{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,6,26]],"date-time":"2026-06-26T06:43:08Z","timestamp":1782456188204,"version":"3.54.5"},"reference-count":26,"publisher":"SAGE Publications","issue":"4","content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["THC"],"published-print":{"date-parts":[[2018,9,27]]},"DOI":"10.3233\/thc-171157","type":"journal-article","created":{"date-parts":[[2018,4,24]],"date-time":"2018-04-24T15:00:04Z","timestamp":1524582004000},"page":"581-592","source":"Crossref","is-referenced-by-count":15,"title":["The comparison of transfemoral amputees using mechanical and microprocessor- controlled prosthetic knee under different walking speeds: A randomized cross-over trial"],"prefix":"10.1177","volume":"26","author":[{"given":"Wujing","family":"Cao","sequence":"first","affiliation":[{"name":"Rehabilitation Engineering and Technology Institute, University of Shanghai for Science and Technology, Shanghai, China"},{"name":"Shanghai Engineering Research Center of Assistive Devices, Shanghai, China"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Hongliu","family":"Yu","sequence":"additional","affiliation":[{"name":"Rehabilitation Engineering and Technology Institute, University of Shanghai for Science and Technology, Shanghai, China"},{"name":"Shanghai Engineering Research Center of Assistive Devices, Shanghai, China"},{"name":"Key Laboratory of Neural-functional Information and Rehabilitation Engineering of the Ministry of Civil Affairs, Shanghai, China"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Weiliang","family":"Zhao","sequence":"additional","affiliation":[{"name":"Rehabilitation Engineering and Technology Institute, University of Shanghai for Science and Technology, Shanghai, China"},{"name":"Shanghai Engineering Research Center of Assistive Devices, Shanghai, China"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Qiaoling","family":"Meng","sequence":"additional","affiliation":[{"name":"Rehabilitation Engineering and Technology Institute, University of Shanghai for Science and Technology, Shanghai, China"},{"name":"Shanghai Engineering Research Center of Assistive Devices, Shanghai, China"},{"name":"Key Laboratory of Neural-functional Information and Rehabilitation Engineering of the Ministry of Civil Affairs, Shanghai, China"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Wenming","family":"Chen","sequence":"additional","affiliation":[{"name":"Rehabilitation Engineering and Technology Institute, University of Shanghai for Science and Technology, Shanghai, China"},{"name":"Shanghai Engineering Research Center of Assistive Devices, Shanghai, China"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"179","reference":[{"key":"10.3233\/THC-171157_ref1","doi-asserted-by":"crossref","unstructured":"Geeroms J, Flynn L, Jimenez Fabian R E, et al. Design and energetic evaluation of a prosthetic knee joint actuator with a lockable parallel spring[J]. Bioinspiration & Biomimetics, 2017, 12(2).","DOI":"10.1088\/1748-3190\/aa575c"},{"issue":"1","key":"10.3233\/THC-171157_ref3","doi-asserted-by":"crossref","first-page":"65","DOI":"10.1515\/bmt-2013-0069","article-title":"Designs and performance of microprocessor-controlled knee joints[J]","volume":"59","author":"Thiele","year":"2014","journal-title":"Biomedizinische Technik Biomedical Engineering"},{"issue":"2","key":"10.3233\/THC-171157_ref4","doi-asserted-by":"crossref","first-page":"145","DOI":"10.5405\/jmbe.821","article-title":"Development of a low-technology prosthetic swing-phase mechanism[J]","volume":"31","author":"Furse","year":"2011","journal-title":"Journal of Medical & Biological Engineering"},{"issue":"1","key":"10.3233\/THC-171157_ref5","first-page":"1","article-title":"Target of physiological gait: Realization of speed adaptive control for a prosthetic knee during swing flexion[J]","volume":"2017","author":"Cao","journal-title":"Technology & Health Care Official Journal of the European Society for Engineering & Medicine"},{"issue":"6","key":"10.3233\/THC-171157_ref6","first-page":"435","article-title":"Stair ascent with an innovative microprocessor-controlled exoprosthetic knee joint[J]","volume":"57","author":"Bellmann","year":"2012","journal-title":"Biomedical Engineering-biomedizinische Technik"},{"issue":"4","key":"10.3233\/THC-171157_ref7","doi-asserted-by":"crossref","first-page":"362","DOI":"10.3109\/03093646.2010.520054","article-title":"Safety, energy efficiency, and cost efficacy of the C-Leg for transfemoral amputees: A review of the literature[J]","volume":"34","author":"Highsmith","year":"2010","journal-title":"Prosthetics & Orthotics International"},{"issue":"2","key":"10.3233\/THC-171157_ref8","first-page":"226","article-title":"Adjusting and Logging Rheo Knee Parameter Values Using a Smartphone Application[J]","volume":"123","author":"Edwards","year":"2015","journal-title":"Journal of Magnetic Resonance"},{"issue":"1","key":"10.3233\/THC-171157_ref9","doi-asserted-by":"crossref","first-page":"73","DOI":"10.1080\/03093640500533414","article-title":"Comparison of different microprocessor controlled knee joints on the energy consumption during walking in trans-femoral amputees: Intelligent Knee Prosthesis (IP) versus C-Leg[J]","volume":"30","author":"Chin","year":"2006","journal-title":"Prosthetics & Orthotics International"},{"key":"10.3233\/THC-171157_ref10","doi-asserted-by":"crossref","unstructured":"Pasquina, Paul F, Carvalho, et al. Case Series of Wounded Warriors Receiving Initial Fit PowerKneeTM Prosthesis[J]. Jpo Journal of Prosthetics & Orthotics, 2017, 29(2): 1.","DOI":"10.1097\/JPO.0000000000000123"},{"issue":"2","key":"10.3233\/THC-171157_ref11","doi-asserted-by":"crossref","first-page":"239","DOI":"10.1682\/JRRD.2005.06.0095","article-title":"Gait efficiency using the C-Leg[J].","volume":"43","author":"Orendurff","year":"2006","journal-title":"Journal of Rehabilitation Research & Development"},{"issue":"1","key":"10.3233\/THC-171157_ref12","doi-asserted-by":"crossref","first-page":"51","DOI":"10.1080\/03093640600982255","article-title":"Comparison between the C-leg microprocessor-controlled prosthetic knee and non-microprocessor control prosthetic knees: a preliminary study of energy expenditure, obstacle course performance, and quality of life survey[J]","volume":"31","author":"Seymour","year":"2007","journal-title":"Prosthetics & Orthotics International"},{"issue":"4","key":"10.3233\/THC-171157_ref13","doi-asserted-by":"crossref","first-page":"489","DOI":"10.1016\/j.gaitpost.2007.07.011","article-title":"Gait and balance of transfemoral amputees using passive mechanical and microprocessor-controlled prosthetic knees[J]","volume":"26","author":"Kaufman","year":"2007","journal-title":"Gait & Posture"},{"issue":"10","key":"10.3233\/THC-171157_ref14","doi-asserted-by":"crossref","first-page":"713","DOI":"10.1016\/0021-9290(81)90054-3","article-title":"Kinematic prediction of intersegment loads and power at the joints of the leg in walking[J]","volume":"14","author":"Zarrugh","year":"1981","journal-title":"Journal of Biomechanics"},{"issue":"1","key":"10.3233\/THC-171157_ref15","first-page":"1","article-title":"Target of physiological gait: Realization of speed adaptive control for a prosthetic knee during swing flexion[J]","volume":"2017","author":"Cao","journal-title":"Technology & Health Care Official Journal of the European Society for Engineering & Medicine"},{"key":"10.3233\/THC-171157_ref16","doi-asserted-by":"crossref","unstructured":"Wei C, Nothnagle C, Savant P, et al. Pneumatic actuator inserts for interface pressure mapping and fit improvement in lower extremity prosthetics[C]\/\/ IEEE International Conference on Biomedical Robotics and Biomechatronics. IEEE, 2016: pp. 574-579.","DOI":"10.1109\/BIOROB.2016.7523687"},{"issue":"5","key":"10.3233\/THC-171157_ref17","doi-asserted-by":"crossref","first-page":"460","DOI":"10.1016\/j.clinbiomech.2011.11.011","article-title":"Gait asymmetry of transfemoral amputees using mechanical and microprocessor-controlled prosthetic knees[J]","volume":"27","author":"Kaufman","year":"2012","journal-title":"Clinical Biomechanics"},{"issue":"1","key":"10.3233\/THC-171157_ref19","doi-asserted-by":"crossref","first-page":"71","DOI":"10.1109\/TNSRE.2010.2087360","article-title":"Upslope Walking With a Powered Knee and Ankle Prosthesis: Initial Results With an Amputee Subject[J]","volume":"19","author":"Sup","year":"2011","journal-title":"IEEE Transactions on Neural Systems & Rehabilitation Engineering A Publication of the IEEE Engineering in Medicine & Biology Society"},{"key":"10.3233\/THC-171157_ref20","doi-asserted-by":"crossref","unstructured":"Lambrecht B G A, Kazerooni H. Design of a semi-active knee prosthesis[C]\/\/ IEEE International Conference on Robotics and Automation. IEEE, 2009: pp. 639-645.","DOI":"10.1109\/ROBOT.2009.5152828"},{"key":"10.3233\/THC-171157_ref21","doi-asserted-by":"crossref","unstructured":"Awad M, Tee K S, Dehghani A, et al. DESIGN OF AN EFFICIENT BACK-DRIVABLE SEMI-ACTIVE ABOVE KNEE PROSTHESIS[C]\/\/ Field Robotics-, International Conference on Climbing and Walking Robots and the Support Technologies for Mobile Machines. 2015: pp. 35-42.","DOI":"10.1142\/9789814374286_0004"},{"issue":"7","key":"10.3233\/THC-171157_ref22","doi-asserted-by":"crossref","first-page":"857","DOI":"10.1682\/JRRD.2005.09.0147","article-title":"Kinematic and kinetic comparisons of transfemoral amputee gait using C-Leg and Mauch SNS prosthetic knees[J]","volume":"43","author":"Segal","year":"2006","journal-title":"Journal of Rehabilitation Research & Development"},{"issue":"1","key":"10.3233\/THC-171157_ref23","doi-asserted-by":"crossref","first-page":"1","DOI":"10.1682\/JRRD.2007.04.0054","article-title":"Comparison of nonmicroprocessor knee mechanism versus C-Leg on Prosthesis Evaluation Questionnaire, stumbles, falls, walking tests, stair descent, and knee preference[J]","volume":"45","author":"Kahle","year":"2008","journal-title":"Journal of Rehabilitation Research & Development"},{"issue":"6","key":"10.3233\/THC-171157_ref24","doi-asserted-by":"crossref","first-page":"447","DOI":"10.1177\/0309364613506912","article-title":"Impact of a stance phase microprocessor-controlled knee prosthesis on level walking in lower functioning individuals with a transfemoral amputation[J]","volume":"38","author":"Eberly","year":"2014","journal-title":"Prosthetics & Orthotics International"},{"issue":"8","key":"10.3233\/THC-171157_ref25","doi-asserted-by":"crossref","first-page":"563","DOI":"10.1097\/01.phm.0000174665.74933.0b","article-title":"A clinical comparison of variable-damping and mechanically passive prosthetic knee devices[J]","volume":"84","author":"Johansson","year":"2005","journal-title":"American Journal of Physical Medicine & Rehabilitation"},{"issue":"4","key":"10.3233\/THC-171157_ref26","doi-asserted-by":"crossref","first-page":"398","DOI":"10.1191\/0269215505cr805oa","article-title":"A comparative evaluation of oxygen consumption and gait pattern in amputees using Intelligent Prostheses and conventionally damped knee swing-phase control[J]","volume":"19","author":"Datta","year":"2005","journal-title":"Clinical Rehabilitation"},{"key":"10.3233\/THC-171157_ref27","doi-asserted-by":"crossref","first-page":"254","DOI":"10.1016\/j.gaitpost.2016.11.015","article-title":"The influence of a user-adaptive prosthetic knee across varying walking speeds: A randomized cross-over trial[J]","volume":"51","author":"Prinsen","year":"2017","journal-title":"Gait & Posture"},{"issue":"1","key":"10.3233\/THC-171157_ref28","doi-asserted-by":"crossref","first-page":"42","DOI":"10.1108\/01439910310457706","article-title":"User-adaptive control of a magnetorheological prosthetic knee[J]","volume":"30","author":"Herr","year":"2003","journal-title":"Industrial Robot"}],"container-title":["Technology and Health Care"],"original-title":[],"link":[{"URL":"https:\/\/content.iospress.com\/download?id=10.3233\/THC-171157","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,5,1]],"date-time":"2026-05-01T05:41:36Z","timestamp":1777614096000},"score":1,"resource":{"primary":{"URL":"https:\/\/journals.sagepub.com\/doi\/full\/10.3233\/THC-171157"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2018,9,27]]},"references-count":26,"journal-issue":{"issue":"4"},"URL":"https:\/\/doi.org\/10.3233\/thc-171157","relation":{},"ISSN":["0928-7329","1878-7401"],"issn-type":[{"value":"0928-7329","type":"print"},{"value":"1878-7401","type":"electronic"}],"subject":[],"published":{"date-parts":[[2018,9,27]]}}}