{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,8,29]],"date-time":"2026-08-29T05:00:25Z","timestamp":1787979625334,"version":"build-2784847793"},"reference-count":30,"publisher":"SAGE Publications","issue":"4","content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["THC"],"published-print":{"date-parts":[[2023,6,30]]},"abstract":"<jats:p>BACKGROUND: The femoral neck system (FNS) has been considered as a novel strategy for femoral neck fracture. The diversity of internal fixation creates difficulties in choosing an effective option for Pauwels III type femoral neck fractures. Therefore, it is significant to investigate the biomechanical effects of FNS versus conventional approaches on bones. OBJECTIVE: To evaluate the biomechanical characteristics of FNS versus cannulated screws coupled with medial plate (CSS+MP) for the treatment of Pauwels III type femoral neck fractures. METHODS: Through three-dimensional computer software (Minics, Geomagic \u2013 Warp), the proximal femur model was rebuilt. Based on the present clinical characteristics, models of internal fixation were reconstructed in SolidWorks, including cannulated screws (CSS), medial plate (MP) and FNS. After parameter setting and meshing, boundary conditions and loads were set up for the final mechanical calculation in Ansys Software. Under identical experimental conditions, such as the same Pauwels angle and force loading, the peak values of displacement, shear stress and equivalent (von Mises) stress were recorded. RESULTS: This study showed that the displacement of the models was CSS, CSS+MP, and FNS in descending order of magnitude. The shear stress and equivalent stress of the models was CSS+MP, FNS, and CSS in descending order. The principal shear stress of CSS+MP was concentrated on the medial plate. The equivalent stress of FNS was more dispersed and distributed from the proximal main nail to the distal locking screw. CONCLUSION: CSS+MP and FNS exhibited better initial stability compared to CSS. However, the MP was subjected to more shear stress, which could increase the risk of internal fixation failure. Due to its unique design, FNS may be a good choice for the treatment of Pauwels III type femoral neck fractures.<\/jats:p>","DOI":"10.3233\/thc-220267","type":"journal-article","created":{"date-parts":[[2023,3,3]],"date-time":"2023-03-03T10:52:33Z","timestamp":1677840753000},"page":"1161-1170","source":"Crossref","is-referenced-by-count":10,"title":["Biomechanical comparison of femoral neck system and cannulated screws coupled with medial plate for treating Pauwels III femoral neck fractures"],"prefix":"10.1177","volume":"31","author":[{"given":"Chong","family":"Nan","sequence":"first","affiliation":[{"name":"Department of Orthopedics, Baoding No.1 Central Hospital, Baoding, Hebei, China"},{"name":"Department of Orthopedics, Baoding No.1 Central Hospital, Baoding, Hebei, China"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Yanjun","family":"Li","sequence":"additional","affiliation":[{"name":"Department of Orthopedics, Baoding No.1 Central Hospital, Baoding, Hebei, China"},{"name":"Department of Orthopedics, Baoding No.1 Central Hospital, Baoding, Hebei, China"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Yuxiu","family":"Liu","sequence":"additional","affiliation":[{"name":"Department of Neurosurgery, Baoding No.1 Central Hospital, Baoding, Hebei, China"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Liang","family":"Ma","sequence":"additional","affiliation":[{"name":"Department of Orthopedics, Baoding No.1 Central Hospital, Baoding, Hebei, China"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Zhanbei","family":"Ma","sequence":"additional","affiliation":[{"name":"Department of Orthopedics, Baoding No.1 Central Hospital, Baoding, Hebei, China"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"179","reference":[{"issue":"1","key":"10.3233\/THC-220267_ref1","first-page":"236","article-title":"Challenges in the treatment of femoral neck fractures in the nonelderly adult","volume":"68","author":"Davidovitch","year":"2010","journal-title":"J Trauma."},{"issue":"10","key":"10.3233\/THC-220267_ref2","doi-asserted-by":"crossref","first-page":"596","DOI":"10.5435\/00124635-200810000-00005","article-title":"Surgical management of hip fractures: An evidence-based review of the literature. I: Femoral neck fractures","volume":"16","author":"Miyamoto","year":"2008","journal-title":"J Am Acad Orthop Surg."},{"issue":"12","key":"10.3233\/THC-220267_ref3","doi-asserted-by":"crossref","first-page":"1726","DOI":"10.1007\/s00198-006-0172-4","article-title":"An estimate of the worldwide prevalence and disability associated with osteoporotic fractures","volume":"17","author":"Johnell","year":"2006","journal-title":"Osteoporos Int."},{"issue":"1","key":"10.3233\/THC-220267_ref4","doi-asserted-by":"crossref","first-page":"161","DOI":"10.1186\/s13018-016-0498-3","article-title":"An update on the Pauwels classification","volume":"11","author":"Shen","year":"2016","journal-title":"J Orthop Surg Res."},{"issue":"5","key":"10.3233\/THC-220267_ref5","doi-asserted-by":"crossref","first-page":"270","DOI":"10.1097\/BOT.0000000000000014","article-title":"Fracture morphology of high shear angle \u201cvertical\u201d femoral neck fractures in young adult patients","volume":"28","author":"Collinge","year":"2014","journal-title":"J Orthop Trauma."},{"issue":"7","key":"10.3233\/THC-220267_ref6","doi-asserted-by":"crossref","first-page":"1359","DOI":"10.1007\/s00590-018-2207-x","article-title":"Stability of L-shaped and inverted triangle fixation assemblies in treating Pauwels type II femoral neck fracture: A comparative mechanical study","volume":"28","author":"Giordano","year":"2018","journal-title":"Eur J Orthop Surg Traumatol."},{"issue":"1","key":"10.3233\/THC-220267_ref7","doi-asserted-by":"crossref","first-page":"1","DOI":"10.4055\/cios.2019.11.1.1","article-title":"Biomechanical Evaluation of Internal Fixation of Pauwels Type III Femoral Neck Fractures: A Systematic Review of Various Fixation Methods","volume":"11","author":"Cha","year":"2019","journal-title":"Clin Orthop Surg."},{"issue":"1","key":"10.3233\/THC-220267_ref8","doi-asserted-by":"crossref","first-page":"18","DOI":"10.1186\/s40634-019-0187-3","article-title":"The role of the medial plate for Pauwels type III femoral neck fracture: A comparative mechanical study using two fixations with cannulated screws","volume":"6","author":"Giordano","year":"2019","journal-title":"J Exp Orthop."},{"issue":"1","key":"10.3233\/THC-220267_ref9","doi-asserted-by":"crossref","first-page":"352","DOI":"10.1186\/s13018-020-01842-z","article-title":"Dynamic hip screws versus cannulated screws for femoral neck fractures: A systematic review and meta-analysis","volume":"15","author":"Li","year":"2020","journal-title":"J Orthop Surg Res."},{"issue":"1","key":"10.3233\/THC-220267_ref10","doi-asserted-by":"crossref","first-page":"61","DOI":"10.2106\/JBJS.K.01081","article-title":"Risk factors for nonunion in patients with intracapsular femoral neck fractures treated with three cannulated screws placed in either a triangle or an inverted triangle configuration","volume":"95","author":"Yang","year":"2013","journal-title":"J Bone Joint Surg Am."},{"issue":"3","key":"10.3233\/THC-220267_ref11","doi-asserted-by":"crossref","first-page":"144","DOI":"10.1097\/BOT.0000000000000205","article-title":"Biomechanical analysis of augmented plate fixation for the treatment of vertical shear femoral neck fractures","volume":"29","author":"Kunapuli","year":"2015","journal-title":"J Orthop Trauma."},{"key":"10.3233\/THC-220267_ref12","doi-asserted-by":"crossref","first-page":"108658","DOI":"10.1016\/j.biopha.2019.108658","article-title":"Finite element analysis of different internal fixation methods for the treatment of Pauwels type III femoral neck fracture","volume":"112","author":"Tianye","year":"2019","journal-title":"Biomed Pharmacother."},{"issue":"1","key":"10.3233\/THC-220267_ref13","doi-asserted-by":"crossref","first-page":"842","DOI":"10.1186\/s12891-020-03853-7","article-title":"Influence of the proximal screws of buttress plates on the stability of vertical femoral neck fractures: A finite element analysis","volume":"21","author":"Zhan","year":"2020","journal-title":"BMC Musculoskelet Disord."},{"issue":"3","key":"10.3233\/THC-220267_ref14","doi-asserted-by":"crossref","first-page":"131","DOI":"10.1097\/BOT.0000000000000739","article-title":"Biomechanical Evaluation of the Femoral Neck System in Unstable Pauwels III Femoral Neck Fractures: A Comparison with the Dynamic Hip Screw and Cannulated Screws","volume":"31","author":"Stoffel","year":"2017","journal-title":"J Orthop Trauma."},{"key":"10.3233\/THC-220267_ref15","doi-asserted-by":"crossref","first-page":"88","DOI":"10.1016\/j.jot.2020.06.002","article-title":"Higher stability and more predictive fixation with the Femoral Neck System versus Hansson Pins in femoral neck fractures Pauwels II","volume":"24","author":"Schopper","year":"2020","journal-title":"J Orthop Translat."},{"issue":"28","key":"10.3233\/THC-220267_ref16","doi-asserted-by":"crossref","first-page":"e29450","DOI":"10.1097\/MD.0000000000029450","article-title":"Finite element analysis of femoral neck system in the treatment of Pauwels type III femoral neck fracture","volume":"101","author":"Teng","year":"2022","journal-title":"Medicine (Baltimore)."},{"key":"10.3233\/THC-220267_ref17","doi-asserted-by":"crossref","first-page":"106409","DOI":"10.1016\/j.cmpb.2021.106409","article-title":"Biomechanical study of two alternative methods for the treatment of vertical femoral neck fractures \u2013 A finite element analysis","volume":"211","author":"Xia","year":"2021","journal-title":"Comput Methods Programs Biomed."},{"issue":"15","key":"10.3233\/THC-220267_ref18","doi-asserted-by":"crossref","first-page":"3282","DOI":"10.1016\/j.jbiomech.2008.08.013","article-title":"Structural properties of fourth-generation composite femurs and tibias","volume":"41","author":"Heiner","year":"2008","journal-title":"J Biomech."},{"key":"10.3233\/THC-220267_ref19","doi-asserted-by":"crossref","first-page":"2116","DOI":"10.1016\/j.injury.2021.05.043","article-title":"How to choose the suitable FNS specification in young patients with femoral neck fracture: A finite element analysis","volume":"52","author":"Fan","year":"2021","journal-title":"Injury."},{"issue":"11","key":"10.3233\/THC-220267_ref20","doi-asserted-by":"crossref","first-page":"1372","DOI":"10.1016\/j.injury.2011.07.004","article-title":"Biomechanical evaluation of the expansive cannulated screw for fixation of femoral neck fractures","volume":"42","author":"Zhang","year":"2011","journal-title":"Injury."},{"issue":"11","key":"10.3233\/THC-220267_ref21","doi-asserted-by":"crossref","first-page":"1895","DOI":"10.1016\/j.injury.2019.08.024","article-title":"Medial anatomical buttress plate in treating displaced femoral neck fracture a finite element analysis","volume":"50","author":"Li","year":"2019","journal-title":"Injury."},{"issue":"3","key":"10.3233\/THC-220267_ref22","doi-asserted-by":"crossref","first-page":"484","DOI":"10.1016\/j.injury.2014.10.010","article-title":"Complications following young femoral neck fractures","volume":"46","author":"Slobogean","year":"2015","journal-title":"Injury."},{"issue":"4","key":"10.3233\/THC-220267_ref23","doi-asserted-by":"crossref","first-page":"995","DOI":"10.1016\/j.injury.2020.02.075","article-title":"Finite element analysis of different screw constructs in the treatment of unstable femoral neck fractures","volume":"51","author":"Li","year":"2020","journal-title":"Injury."},{"issue":"5","key":"10.3233\/THC-220267_ref24","doi-asserted-by":"crossref","first-page":"429","DOI":"10.1016\/j.mehy.2015.01.029","article-title":"Application of a medial buttress plate may prevent many treatment failures seen after fixation of vertical femoral neck fractures in young adults","volume":"84","author":"Mir","year":"2015","journal-title":"Med Hypotheses."},{"key":"10.3233\/THC-220267_ref25","doi-asserted-by":"crossref","first-page":"621","DOI":"10.1186\/s12891-021-04497-x","article-title":"Improved control over implant anchorage under the use of the femoral neck system for fixation of femoral neck fractures: A technical note","volume":"22","author":"Cha","year":"2021","journal-title":"BMC Musculoskelet Disord."},{"issue":"9","key":"10.3233\/THC-220267_ref26","doi-asserted-by":"crossref","first-page":"1204","DOI":"10.1302\/0301-620X.97B9.34704","article-title":"The terminal branches of the medial femoral circumflex artery: The arterial supply of the femoral head","volume":"97-B","author":"Lazaro","year":"2015","journal-title":"Bone Joint J."},{"issue":"2","key":"10.3233\/THC-220267_ref27","doi-asserted-by":"crossref","first-page":"169","DOI":"10.3233\/BMR-200183","article-title":"Medial femoral plate with cannulated screw for Pauwels type III femoral neck fracture: A meta-analysis","volume":"34","author":"Su","year":"2021","journal-title":"J Back Musculoskelet Rehabil."},{"issue":"1","key":"10.3233\/THC-220267_ref28","doi-asserted-by":"crossref","first-page":"128","DOI":"10.1016\/j.joca.2017.10.009","article-title":"Femoral osteochondroplasty can be performed effectively without the risk of avascular necrosis or femoral neck fractures in an experimental ovine FAI model","volume":"26","author":"Schmaranzer","year":"2018","journal-title":"Osteoarthritis Cartilage."},{"issue":"S1","key":"10.3233\/THC-220267_ref29","doi-asserted-by":"crossref","first-page":"31","DOI":"10.3233\/THC-173857","article-title":"Development and application of computer assisted optimal method for treatment of femoral neck fracture","volume":"26","author":"Wang","year":"2018","journal-title":"Technol Health Care."},{"key":"10.3233\/THC-220267_ref30","doi-asserted-by":"crossref","first-page":"105714","DOI":"10.1016\/j.cmpb.2020.105714","article-title":"Biomechanical evaluation of internal fixation implants for femoral neck fractures: A comparative finite element analysis","volume":"196","author":"Zeng","year":"2020","journal-title":"Comput Methods Programs Biomed."}],"container-title":["Technology and Health Care"],"original-title":[],"link":[{"URL":"https:\/\/content.iospress.com\/download?id=10.3233\/THC-220267","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,5,1]],"date-time":"2026-05-01T05:55:19Z","timestamp":1777614919000},"score":1,"resource":{"primary":{"URL":"https:\/\/journals.sagepub.com\/doi\/full\/10.3233\/THC-220267"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2023,6,30]]},"references-count":30,"journal-issue":{"issue":"4"},"URL":"https:\/\/doi.org\/10.3233\/thc-220267","relation":{},"ISSN":["0928-7329","1878-7401"],"issn-type":[{"value":"0928-7329","type":"print"},{"value":"1878-7401","type":"electronic"}],"subject":[],"published":{"date-parts":[[2023,6,30]]}}}