{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,5,4]],"date-time":"2026-05-04T10:28:29Z","timestamp":1777890509471,"version":"3.51.4"},"reference-count":24,"publisher":"SAGE Publications","issue":"5","content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["THC"],"published-print":{"date-parts":[[2017,10,23]]},"DOI":"10.3233\/thc-160487","type":"journal-article","created":{"date-parts":[[2017,11,5]],"date-time":"2017-11-05T10:59:31Z","timestamp":1509879571000},"page":"831-842","source":"Crossref","is-referenced-by-count":4,"title":["Modification of hemodynamics in basilar artery aneurysm by the single and Y stent placement1"],"prefix":"10.1177","volume":"25","author":[{"given":"Tatsuya","family":"Matsuda","sequence":"first","affiliation":[{"name":"Department of Mechanical Science and Engineering, Nagoya University, Nagoya, Japan"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Yasumasa","family":"Ito","sequence":"additional","affiliation":[{"name":"Department of Mechanical Science and Engineering, Nagoya University, Nagoya, Japan"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Kohei","family":"Masunaga","sequence":"additional","affiliation":[{"name":"Department of Mechanical Science and Engineering, Nagoya University, Nagoya, Japan"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Yasuhiko","family":"Sakai","sequence":"additional","affiliation":[{"name":"Department of Mechanical Science and Engineering, Nagoya University, Nagoya, Japan"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Keiko","family":"Irie","sequence":"additional","affiliation":[{"name":"Neurosurgery, Nagoya Kyoritsu Hospital, Nagoya, Japan"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Koji","family":"Iwano","sequence":"additional","affiliation":[{"name":"Department of Mechanical Science and Engineering, Nagoya University, Nagoya, Japan"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Koji","family":"Nagata","sequence":"additional","affiliation":[{"name":"Department of Aerospace Engineering, Nagoya University, Nagoya, Japan"}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"179","reference":[{"key":"10.3233\/THC-160487_ref1","doi-asserted-by":"crossref","first-page":"306","DOI":"10.1016\/j.wneu.2010.05.008","article-title":"Alteration of intra-aneurysmal hemodynamics for flow diversion using enterprise and vision stents","volume":"74","author":"Tremmel","year":"2010","journal-title":"World neurosurgery."},{"key":"10.3233\/THC-160487_ref2","doi-asserted-by":"crossref","first-page":"1980","DOI":"10.3174\/ajnr.A3479","article-title":"Hemodynamics of 8 different configurations of stenting for bifurcation aneurysms","volume":"34","author":"Kono","year":"2013","journal-title":"Am J Neuroradiol."},{"key":"10.3233\/THC-160487_ref3","doi-asserted-by":"crossref","first-page":"440","DOI":"10.1016\/j.jbiomech.2011.12.016","article-title":"Influence of stent configuration on cerebral aneurysm fluid dynamics","volume":"45","author":"Babiker","year":"2012","journal-title":"J Biomech."},{"issue":"3","key":"10.3233\/THC-160487_ref4","doi-asserted-by":"crossref","first-page":"745","DOI":"10.1161\/STROKEAHA.110.593517","article-title":"High shear stress and flow velocity in partially occluded aneurysms prone to recanalization","volume":"42","author":"Luo","year":"2011","journal-title":"Stroke."},{"key":"10.3233\/THC-160487_ref5","doi-asserted-by":"crossref","first-page":"1262","DOI":"10.3174\/ajnr.A2475","article-title":"A novel \u201cY\u201d stent Flow Diversion Technique for the Endovascular Treatment of Bifurcation Aneurysms without Endovascular Coiling","volume":"32","author":"Cekirge","year":"2011","journal-title":"Am J Neuroradiology."},{"key":"10.3233\/THC-160487_ref6","doi-asserted-by":"crossref","first-page":"617","DOI":"10.1227\/NEU.0b013e3182846d9f","article-title":"Y stent Coiling of Basilar Bifur-cation Aneurysms Induces a Dynamic Angular Vascular Remodeling With Alteration of the Apical Wall Shear Stress Pattern","volume":"72","author":"Gao","year":"2013","journal-title":"Neurosurgery."},{"key":"10.3233\/THC-160487_ref7","doi-asserted-by":"crossref","first-page":"e108033","DOI":"10.1371\/journal.pone.0108033","article-title":"Hemodynamic Effects of Stent Struts versus Straightening of Vessels in Stent-Assisted Coil Embolization for Sidewall Cerebral Aneurysms","volume":"9","author":"Kono","year":"2014","journal-title":"PLoS One."},{"issue":"3","key":"10.3233\/THC-160487_ref8","doi-asserted-by":"crossref","first-page":"183","DOI":"10.1023\/A:1009995426001","article-title":"Subgrid-scale stress modelling based on the square of the velocity gradient tensor","volume":"62","author":"Nicoud","year":"1999","journal-title":"Flow, Turbulence and Combustion."},{"issue":"12","key":"10.3233\/THC-160487_ref9","doi-asserted-by":"crossref","first-page":"884","DOI":"10.4236\/jbise.2012.512A112","article-title":"The hemodynamic study for growth factor evaluation of rupture cerebral aneurysm followed up for five years\u00a0Journal","volume":"5","author":"Kojima","year":"2012","journal-title":"of Biomedical Science and Engineering."},{"issue":"5","key":"10.3233\/THC-160487_ref10","doi-asserted-by":"crossref","first-page":"831","DOI":"10.1007\/s11517-015-1374-8","article-title":"Hybrid stent device of flow-diverting effect and stent-assisted coil embolization formed by fractal structure","volume":"54","author":"Kojima","year":"2016","journal-title":"Medical & Biological Engineering & Computing."},{"issue":"3","key":"10.3233\/THC-160487_ref11","doi-asserted-by":"crossref","first-page":"255","DOI":"10.1161\/01.STR.3.3.255","article-title":"The hemodynamic importance of the geometry of bifurcations in the circle of Willis (glass model studies)","volume":"3","author":"Roach","year":"1972","journal-title":"Stroke."},{"key":"10.3233\/THC-160487_ref12","doi-asserted-by":"crossref","first-page":"E950","DOI":"10.1227\/01.NEU.0000255427.08926.DC","article-title":"Thrombosis of a fusiform intracranial aneurysm induced by overlapping Neuroform stents: case report","volume":"60","author":"Ansari","year":"2007","journal-title":"Neurosurgery."},{"key":"10.3233\/THC-160487_ref13","first-page":"1814","article-title":"Stent-within-a-stent technique for the treatment of dissecting vertebral artery aneurysms","volume":"24","author":"Mehta","year":"2003","journal-title":"AJNR Am J Neuroradiol."},{"key":"10.3233\/THC-160487_ref14","doi-asserted-by":"crossref","first-page":"1250","DOI":"10.1007\/s003300000697","article-title":"Intravascular stent placement for a fusiform aneurysm of the posterior cerebral artery: case report","author":"Brassel","year":"2001","journal-title":"Eur Radiol."},{"issue":"1","key":"10.3233\/THC-160487_ref15","doi-asserted-by":"crossref","first-page":"187","DOI":"10.1161\/01.STR.0000046456.26587.8B","article-title":"In vitro measurement of fluid-induced wall shear stress in unruptured cerebral aneurysms harboring blebs","volume":"34","author":"Tateshima","year":"2003","journal-title":"Stroke."},{"issue":"4","key":"10.3233\/THC-160487_ref16","first-page":"622","article-title":"Intra-aneurysmal hemodynamics during the growth of an unruptured aneurysm: in vitro study using longitudinal CT angiogram database","volume":"28","author":"Tateshima","year":"2007","journal-title":"Am J Neuroradiology."},{"issue":"11","key":"10.3233\/THC-160487_ref17","doi-asserted-by":"crossref","first-page":"2500","DOI":"10.1161\/01.STR.0000144648.89172.0f","article-title":"Magnitude and role of wall shear stress on cerebral aneurysm computational fluid dynamic study of 20 middle cerebral artery aneurysms","volume":"35","author":"Shojima","year":"2004","journal-title":"Stroke."},{"issue":"6","key":"10.3233\/THC-160487_ref18","doi-asserted-by":"crossref","first-page":"1924","DOI":"10.1161\/STROKEAHA.106.481234","article-title":"Complex hemodynamics at the apex of an arterial bifurcation induces vascular remodeling resembling cerebral aneurysm initiation","volume":"38","author":"Meng","year":"2007","journal-title":"Stroke."},{"issue":"21","key":"10.3233\/THC-160487_ref19","doi-asserted-by":"crossref","first-page":"2035","DOI":"10.1001\/jama.282.21.2035","article-title":"Hemodynamic shear stress and its role in atherosclerosis","volume":"282","author":"Malek","year":"1999","journal-title":"Jama."},{"key":"10.3233\/THC-160487_ref20","first-page":"1113","article-title":"Hemodynamics in a cerebral artery before and after the formation of an aneurysm","volume":"27","author":"Mantha","year":"2006","journal-title":"Am J Neuroradiology."},{"key":"10.3233\/THC-160487_ref21","doi-asserted-by":"crossref","first-page":"121","DOI":"10.1159\/000339678","article-title":"Local hemodynamics at the rupture point of cerebral aneurysms determined by computational fluid dynamic analysis","volume":"34","author":"Omodaka","year":"2012","journal-title":"Cerebrovascular Diseases."},{"issue":"3","key":"10.3233\/THC-160487_ref22","first-page":"293","article-title":"Pulsatile flow and atherosclerosis in the human carotid bifurcation","volume":"5","author":"Ku","year":"1985","journal-title":"Positive correlation between plaque location and low oscillating shear stress.\u00a0Arteriosclerosis, Thrombosis, and Vascular Biology."},{"key":"10.3233\/THC-160487_ref23","doi-asserted-by":"crossref","first-page":"455","DOI":"10.1177\/159101991301900408","article-title":"Y-Crossing of Braided Stents with Stents and Flow Diverters Does not Cause Significant Stenosis in Bench-Top Studies","volume":"19","author":"Makoyeva","year":"2013","journal-title":"Interventional Neuroradiology."},{"key":"10.3233\/THC-160487_ref24","first-page":"762389","article-title":"Y-Stenting for Bifurcation Aneurysm Coil Embolization: What is the Risk","author":"Alejandro","year":"2014","journal-title":"Stroke Research and Treatment."}],"container-title":["Technology and Health Care"],"original-title":[],"link":[{"URL":"https:\/\/content.iospress.com\/download?id=10.3233\/THC-160487","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,5,1]],"date-time":"2026-05-01T05:39:11Z","timestamp":1777613951000},"score":1,"resource":{"primary":{"URL":"https:\/\/journals.sagepub.com\/doi\/full\/10.3233\/THC-160487"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2017,10,23]]},"references-count":24,"journal-issue":{"issue":"5"},"URL":"https:\/\/doi.org\/10.3233\/thc-160487","relation":{},"ISSN":["0928-7329","1878-7401"],"issn-type":[{"value":"0928-7329","type":"print"},{"value":"1878-7401","type":"electronic"}],"subject":[],"published":{"date-parts":[[2017,10,23]]}}}