{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,7,8]],"date-time":"2026-07-08T05:38:38Z","timestamp":1783489118641,"version":"3.55.0"},"reference-count":49,"publisher":"SAGE Publications","issue":"3","content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["THC"],"published-print":{"date-parts":[[2021,5,17]]},"abstract":"<jats:p>BACKGROUND: The distal biceps brachii tendon rupture is a rare injury of the musculoskeletal system. Multiple surgical techniques have been described for distal biceps brachii tendon repairs including suture anchors. OBJECTIVE: The aim of this study was to evaluate the outcome of anatomical distal biceps tendon refixation using either one or two suture anchors for reattachment and to determine whether there are significant clinically important differences on the number of anchors used for refixation. METHODS: A monocentric, randomized controlled trial was conducted, including 16 male patients with a mean age of 47.4\u00a0years (range, 31.0 to 58.0) in Group 1 (two suture anchors for refixation) and 15 male patients with a mean age of 47.4 (range, 35.0 to 59.0) in Group 2 (one suture anchor for refixation). All surgeries were performed through an anterior approach. The outcome was assessed using the Oxford Elbow Score (OES), the Mayo Elbow Performance Score (MEPS), the Disabilities of the Arm, Shoulder and Hand (DASH) score, the Andrews Carson Score (ACS) and by isokinetic strength measurement for the elbow flexion after six, twelve, 24 and 48 weeks. Radiographic controls were performed after 24 and 48 weeks. RESULTS: No significant differences between both groups were evident at any point during the follow-up period. A continuous improvement in outcome for both groups could be detected, reaching an OES: 46.3 (39.0 to 48.0) vs. 45.5 (30.0 to 48.0), MEPS: 98.0 (85.0 to 100.0) vs. 99.0 (85.0 to 100.0), DASH: 3.1 (0.0 to 16.7) vs. 2.9 (0.0 to 26.7), ACS: 197.0 (175.0 to 200.0) vs. 197.7<\/jats:p>","DOI":"10.3233\/thc-202476","type":"journal-article","created":{"date-parts":[[2021,1,19]],"date-time":"2021-01-19T13:20:41Z","timestamp":1611062441000},"page":"575-588","source":"Crossref","is-referenced-by-count":3,"title":["No functional differences in anatomic reconstruction using a one- versus a two-point fixation for distal biceps tendon rupture through a single-incision anterior approach: A prospective randomized trial"],"prefix":"10.1177","volume":"29","author":[{"given":"Manuel","family":"Wei\u00dfenberger","sequence":"first","affiliation":[{"name":"Berufsgenossenschaftliche Unfallklinik Frankfurt am Main, Department of Trauma and Orthopaedic Surgery, Frankfurt am Main, Germany"},{"name":"Department of Orthopaedic Surgery, Koenig-Ludwig-Haus, Julius-Maximilians-University, Wuerzburg, Germany"},{"name":"Berufsgenossenschaftliche Unfallklinik Frankfurt am Main, Department of Trauma and Orthopaedic Surgery, Frankfurt am Main, Germany"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Alexander","family":"Klug","sequence":"additional","affiliation":[{"name":"Berufsgenossenschaftliche Unfallklinik Frankfurt am Main, Department of Trauma and Orthopaedic Surgery, Frankfurt am Main, Germany"},{"name":"Berufsgenossenschaftliche Unfallklinik Frankfurt am Main, Department of Trauma and Orthopaedic Surgery, Frankfurt am Main, Germany"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Tizian","family":"Heinz","sequence":"additional","affiliation":[{"name":"Department of Orthopaedic Surgery, Koenig-Ludwig-Haus, Julius-Maximilians-University, Wuerzburg, Germany"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Kilian","family":"Rueckl","sequence":"additional","affiliation":[{"name":"Department of Orthopaedic Surgery, Koenig-Ludwig-Haus, Julius-Maximilians-University, Wuerzburg, Germany"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Hans","family":"Kollenda","sequence":"additional","affiliation":[{"name":"Berufsgenossenschaftliche Unfallklinik Frankfurt am Main, Department of Trauma and Orthopaedic Surgery, Frankfurt am Main, Germany"},{"name":"Supervisory Center North for Public Law Tasks of the Bundeswehr Medical Service, Kronshagen, Germany"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Maximilian","family":"Rudert","sequence":"additional","affiliation":[{"name":"Department of Orthopaedic Surgery, Koenig-Ludwig-Haus, Julius-Maximilians-University, Wuerzburg, Germany"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Reinhard","family":"Hoffmann","sequence":"additional","affiliation":[{"name":"Berufsgenossenschaftliche Unfallklinik Frankfurt am Main, Department of Trauma and Orthopaedic Surgery, Frankfurt am Main, Germany"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Kay","family":"Schmidt-Horloh\u00e9","sequence":"additional","affiliation":[{"name":"Berufsgenossenschaftliche Unfallklinik Frankfurt am Main, Department of Trauma and Orthopaedic Surgery, Frankfurt am Main, Germany"},{"name":"Orthopaedicum Wiesbaden, Wiesbaden, Germany"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"179","reference":[{"issue":"8","key":"10.3233\/THC-202476_ref1","doi-asserted-by":"crossref","first-page":"2012","DOI":"10.1177\/0363546515587738","article-title":"Distal biceps tendon ruptures: an epidemiological analysis using a large population database","volume":"43","author":"Kelly","year":"2015","journal-title":"Am J Sports Medicine."},{"key":"10.3233\/THC-202476_ref2","doi-asserted-by":"crossref","first-page":"275","DOI":"10.1097\/00003086-200211000-00042","article-title":"Distal biceps tendon ruptures","volume":"404","author":"Safran","year":"2002","journal-title":"Clin Orthop Relat R."},{"issue":"3","key":"10.3233\/THC-202476_ref3","doi-asserted-by":"crossref","first-page":"418","DOI":"10.2106\/00004623-198567030-00011","article-title":"Rupture of the distal tendon of the biceps brachii. A biomechanical study","volume":"67","author":"Morrey","year":"1985","journal-title":"J Bone Jt Surg."},{"issue":"4","key":"10.3233\/THC-202476_ref4","first-page":"417","article-title":"Distal biceps tendon rupture: current concepts","volume":"44","author":"Sarda","year":"2012","journal-title":"Inj."},{"issue":"3","key":"10.3233\/THC-202476_ref5","doi-asserted-by":"crossref","first-page":"414","DOI":"10.2106\/00004623-198567030-00010","article-title":"Rupture of the distal tendon of the biceps brachii. Operative versus non-operative treatment","volume":"67","author":"Baker","year":"1985","journal-title":"J Bone Jt Surg."},{"issue":"13","key":"10.3233\/THC-202476_ref6","doi-asserted-by":"crossref","first-page":"3020","DOI":"10.1177\/0363546517720200","article-title":"Surgical treatment of distal biceps tendon ruptures: an analysis of complications in 784 surgical repairs","volume":"45","author":"Dunphy","year":"2017","journal-title":"Am J Sports Medicine."},{"issue":"8","key":"10.3233\/THC-202476_ref7","doi-asserted-by":"crossref","first-page":"698","DOI":"10.3928\/01477447-20120725-08","article-title":"Single versus double-incision technique for the repair of acute distal biceps tendon ruptures: a randomized clinical trial","volume":"35","author":"Grewal","year":"2012","journal-title":"Orthopedics."},{"issue":"7","key":"10.3233\/THC-202476_ref8","first-page":"753","article-title":"Avulsion of the distal biceps brachii tendon in middle-aged population: is surgical repair advisable","volume":"39","author":"Hetsroni","year":"2008","journal-title":"Inj."},{"issue":"2","key":"10.3233\/THC-202476_ref9","doi-asserted-by":"crossref","first-page":"e29","DOI":"10.1016\/j.jse.2015.09.004","article-title":"Refixation techniques and approaches for distal biceps tendon ruptures: a systematic review of clinical studies","volume":"25","author":"Kodde","year":"2015","journal-title":"J Shoulder Elb Surg Am Shoulder Elb Surg Et Al."},{"issue":"11","key":"10.3233\/THC-202476_ref10","doi-asserted-by":"crossref","first-page":"1541","DOI":"10.1007\/s00402-018-3018-6","article-title":"Functional outcome in patients who underwent distal biceps tendon repair","volume":"138","author":"Janssen","year":"2018","journal-title":"Arch Orthop Traum Su."},{"issue":"8","key":"10.3233\/THC-202476_ref11","doi-asserted-by":"crossref","first-page":"1618","DOI":"10.1177\/0363546508321482","article-title":"Repair of the ruptured distal biceps tendon","volume":"36","author":"Chavan","year":"2008","journal-title":"Am J Sports Medicine."},{"issue":"11","key":"10.3233\/THC-202476_ref12","doi-asserted-by":"crossref","first-page":"2128","DOI":"10.2106\/JBJS.I.01213","article-title":"Distal biceps tendon injuries","volume":"92","author":"Miyamoto","year":"2010","journal-title":"J Bone Jt Surgery-american Volume."},{"issue":"3","key":"10.3233\/THC-202476_ref13","doi-asserted-by":"crossref","first-page":"926","DOI":"10.1007\/s00167-013-2590-0","article-title":"Double intramedullary cortical button versus suture anchors for distal biceps tendon repair: a biomechanical comparison","volume":"23","author":"Siebenlist","year":"2015","journal-title":"Knee Surg Sports Traumatology Arthrosc."},{"issue":"24","key":"10.3233\/THC-202476_ref14","doi-asserted-by":"crossref","first-page":"2086","DOI":"10.2106\/JBJS.M.00481","article-title":"Repair techniques for acute distal biceps tendon ruptures: a systematic review","volume":"96","author":"Watson","year":"2014","journal-title":"J Bone Jt Surg Am Volume."},{"issue":"7","key":"10.3233\/THC-202476_ref15","doi-asserted-by":"crossref","first-page":"1041","DOI":"10.2106\/00004623-196143070-00012","article-title":"A method for reinsertion of the distal biceps brachii tendon","volume":"43","author":"Boyd","year":"1961","journal-title":"J Bone Jt Surg."},{"key":"10.3233\/THC-202476_ref16","doi-asserted-by":"crossref","first-page":"S113","DOI":"10.1016\/j.jse.2010.11.009","article-title":"Controversies in the surgical treatment of distal biceps tendon ruptures: single versus double-incision repairs","volume":"20","author":"Keener","year":"2011","journal-title":"J Shoulder Elb Surg Am Shoulder Elb Surg Et Al."},{"issue":"253","key":"10.3233\/THC-202476_ref17","first-page":"133","article-title":"Proximal radioulnar synostosis after repair of distal biceps brachii rupture by the two-incision technique: report of four cases","author":"Failla","year":"1990","journal-title":"Clin Orthop Relat R."},{"issue":"10","key":"10.3233\/THC-202476_ref18","doi-asserted-by":"crossref","first-page":"1898","DOI":"10.1016\/j.jse.2018.06.028","article-title":"Major complications after distal biceps tendon repairs: retrospective cohort analysis of 970 cases","volume":"27","author":"Ford","year":"2018","journal-title":"J Shoulder Elb Surg."},{"issue":"11","key":"10.3233\/THC-202476_ref19","doi-asserted-by":"crossref","first-page":"1575","DOI":"10.2106\/00004623-200011000-00010","article-title":"Complications of repair of the distal biceps tendon with the modified two-incision technique*\u2020","volume":"82","author":"Kelly","year":"2000","journal-title":"J Bone Jt Surgery-american Volume."},{"issue":"1","key":"10.3233\/THC-202476_ref20","doi-asserted-by":"crossref","first-page":"364","DOI":"10.1186\/s12891-018-2278-1","article-title":"Distal biceps tendon rupture: advantages and drawbacks of the anatomical reinsertion with a modified double incision approach","volume":"19","author":"Tarallo","year":"2018","journal-title":"Bmc Musculoskelet Di."},{"issue":"2","key":"10.3233\/THC-202476_ref21","doi-asserted-by":"crossref","first-page":"120","DOI":"10.1067\/2000.102581","article-title":"Repair of distal biceps tendon rupture: a new technique using the endobutton","volume":"9","author":"Bain","year":"2000","journal-title":"J Shoulder Elb Surg."},{"issue":"5","key":"10.3233\/THC-202476_ref22","doi-asserted-by":"crossref","first-page":"989","DOI":"10.1177\/0363546508330130","article-title":"A combined technique for distal biceps repair using a soft tissue button and biotenodesis interference screw","volume":"37","author":"Heinzelmann","year":"2009","journal-title":"Am J Sports Medicine."},{"issue":"1","key":"10.3233\/THC-202476_ref23","doi-asserted-by":"crossref","first-page":"78","DOI":"10.1016\/j.jse.2006.03.002","article-title":"Single-incision repair of acute distal biceps ruptures by use of suture anchors","volume":"16","author":"John","year":"2007","journal-title":"J Shoulder Elb Surg."},{"issue":"5","key":"10.3233\/THC-202476_ref24","doi-asserted-by":"crossref","first-page":"418.e1","DOI":"10.1016\/j.jhsa.2018.07.005","article-title":"Intramedullary cortical button repair for distal biceps tendon rupture: a single-center experience","volume":"44","author":"Siebenlist","year":"2018","journal-title":"J Hand Surg."},{"issue":"1","key":"10.3233\/THC-202476_ref25","doi-asserted-by":"crossref","first-page":"39","DOI":"10.1016\/j.arthro.2007.06.019","article-title":"Repair of distal biceps tendon ruptures using suture anchors through a single anterior incision","volume":"24","author":"Khan","year":"2007","journal-title":"Arthrosc J Arthrosc Relat Surg Official Publ Arthrosc Assoc North Am Int Art."},{"issue":"1","key":"10.3233\/THC-202476_ref26","doi-asserted-by":"crossref","first-page":"19","DOI":"10.1007\/s12306-015-0372-1","article-title":"Mini-open incision for distal biceps repair by suture anchors: follow-up of eighteen patients","volume":"100","author":"Pangallo","year":"2015","journal-title":"Musculoskelet Surg."},{"issue":"7","key":"10.3233\/THC-202476_ref27","doi-asserted-by":"crossref","first-page":"939","DOI":"10.1007\/s00402-017-2724-9","article-title":"Good isometric and isokinetic power restoration after distal biceps tendon repair with anchors","volume":"137","author":"Suda","year":"2017","journal-title":"Arch Orthop Traum Su."},{"issue":"8","key":"10.3233\/THC-202476_ref28","doi-asserted-by":"crossref","first-page":"1225","DOI":"10.1016\/j.jhsa.2007.05.027","article-title":"The distal biceps tendon: footprint and relevant clinical anatomy","volume":"32","author":"Athwal","year":"2007","journal-title":"J Hand Surg."},{"issue":"5","key":"10.3233\/THC-202476_ref29","first-page":"1044","article-title":"Distal biceps tendon anatomy: a cadaveric study","volume":"89","author":"Eames","year":"2007","journal-title":"JBJS."},{"issue":"3","key":"10.3233\/THC-202476_ref30","doi-asserted-by":"crossref","first-page":"252","DOI":"10.1016\/j.otsr.2010.11.010","article-title":"Suture anchor reinsertion of distal biceps rupture: clinical results and radiological assessment of tendon healing","volume":"97","author":"Gallinet","year":"2011","journal-title":"Orthop Traumatology Surg Res Otsr."},{"issue":"2","key":"10.3233\/THC-202476_ref31","doi-asserted-by":"crossref","first-page":"252","DOI":"10.1177\/0363546506294854","article-title":"Biomechanical evaluation of 4 techniques of distal biceps brachii tendon repair","volume":"35","author":"Mazzocca","year":"2007","journal-title":"Am J Sports Medicine."},{"issue":"8","key":"10.3233\/THC-202476_ref32","doi-asserted-by":"crossref","first-page":"1762","DOI":"10.1177\/0363546511404139","article-title":"Biomechanical in vitro validation of intramedullary cortical button fixation for distal biceps tendon repair: a new technique","volume":"39","author":"Siebenlist","year":"2011","journal-title":"Am J Sports Medicine."},{"issue":"9","key":"10.3233\/THC-202476_ref33","doi-asserted-by":"crossref","first-page":"e0182557","DOI":"10.1371\/journal.pone.0182557","article-title":"Minimal important change and other measurement properties of the Oxford Elbow Score and the Quick Disabilities of the Arm, Shoulder, and Hand in patients with a simple elbow dislocation; validation study alongside the multicenter FuncSiE trial","volume":"12","author":"Iordens","year":"2017","journal-title":"Plos One."},{"issue":"4","key":"10.3233\/THC-202476_ref34","doi-asserted-by":"crossref","first-page":"873","DOI":"10.1007\/s00264-013-2200-2","article-title":"The functional outcome of forty-nine single-incision suture anchor repairs for distal biceps tendon ruptures at the elbow","volume":"38","author":"Siebenlist","year":"2013","journal-title":"Int Orthop."},{"issue":"3","key":"10.3233\/THC-202476_ref35","doi-asserted-by":"crossref","first-page":"302","DOI":"10.1016\/j.jse.2004.09.007","article-title":"Patient-oriented functional outcome after repair of distal biceps tendon ruptures using a single-incision technique","volume":"14","author":"McKee","year":"2005","journal-title":"J Shoulder Elb Surg."},{"issue":"8","key":"10.3233\/THC-202476_ref36","doi-asserted-by":"crossref","first-page":"1157","DOI":"10.1016\/j.jse.2010.05.027","article-title":"The effect of biceps reattachment site","volume":"19","author":"Schmidt","year":"2010","journal-title":"J Shoulder Elb Surg."},{"issue":"12","key":"10.3233\/THC-202476_ref37","doi-asserted-by":"crossref","first-page":"1623","DOI":"10.1016\/j.jse.2012.03.009","article-title":"Repaired distal biceps magnetic resonance imaging anatomy compared with outcome","volume":"21","author":"Schmidt","year":"2012","journal-title":"J Shoulder Elb Surg."},{"issue":"3","key":"10.3233\/THC-202476_ref38","doi-asserted-by":"crossref","first-page":"e0013","DOI":"10.2106\/JBJS.OA.19.00013","article-title":"Outcomes and complications after repair of complete distal biceps tendon rupture with the cortical button technique","volume":"4","author":"Huynh","year":"2019","journal-title":"Jbjs Open Access."},{"issue":"1","key":"10.3233\/THC-202476_ref39","doi-asserted-by":"crossref","first-page":"S67","DOI":"10.1016\/j.jse.2007.04.008","article-title":"Complications associated with repair of a distal biceps rupture using the modified two-incision technique","volume":"17","author":"Bisson","year":"2008","journal-title":"J Shoulder Elb Surg."},{"issue":"9","key":"10.3233\/THC-202476_ref40","doi-asserted-by":"crossref","first-page":"1544","DOI":"10.1177\/0363546507300690","article-title":"Failure strengths in distal biceps tendon repair","volume":"35","author":"Kettler","year":"2007","journal-title":"Am J Sports Medicine."},{"issue":"10","key":"10.3233\/THC-202476_ref41","doi-asserted-by":"crossref","first-page":"2478","DOI":"10.1177\/0363546519860489","article-title":"Biomechanical comparison of onlay distal biceps tendon repair: all-suture anchors versus titanium suture anchors","volume":"47","author":"Otto","year":"2019","journal-title":"Am J Sports Medicine."},{"issue":"11","key":"10.3233\/THC-202476_ref42","doi-asserted-by":"crossref","first-page":"2214","DOI":"10.1177\/0363546509337451","article-title":"Distal biceps tendon repair: a cadaveric analysis of suture anchor and interference screw restoration of the anatomic footprint","volume":"37","author":"Jobin","year":"2009","journal-title":"Am J Sports Medicine."},{"issue":"11","key":"10.3233\/THC-202476_ref43","doi-asserted-by":"crossref","first-page":"1936","DOI":"10.1007\/s00167-011-1591-0","article-title":"Surgical repair of the distal biceps brachii tendon: a comparative study of three surgical fixation techniques","volume":"19","author":"Citak","year":"2011","journal-title":"Knee Surg Sports Traumatology Arthrosc."},{"issue":"6","key":"10.3233\/THC-202476_ref44","doi-asserted-by":"crossref","first-page":"859","DOI":"10.1016\/j.otsr.2018.05.013","article-title":"Treatment of primary total distal biceps tendon rupture using cortical button, transosseus fixation and suture anchor: a single center experience","volume":"104","author":"Lang","year":"2018","journal-title":"Orthop Traumatology Surg Res."},{"issue":"11","key":"10.3233\/THC-202476_ref45","doi-asserted-by":"crossref","first-page":"1607","DOI":"10.1016\/j.jse.2014.06.049","article-title":"A comparison of cortical button with interference screw versus suture anchor techniques for distal biceps brachii tendon repairs","volume":"23","author":"Olsen","year":"2014","journal-title":"J Shoulder Elb Surg Am Shoulder Elb Surg Et Al."},{"issue":"1","key":"10.3233\/THC-202476_ref46","doi-asserted-by":"crossref","first-page":"103","DOI":"10.1016\/j.jos.2018.08.007","article-title":"A comparative clinical and functional assessment of cortical button versus suture anchor in distal biceps brachii tendon repair","volume":"24","author":"Reichert","year":"2019","journal-title":"Journal of Orthopaedic Science."},{"issue":"5","key":"10.3233\/THC-202476_ref47","doi-asserted-by":"crossref","first-page":"1072","DOI":"10.1177\/0363546515570465","article-title":"Distal biceps brachii tendon repairs: a single-incision technique using a cortical button with interference screw versus a double-incision technique using suture fixation through bone tunnels","volume":"43","author":"Shields","year":"2015","journal-title":"Am J Sports Medicine."},{"issue":"11","key":"10.3233\/THC-202476_ref48","doi-asserted-by":"crossref","first-page":"1925","DOI":"10.1007\/s00167-011-1569-y","article-title":"The double intramedullary cortical button fixation for distal biceps tendon repair","volume":"19","author":"Siebenlist","year":"2011","journal-title":"Knee Surg Sports Traumatology Arthrosc."},{"issue":"2","key":"10.3233\/THC-202476_ref49","first-page":"181","article-title":"Biology of tendon injury: healing, modeling and remodeling","volume":"6","author":"Sharma","year":"2006","journal-title":"J Musculoskelet Neuronal Interact."}],"container-title":["Technology and Health Care"],"original-title":[],"link":[{"URL":"https:\/\/content.iospress.com\/download?id=10.3233\/THC-202476","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,5,1]],"date-time":"2026-05-01T05:52:21Z","timestamp":1777614741000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.medra.org\/servlet\/aliasResolver?alias=iospress&doi=10.3233\/THC-202476"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2021,5,17]]},"references-count":49,"journal-issue":{"issue":"3"},"URL":"https:\/\/doi.org\/10.3233\/thc-202476","relation":{},"ISSN":["0928-7329","1878-7401"],"issn-type":[{"value":"0928-7329","type":"print"},{"value":"1878-7401","type":"electronic"}],"subject":[],"published":{"date-parts":[[2021,5,17]]}}}