{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,5,4]],"date-time":"2026-05-04T10:38:56Z","timestamp":1777891136435,"version":"3.51.4"},"reference-count":26,"publisher":"SAGE Publications","issue":"4","content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["THC"],"published-print":{"date-parts":[[2023,6,30]]},"abstract":"<jats:p>BACKGROUND: The BHOHB system (Bhohb S.r.l., Italy) is a portable non-invasive photographic marker-based device for postural examination. OBJECTIVE: To assess the test-retest reliability of the BHOHB system and compare its reliability with an optoelectronic system (SMART-DX 700, BTS, Italy). METHODS: Thirty volunteers were instructed to stand upright with five markers on the spinous processes of C7, T6, T12, L3 and S1 vertebrae to define the dorsal kyphosis and lumbar lordosis (sagittal plane) angles. Three markers were placed on the great trochanter, apex of iliac crest and lateral condyle of the femur to detect pelvic tilt. Finally, to define angles between the acromion and the spinous processes (frontal plane), two markers were placed on the right and left acromion. Postural angles were recoded simultaneously with BHOHB and optoelectronic systems during two consecutive recording sessions. RESULTS: The BHOHB system revealed excellent reliability for all the angles (ICCs: 0.92\u20130.99, SEM: 0.78\u2218\u20133.33\u2218) as well as a shorter processing time compared to the optoelectronic system. Excellent reliability was also found for all the angles detected through the optoelectronic system (ICCs: 0.91\u20130.99, SEM: 0.84\u2218\u20132.80\u2218). CONCLUSION: The BHOHB system resulted as a reliable non-invasive and user-friendly device to monitor spinal posture, especially in subjects requiring repeat examinations.<\/jats:p>","DOI":"10.3233\/thc-220155","type":"journal-article","created":{"date-parts":[[2023,3,24]],"date-time":"2023-03-24T12:37:52Z","timestamp":1679661472000},"page":"1153-1160","source":"Crossref","is-referenced-by-count":2,"title":["Test-retest reliability of a photographic marker-based system for postural examination"],"prefix":"10.1177","volume":"31","author":[{"given":"Federico","family":"Temporiti","sequence":"first","affiliation":[{"name":"Physiotherapy Unit, Humanitas Clinical and Research Center \u2013 IRCCS, Milan, Italy"},{"name":"Department of Biomedical Sciences, Humanitas University, Milan, Italy"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Paola","family":"Adamo","sequence":"additional","affiliation":[{"name":"Physiotherapy Unit, Humanitas Clinical and Research Center \u2013 IRCCS, Milan, Italy"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Andrea","family":"Mandelli","sequence":"additional","affiliation":[{"name":"Department of Biomedical Sciences, Humanitas University, Milan, Italy"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Fabio","family":"Buccolini","sequence":"additional","affiliation":[{"name":"BHOHB S.r.l., Rome, Italy"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Erika","family":"Viola","sequence":"additional","affiliation":[{"name":"BHOHB S.r.l., Rome, Italy"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Damiano","family":"Aguzzi","sequence":"additional","affiliation":[{"name":"BHOHB S.r.l., Rome, Italy"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Roberto","family":"Gatti","sequence":"additional","affiliation":[{"name":"Physiotherapy Unit, Humanitas Clinical and Research Center \u2013 IRCCS, Milan, Italy"},{"name":"Department of Biomedical Sciences, Humanitas University, Milan, Italy"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Isabella","family":"Barajon","sequence":"additional","affiliation":[{"name":"Department of Biomedical Sciences, Humanitas University, Milan, Italy"}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"179","reference":[{"issue":"5-6","key":"10.3233\/THC-220155_ref1","doi-asserted-by":"publisher","first-page":"424","DOI":"10.1007\/s00276-003-0154-6","article-title":"Variability of the spine and pelvis location with respect to the gravity line: A three-dimensional stereoradiographic study using a force platform","volume":"25","author":"Gangnet","year":"2003","journal-title":"Surg Radiol Anat."},{"key":"10.3233\/THC-220155_ref2","doi-asserted-by":"publisher","first-page":"3274864","DOI":"10.1155\/2020\/3274864","article-title":"Influence of global spine sagittal balance and spinal degenerative changes on locomotive syndrome risk in a middle-age and elderly community-living population","volume":"2020","author":"Machino","year":"2020","journal-title":"Biomed Res Int."},{"issue":"S2","key":"10.3233\/THC-220155_ref3","doi-asserted-by":"publisher","first-page":"655","DOI":"10.3233\/THC-182512","article-title":"Low cost self-made pressure distribution sensors for ergonomic chair: Are they suitable for posture monitoring","volume":"26","author":"Martinaitis","year":"2018","journal-title":"Technol Health Care."},{"issue":"3","key":"10.3233\/THC-220155_ref4","doi-asserted-by":"publisher","first-page":"46","DOI":"10.1227\/01.NEU.0000325678.25152.A7","article-title":"Noninvasive measurement and screening techniques for spinal deformities","volume":"63","author":"Harrop","year":"2008","journal-title":"Neurosurgery."},{"issue":"3","key":"10.3233\/THC-220155_ref5","doi-asserted-by":"publisher","first-page":"467","DOI":"10.3233\/THC-140805","article-title":"A study on difference and importance of sacral slope and pelvic sacral angle that affect lumbar curvature","volume":"22","author":"Choi","year":"2014","journal-title":"Technol Health Care."},{"issue":"6","key":"10.3233\/THC-220155_ref6","doi-asserted-by":"publisher","first-page":"729","DOI":"10.1177\/1120700020921120","article-title":"Static and dynamic pelvic kinematics after one-stage bilateral or unilateral total hip arthroplasty","volume":"31","author":"Loppini","year":"2021","journal-title":"Hip Int."},{"issue":"8","key":"10.3233\/THC-220155_ref7","doi-asserted-by":"publisher","first-page":"376","DOI":"10.2519\/jospt.2002.32.8.376","article-title":"Does postural assessment contribute to patient care","volume":"32","author":"Sahrmann","year":"2002","journal-title":"J Orthop Sports Phys Ther."},{"issue":"24","key":"10.3233\/THC-220155_ref8","doi-asserted-by":"publisher","first-page":"8410","DOI":"10.3390\/s21248410","article-title":"A survey of methods and technologies used for diagnosis of scoliosis","volume":"21","author":"Karpiel","year":"2021","journal-title":"Sensors (Basel)."},{"issue":"1","key":"10.3233\/THC-220155_ref9","doi-asserted-by":"publisher","first-page":"10","DOI":"10.1016\/j.math.2013.09.003","article-title":"Reliability and validity of non-radiographic methods of thoracic kyphosis measurement: A systematic review","volume":"19","author":"Barrett","year":"2014","journal-title":"Man Ther."},{"key":"10.3233\/THC-220155_ref10","doi-asserted-by":"publisher","first-page":"357","DOI":"10.1016\/j.gaitpost.2020.12.033","article-title":"Radiography and photogrammetry-based methods of assessing cervical spine posture in the sagittal plane: A systematic review with meta-analysis","volume":"84","author":"Pivotto","year":"2021","journal-title":"Gait Posture."},{"key":"10.3233\/THC-220155_ref11","doi-asserted-by":"publisher","first-page":"248","DOI":"10.1016\/j.jbiomech.2018.08.033","article-title":"Between-session reliability of opto-electronic motion capture in measuring sagittal posture and 3-D ranges of motion of the thoracolumbar spine","volume":"79","author":"Mousavi","year":"2018","journal-title":"J Biomech."},{"issue":"2","key":"10.3233\/THC-220155_ref12","doi-asserted-by":"publisher","first-page":"232","DOI":"10.1016\/j.jelekin.2014.12.007","article-title":"Repeatability of kinematic and electromyographical measures during standing and trunk motion: How many trials are sufficient","volume":"25","author":"Schinkel-Ivy","year":"2015","journal-title":"J Electromyogr Kinesiol."},{"key":"10.3233\/THC-220155_ref13","doi-asserted-by":"publisher","first-page":"110044","DOI":"10.1016\/j.jbiomech.2020.110044","article-title":"Between-session reliability of subject-specific musculoskeletal models of the spine derived from optoelectronic motion capture data","volume":"112","author":"Burkhart","year":"2020","journal-title":"J Biomech."},{"issue":"1","key":"10.3233\/THC-220155_ref14","doi-asserted-by":"publisher","first-page":"49","DOI":"10.1016\/j.medengphy.2013.09.002","article-title":"A wearable inertial system to assess the cervical spine mobility: Comparison with an optoelectronic-based motion capture evaluation","volume":"36","author":"Duc","year":"2014","journal-title":"Med Eng Phys."},{"key":"10.3233\/THC-220155_ref15","doi-asserted-by":"publisher","DOI":"10.3233\/THC-212924"},{"issue":"2","key":"10.3233\/THC-220155_ref16","doi-asserted-by":"publisher","first-page":"136","DOI":"10.5312\/wjo.v7.i2.136","article-title":"Photogrammetry as a tool for the postural evaluation of the spine: A systematic review","volume":"7","author":"Furlanetto","year":"2016","journal-title":"World J Orthop."},{"issue":"2","key":"10.3233\/THC-220155_ref17","doi-asserted-by":"publisher","first-page":"98","DOI":"10.1179\/0886963413Z.00000000014","article-title":"A new posture measurement method for measuring intrinsic standing posture","volume":"32","author":"Kawakami","year":"2014","journal-title":"Cranio."},{"key":"10.3233\/THC-220155_ref18","doi-asserted-by":"publisher","first-page":"891390","DOI":"10.1155\/2015\/891390","article-title":"Techniques and methods for testing the postural function in healthy and pathological subjects","volume":"2015","author":"Paillard","year":"2015","journal-title":"Biomed Res Int."},{"key":"10.3233\/THC-220155_ref19","doi-asserted-by":"publisher","DOI":"10.19193\/0393-6384_2017_4_105k"},{"key":"10.3233\/THC-220155_ref20","doi-asserted-by":"publisher","first-page":"205","DOI":"10.1016\/j.jelekin.2019.08.002","article-title":"Functional and postural recovery after bilateral or unilateral total hip arthroplasty","volume":"48","author":"Temporiti","year":"2019","journal-title":"J Electromyogr Kinesiol."},{"issue":"6","key":"10.3233\/THC-220155_ref21","first-page":"799","article-title":"Perceptive rehabilitation and trunk posture alignment in patients with Parkinson disease: A single blind randomized controlled trial","volume":"52","author":"Morrone","year":"2016","journal-title":"Eur J Phys Rehabil Med."},{"issue":"2","key":"10.3233\/THC-220155_ref22","doi-asserted-by":"publisher","first-page":"142","DOI":"10.23736\/S1973-9087.19.05803-9","article-title":"A novel summary kinematic index for postural characterization in subjects with Parkinson\u2019s disease","volume":"56","author":"Arippa","year":"2020","journal-title":"Eur J Phys Rehabil Med."},{"issue":"2","key":"10.3233\/THC-220155_ref23","doi-asserted-by":"publisher","first-page":"155","DOI":"10.1016\/j.jcm.2016.02.012","article-title":"A guideline of selecting and reporting intraclass correlation coefficients for reliability research","volume":"15","author":"Koo","year":"2016","journal-title":"J Chiropr Med."},{"issue":"6","key":"10.3233\/THC-220155_ref24","doi-asserted-by":"crossref","first-page":"1319","DOI":"10.3233\/BMR-169750","article-title":"Test-retest reliability and validity of a motion capture (MOCAP) system for measuring thoracic and lumbar spinal curvatures and sacral inclination in the sagittal plane","volume":"30","author":"Muyor","year":"2017","journal-title":"J Back Musculoskelet Rehabil."},{"issue":"1","key":"10.3233\/THC-220155_ref25","doi-asserted-by":"publisher","first-page":"27","DOI":"10.1186\/s13013-016-0086-7","article-title":"Adolescent idiopathic scoliosis and back pain","volume":"11","author":"Balagu\u00e9","year":"2016","journal-title":"Scoliosis Spinal Disord."},{"issue":"S2","key":"10.3233\/THC-220155_ref26","doi-asserted-by":"publisher","first-page":"665","DOI":"10.3233\/THC-182513","article-title":"The impact of body mass on spine alterations in pregnant women: A preliminary study","volume":"26","author":"Pauk","year":"2018","journal-title":"Technol Health Care."}],"container-title":["Technology and Health Care"],"original-title":[],"link":[{"URL":"https:\/\/content.iospress.com\/download?id=10.3233\/THC-220155","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,5,1]],"date-time":"2026-05-01T05:55:08Z","timestamp":1777614908000},"score":1,"resource":{"primary":{"URL":"https:\/\/journals.sagepub.com\/doi\/full\/10.3233\/THC-220155"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2023,6,30]]},"references-count":26,"journal-issue":{"issue":"4"},"URL":"https:\/\/doi.org\/10.3233\/thc-220155","relation":{},"ISSN":["0928-7329","1878-7401"],"issn-type":[{"value":"0928-7329","type":"print"},{"value":"1878-7401","type":"electronic"}],"subject":[],"published":{"date-parts":[[2023,6,30]]}}}