{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,9,30]],"date-time":"2026-09-30T13:40:41Z","timestamp":1790775641309,"version":"4.1.0"},"reference-count":21,"publisher":"SAGE Publications","issue":"1","license":[{"start":{"date-parts":[[2024,2,22]],"date-time":"2024-02-22T00:00:00Z","timestamp":1708560000000},"content-version":"unspecified","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by-nc\/4.0\/"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["VES"],"published-print":{"date-parts":[[2024,2,22]]},"abstract":"<jats:p>The computerized rotational head impulse test (crHIT) uses a computer-controlled rotational chair to deliver whole-body rotational impulses to assess the semicircular canals. The crHIT has only been described for horizontal head plane rotations. The purpose of this study was to describe the crHIT for vertical head plane rotations. In this preliminary study, we assessed four patients with surgically confirmed unilateral peripheral vestibular abnormalities and two control subjects. Results indicated that the crHIT was well-tolerated for both horizontal head plane and vertical head plane stimuli. The crHIT successfully assessed each of the six semicircular canals. This study suggests that the crHIT has the potential to become a new laboratory-based vestibular test for both the horizontal and vertical semicircular canals.<\/jats:p>","DOI":"10.3233\/ves-230121","type":"journal-article","created":{"date-parts":[[2024,2,23]],"date-time":"2024-02-23T11:37:36Z","timestamp":1708688256000},"page":"29-38","source":"Crossref","is-referenced-by-count":4,"title":["The vertical computerized rotational head impulse test"],"prefix":"10.1177","volume":"34","author":[{"given":"Joseph M.","family":"Furman","sequence":"first","affiliation":[{"name":"Department of Otolaryngology, University of Pittsburgh, Pittsburgh, PA, USA"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Ian","family":"Shirey","sequence":"additional","affiliation":[{"name":"Neurolign USA, Pittsburgh, PA, USA"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Jillyn","family":"Roxberg","sequence":"additional","affiliation":[{"name":"Department of Otolaryngology, University of Pittsburgh, Pittsburgh, PA, USA"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Alexander","family":"Kiderman","sequence":"additional","affiliation":[{"name":"Neurolign USA, Pittsburgh, PA, USA"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"179","reference":[{"issue":"2","key":"10.3233\/VES-230121_ref1","doi-asserted-by":"crossref","first-page":"e113","DOI":"10.1097\/MAO.0000000000001665","article-title":"Intra- and interexaminer variability of two separate video head impulse test systems assessing all six semicircular canals","volume":"39","author":"Abrahamsen","year":"2018","journal-title":"Otol Neurotol"},{"issue":"2-3","key":"10.3233\/VES-230121_ref2","doi-asserted-by":"crossref","first-page":"163","DOI":"10.3233\/VES-170614","article-title":"Differences in head impulse test results due to analysis techniques","volume":"27","author":"Cleworth","year":"2017","journal-title":"J Vestib Res"},{"issue":"Pt 4","key":"10.3233\/VES-230121_ref3","doi-asserted-by":"crossref","first-page":"699","DOI":"10.1093\/brain\/121.4.699","article-title":"Semicircular canal plane head impulses detect absent function of individual semicircular canals","volume":"121","author":"Cremer","year":"1998","journal-title":"Brain"},{"issue":"3","key":"10.3233\/VES-230121_ref4","doi-asserted-by":"crossref","first-page":"191","DOI":"10.1007\/s10162-005-0003-x","article-title":"Orientation of human semicircular canals measured by three-dimensional multiplanar CT reconstruction","volume":"6","author":"Santina","year":"2005","journal-title":"J Assoc Res Otolaryngol"},{"key":"10.3233\/VES-230121_ref5","unstructured":"Furman J.M. , Roxberg J. , Shirey I. and Kiderman A. , The vertical computerized roational head impulse test (crHIT-vertical) Vestibular-Oriented Research meeting The Ohio State University May 20\u201322, 2019."},{"issue":"5-6","key":"10.3233\/VES-230121_ref6","doi-asserted-by":"crossref","first-page":"447","DOI":"10.3233\/VES-160595","article-title":"The horizontal computerized rotational impulse test","volume":"26","author":"Furman","year":"2016","journal-title":"J Vestib Res"},{"key":"10.3233\/VES-230121_ref7","doi-asserted-by":"crossref","first-page":"258","DOI":"10.3389\/fneur.2017.00258","article-title":"The video head impulse test","volume":"8","author":"Halmagyi","year":"2017","journal-title":"Front Neurol"},{"issue":"7","key":"10.3233\/VES-230121_ref8","doi-asserted-by":"crossref","first-page":"737","DOI":"10.1001\/archneur.1988.00520310043015","article-title":"A clinical sign of canal paresis","volume":"45","author":"Halmagyi","year":"1988","journal-title":"Arch Neurol"},{"issue":"2","key":"10.3233\/VES-230121_ref9","doi-asserted-by":"crossref","first-page":"187","DOI":"10.3233\/VES-1991-1210","article-title":"Head impulses after unilateral vestibular deafferentation validate Ewald\u2019s second law","volume":"1","author":"Halmagyi","year":"1990","journal-title":"J Vestib Res"},{"issue":"3","key":"10.3233\/VES-230121_ref10","doi-asserted-by":"crossref","first-page":"479","DOI":"10.1007\/BF02423496","article-title":"The human horizontal vestibulo-ocular reflex in response to high-acceleration stimulation before and after unilateral vestibular neurectomy","volume":"81","author":"Halmagyi","year":"1990","journal-title":"Exp Brain Res"},{"issue":"4","key":"10.3233\/VES-230121_ref11","doi-asserted-by":"crossref","first-page":"e61488","DOI":"10.1371\/journal.pone.0061488","article-title":"The video Head Impulse Test (vHIT) detects vertical semicircular canal dysfunction,","volume":"8","author":"Macdougall","year":"2013","journal-title":"PLoS One"},{"issue":"14","key":"10.3233\/VES-230121_ref12","doi-asserted-by":"crossref","first-page":"1134","DOI":"10.1212\/WNL.0b013e3181bacf85","article-title":"The video head impulse test: diagnostic accuracy in peripheral vestibulopathy","volume":"73","author":"MacDougall","year":"2009","journal-title":"Neurology"},{"key":"10.3233\/VES-230121_ref13","doi-asserted-by":"crossref","first-page":"58","DOI":"10.3389\/fneur.2015.00058","article-title":"Horizontal eye position affects measured vertical VOR gain on the video head impulse test","volume":"6","author":"McGarvie","year":"2015","journal-title":"Front Neurol"},{"issue":"2","key":"10.3233\/VES-230121_ref14","doi-asserted-by":"crossref","first-page":"140","DOI":"10.1007\/s10162-006-0029-8","article-title":"Axis of eye rotation changes with head-pitch orientation during head impulses about earth-vertical","volume":"7","author":"Migliaccio","year":"2006","journal-title":"J Assoc Res Otolaryngol"},{"issue":"1","key":"10.3233\/VES-230121_ref15","doi-asserted-by":"crossref","first-page":"5","DOI":"10.18203\/issn.2454-5929.ijohns20223373","article-title":"Test-retest reliability of the computerized rotational head impulse test in the pediatric population","volume":"9","author":"Mittendorf","year":"2023","journal-title":"Internaional Journal of Otorhinolaryngology and Head and Neck Surgery"},{"issue":"5-6","key":"10.3233\/VES-230121_ref16","doi-asserted-by":"crossref","first-page":"291","DOI":"10.3233\/VES-2005-155-606","article-title":"Pulse-step-sine rotation test for the identification of abnormal vestibular function","volume":"15","author":"Peterka","year":"2005","journal-title":"J Vestib Res"},{"issue":"11","key":"10.3233\/VES-230121_ref17","doi-asserted-by":"crossref","first-page":"3595","DOI":"10.1007\/s00405-016-3979-4","article-title":"Head position and increased head velocity to optimize video head impulse test sensitivity","volume":"273","author":"Seo","year":"2016","journal-title":"Eur Arch Otorhinolaryngol"},{"issue":"6","key":"10.3233\/VES-230121_ref18","doi-asserted-by":"crossref","first-page":"454","DOI":"10.1212\/01.wnl.0000299117.48935.2e","article-title":"Head impulse test in unilateral vestibular loss: vestibulo-ocular reflex and catch-up saccades","volume":"70","author":"Weber","year":"2008","journal-title":"Neurology"},{"key":"10.3233\/VES-230121_ref19","doi-asserted-by":"crossref","first-page":"692196","DOI":"10.3389\/fneur.2021.692196","article-title":"vHIT testing of vertical semicircular canals with goggles yield different results depending on which canal plane being tested","volume":"12","author":"Wittmeyer Cedervall","year":"2021","journal-title":"Front Neurol"},{"issue":"Suppl8","key":"10.3233\/VES-230121_ref20","first-page":"23","article-title":"Principle of the head impulse (thrust) test of Halmagyi Head Thrust Test (HHTT)","volume":"4","author":"Wuyts","year":"2008","journal-title":"B-ENT"},{"issue":"4","key":"10.3233\/VES-230121_ref21","doi-asserted-by":"crossref","first-page":"225","DOI":"10.3233\/VES-200708","article-title":"VOR gain calculation methods in video head impulse recordings","volume":"30","author":"Zamaro","year":"2020","journal-title":"J Vestib Res"}],"container-title":["Journal of Vestibular Research"],"original-title":[],"link":[{"URL":"https:\/\/content.iospress.com\/download?id=10.3233\/VES-230121","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,5,1]],"date-time":"2026-05-01T05:26:44Z","timestamp":1777613204000},"score":1,"resource":{"primary":{"URL":"https:\/\/journals.sagepub.com\/doi\/full\/10.3233\/VES-230121"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2024,2,22]]},"references-count":21,"journal-issue":{"issue":"1"},"URL":"https:\/\/doi.org\/10.3233\/ves-230121","relation":{},"ISSN":["0957-4271","1878-6464"],"issn-type":[{"value":"0957-4271","type":"print"},{"value":"1878-6464","type":"electronic"}],"subject":[],"published":{"date-parts":[[2024,2,22]]}}}