{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,5,4]],"date-time":"2026-05-04T01:09:59Z","timestamp":1777856999672,"version":"3.51.4"},"reference-count":15,"publisher":"SAGE Publications","issue":"2","content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["JND"],"published-print":{"date-parts":[[2021,3,2]]},"abstract":"<jats:p>Fatigability is the hallmark of myasthenia gravis (MG). It is not clear, however, whether there is an analogous increase in jitter during the course of a single fiber electromyography (SFEMG) session. The individual jitter values of all potentials of 76 normal and 44 myasthenic orbicularis oculi muscles were assigned a rank number according to their temporal order in which they were collected and linear regression was performed to determine if the slope of the regression line was significantly different from zero. Control and MG subjects displayed rather flat linear regression lines with non-significant positive or negative slopes. Accordingly, ROC analysis yielded areas under the curve near 0.5. We conclude that there is no systematic jitter increase during the collection of 20 potential pairs in a typical SFEMG session.<\/jats:p>","DOI":"10.3233\/jnd-200599","type":"journal-article","created":{"date-parts":[[2021,1,12]],"date-time":"2021-01-12T19:46:52Z","timestamp":1610480812000},"page":"295-298","source":"Crossref","is-referenced-by-count":2,"title":["Jitter Remains Stable Throughout a Single Fiber EMG Session in Healthy and Myasthenic Muscles"],"prefix":"10.1177","volume":"8","author":[{"given":"Evangelos","family":"Anagnostou","sequence":"first","affiliation":[{"name":"Department of Neurology, University of Athens, Eginition Hospital, Athens, Greece"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Panagiota","family":"Dimopoulou","sequence":"additional","affiliation":[{"name":"Department of Neurology, University of Athens, Eginition Hospital, Athens, Greece"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Vasiliki","family":"Zouvelou","sequence":"additional","affiliation":[{"name":"Department of Neurology, University of Athens, Eginition Hospital, Athens, Greece"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Nikolaos","family":"Karandreas","sequence":"additional","affiliation":[{"name":"Department of Neurology, University of Athens, Eginition Hospital, Athens, Greece"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Thomas","family":"Zambelis","sequence":"additional","affiliation":[{"name":"Department of Neurology, University of Athens, Eginition Hospital, Athens, Greece"}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"179","reference":[{"issue":"suppl","key":"10.3233\/JND-200599_ref1","doi-asserted-by":"crossref","first-page":"S15","DOI":"10.1002\/mus.10141","article-title":"Clinical impact of single-fiber electromyography","volume":"11","author":"Sanders","year":"2002","journal-title":"Muscle Nerve"},{"issue":"4","key":"10.3233\/JND-200599_ref2","doi-asserted-by":"crossref","first-page":"489","DOI":"10.1002\/mus.21156","article-title":"Correlating extent of neuromuscular instability with acetylcholine receptor antibodies","volume":"39","author":"Farrugia","year":"2009","journal-title":"Muscle Nerve"},{"key":"10.3233\/JND-200599_ref3","doi-asserted-by":"crossref","first-page":"163","DOI":"10.3233\/JND-140020","article-title":"Predictive Value of Electrophysiology for Presence of Thymic Pathology in Myasthenia Gravis","volume":"1","author":"Gosavi","year":"2014","journal-title":"J Neuromuscul Dis"},{"key":"10.3233\/JND-200599_ref4","doi-asserted-by":"crossref","first-page":"469","DOI":"10.1097\/WNP.0000000000000285","article-title":"Diagnostic Accuracy of Single Fiber Electromography for Myasthenia Gravis in Patients Followed Longitudinally","volume":"33","author":"Morren","year":"2016","journal-title":"J Clin Neurophysiol"},{"key":"10.3233\/JND-200599_ref5","doi-asserted-by":"crossref","first-page":"447","DOI":"10.1016\/B978-0-444-63432-0.00024-4","article-title":"Neuromuscular junction disorders","volume":"133","author":"Verschuuren","year":"2016","journal-title":"Handb Clin Neurol"},{"key":"10.3233\/JND-200599_ref6","doi-asserted-by":"crossref","first-page":"303","DOI":"10.1016\/B978-0-444-64032-1.00019-9","article-title":"Single fiber electromyography","volume":"160","author":"Juel","year":"2019","journal-title":"Handb Clin Neurol"},{"key":"10.3233\/JND-200599_ref7","doi-asserted-by":"crossref","first-page":"1417","DOI":"10.1016\/j.clinph.2019.04.005","article-title":"Guidelines for single fiber EMG","volume":"130","author":"Sanders","year":"2019","journal-title":"Clin Neurophysiol"},{"key":"10.3233\/JND-200599_ref8","doi-asserted-by":"crossref","first-page":"351","DOI":"10.1002\/mus.24750","article-title":"Reference values for jitter recorded by concentric needle electrodes in healthy controls: A multicenter study","volume":"53","author":"St\u00e5lberg","year":"2016","journal-title":"Muscle Nerve"},{"key":"10.3233\/JND-200599_ref9","doi-asserted-by":"crossref","first-page":"207","DOI":"10.1016\/0013-4694(85)90032-X","article-title":"The effect of continuous voluntary activation on neuromuscular transmission: A SFEMG study of myasthenia gravis and anterior horn cell disorders","volume":"60","author":"Ingram","year":"1985","journal-title":"Electroencephalogr Clin Neurophysiol"},{"key":"10.3233\/JND-200599_ref10","doi-asserted-by":"crossref","first-page":"715","DOI":"10.1002\/(SICI)1097-4598(200005)23:5<715::AID-MUS8>3.0.CO;2-V","article-title":"Concentric needle electrode for neuromuscular jitter analysis","volume":"23","author":"Ertas","year":"2000","journal-title":"Muscle Nerve"},{"key":"10.3233\/JND-200599_ref11","doi-asserted-by":"crossref","first-page":"226","DOI":"10.1002\/mus.880140305","article-title":"Single motor end-plates in myasthenia gravis and LEMS at different firing rates","volume":"14","author":"Trontelj","year":"1991","journal-title":"Muscle Nerve"},{"key":"10.3233\/JND-200599_ref12","first-page":"256","article-title":"The effect of firing rate on neuromuscular jitter in Lambert-Eaton myasthenic syndrome","volume":"15","author":"Sanders","year":"1992","journal-title":"Muscle Nerve"},{"key":"10.3233\/JND-200599_ref13","doi-asserted-by":"crossref","first-page":"262","DOI":"10.1097\/00004691-199805000-00011","article-title":"Motor end-plate jitter in myasthenia gravis at different firing rates","volume":"15","author":"Lin","year":"1998","journal-title":"J Clin Neurophysiol"},{"key":"10.3233\/JND-200599_ref14","doi-asserted-by":"crossref","first-page":"408","DOI":"10.1097\/WNP.0000000000000402","article-title":"Recording Fewer Than 20 Potential Pairs With SFEMG May Suffice for the Diagnosis of Myasthenia Gravis","volume":"34","author":"Abraham","year":"2017","journal-title":"J Clin Neurophysiol"},{"key":"10.3233\/JND-200599_ref15","doi-asserted-by":"crossref","first-page":"486","DOI":"10.1002\/mus.22340","article-title":"Application of futility analysis to refine jitter recordings in myasthenia gravis","volume":"45","author":"Narayanaswami","year":"2012","journal-title":"Muscle Nerve"}],"container-title":["Journal of Neuromuscular Diseases"],"original-title":[],"link":[{"URL":"https:\/\/content.iospress.com\/download?id=10.3233\/JND-200599","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,4,29]],"date-time":"2026-04-29T23:49:36Z","timestamp":1777506576000},"score":1,"resource":{"primary":{"URL":"https:\/\/journals.sagepub.com\/doi\/full\/10.3233\/JND-200599"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2021,3,2]]},"references-count":15,"journal-issue":{"issue":"2"},"URL":"https:\/\/doi.org\/10.3233\/jnd-200599","relation":{},"ISSN":["2214-3599","2214-3602"],"issn-type":[{"value":"2214-3599","type":"print"},{"value":"2214-3602","type":"electronic"}],"subject":[],"published":{"date-parts":[[2021,3,2]]}}}