{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,8,19]],"date-time":"2026-08-19T18:07:30Z","timestamp":1787162850151,"version":"build-2736575974"},"reference-count":8,"publisher":"SAGE Publications","issue":"2","content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["NPM"],"published-print":{"date-parts":[[2022,4,12]]},"abstract":"<jats:p>BACKGROUND: To compare oxygen saturation (SpO2) and heart rate (HR) recorded by a reference wired pulse oximeter to a wireless pulse oximeter in inpatient neonates. METHODS: Term infants born\u226537\u200a+\u200a0 weeks and preterm infants born\u226435\u200a+\u200a0 weeks gestation were enrolled and time-matched data pairs were obtained. The primary outcome was intraclass correlation coefficient and r-values between the two oximeters for heart rate and oxygen saturation. RESULTS: Thirty term and 20 preterm neonates were enrolled. There was a high degree of correlation between the two oximeters for HR (r\u200a=\u200a0.926) among all 50 infants, and excellent interclass correlation (ICC\u200a=\u200a0.961), but there were no bradycardia episodes in either term or preterm infants. There was a lesser degree of correlation for SpO2 values in the term and preterm groups (r\u200a=\u200a0.242; 0.521, respectively) along with moderate interclass correlation (ICC\u200a=\u200a0.719) but few episodes of hypoxemia\u226490% occurred in enrolled subjects. CONCLUSIONS: There were no significant differences between the wireless and reference wired oximeters for assessing HR. There was less correlation between the two oximeters for monitoring SpO2 in both the term and preterm group. Wireless pulse oximetry may have practical advantages for use in inpatient neonates, but additional studies are needed that include bradycardia and desaturation events to delineate this question.<\/jats:p>","DOI":"10.3233\/npm-210836","type":"journal-article","created":{"date-parts":[[2022,3,11]],"date-time":"2022-03-11T11:49:29Z","timestamp":1646999369000},"page":"283-289","source":"Crossref","is-referenced-by-count":4,"title":["Inpatient comparison of wireless and wired pulse oximetry in neonates"],"prefix":"10.1177","volume":"15","author":[{"given":"M.D.","family":"Harrell","sequence":"first","affiliation":[{"name":"Neonatal, Perinatal Medicine Fellowship, National Capital Consortium, Bethesda, MD, USA"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"N.R.","family":"Dobson","sequence":"additional","affiliation":[{"name":"Department of Pediatrics, Uniformed Services University, Bethesda, MD, USA"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"C.","family":"Olsen","sequence":"additional","affiliation":[{"name":"Department of Preventive Medicine and Biostatistics, Uniformed Services University, Bethesda, MD, USA"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"A.","family":"Ahmed","sequence":"additional","affiliation":[{"name":"Department of Preventive Medicine and Biostatistics, Uniformed Services University, Bethesda, MD, USA"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"C.E.","family":"Hunt","sequence":"additional","affiliation":[{"name":"Department of Pediatrics, Uniformed Services University, Bethesda, MD, USA"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"179","reference":[{"key":"10.3233\/NPM-210836_ref1","doi-asserted-by":"crossref","first-page":"367","DOI":"10.1136\/bmj.311.7001.367","article-title":"Pulse oximetry: A practical review","volume":"311","author":"Hanning","year":"1995","journal-title":"BMJ"},{"issue":"6","key":"10.3233\/NPM-210836_ref2","doi-asserted-by":"crossref","first-page":"789","DOI":"10.1016\/j.rmed.2013.02.004","article-title":"Pulse oximetry: Understanding its basic principles facilitates appreciation of its limitations","volume":"107","author":"Chan","year":"2013","journal-title":"Respir Med"},{"issue":"7","key":"10.3233\/NPM-210836_ref3","doi-asserted-by":"crossref","first-page":"1008","DOI":"10.1038\/s41372-019-0393-y","article-title":"Development of a single-center quality bundle to prevent sudden unexpected postnatal collapse","volume":"39","author":"Paul","year":"2019","journal-title":"J Perinatol"},{"issue":"1","key":"10.3233\/NPM-210836_ref4","first-page":"e20200251","article-title":"Agreement among four portable wireless pulse oximeters and in-office evaluation of peripheral oxygen saturation","volume":"47","author":"Melo","year":"2020","journal-title":"J Bras Pneumol"},{"issue":"3","key":"10.3233\/NPM-210836_ref5","doi-asserted-by":"crossref","first-page":"418","DOI":"10.1038\/s41591-020-0792-9","article-title":"Skin-interfaced biosensors for advanced wireless physiological monitoring in neonatal and pediatric intensive-care units","volume":"26","author":"Chung","year":"2020","journal-title":"Nat Med"},{"issue":"6","key":"10.3233\/NPM-210836_ref6","first-page":"OC05","article-title":"Comparative evaluation of accuracy of pulse oximeters and factors affecting their performance in a tertiary intensive care unit","volume":"11","author":"Singh","year":"2017","journal-title":"J Clin Diagn Res"},{"issue":"10","key":"10.3233\/NPM-210836_ref7","doi-asserted-by":"crossref","first-page":"770","DOI":"10.4172\/2155-6148.1000770","article-title":"A comparison of wireless pulse oximetry technologies during sustained shivering in post-operative patients","volume":"8","author":"Dixon","year":"2017","journal-title":"J Anesth Clin Res"},{"issue":"7","key":"10.3233\/NPM-210836_ref9","doi-asserted-by":"crossref","first-page":"717","DOI":"10.1001\/jama.2018.9018","article-title":"Accuracy of pulse oximetry-based home baby monitors","volume":"320","author":"Bonafide","year":"2018","journal-title":"JAMA"}],"container-title":["Journal of Neonatal-Perinatal Medicine"],"original-title":[],"link":[{"URL":"https:\/\/content.iospress.com\/download?id=10.3233\/NPM-210836","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,5,1]],"date-time":"2026-05-01T05:41:57Z","timestamp":1777614117000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.medra.org\/servlet\/aliasResolver?alias=iospress&doi=10.3233\/NPM-210836"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2022,4,12]]},"references-count":8,"journal-issue":{"issue":"2"},"URL":"https:\/\/doi.org\/10.3233\/npm-210836","relation":{},"ISSN":["1934-5798","1878-4429"],"issn-type":[{"value":"1934-5798","type":"print"},{"value":"1878-4429","type":"electronic"}],"subject":[],"published":{"date-parts":[[2022,4,12]]}}}