{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,5,4]],"date-time":"2026-05-04T10:39:57Z","timestamp":1777891197291,"version":"3.51.4"},"reference-count":14,"publisher":"SAGE Publications","license":[{"start":{"date-parts":[[2022,2,25]],"date-time":"2022-02-25T00:00:00Z","timestamp":1645747200000},"content-version":"unspecified","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by-nc\/4.0\/"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["THC"],"published-print":{"date-parts":[[2022,2,25]]},"abstract":"<jats:p>BACKGROUND: The results of urine tests are often affected by improper midstream urine collection time, urine spilling, and urine pollution, all of which can lead to an increase in the test error. OBJECTIVE: To solve this problem, aiming at improving the toilet environment at the hospitals and public physical examination centers, this paper designs an automatic urine collection system. It can automatically adjust the position of the urine cup with an infrared remote controller, or manually, adjust the position of the urine cup in special situations according to the needs of the user. It also has an alarm function. METHODS: The overall size and shape are designed based on the squatting pan, suitable for disposable plastic urine cups of different shapes and sizes. It can realize the automatic collection of midstream urine, manual collection in exceptional cases, emergency stops, and rescue calls. RESULTS: Through the trial survey, there was a significant difference between the statistical results of using the device and not using the device (t= 13.937, P= 0.000). 96% of the subjects thought that the design of the system was reasonable, 22% thought that it was inconvenient to use, and 91.7% of the medical staff thought that the system met the sampling requirements. CONCLUSIONS: Therefore, the trial evaluation is satisfactory, and the proposed collection system is suitable for use in hospitals at all levels and public health examination centers with a large amount of inspection.<\/jats:p>","DOI":"10.3233\/thc-228010","type":"journal-article","created":{"date-parts":[[2022,2,1]],"date-time":"2022-02-01T13:55:44Z","timestamp":1643723744000},"page":"105-114","source":"Crossref","is-referenced-by-count":0,"title":["Design of automatic urine collection system for medical system applications"],"prefix":"10.1177","volume":"30","author":[{"given":"Li","family":"Cheng","sequence":"first","affiliation":[{"name":"Department of Medical Physics, Hebei Medical University, Shijiazhuang, Hebei, China"},{"name":"Key Labarotory of Medical Imaging Research and Application of Hebei Province, Shijiazhuang, Hebei, China"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Chenru","family":"Hao","sequence":"additional","affiliation":[{"name":"Department of Medical Physics, Hebei Medical University, Shijiazhuang, Hebei, China"},{"name":"Key Labarotory of Medical Imaging Research and Application of Hebei Province, Shijiazhuang, Hebei, China"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Yanpeng","family":"Wang","sequence":"additional","affiliation":[{"name":"Department of Electrical and Computer Engineering, Laval University, Quebec, Canada"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Jingjing","family":"Zhang","sequence":"additional","affiliation":[{"name":"Department of Medical Physics, Hebei Medical University, Shijiazhuang, Hebei, China"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Yunlong","family":"Wen","sequence":"additional","affiliation":[{"name":"Shijiazhuang Yuxun Electronics Co., Ltd, Shijiazhuang, Hebei, China"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Ziqiang","family":"Chi","sequence":"additional","affiliation":[{"name":"Department of Medical Physics, Hebei Medical University, Shijiazhuang, Hebei, China"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Xiuyuan","family":"Li","sequence":"additional","affiliation":[{"name":"Department of Foreign Languages, Hebei Medical University, Shijiazhuang, Hebei, China"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Haibo","family":"Yang","sequence":"additional","affiliation":[{"name":"Department of Medical Physics, Hebei Medical University, Shijiazhuang, Hebei, China"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Yanru","family":"Wu","sequence":"additional","affiliation":[{"name":"Department of Medical Physics, Hebei Medical University, Shijiazhuang, Hebei, China"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Lisha","family":"Guo","sequence":"additional","affiliation":[{"name":"Department of Medical Physics, Hebei Medical University, Shijiazhuang, Hebei, China"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Ruibin","family":"Zhao","sequence":"additional","affiliation":[{"name":"Department of Medical Physics, Hebei Medical University, Shijiazhuang, Hebei, China"}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"179","reference":[{"key":"10.3233\/THC-228010_ref1","doi-asserted-by":"publisher","first-page":"227","DOI":"10.1016\/j.compbiomed.2018.04.002","article-title":"Early non-invasive detection of breast cancer using exhaled breath and urine analysis","volume":"96","author":"Or","year":"2018","journal-title":"Computers in Biology and Medicine"},{"issue":"1","key":"10.3233\/THC-228010_ref2","doi-asserted-by":"publisher","first-page":"40","DOI":"10.31797\/vetbio.524209","article-title":"The role of organic urine sediment analysis in the monitoring of renal diseases","volume":"4","author":"Katica","year":"2019","journal-title":"Journal of Advances in VetBio Science and Techniques"},{"issue":"46","key":"10.3233\/THC-228010_ref3","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1186\/s12894-020-00615-4","article-title":"Relationship of endoscopic lesions of the renal papilla with type of renal stone and 24 h urine analysis","volume":"20","author":"Sabat\u00e9 Arroyo","year":"2020","journal-title":"BMC Urology"},{"issue":"1","key":"10.3233\/THC-228010_ref4","doi-asserted-by":"publisher","first-page":"16","DOI":"10.1002\/tre.615","article-title":"Urine sample collection: Issues and a solution","volume":"9","author":"Chinegwundoh","year":"2018","journal-title":"Trends in Urology & Men\u2019s Health"},{"issue":"4","key":"10.3233\/THC-228010_ref5","doi-asserted-by":"publisher","first-page":"845","DOI":"10.6133\/apjcn.201912_28(4).0022","article-title":"Salt intake assessed by spot urine on physical examination in Hunan, China","volume":"28","author":"Yang","year":"2019","journal-title":"Asia Pacific Journal of Clinical Nutrition"},{"key":"10.3233\/THC-228010_ref6","doi-asserted-by":"publisher","DOI":"10.21203\/rs.3.rs-15427\/v1"},{"issue":"4","key":"10.3233\/THC-228010_ref7","doi-asserted-by":"publisher","first-page":"504","DOI":"10.1016\/j.pathol.2020.03.009","article-title":"Cotton wool balls are an effective urine collection tool for CMV PCR for diagnosing congenital cytomegalovirus infection","volume":"52","author":"Singh","year":"2020","journal-title":"Pathology"},{"issue":"6","key":"10.3233\/THC-228010_ref8","doi-asserted-by":"publisher","first-page":"40","DOI":"10.1016\/j.ajic.2019.04.097","article-title":"Implementation of urine collection tubes with preservatives increases accuracy of urine test results and reduces number of CAUTIs reported","volume":"47","author":"Kingsberry","year":"2019","journal-title":"American Journal of Infection Control"},{"issue":"9","key":"10.3233\/THC-228010_ref9","doi-asserted-by":"publisher","first-page":"676","DOI":"10.1111\/nep.13715","article-title":"Regional variance in the use of urine dipstick test for outpatients in Japan","volume":"25","author":"Nishi","year":"2020","journal-title":"Nephrology"},{"key":"10.3233\/THC-228010_ref18","doi-asserted-by":"publisher","DOI":"10.2991\/mcei-18.2018.27"},{"key":"10.3233\/THC-228010_ref19","doi-asserted-by":"publisher","DOI":"10.1063\/1.4977325"},{"issue":"4","key":"10.3233\/THC-228010_ref21","doi-asserted-by":"publisher","first-page":"1104","DOI":"10.1109\/JIOT.2017.2715859","article-title":"IoTtalk-RC: Sensors as universal remote control for aftermarket home appliances","volume":"4","author":"Lin","year":"2017","journal-title":"IEEE Internet of Things Journal"},{"issue":"8","key":"10.3233\/THC-228010_ref23","first-page":"247","article-title":"Automatic toll collection system using RFID","volume":"5","author":"Satyasrikanth","year":"2016","journal-title":"IJCSMC"},{"issue":"11","key":"10.3233\/THC-228010_ref24","doi-asserted-by":"publisher","first-page":"2276","DOI":"10.3390\/app8112276","article-title":"Development of an energy-efficient smart socket based on STM32F103","volume":"8","author":"Ma","year":"2018","journal-title":"Applied Sciences"}],"container-title":["Technology and Health Care"],"original-title":[],"link":[{"URL":"https:\/\/content.iospress.com\/download?id=10.3233\/THC-228010","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,5,1]],"date-time":"2026-05-01T05:56:51Z","timestamp":1777615011000},"score":1,"resource":{"primary":{"URL":"https:\/\/journals.sagepub.com\/doi\/full\/10.3233\/THC-228010"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2022,2,25]]},"references-count":14,"URL":"https:\/\/doi.org\/10.3233\/thc-228010","relation":{},"ISSN":["0928-7329","1878-7401"],"issn-type":[{"value":"0928-7329","type":"print"},{"value":"1878-7401","type":"electronic"}],"subject":[],"published":{"date-parts":[[2022,2,25]]}}}