{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,5,4]],"date-time":"2026-05-04T10:17:05Z","timestamp":1777889825085,"version":"3.51.4"},"reference-count":27,"publisher":"SAGE Publications","issue":"6","content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["THC"],"published-print":{"date-parts":[[2024,11,8]]},"abstract":"<jats:p>BACKGROUND: Rib fractures are one of the most common blunt injuries, accounting for approximately 10% of all trauma patients and 60% of thoracic injuries. Multiple rib fractures, especially flail chest, can cause local chest wall softening due to the loss of rib support, leading to paradoxical breathing, severe pain, and a high likelihood of accompanying lung contusions. OBJECTIVE: This study investigates the mechanical properties of a new polymer material rib internal fixator to provide theoretical data for its clinical use. METHODS: We conducted in vitro mechanical tests on 20 fresh caudal fin sheep ribs, using different fracture models across four randomly assigned groups (five ribs per group). The fixators were assessed using non-destructive three-point bending, torsion, and unilateral compression tests, with results averaged. Additionally, finite element analysis compared stress and strain in the polymer fixators and titanium alloy rib plates during bending and torsion tests. RESULTS: In vitro tests showed that the polymer fixators handled loads effectively up to a maximum without increase beyond a certain displacement. Bending and torsion tests via finite element analysis showed the polymer material sustained lower maximum equivalent stresses (84.455\u00a0MPa and 14.426\u00a0MPa) compared to titanium alloy plates (219.88\u00a0MPa and 46.47\u00a0MPa). CONCLUSION: The polymer rib fixator demonstrated sufficient strength for rib fracture fixation and was superior in stress management compared to titanium alloy plates in both bending and torsion tests, supporting its potential clinical application.<\/jats:p>","DOI":"10.3233\/thc-240928","type":"journal-article","created":{"date-parts":[[2024,8,2]],"date-time":"2024-08-02T09:45:03Z","timestamp":1722591903000},"page":"4681-4694","source":"Crossref","is-referenced-by-count":1,"title":["A biomechanical study of a polymer material bundled rib fracture fixator"],"prefix":"10.1177","volume":"32","author":[{"given":"Yongmin","family":"Zhang","sequence":"first","affiliation":[{"name":"Department of Cardiothoracic Surgery, Tianjin Hospital Affiliated to Tianjin University, Tianjin, China"},{"name":"Department of Cardiothoracic Surgery, Tianjin Hospital Affiliated to Tianjin University, Tianjin, China"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Dongbin","family":"Wang","sequence":"additional","affiliation":[{"name":"Department of Cardiothoracic Surgery, Tianjin Hospital Affiliated to Tianjin University, Tianjin, China"},{"name":"Department of Cardiothoracic Surgery, Tianjin Hospital Affiliated to Tianjin University, Tianjin, China"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Hao","family":"Gong","sequence":"additional","affiliation":[{"name":"Department of Cardiothoracic Surgery, Tianjin Hospital Affiliated to Tianjin University, Tianjin, China"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Haosen","family":"Tang","sequence":"additional","affiliation":[{"name":"Graduate School, Tianjin Medical University, Tianjin, China"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Guangqi","family":"Dong","sequence":"additional","affiliation":[{"name":"Graduate School, Tianjin Medical University, Tianjin, China"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Bin","family":"Wang","sequence":"additional","affiliation":[{"name":"School of Materials, Tianjin University, Tianjin, China"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Honggang","family":"Xia","sequence":"additional","affiliation":[{"name":"Department of Cardiothoracic Surgery, Tianjin Hospital Affiliated to Tianjin University, Tianjin, China"}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"179","reference":[{"issue":"2","key":"10.3233\/THC-240928_ref1","doi-asserted-by":"publisher","first-page":"411","DOI":"10.1097\/TA.0000000000002716","article-title":"Complications and outcome after rib fracture fixation: A systematic review","volume":"89","author":"Peek","year":"2020","journal-title":"J Trauma Acute Care Surg."},{"key":"10.3233\/THC-240928_ref2","doi-asserted-by":"publisher","first-page":"105805","DOI":"10.1016\/j.ijscr.2021.105805","article-title":"Surgical stabilization of severe flail chest with Judet and Sanchez-Lloret plates: A case report","volume":"81","author":"Stefani","year":"2021","journal-title":"Int J Surg Case Rep."},{"issue":"6","key":"10.3233\/THC-240928_ref3","doi-asserted-by":"publisher","first-page":"2179","DOI":"10.1016\/j.athoracsur.2013.08.066","article-title":"Thoracoscopy-assisted minimally invasive surgical stabilization of the anterolateral flail chest using Nuss bar","volume":"97","author":"Ke","year":"2014","journal-title":"Ann Thorac Surg."},{"issue":"1","key":"10.3233\/THC-240928_ref4","doi-asserted-by":"publisher","first-page":"39","DOI":"10.1053\/j.semtcvs.2008.01.004","article-title":"Flail chest and pulmonary contusion","volume":"20","author":"Bastos","year":"2008","journal-title":"Semin Thorac Cardiovasc Surg."},{"issue":"1","key":"10.3233\/THC-240928_ref5","doi-asserted-by":"publisher","first-page":"8","DOI":"10.1055\/s-0035-1558433","article-title":"A Case of Traumatic Flail Chest Requiring Stabilization with Surgical Reconstruction","volume":"4","author":"Evman","year":"2015","journal-title":"Thorac Cardiovasc Surg Rep."},{"issue":"5","key":"10.3233\/THC-240928_ref6","doi-asserted-by":"publisher","first-page":"2890","DOI":"10.21037\/jtd.2018.04.116","article-title":"The painless combination of anatomically contoured titanium plates and porcine dermal collagen patch for chest wall reconstruction","volume":"10","author":"Ong","year":"2018","journal-title":"J Thorac Dis."},{"key":"10.3233\/THC-240928_ref7","doi-asserted-by":"publisher","first-page":"960310","DOI":"10.3389\/fbioe.2022.960310","article-title":"Finite element analysis of different fixation methods of screws on absorbable plate for rib fractures","volume":"10","author":"Xue","year":"2022","journal-title":"Front Bioeng Biotechnol."},{"issue":"4","key":"10.3233\/THC-240928_ref8","doi-asserted-by":"publisher","first-page":"473","DOI":"10.1016\/j.thorsurg.2006.12.010","article-title":"The anatomy of the ribs and the sternum and their relationship to chest wall structure and function","volume":"17","author":"Graeber","year":"2007","journal-title":"Thorac Surg Clin."},{"issue":"4","key":"10.3233\/THC-240928_ref9","doi-asserted-by":"publisher","first-page":"1642","DOI":"10.1152\/japplphysiol.01053.2001","article-title":"On the respiratory function of the ribs","volume":"92","author":"Cappello","year":"2002","journal-title":"J Appl Physiol."},{"issue":"Pt 2","key":"10.3233\/THC-240928_ref10","doi-asserted-by":"publisher","first-page":"319","DOI":"10.1111\/j.1469-7793.2001.0319l.x","article-title":"Respiratory effects of the external and internal intercostal muscles in humans","volume":"530","author":"Wilson","year":"2001","journal-title":"J Physiol."},{"issue":"5","key":"10.3233\/THC-240928_ref11","doi-asserted-by":"publisher","first-page":"1872","DOI":"10.1152\/jappl.1987.62.5.1872","article-title":"Geometry and respiratory displacement of human ribs","volume":"62","author":"Wilson","year":"1987","journal-title":"J Appl Physiol."},{"issue":"5","key":"10.3233\/THC-240928_ref12","doi-asserted-by":"publisher","first-page":"1270","DOI":"10.1097\/TA.0b013e31804a7fd5","article-title":"Biomechanical testing of a novel, minimally invasive rib fracture plating system","volume":"64","author":"Sales","year":"2008","journal-title":"J Trauma."},{"issue":"11","key":"10.3233\/THC-240928_ref13","first-page":"808","article-title":"Biomechanical study of embracing and non-embracing rib plates","volume":"21","author":"Huang","year":"2019","journal-title":"J Trauma Surgery."},{"issue":"6","key":"10.3233\/THC-240928_ref14","doi-asserted-by":"publisher","first-page":"1612","DOI":"10.1111\/jam.14290","article-title":"Polylactic acid: Synthesis and biomedical applications","volume":"127","author":"Singhvi","year":"2019","journal-title":"J Appl Microbiol."},{"issue":"12","key":"10.3233\/THC-240928_ref15","doi-asserted-by":"publisher","first-page":"1335","DOI":"10.1007\/s10118-020-2439-1","article-title":"Refractive index engineering as a novel strategy toward highly transparent and tough sustainable polymer blends","volume":"38","author":"Sun","year":"2020","journal-title":"Chin J Polym Sci."},{"issue":"8","key":"10.3233\/THC-240928_ref16","doi-asserted-by":"publisher","first-page":"2234","DOI":"10.1002\/cjoc.202100217","article-title":"Novel designed PEG-dicationic imidazolium-based ionic liquids as effective plasticizers for sustainable polylactide","volume":"39","author":"Zuo","year":"2021","journal-title":"Chin J Chem."},{"issue":"6","key":"10.3233\/THC-240928_ref17","doi-asserted-by":"publisher","first-page":"3091","DOI":"10.1021\/am3004522","article-title":"Fully biodegradable and biorenewable ternary blends from polylactide, poly(3-hydroxybutyrate-co-hydroxyvalerate) and poly(butylene succinate) with balanced properties","volume":"4","author":"Zhang","year":"2012","journal-title":"ACS Appl Mater Interfaces."},{"issue":"10","key":"10.3233\/THC-240928_ref18","doi-asserted-by":"publisher","first-page":"2345","DOI":"10.1021\/sc500353v","article-title":"Toughened sustainable green composites from poly(3-hydroxybutyrate-co-3-hydroxyvalerate) based ternary blends and miscanthus biofiber","volume":"2","author":"Zhang","year":"2014","journal-title":"ACS Sustainable Chem Eng."},{"issue":"48","key":"10.3233\/THC-240928_ref19","doi-asserted-by":"publisher","first-page":"8388","DOI":"10.3969\/j.issn.2095-4344.2013.48.015","article-title":"Biomechanical properties of a magnesium alloy absorbable rib intramedullary nail","volume":"17","author":"Teng","year":"2013","journal-title":"Chin J Tissue Eng Res."},{"issue":"1","key":"10.3233\/THC-240928_ref20","doi-asserted-by":"publisher","first-page":"573","DOI":"10.1021\/acssuschemeng.9b06123","article-title":"Functionalized elastomeric ionomers used as effective toughening agents for poly(lactic acid): Enhancement in interfacial adhesion and mechanical performance","volume":"8","author":"Huang","year":"2020","journal-title":"ACS Sustainable Chem Eng."},{"key":"10.3233\/THC-240928_ref21","doi-asserted-by":"publisher","first-page":"123964","DOI":"10.1016\/j.polymer.2021.123964","article-title":"Combining novel polyether-based ionomers and polyethylene glycol as effective toughening agents for polylactide","volume":"229","author":"Wang","year":"2021","journal-title":"Polymer."},{"issue":"12","key":"10.3233\/THC-240928_ref22","doi-asserted-by":"publisher","first-page":"1335","DOI":"10.1007\/s10118-020-2439-1","article-title":"Refractive index engineering as a novel strategy toward highly transparent and tough sustainable polymer blends","volume":"38","author":"Sun","year":"2020","journal-title":"Chin J Polym Sci."},{"key":"10.3233\/THC-240928_ref23","doi-asserted-by":"crossref","unstructured":"Hrvat F, Spahic L, Gurbeta Pokvic L, Badnjevic A, Artificial Neural Networks for prediction of medical device performance based on conformity assessment data: Infusion and perfusor pumps case study? IEEE 9th Mediterranean Conference on Embedded Computing (MECO), 08-11 June 2020, Budva, Montenegro","DOI":"10.1109\/MECO49872.2020.9134359"},{"key":"10.3233\/THC-240928_ref24","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1109\/BIBE523082021.9635307","article-title":"\u201cThe Use of Artificial Intelligence in Diagnostic Medical Imaging: Systematic Literature Review,\u201d","author":"Hafizovi\u0107","year":"2021","journal-title":"2021 IEEE 21st International Conference on Bioinformatics and Bioengineering (BIBE)"},{"key":"10.3233\/THC-240928_ref25","doi-asserted-by":"crossref","unstructured":"Spahi\u0107 L, Kurta E, Cordic S, Becirovic M, Gurbeta L, Kovacevic Z, et al. Machine Learning Techniques for Performance Prediction of Medical Devices: Infant Incubators. In: Badnjevic A, \u0160krbi\u0107 R, Gurbeta Pokvi\u0107 L. (eds) CMBEBIH 2019. CMBEBIH 2019. IFMBE Proceedings, vol 73. Springer, Cham.","DOI":"10.1007\/978-3-030-17971-7_72"},{"key":"10.3233\/THC-240928_ref26","doi-asserted-by":"publisher","DOI":"10.1007\/978-981-10-4166-293"},{"key":"10.3233\/THC-240928_ref27","doi-asserted-by":"crossref","unstructured":"Badnjevic A, Cifrek M, Koruga D. \u201cClassification of Chronic Obstructive Pulmonary Disease (COPD) using integrated software suite\u201d, IFMBE XIII Mediterranean Conference on Medical and Biological Engineering and Computing (MEDICON), 25\u201328. September 2013. Sevilla, Spain.","DOI":"10.1007\/978-3-319-00846-2_225"}],"container-title":["Technology and Health Care"],"original-title":[],"link":[{"URL":"https:\/\/content.iospress.com\/download?id=10.3233\/THC-240928","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,5,1]],"date-time":"2026-05-01T05:20:42Z","timestamp":1777612842000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.medra.org\/servlet\/aliasResolver?alias=iospress&doi=10.3233\/THC-240928"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2024,11,8]]},"references-count":27,"journal-issue":{"issue":"6"},"URL":"https:\/\/doi.org\/10.3233\/thc-240928","relation":{},"ISSN":["0928-7329","1878-7401"],"issn-type":[{"value":"0928-7329","type":"print"},{"value":"1878-7401","type":"electronic"}],"subject":[],"published":{"date-parts":[[2024,11,8]]}}}