/WNL.0000000000002860","article-title":"Early CT changes in patients admitted for thrombectomy: Intrarater and interrater agreement","volume":"87","author":"Farzin","year":"2016","journal-title":"Neurology"},{"key":"10.3233\/CH-238105_ref11","doi-asserted-by":"crossref","unstructured":"Landis JR , Koch GG . The Measurement of Observer Agreement for Categorical Data. Biometrics. 1977;33(1).","DOI":"10.2307\/2529310"},{"issue":"1","key":"10.3233\/CH-238105_ref13","doi-asserted-by":"crossref","first-page":"55","DOI":"10.3233\/CH-219106","article-title":"Dynamic perfusion analysis in acute ischemic stroke: A comparative study of two different softwares","volume":"79","author":"Krusche","year":"2021","journal-title":"Clin Hemorheol Microcirc"},{"issue":"4","key":"10.3233\/CH-238105_ref14","doi-asserted-by":"crossref","first-page":"438","DOI":"10.1177\/1747493016632244","article-title":"Performance of e-ASPECTS software in comparison to that of stroke physicians on assessing CT scans of acute ischemic stroke patients","volume":"11","author":"Herweh","year":"2016","journal-title":"Int J Stroke"},{"issue":"8","key":"10.3233\/CH-238105_ref15","doi-asserted-by":"crossref","first-page":"1594","DOI":"10.3174\/ajnr.A5236","article-title":"e-ASPECTS Correlates with and Is Predictive of Outcome after Mechanical Thrombectomy","volume":"38","author":"Pfaff","year":"2017","journal-title":"AJNR Am J Neuroradiol"},{"issue":"10","key":"10.3233\/CH-238105_ref16","doi-asserted-by":"crossref","first-page":"106702","DOI":"10.1016\/j.jstrokecerebrovasdis.2022.106702","article-title":"Comparison of automated ASPECTS, large vessel occlusion detection and CTP analysis provided by Brainomix and Rapid AI in patients with suspected ischaemic stroke","volume":"31","author":"Mallon","year":"2022","journal-title":"J Stroke Cerebrovasc Dis"},{"issue":"12","key":"10.3233\/CH-238105_ref17","doi-asserted-by":"crossref","first-page":"1267","DOI":"10.1007\/s00234-018-2098-x","article-title":"Automated ASPECT rating: comparison between the Frontier ASPECT Score software and the Brainomix software","volume":"60","author":"Goebel","year":"2018","journal-title":"Neuroradiology"},{"issue":"10","key":"10.3233\/CH-238105_ref18","doi-asserted-by":"crossref","first-page":"1231","DOI":"10.1007\/s00234-020-02439-3","article-title":"Automated ASPECT scoring in acute ischemic stroke: comparison of three software tools","volume":"62","author":"Hoelter","year":"2020","journal-title":"Neuroradiology"},{"issue":"1","key":"10.3233\/CH-238105_ref19","doi-asserted-by":"crossref","first-page":"141","DOI":"10.1148\/radiol.2019181228","article-title":"Automated Calculation of the Alberta Stroke Program Early CT Score: Feasibility and Reliability","volume":"291","author":"Maegerlein","year":"2019","journal-title":"Radiology"}],"container-title":["Clinical Hemorheology and Microcirculation"],"original-title":[],"link":[{"URL":"https:\/\/content.iospress.com\/download?id=10.3233\/CH-238105","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,4,28]],"date-time":"2026-04-28T15:06:31Z","timestamp":1777388791000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.medra.org\/servlet\/aliasResolver?alias=iospress&doi=10.3233\/CH-238105"}},"subtitle":[],"editor":[{"given":"L.","family":"Prantl","sequence":"additional","affiliation":[],"role":[{"role":"editor","vocabulary":"crossref"}]},{"given":"A.","family":"Krueger-Genge","sequence":"additional","affiliation":[],"role":[{"role":"editor","vocabulary":"crossref"}]},{"given":"F.","family":"Jung","sequence":"additional","affiliation":[],"role":[{"role":"editor","vocabulary":"crossref"}]}],"short-title":[],"issued":{"date-parts":[[2024,2,22]]},"references-count":18,"journal-issue":{"issue":"1-2"},"URL":"https:\/\/doi.org\/10.3233\/ch-238105","relation":{},"ISSN":["1386-0291","1875-8622"],"issn-type":[{"value":"1386-0291","type":"print"},{"value":"1875-8622","type":"electronic"}],"subject":[],"published":{"date-parts":[[2024,2,22]]}}}