{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,30]],"date-time":"2026-10-30T17:27:16Z","timestamp":1793381236960,"version":"4.5.0"},"reference-count":153,"publisher":"National Institute for Health and Care Research","issue":"4","license":[{"start":{"date-parts":[[2015,1,1]],"date-time":"2015-01-01T00:00:00Z","timestamp":1420070400000},"content-version":"unspecified","delay-in-days":0,"URL":"http:\/\/www.nationalarchives.gov.uk\/doc\/non-commercial-government-licence\/non-commercial-government-licence.htm"}],"funder":[{"DOI":"10.13039\/501100000276","name":"National Institute for Health Research","doi-asserted-by":"publisher","award":["09\/22\/182"],"award-info":[{"award-number":["09\/22\/182"]}],"id":[{"id":"10.13039\/501100000276","id-type":"DOI","asserted-by":"publisher"}]}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":[],"abstract":"<jats:sec id=\"abs1-1\">\n                    <jats:title>Background<\/jats:title>\n                    <jats:p>Digital breast tomosynthesis (DBT) is a three-dimensional mammography technique with the potential to improve accuracy by improving differentiation between malignant and non-malignant lesions.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec id=\"abs1-2\">\n                    <jats:title>Objectives<\/jats:title>\n                    <jats:p>The objectives of the study were to compare the diagnostic accuracy of DBT in conjunction with two-dimensional (2D) mammography or synthetic 2D mammography, against standard 2D mammography and to determine if DBT improves the accuracy of detection of different types of lesions.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec id=\"abs1-3\">\n                    <jats:title>Study population<\/jats:title>\n                    <jats:p>Women (aged 47\u201373 years) recalled for further assessment after routine breast screening and women (aged 40\u201349 years) with moderate\/high of risk of developing breast cancer attending annual mammography screening were recruited after giving written informed consent.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec id=\"abs1-4\">\n                    <jats:title>Intervention<\/jats:title>\n                    <jats:p>All participants underwent a two-view 2D mammography of both breasts and two-view DBT imaging. Image-processing software generated a synthetic 2D mammogram from the DBT data sets.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec id=\"abs1-5\">\n                    <jats:title>Retrospective reading study<\/jats:title>\n                    <jats:p>In an independent blinded retrospective study, readers reviewed (1) 2D or (2) 2D\u2009+\u2009DBT or (3) synthetic 2D\u2009+\u2009DBT images for each case without access to original screening mammograms or prior examinations. Sensitivities and specificities were calculated for each reading arm and by subgroup analyses.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec id=\"abs1-6\">\n                    <jats:title>Results<\/jats:title>\n                    <jats:p>\n                      Data were available for 7060 subjects comprising 6020 (1158 cancers) assessment cases and 1040 (two cancers) family history screening cases. Overall sensitivity was 87% [95% confidence interval (CI) 85% to 89%] for 2D only, 89% (95% CI 87% to 91%) for 2D\u2009+\u2009DBT and 88% (95% CI 86% to 90%) for synthetic 2D\u2009+\u2009DBT. The difference in sensitivity between 2D and 2D\u2009+\u2009DBT was of borderline significance (\n                      <jats:italic>p<\/jats:italic>\n                      \u2009=\u20090.07) and for synthetic 2D\u2009+\u2009DBT there was no significant difference (\n                      <jats:italic>p<\/jats:italic>\n                      \u2009=\u20090.6). Specificity was 58% (95% CI 56% to 60%) for 2D, 69% (95% CI 67% to 71%) for 2D\u2009+\u2009DBT and 71% (95% CI 69% to 73%) for synthetic 2D\u2009+\u2009DBT. Specificity was significantly higher in both DBT reading arms for all subgroups of age, density and dominant radiological feature (\n                      <jats:italic>p<\/jats:italic>\n                      \u2009&lt;\u20090.001 all cases). In all reading arms, specificity tended to be lower for microcalcifications and higher for distortion\/asymmetry. Comparing 2D\u2009+\u2009DBT to 2D alone, sensitivity was significantly higher: 93% versus 86% (\n                      <jats:italic>p<\/jats:italic>\n                      \u2009&lt;\u20090.001) for invasive tumours of size 11\u201320\u2009mm. Similarly, for breast density 50% or more, sensitivities were 93% versus 86% (\n                      <jats:italic>p<\/jats:italic>\n                      \u2009=\u20090.03); for grade 2 invasive tumours, sensitivities were 91% versus 87% (\n                      <jats:italic>p<\/jats:italic>\n                      \u2009=\u20090.01); where the dominant radiological feature was a mass, sensitivities were 92% and 89% (\n                      <jats:italic>p<\/jats:italic>\n                      \u2009=\u20090.04) For synthetic 2D\u2009+\u2009DBT, there was significantly (\n                      <jats:italic>p<\/jats:italic>\n                      \u2009=\u20090.006) higher sensitivity than 2D alone in invasive cancers of size 11\u201320\u2009mm, with a sensitivity of 91%.\n                    <\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec id=\"abs1-7\">\n                    <jats:title>Conclusions<\/jats:title>\n                    <jats:p>The specificity of DBT and 2D was better than 2D alone but there was only marginal improvement in sensitivity. The performance of synthetic 2D appeared to be comparable to standard 2D. If these results were observed with screening cases, DBT and 2D mammography could benefit to the screening programme by reducing the number of women recalled unnecessarily, especially if a synthetic 2D mammogram were used to minimise radiation exposure. Further research is required into the feasibility of implementing DBT in a screening setting, prognostic modelling on outcomes and mortality, and comparison of 2D and synthetic 2D for different lesion types.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec id=\"abs1-8\">\n                    <jats:title>Study registration<\/jats:title>\n                    <jats:p>Current Controlled Trials ISRCTN73467396.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec id=\"abs1-9\">\n                    <jats:title>Funding<\/jats:title>\n                    <jats:p>\n                      This project was funded by the NIHR Health Technology Assessment programme and will be published in full in\n                      <jats:italic>Health Technology Assessment<\/jats:italic>\n                      ; Vol. 19, No. 4. See the HTA programme website for further project information.\n                    <\/jats:p>\n                  <\/jats:sec>","DOI":"10.3310\/hta19040","type":"journal-article","created":{"date-parts":[[2015,1,20]],"date-time":"2015-01-20T05:26:28Z","timestamp":1421731588000},"page":"1-136","update-policy":"https:\/\/doi.org\/10.3310\/crossmarkpolicy","source":"Crossref","is-referenced-by-count":154,"title":["The TOMMY trial: a comparison of TOMosynthesis with digital MammographY in the UK NHS Breast Screening Programme \u2013 a multicentre retrospective reading study comparing the diagnostic performance of digital breast tomosynthesis and digital mammography with digital mammography alone"],"prefix":"10.3310","volume":"19","clinical-trial-number":[{"clinical-trial-number":"isrctn73467396","registry":"10.18810\/isrctn","type":"results"}],"author":[{"given":"Fiona J","family":"Gilbert","sequence":"first","affiliation":[{"name":"Department of Radiology, University of Cambridge, Cambridge, UK"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Lorraine","family":"Tucker","sequence":"additional","affiliation":[{"name":"Department of Radiology, University of Cambridge, Cambridge, UK"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Maureen GC","family":"Gillan","sequence":"additional","affiliation":[{"name":"Aberdeen Biomedical Imaging Centre, University of Aberdeen, Aberdeen, UK"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Paula","family":"Willsher","sequence":"additional","affiliation":[{"name":"Department of Radiology, University of Cambridge, Cambridge, UK"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Julie","family":"Cooke","sequence":"additional","affiliation":[{"name":"Jarvis Breast Centre, Guildford, UK"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Karen A","family":"Duncan","sequence":"additional","affiliation":[{"name":"North East Scotland Breast Screening Centre, Aberdeen, UK"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Michael J","family":"Michell","sequence":"additional","affiliation":[{"name":"Breast Radiology, King\u2019s College Hospital, London, UK"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Hilary M","family":"Dobson","sequence":"additional","affiliation":[{"name":"West of Scotland Breast Screening Service, Glasgow, UK"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Yit Yoong","family":"Lim","sequence":"additional","affiliation":[{"name":"The Nightingale Centre, University Hospital South Manchester, Manchester, UK"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Hema","family":"Purushothaman","sequence":"additional","affiliation":[{"name":"Department of Radiology, St Bartholomew\u2019s Hospital, London, UK"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Celia","family":"Strudley","sequence":"additional","affiliation":[{"name":"National Co-ordinating Centre for Physics of Mammography, Royal Surrey County Hospital, Guildford, UK"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Susan M","family":"Astley","sequence":"additional","affiliation":[{"name":"Department of Imaging Science and Biomedical Engineering, University of Manchester, Manchester, UK"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Oliver","family":"Morrish","sequence":"additional","affiliation":[{"name":"East Anglian Regional Radiation Protection Service, Cambridge University Hospitals, Cambridge, UK"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Kenneth C","family":"Young","sequence":"additional","affiliation":[{"name":"National Co-ordinating Centre for Physics of Mammography, Royal Surrey County Hospital, Guildford, UK"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Stephen W","family":"Duffy","sequence":"additional","affiliation":[{"name":"Wolfson Institute of Preventive Medicine, Queen Mary University of London, London, UK"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"6221","published-online":{"date-parts":[[2015,1]]},"reference":[{"key":"key20150119112946185_ref1-bib1","doi-asserted-by":"publisher","first-page":"1778","DOI":"10.1016\/S0140-6736(12)61611-0","article-title":"The benefits and harms of breast cancer screening: an independent review","volume":"380","author":"","year":"2012","journal-title":"Lancet"},{"key":"key20150119112946185_ref1-bib2","doi-asserted-by":"publisher","first-page":"845","DOI":"10.1259\/bjr\/21332901","article-title":"Breast screening review: a radiologist\u2019s perspective","volume":"85","author":"Michell","year":"2012","journal-title":"Br J Radiol"},{"key":"key20150119112946185_ref1-bib3","doi-asserted-by":"publisher","first-page":"29","DOI":"10.1016\/S0009-9260(98)80030-5","article-title":"Incident round cancers: what lessons can we learn?","volume":"53","author":"Duncan","year":"1998","journal-title":"Clin Radiol"},{"key":"key20150119112946185_ref1-bib4","doi-asserted-by":"publisher","first-page":"168","DOI":"10.7326\/0003-4819-138-3-200302040-00008","article-title":"Individual and combined effects of age, breast density, and hormone replacement therapy use on the accuracy of screening mammography","volume":"138","author":"Carney","year":"2003","journal-title":"Ann Int Med"},{"key":"key20150119112946185_ref1-bib5","first-page":"1165","article-title":"Comparison of the performance of screening mammography, physical examination, and breast US and evaluation of factors that influence them: an analysis of 27,825 patient evaluations","volume":"205","author":"Kolb","year":"2002","journal-title":"Radiology"},{"key":"key20150119112946185_ref1-bib6","doi-asserted-by":"publisher","first-page":"511","DOI":"10.1148\/radiology.209.2.9807581","article-title":"Effects of age, breast density, ethnicity, and estrogen replacement therapy on screening mammographic sensitivity and cancer stage at diagnosis: review of 183,134 screening mammograms in Albuquerque, New Mexico","volume":"209","author":"Rosenberg","year":"1998","journal-title":"Radiology"},{"key":"key20150119112946185_ref1-bib7","doi-asserted-by":"publisher","first-page":"247","DOI":"10.1186\/bcr64","article-title":"Mammographic screening and mammographic patterns","volume":"2","author":"Day","year":"2000","journal-title":"Breast Cancer Res"},{"key":"key20150119112946185_ref1-bib8","doi-asserted-by":"publisher","first-page":"1081","DOI":"10.1093\/jnci\/92.13.1081","article-title":"Breast density as a predictor of mammographic detection: comparison of interval- and screen-detected cancers","volume":"92","author":"Mandelson","year":"2000","journal-title":"J Natl Canc Inst"},{"key":"key20150119112946185_ref1-bib9","doi-asserted-by":"publisher","first-page":"1219","DOI":"10.1158\/1055-9965.EPI-09-1028","article-title":"Effect of baseline breast density on breast cancer incidence, stage, mortality, and screening parameters: 25-year follow-up of a Swedish mammographic screening","volume":"19","author":"Chiu","year":"2010","journal-title":"Cancer Epidemiol Biomarkers Prev"},{"key":"key20150119112946185_ref1-bib10","doi-asserted-by":"publisher","first-page":"267","DOI":"10.1136\/jech.52.4.267","article-title":"Effect of mammographic breast density on breast cancer screening performance: a study in Nijmegen, the Netherlands","volume":"52","author":"van Gils","year":"1998","journal-title":"J Epidemiol Community Health"},{"key":"key20150119112946185_ref1-bib11","doi-asserted-by":"publisher","first-page":"1432","DOI":"10.1093\/jnci\/djh269","article-title":"Factors contributing to mammography failure in women aged 40\u201349 years","volume":"96","author":"Buist","year":"2004","journal-title":"J Natl Canc Inst"},{"key":"key20150119112946185_ref1-bib12","doi-asserted-by":"crossref","first-page":"121","DOI":"10.1054\/bjoc.2000.1151","article-title":"High risk mammographic parenchymal patterns and diet: a case\u2013control study","volume":"83","author":"Sala","year":"2000","journal-title":"Br J Cancer"},{"key":"key20150119112946185_ref1-bib13","doi-asserted-by":"publisher","first-page":"140","DOI":"10.1258\/jms.2009.009054","article-title":"Tumour size at detection according to different measures of mammographic breast density","volume":"16","author":"Nickson","year":"2009","journal-title":"J Med Screen"},{"key":"key20150119112946185_ref1-bib14","volume-title":"Cancer Reform Strategy","author":"","year":"2007"},{"key":"key20150119112946185_ref1-bib15","doi-asserted-by":"publisher","first-page":"96","DOI":"10.1258\/jms.2011.011065","article-title":"Extending the age range for breast screening in England: pilot study to assess the feasibility and acceptability of randomization","volume":"18","author":"Moser","year":"2011","journal-title":"J Med Screen"},{"key":"key20150119112946185_ref1-bib16","doi-asserted-by":"publisher","first-page":"586","DOI":"10.2214\/AJR.08.2031","article-title":"Digital breast tomosynthesis: observer performance study","volume":"193","author":"Gur","year":"2009","journal-title":"AJR Am J Roentgenol"},{"key":"key20150119112946185_ref1-bib17","doi-asserted-by":"publisher","first-page":"104","DOI":"10.1148\/radiol.12120674","article-title":"Assessing radiologist performance using combined digital mammography and breast tomosynthesis compared with digital mammography alone: results of a multicenter, multireader trial","volume":"266","author":"Rafferty","year":"2013","journal-title":"Radiology"},{"key":"key20150119112946185_ref1-bib18","doi-asserted-by":"publisher","first-page":"76","DOI":"10.1016\/j.breast.2013.11.006","article-title":"Incremental effect from integrating 3D-mammography (tomosynthesis) with 2D-mammography: increased breast cancer detection evident for screening centres in a population-based trial","volume":"23","author":"Caumo","year":"2014","journal-title":"Breast"},{"key":"key20150119112946185_ref1-bib19","doi-asserted-by":"publisher","first-page":"47","DOI":"10.1148\/radiol.12121373","article-title":"Comparison of digital mammography alone and digital mammography plus tomosynthesis in a population-based screening program","volume":"267","author":"Skaane","year":"2013","journal-title":"Radiology"},{"key":"key20150119112946185_ref1-bib20","doi-asserted-by":"publisher","first-page":"267","DOI":"10.1007\/s10549-012-1959-y","article-title":"Prospective study of breast tomosynthesis as a triage to assessment in screening","volume":"133","author":"Bernardi","year":"2012","journal-title":"Breast Cancer Res"},{"key":"key20150119112946185_ref1-bib21","doi-asserted-by":"publisher","first-page":"917","DOI":"10.1002\/pon.904","article-title":"The psychological impact of mammographic screening: a systematic review","volume":"14","author":"Brett","year":"2005","journal-title":"Psycho-oncology"},{"key":"key20150119112946185_ref1-bib22","doi-asserted-by":"publisher","first-page":"54","DOI":"10.1136\/eb-2012-100608","article-title":"Psychological consequences of false-positive screening mammograms in the UK","volume":"18","author":"Bond","year":"2013","journal-title":"Evid Based Med"},{"key":"key20150119112946185_ref1-bib23","doi-asserted-by":"publisher","first-page":"R65","DOI":"10.1088\/0031-9155\/48\/19\/R01","article-title":"Digital X-ray tomosynthesis: current state of the art and clinical potential","volume":"48","author":"Dobbins","year":"2003","journal-title":"Phys Med Biol"},{"key":"key20150119112946185_ref1-bib24","first-page":"25","article-title":"Full-field breast tomosynthesis","volume":"27","author":"Smith","year":"2005","journal-title":"Radiol Manage"},{"key":"key20150119112946185_ref1-bib25","doi-asserted-by":"publisher","first-page":"1956","DOI":"10.1118\/1.3120285","article-title":"Tomosynthesis imaging: at a translational crossroads","volume":"36","author":"Dobbins","year":"2009","journal-title":"Med Phys"},{"key":"key20150119112946185_ref1-bib26","doi-asserted-by":"publisher","first-page":"014301","DOI":"10.1118\/1.4770279","article-title":"A review of breast tomosynthesis. Part I: the image acquisition process","volume":"40","author":"Sechopoulos","year":"2013","journal-title":"Med Phys"},{"key":"key20150119112946185_ref1-bib27","doi-asserted-by":"publisher","first-page":"014302","DOI":"10.1118\/1.4770281","article-title":"A review of breast tomosynthesis. Part II: image reconstruction, processing and analysis, and advanced applications","volume":"40","author":"Sechopoulos","year":"2013","journal-title":"Med Phys"},{"key":"key20150119112946185_ref1-bib28","doi-asserted-by":"publisher","first-page":"399","DOI":"10.1148\/radiology.205.2.9356620","article-title":"Digital tomosynthesis in breast imaging","volume":"205","author":"Niklason","year":"1997","journal-title":"Radiology"},{"key":"key20150119112946185_ref1-bib29","doi-asserted-by":"publisher","first-page":"1085","DOI":"10.1016\/S1076-6332(00)80061-6","article-title":"Comparison of tomosynthesis methods used with digital mammography","volume":"7","author":"Suryanarayanan","year":"2000","journal-title":"Acad Radiol"},{"key":"key20150119112946185_ref1-bib30","doi-asserted-by":"publisher","first-page":"365","DOI":"10.1118\/1.1543934","article-title":"Tomographic mammography using a limited number of low-dose cone-beam projection images","volume":"30","author":"Wu","year":"2003","journal-title":"Med Phys"},{"key":"key20150119112946185_ref1-bib31","doi-asserted-by":"publisher","first-page":"524","DOI":"10.1258\/ar.2012.120062","article-title":"Digital breast tomosynthesis (DBT): initial experience in a clinical setting","volume":"53","author":"Skaane","year":"2012","journal-title":"Acta Radiol"},{"key":"key20150119112946185_ref1-bib32","doi-asserted-by":"publisher","first-page":"597253","DOI":"10.1155\/2013\/597253","article-title":"The adjunctive digital breast tomosynthesis in diagnosis of breast cancer","volume":"2013","author":"Yang","year":"2013","journal-title":"BioMed Res Int"},{"key":"key20150119112946185_ref1-bib33","doi-asserted-by":"publisher","first-page":"134","DOI":"10.1258\/ar.2010.100262","article-title":"Clinical experience of photon counting breast tomosynthesis: comparison with traditional mammography","volume":"52","author":"Svane","year":"2011","journal-title":"Acta Radiol"},{"key":"key20150119112946185_ref1-bib34","doi-asserted-by":"publisher","first-page":"5618","DOI":"10.1118\/1.3488899","article-title":"In-plane visibility of lesions using breast tomosynthesis and digital mammography","volume":"37","author":"Timberg","year":"2010","journal-title":"Med Phys"},{"key":"key20150119112946185_ref1-bib35","doi-asserted-by":"publisher","first-page":"240","DOI":"10.3109\/02841850903524447","article-title":"Breast tomosynthesis: accuracy of tumor measurement compared with digital mammography and ultrasonography","volume":"51","author":"Fornvik","year":"2010","journal-title":"Acta Radiol"},{"key":"key20150119112946185_ref1-bib36","doi-asserted-by":"publisher","DOI":"10.1177\/0284185113503636","article-title":"Digital breast tomosynthesis versus full-field digital mammography: comparison of the accuracy of lesion measurement and characterization using specimens","author":"Seo","year":"2013","journal-title":"Acta Radiol"},{"key":"key20150119112946185_ref1-bib37","doi-asserted-by":"publisher","first-page":"1254","DOI":"10.1016\/j.crad.2013.07.006","article-title":"Assessment of extent of breast cancer: comparison between digital breast tomosynthesis and full-field digital mammography","volume":"68","author":"Mun","year":"2013","journal-title":"Clin Radiol"},{"key":"key20150119112946185_ref1-bib38","doi-asserted-by":"publisher","first-page":"1119","DOI":"10.1007\/s11547-013-0941-z","article-title":"Accuracy of tumour size assessment in the preoperative staging of breast cancer: comparison of digital mammography, tomosynthesis, ultrasound and MRI","volume":"118","author":"Luparia","year":"2013","journal-title":"Radiol Med"},{"key":"key20150119112946185_ref1-bib39","doi-asserted-by":"publisher","first-page":"W172","DOI":"10.2214\/AJR.09.3244","article-title":"Digital breast tomosynthesis in the diagnostic environment: a subjective side-by-side review","volume":"195","author":"Hakim","year":"2010","journal-title":"AJR Am J Roentgenol"},{"key":"key20150119112946185_ref1-bib40","doi-asserted-by":"publisher","first-page":"89","DOI":"10.1148\/radiol.12120552","article-title":"Digital breast tomosynthesis versus supplemental diagnostic mammographic views for evaluation of noncalcified breast lesions","volume":"266","author":"Zuley","year":"2013","journal-title":"Radiology"},{"key":"key20150119112946185_ref1-bib41","doi-asserted-by":"publisher","first-page":"22539","DOI":"10.1007\/s00330-011-2305-1","article-title":"One-to-one comparison between digital spot compression view and digital breast tomosynthesis","author":"Tagliafico","journal-title":"Eur Radiol"},{"key":"key20150119112946185_ref1-bib42","doi-asserted-by":"publisher","first-page":"61","DOI":"10.1148\/radiol.11101763","article-title":"Digital breast tomosynthesis is comparable to mammographic spot views for mass characterization","volume":"262","author":"Noroozian","year":"2012","journal-title":"Radiology"},{"key":"key20150119112946185_ref1-bib43","doi-asserted-by":"publisher","first-page":"616","DOI":"10.2214\/AJR.07.2231","article-title":"Digital breast tomosynthesis: initial experience in 98 women with abnormal digital screening mammography","volume":"189","author":"Poplack","year":"2007","journal-title":"AJR Am J Roentgenol"},{"key":"key20150119112946185_ref1-bib44","doi-asserted-by":"publisher","first-page":"320","DOI":"10.2214\/AJR.10.4656","article-title":"Detection and classification of calcifications on digital breast tomosynthesis and 2D digital mammography: a comparison","volume":"196","author":"Spangler","year":"2011","journal-title":"AJR Am J Roentgenol"},{"key":"key20150119112946185_ref1-bib45","doi-asserted-by":"publisher","first-page":"976","DOI":"10.1016\/j.crad.2012.03.009","article-title":"A comparison of the accuracy of film-screen mammography, full-field digital mammography, and digital breast tomosynthesis","volume":"67","author":"Michell","year":"2012","journal-title":"Clin Radiol"},{"key":"key20150119112946185_ref1-bib46","doi-asserted-by":"publisher","first-page":"788","DOI":"10.1148\/radiol.11103514","article-title":"Two-view and single-view tomosynthesis versus full-field digital mammography: high-resolution X-ray imaging observer study","volume":"262","author":"Wallis","year":"2012","journal-title":"Radiology"},{"key":"key20150119112946185_ref1-bib47","doi-asserted-by":"publisher","first-page":"16","DOI":"10.1007\/s00330-009-1523-2","article-title":"Breast tomosynthesis in clinical practice: initial results","volume":"20","author":"Teertstra","year":"2010","journal-title":"Eur Radiol"},{"key":"key20150119112946185_ref1-bib48","doi-asserted-by":"publisher","first-page":"2817","DOI":"10.1007\/s00330-008-1076-9","article-title":"Breast tomosynthesis and digital mammography: a comparison of breast cancer visibility and BIRADS classification in a population of cancers with subtle mammographic findings","volume":"18","author":"Andersson","year":"2008","journal-title":"Eur Radiol"},{"key":"key20150119112946185_ref1-bib49","doi-asserted-by":"publisher","first-page":"638","DOI":"10.1111\/j.1524-4741.2011.01152.x","article-title":"Calcifications in the breast and digital breast tomosynthesis","volume":"17","author":"Kopans","year":"2011","journal-title":"Breast J"},{"key":"key20150119112946185_ref1-bib50","doi-asserted-by":"publisher","first-page":"1486","DOI":"10.1118\/1.2885366","article-title":"Automated detection of microcalcification clusters for digital breast tomosynthesis using projection data only: a preliminary study","volume":"35","author":"Reiser","year":"2008","journal-title":"Med Phys"},{"key":"key20150119112946185_ref1-bib51","doi-asserted-by":"publisher","first-page":"997","DOI":"10.1007\/s00330-012-2675-z","article-title":"Investigation of viewing procedures for interpretation of breast tomosynthesis image volumes: a detection-task study with eye tracking","volume":"23","author":"Timberg","year":"2013","journal-title":"Eur Radiol"},{"key":"key20150119112946185_ref1-bib52","doi-asserted-by":"publisher","first-page":"1976","DOI":"10.1118\/1.3116902","article-title":"Evaluation of a variable dose acquisition technique for microcalcification and mass detection in digital breast tomosynthesis","volume":"36","author":"Das","year":"2009","journal-title":"Med Phys"},{"key":"key20150119112946185_ref1-bib53","doi-asserted-by":"crossref","first-page":"65103C","DOI":"10.1117\/12.713677","article-title":"A new approach to digital breast tomosynthesis for breast cancer screening","volume":"6510","author":"Nishikawa","year":"2007","journal-title":"Proc SPIE Med Imaging"},{"key":"key20150119112946185_ref1-bib54","doi-asserted-by":"crossref","first-page":"67","DOI":"10.1007\/978-3-540-70538-3_10","volume-title":"Digital Mammography: 9th International Workshop on Digital Mammography","author":"Tingberg","year":"2008"},{"key":"key20150119112946185_ref1-bib55","doi-asserted-by":"publisher","first-page":"1019","DOI":"10.1259\/bjr\/53282892","article-title":"Breast tomosynthesis and digital mammography: a comparison of diagnostic accuracy","volume":"85","author":"Svahn","year":"2012","journal-title":"Br J Radiol"},{"key":"key20150119112946185_ref1-bib56","doi-asserted-by":"publisher","first-page":"2441","DOI":"10.1007\/s00330-013-2863-5","article-title":"Digital breast tomosynthesis versus mammography and breast ultrasound: a multireader performance study","volume":"23","author":"Thibault","year":"2013","journal-title":"Eur Radiol"},{"key":"key20150119112946185_ref1-bib57","doi-asserted-by":"publisher","first-page":"1545","DOI":"10.1007\/s00330-009-1699-5","article-title":"Digital breast tomosynthesis versus digital mammography: a clinical performance study","volume":"20","author":"Gennaro","year":"2010","journal-title":"Eur Radiol"},{"key":"key20150119112946185_ref1-bib58","doi-asserted-by":"crossref","first-page":"61","DOI":"10.1007\/978-3-540-70538-3_9","volume-title":"Digital Mammography: 9th International Workshop on Digital Mammography","author":"Smith","year":"2008"},{"key":"key20150119112946185_ref1-bib59","doi-asserted-by":"publisher","first-page":"694","DOI":"10.1148\/radiol.13130307","article-title":"Comparison of tomosynthesis plus digital mammography and digital alone for breast cancer screening","volume":"269","author":"Haas","year":"2013","journal-title":"Radiology"},{"key":"key20150119112946185_ref1-bib60","doi-asserted-by":"publisher","first-page":"1401","DOI":"10.2214\/AJR.12.9672","article-title":"Implementation of breast tomosynthesis in a routine screening practice: an observational study","volume":"200","author":"Rose","year":"2013","journal-title":"AJR Am J Roentgenol"},{"key":"key20150119112946185_ref1-bib61","doi-asserted-by":"publisher","first-page":"281","DOI":"10.1053\/j.sult.2011.03.002","article-title":"Breast tomosynthesis","volume":"32","author":"Diekmann","year":"2011","journal-title":"Semin Ultrasound CT MR"},{"key":"key20150119112946185_ref1-bib62","doi-asserted-by":"publisher","first-page":"180","DOI":"10.1093\/rpd\/ncr296","article-title":"Breast cancer screening with tomosynthesis: initial experiences","volume":"147","author":"Tingberg","year":"2011","journal-title":"Radiat Prot Dosimetry"},{"key":"key20150119112946185_ref1-bib63","doi-asserted-by":"publisher","first-page":"225","DOI":"10.1016\/j.crad.2013.01.007","article-title":"Digital tomosynthesis: a new future for breast imaging?","volume":"68","author":"Alakhras","year":"2013","journal-title":"Clin Radiol"},{"key":"key20150119112946185_ref1-bib64","doi-asserted-by":"publisher","first-page":"101","DOI":"10.1016\/j.breast.2013.01.017","article-title":"Overview of the evidence on digital breast tomosynthesis in breast cancer detection","volume":"22","author":"Houssami","year":"2013","journal-title":"Breast"},{"key":"key20150119112946185_ref1-bib65","volume-title":"Digital Breast Tomosynthesis: Overview of the Evidence and Issues for Its Use in Screening for Breast Cancer","author":"","year":"2013"},{"key":"key20150119112946185_ref1-bib66","doi-asserted-by":"publisher","first-page":"583","DOI":"10.1016\/S1470-2045(13)70134-7","article-title":"Integration of 3D digital mammography with tomosynthesis for population breast-cancer screening (STORM): a prospective comparison study","volume":"14","author":"Ciatto","year":"2013","journal-title":"Lancet Oncol"},{"key":"key20150119112946185_ref1-bib67","doi-asserted-by":"publisher","first-page":"614","DOI":"10.2214\/AJR.07.2588","article-title":"Tomosynthesis: potential clinical role in breast imaging","volume":"189","author":"Gur","year":"2007","journal-title":"AJR Am J Roentgenol"},{"key":"key20150119112946185_ref1-bib68","doi-asserted-by":"publisher","first-page":"865","DOI":"10.2214\/AJR.07.2841","article-title":"Digital breast tomosynthesis: a pilot observer study","volume":"190","author":"Good","year":"2008","journal-title":"AJR Am J Roentgenol"},{"key":"key20150119112946185_ref1-bib69","doi-asserted-by":"publisher","first-page":"587","DOI":"10.1148\/radiol.2533091517","article-title":"Mammography: yet another challenge","volume":"253","author":"Kopans","year":"2009","journal-title":"Radiology"},{"key":"key20150119112946185_ref1-bib70","doi-asserted-by":"publisher","first-page":"166","DOI":"10.1016\/j.acra.2011.10.003","article-title":"Dose reduction in digital breast tomosynthesis (DBT) screening using synthetically reconstructed projection images: an observer performance study","volume":"19","author":"Gur","year":"2012","journal-title":"Acad Radiol"},{"key":"key20150119112946185_ref1-bib71","doi-asserted-by":"publisher","first-page":"913","DOI":"10.1016\/j.jacr.2013.09.010","article-title":"Digital breast tomosynthesis and the challenges of implementing an emerging breast cancer screening technology into clinical practice","volume":"10","author":"Lee","year":"2013","journal-title":"J Am Coll Radiol"},{"key":"key20150119112946185_ref1-bib72","doi-asserted-by":"publisher","first-page":"917","DOI":"10.1016\/j.rcl.2010.06.009","article-title":"Digital mammography imaging: breast tomosynthesis and advanced applications","volume":"48","author":"Helvie","year":"2010","journal-title":"Radiol Clin North Am"},{"key":"key20150119112946185_ref1-bib73","doi-asserted-by":"publisher","first-page":"298","DOI":"10.1016\/j.acra.2011.06.011","article-title":"Breast tomosynthesis: state-of-the-art and review of the literature","volume":"18","author":"Baker","year":"2011","journal-title":"Acad Radiol"},{"key":"key20150119112946185_ref1-bib74","unstructured":"AETNA. Clinical Policy Bulletin: Mammography. URL: www.aetna.com\/cpb\/medical\/data\/500_599\/0584.html (accessed 15 December 2013)."},{"key":"key20150119112946185_ref1-bib75","volume-title":"New and Emerging Technologies for Breast Cancer Detection: Australia and New Zealand Horizon Scanning Network. Emerging Technology Bulletin","author":"Mundy","year":"2009"},{"key":"key20150119112946185_ref1-bib76","doi-asserted-by":"publisher","first-page":"1415","DOI":"10.1097\/01.AOG.0000431055.71711.dc","article-title":"9: Digital breast tomosynthesis","volume":"121","author":"","year":"2013","journal-title":"Obstet Gynecol"},{"key":"key20150119112946185_ref1-bib77","unstructured":"Oslo University Hospital. Tomosynthesis in the Oslo Breast Cancer Screening Program (DBT). URL: http:\/\/clinicaltrials.gov\/show\/NCT01248546 (accessed 4 November 2013)."},{"key":"key20150119112946185_ref1-bib78","doi-asserted-by":"publisher","first-page":"655","DOI":"10.1148\/radiol.13131391","article-title":"Two-view digital breast tomosynthesis screening with synthetically reconstructed projetion images: comparison with digital breast tomosynthesis with full-field digital mammographic images","volume":"271","author":"Skaane","year":"2014","journal-title":"Radiology"},{"key":"key20150119112946185_ref1-bib79","doi-asserted-by":"publisher","first-page":"390","DOI":"10.2214\/AJR.08.1706","article-title":"Tailored supplemental screening for breast cancer: what now and what next?","volume":"192","author":"Berg","year":"2009","journal-title":"AJR Am J Roentgenol"},{"key":"key20150119112946185_ref1-bib80","volume-title":"Digital Breast Tomosynthesis","author":"Gilbert","year":"2010"},{"key":"key20150119112946185_ref1-bib81","volume-title":"Familial Breast Cancer: Classification and Care of People at Risk of Familial Breast Cancer and Management of Breast Cancer and Related Risks in People with a Family History of Breast Cancer","author":"","year":"2013"},{"key":"key20150119112946185_ref1-bib82","doi-asserted-by":"publisher","first-page":"261","DOI":"10.1259\/bjr\/20496795","article-title":"Risk factors for induction of breast cancer by X-rays and their implications for breast screening","volume":"80","author":"Law","year":"2007","journal-title":"Br J Radiol"},{"key":"key20150119112946185_ref1-bib83","volume-title":"Review of Radiation Risk in Breast Screening","author":"Young","year":"2003"},{"key":"key20150119112946185_ref1-bib84","volume-title":"Commissioning and Routine Testing of Full Field Digital Mammography Systems","author":"Kulama","year":"2009"},{"key":"key20150119112946185_ref1-bib85","doi-asserted-by":"publisher","first-page":"624","DOI":"10.1016\/j.crad.2009.01.010","article-title":"The Royal College of Radiologists Breast Group breast imaging classification","volume":"64","author":"Maxwell","year":"2009","journal-title":"Clin Radiol"},{"key":"key20150119112946185_ref1-bib86","doi-asserted-by":"publisher","first-page":"348","DOI":"10.1148\/radiol.2461070309","article-title":"Basic physics and doubts about relationship between mammographically determined tissue density and breast cancer risk","volume":"246","author":"Kopans","year":"2008","journal-title":"Radiology"},{"key":"key20150119112946185_ref1-bib87","doi-asserted-by":"publisher","first-page":"418","DOI":"10.1158\/1055-9965.EPI-09-1059","article-title":"Screen-film mammographic density and breast cancer risk: a comparison of the volumetric standard mammogram form and the interactive threshold measurement methods","volume":"19","author":"Aitken","year":"2010","journal-title":"Cancer Epidemiol Biomarkers Prev"},{"key":"key20150119112946185_ref1-bib88","doi-asserted-by":"publisher","first-page":"204","DOI":"10.1007\/s12282-013-0456-4","article-title":"The emerging role of breast tomosynthesis","volume":"20","author":"Uematsu","year":"2013","journal-title":"Breast Cancer"},{"key":"key20150119112946185_ref1-bib89","volume-title":"Sample Size Tables for Clinical Studies","author":"Machin","year":"1997","edition":"2nd edn."},{"key":"key20150119112946185_ref1-bib90","doi-asserted-by":"publisher","first-page":"153","DOI":"10.1007\/BF02295996","article-title":"Note on the sampling error of the difference between correlated proportions or percentages","volume":"12","author":"McNemar","year":"1947","journal-title":"Psychometrika"},{"key":"key20150119112946185_ref1-bib91","doi-asserted-by":"publisher","first-page":"837","DOI":"10.2307\/2531595","article-title":"Comparing the areas under two or more correlated receiver operating characteristic curves: a nonparametric approach","volume":"44","author":"DeLong","year":"1988","journal-title":"Biometrics"},{"key":"key20150119112946185_ref1-bib92","doi-asserted-by":"publisher","DOI":"10.1117\/12.2006039","article-title":"A comparison of image interpretation times in full field digital mammography and digital breast tomosynthesis","author":"Astley","journal-title":"Proc SPIE 8637 Medical Imaging 2013: Image Perception, Observer Performance, and Technology Assessment"},{"key":"key20150119112946185_ref1-bib93","doi-asserted-by":"publisher","first-page":"33","DOI":"10.1038\/nrclinonc.2011.173","article-title":"Clinical and epidemiological issues in mammographic density","volume":"9","author":"Assi","year":"2012","journal-title":"Nat Rev Clin Oncol"},{"key":"key20150119112946185_ref1-bib94","doi-asserted-by":"publisher","first-page":"1159","DOI":"10.1158\/1055-9965.EPI-06-0034","article-title":"Breast density and parenchymal patterns as markers of breast cancer risk: a meta-analysis","volume":"15","author":"McCormack","year":"2006","journal-title":"Cancer Epidemiol Biomarkers Prev"},{"key":"key20150119112946185_ref1-bib95","doi-asserted-by":"publisher","first-page":"670","DOI":"10.1093\/jnci\/87.9.670","article-title":"Quantitative classification of mammographic densities and breast cancer risk: results from the Canadian National Breast Screening Study","volume":"87","author":"Boyd","year":"1995","journal-title":"J Natl Canc Inst"},{"key":"key20150119112946185_ref1-bib96","doi-asserted-by":"publisher","first-page":"227","DOI":"10.1056\/NEJMoa062790","article-title":"Mammographic density and the risk and detection of breast cancer","volume":"356","author":"Boyd","year":"2007","journal-title":"N Engl J Med"},{"key":"key20150119112946185_ref1-bib97","doi-asserted-by":"publisher","first-page":"1754","DOI":"10.1158\/1055-9965.EPI-09-0107","article-title":"Mammographic density and breast cancer risk: evaluation of a novel method of measuring breast tissue volumes","volume":"18","author":"Boyd","year":"2009","journal-title":"Cancer Epidemiol Biomarkers Prev"},{"key":"key20150119112946185_ref1-bib98","doi-asserted-by":"publisher","first-page":"569","DOI":"10.1016\/S1470-2045(09)70078-6","article-title":"Breast-tissue composition and other risk factors for breast cancer in young women: a cross-sectional study","volume":"10","author":"Boyd","year":"2009","journal-title":"Lancet Oncol"},{"key":"key20150119112946185_ref1-bib99","doi-asserted-by":"publisher","first-page":"223","DOI":"10.1186\/bcr2942","article-title":"Mammographic density and breast cancer risk: current understanding and future prospects","volume":"13","author":"Boyd","year":"2011","journal-title":"Breast Cancer Res"},{"key":"key20150119112946185_ref1-bib100","doi-asserted-by":"crossref","first-page":"643","DOI":"10.1093\/jnci\/djj167","article-title":"Re: Tamoxifen for the prevention of breast cancer: current status of the National Surgical Adjuvant Breast and Bowel Project P-1 study","volume":"98","author":"Cuzick","year":"2006","journal-title":"J Natl Canc Inst"},{"key":"key20150119112946185_ref1-bib101","doi-asserted-by":"publisher","first-page":"217","DOI":"10.1186\/bcr1829","article-title":"Mammographic density, breast cancer risk and risk prediction","volume":"9","author":"Vachon","year":"2007","journal-title":"Breast Cancer Res"},{"key":"key20150119112946185_ref1-bib102","first-page":"332","article-title":"Mammographic density and breast cancer in three ethnic groups","volume":"12","author":"Ursin","year":"2003","journal-title":"Cancer Epidemiol Biomarkers Prev"},{"key":"key20150119112946185_ref1-bib103","doi-asserted-by":"publisher","first-page":"1622","DOI":"10.1093\/jnci\/87.21.1622","article-title":"Mammographic features and breast cancer risk: effects with time, age, and menopause status","volume":"87","author":"Byrne","year":"1995","journal-title":"J Natl Canc Inst"},{"key":"key20150119112946185_ref1-bib104","doi-asserted-by":"publisher","first-page":"1052","DOI":"10.1158\/1055-9965.EPI-04-0717","article-title":"Mammographic features and subsequent risk of breast cancer: a comparison of qualitative and quantitative evaluations in the Guernsey prospective studies","volume":"14","author":"Torres-Mejia","year":"2005","journal-title":"Cancer Epidemiol Biomarkers Prev"},{"key":"key20150119112946185_ref1-bib105","doi-asserted-by":"publisher","first-page":"556","DOI":"10.1093\/jnci\/95.7.556","article-title":"Mammographic breast density and family history of breast cancer","volume":"95","author":"Ziv","year":"2003","journal-title":"J Natl Canc Inst"},{"key":"key20150119112946185_ref1-bib106","doi-asserted-by":"publisher","first-page":"33","DOI":"10.1001\/jama.1996.03540010035027","article-title":"Effect of age, breast density, and family history on the sensitivity of first screening mammography","volume":"276","author":"Kerlikowske","year":"1996","journal-title":"JAMA"},{"key":"key20150119112946185_ref1-bib107","doi-asserted-by":"publisher","first-page":"1856","DOI":"10.1158\/1055-9965.EPI-06-0290","article-title":"Influence of patterns of hormone replacement therapy use and mammographic density on breast cancer detection","volume":"15","author":"Chiarelli","year":"2006","journal-title":"Cancer Epidemiol Biomarkers Prev"},{"key":"key20150119112946185_ref1-bib108","doi-asserted-by":"publisher","first-page":"872","DOI":"10.1158\/1055-9965.EPI-07-0559","article-title":"Association of mammographic density with the pathology of subsequent breast cancer among postmenopausal women","volume":"17","author":"Ghosh","year":"2008","journal-title":"Cancer Epidemiol Biomarkers Prev"},{"key":"key20150119112946185_ref1-bib109","doi-asserted-by":"publisher","first-page":"662","DOI":"10.1158\/1055-9965.EPI-04-0327","article-title":"Association between mammographic breast density and breast cancer tumor characteristics","volume":"14","author":"Aiello","year":"2005","journal-title":"Cancer Epidemiol Biomarkers Prev"},{"key":"key20150119112946185_ref1-bib110","doi-asserted-by":"publisher","first-page":"1179","DOI":"10.1093\/jnci\/djr225","article-title":"Mammographic breast density and subsequent risk of breast cancer in postmenopausal women according to tumor characteristics","volume":"103","author":"Yaghjyan","year":"2011","journal-title":"J Natl Canc Inst"},{"key":"key20150119112946185_ref1-bib111","doi-asserted-by":"publisher","first-page":"157","DOI":"10.1007\/s003300050025","article-title":"Size, node status and grade of breast tumours: association with mammographic parenchymal patterns","volume":"10","author":"Sala","year":"2000","journal-title":"Eur Radiol"},{"key":"key20150119112946185_ref1-bib112","doi-asserted-by":"publisher","first-page":"42","DOI":"10.1148\/radiol.2301020589","article-title":"Invasive cancers detected after breast cancer screening yielded a negative result: relationship of mammographic density to tumor prognostic factors","volume":"230","author":"Roubidoux","year":"2004","journal-title":"Radiology"},{"key":"key20150119112946185_ref1-bib113","first-page":"807","article-title":"Outcomes of screening mammography by frequency, breast density, and postmenopausal hormone therapy","volume":"173","author":"Kerlikowske","year":"2013","journal-title":"JAMA"},{"key":"key20150119112946185_ref1-bib114","doi-asserted-by":"publisher","first-page":"315","DOI":"10.1023\/A:1007423824675","article-title":"Mammographic breast density and risk of breast cancer: masking bias or causality?","volume":"14","author":"van Gils","year":"1998","journal-title":"Eur J Epidemiol"},{"key":"key20150119112946185_ref1-bib115","doi-asserted-by":"publisher","first-page":"1672","DOI":"10.1056\/NEJMcp021804","article-title":"Clinical practice: mammographic screening for breast cancer","volume":"348","author":"Fletcher","year":"2003","journal-title":"N Engl J Med"},{"key":"key20150119112946185_ref1-bib116","doi-asserted-by":"publisher","first-page":"1021","DOI":"10.1016\/j.ejca.2010.12.002","article-title":"Evidence of the effect of adjunct ultrasound screening in women with mammography-negative dense breasts: interval breast cancers at 1 year follow-up","volume":"47","author":"Corsetti","year":"2011","journal-title":"Eur J Cancer"},{"key":"key20150119112946185_ref1-bib117","doi-asserted-by":"publisher","first-page":"1394","DOI":"10.1001\/jama.2012.388","article-title":"Detection of breast cancer with addition of annual screening ultrasound or a single screening MRI to mammography in women with elevated breast cancer risk","volume":"307","author":"Berg","year":"2012","journal-title":"JAMA"},{"key":"key20150119112946185_ref1-bib118","doi-asserted-by":"publisher","first-page":"335","DOI":"10.1186\/1471-2407-9-335","article-title":"Early detection of breast cancer: benefits and risks of supplemental breast ultrasound in asymptomatic women with mammographically dense breast tissue. A systematic review","volume":"9","author":"Nothacker","year":"2009","journal-title":"BMC Cancer"},{"key":"key20150119112946185_ref1-bib119","doi-asserted-by":"publisher","first-page":"161","DOI":"10.1007\/s12609-012-0070-z","article-title":"The impact of breast density on breast cancer risk and breast screening","volume":"4","author":"Houssami","year":"2012","journal-title":"Curr Breast Cancer Rep"},{"key":"key20150119112946185_ref1-bib120","doi-asserted-by":"crossref","unstructured":"Are You Dense, Inc. Are You Dense? Exposing the Best-Kept Secret\u00ae; 2012. URL: www.areyoudense.org (accessed 29 December 2014).","DOI":"10.4324\/9780080958989-9"},{"key":"key20150119112946185_ref1-bib121","doi-asserted-by":"publisher","first-page":"e81653","DOI":"10.1371\/journal.pone.0081653","article-title":"Agreement of mammographic measures of volumetric breast density to MRI","volume":"8","author":"Wang","year":"2013","journal-title":"PLOS ONE"},{"key":"key20150119112946185_ref1-bib122","doi-asserted-by":"publisher","first-page":"1143","DOI":"10.1016\/j.acra.2006.06.005","article-title":"Accuracy of assigned BI-RADS breast density category definitions","volume":"13","author":"Nicholson","year":"2006","journal-title":"Acad Radiol"},{"key":"key20150119112946185_ref1-bib123","doi-asserted-by":"publisher","first-page":"656","DOI":"10.1148\/radiol.2402041947","article-title":"Mammographic density measured with quantitative computer-aided method: comparison with radiologists\u2019 estimates and BI-RADS categories","volume":"240","author":"Martin","year":"2006","journal-title":"Radiology"},{"key":"key20150119112946185_ref1-bib124","doi-asserted-by":"publisher","first-page":"257","DOI":"10.2214\/ajr.180.1.1800257","article-title":"Automated assessment of the composition of breast tissue revealed on tissue-thickness-corrected mammography","volume":"180","author":"Wang","year":"2003","journal-title":"AJR Am J Roentgenol"},{"key":"key20150119112946185_ref1-bib125","doi-asserted-by":"publisher","first-page":"1587","DOI":"10.1148\/radiographics.18.6.9821201","article-title":"Analysis of mammographic density and breast cancer risk from digitized mammograms","volume":"18","author":"Byng","year":"1998","journal-title":"Radiographics"},{"key":"key20150119112946185_ref1-bib126","doi-asserted-by":"crossref","first-page":"114","DOI":"10.1007\/978-3-642-13666-5_16","volume-title":"Digital Mammography: 10th International Workshop on Digital Mammography","author":"Conant","year":"2010"},{"key":"key20150119112946185_ref1-bib127","volume-title":"Advanced Applications of Digital Mammography","author":"Yaffe","year":"2004"},{"key":"key20150119112946185_ref1-bib128","doi-asserted-by":"crossref","first-page":"33","DOI":"10.1007\/978-3-540-70538-3_5","volume-title":"Digital Mammography: 9th International Workshop on Digital Mammography","author":"Hartman","year":"2008"},{"key":"key20150119112946185_ref1-bib129","unstructured":"HTA Programme. TOMMY Trial: A Comparison of TOMosynthesis with Digital MammographY in the UK NHS Breast Screening Programme (26 August 2013). URL: www.nets.nihr.ac.uk\/projects\/hta\/0922182 (accessed 11 November 2014)."},{"key":"key20150119112946185_ref1-bib130","doi-asserted-by":"crossref","first-page":"342","DOI":"10.1007\/978-3-642-13666-5_46","volume-title":"Digital Mammography: 10th International Workshop on Digital Mammography","author":"Highnam","year":"2010"},{"key":"key20150119112946185_ref1-bib131","doi-asserted-by":"crossref","first-page":"228","DOI":"10.1007\/978-3-642-31271-7_30","volume-title":"Breast Imaging: 11th International Workshop on Digital Mammography","author":"Sergeant","year":"2012"},{"key":"key20150119112946185_ref1-bib132","doi-asserted-by":"crossref","first-page":"796603","DOI":"10.1117\/12.878758","volume-title":"Medical Imaging 2011: Image Perception, Observer Performance and Technology Assessment","author":"Makaronidis","year":"2011"},{"key":"key20150119112946185_ref1-bib133","doi-asserted-by":"publisher","first-page":"4666","DOI":"10.1002\/sim.5848","article-title":"Correcting for rater bias in scores on a continuous scale, with application to breast density","volume":"32","author":"Sperrin","year":"2013","journal-title":"Stat Med"},{"key":"key20150119112946185_ref1-bib134","doi-asserted-by":"publisher","first-page":"1148","DOI":"10.1158\/1055-9965.EPI-07-0085","article-title":"Comparison of a new and existing method of mammographic density measurement: intramethod reliability and associations with known risk factors","volume":"16","author":"McCormack","year":"2007","journal-title":"Cancer Epidemiol Biomarkers Prev"},{"key":"key20150119112946185_ref1-bib135","doi-asserted-by":"crossref","first-page":"414","DOI":"10.1007\/978-3-642-13666-5_56","volume-title":"10th International Workshop on Digital Mammography","author":"Sukha","year":"2010"},{"key":"key20150119112946185_ref1-bib136","doi-asserted-by":"publisher","first-page":"1473","DOI":"10.1158\/1055-9965.EPI-10-1150","article-title":"Volume of mammographic density and risk of breast cancer","volume":"20","author":"Shepherd","year":"2011","journal-title":"Cancer Epidemiol Biomarkers Prev"},{"key":"key20150119112946185_ref1-bib137","doi-asserted-by":"crossref","first-page":"371","DOI":"10.1093\/oxfordjournals.aje.a115343","article-title":"A method for combining matched and unmatched binary data: application to randomized, controlled trials of photocoagulation in the treatment of diabetic retinopathy","volume":"130","author":"Duffy","year":"1989","journal-title":"Am J Epidemiol"},{"key":"key20150119112946185_ref1-bib138","unstructured":"Barry-Brooks MA, Lourenco AP, Mainiero MB. Breast cancer screening pre and post-tomosynthesis: comparison of recall rate, biopsy positive predictive value and cancer detection rate. Paper presented at the Radiological Society of North America 2013 Scientific Assembly and Annual Meeting, Chicago, November 2013."},{"key":"key20150119112946185_ref1-bib139","doi-asserted-by":"publisher","first-page":"499","DOI":"10.1016\/j.rcl.2013.11.013","article-title":"Clinical implication of digital breast tomosynthesis","volume":"52","author":"Conant","year":"2014","journal-title":"Radiol Clin N Am"},{"key":"key20150119112946185_ref1-bib140","doi-asserted-by":"publisher","first-page":"2499","DOI":"10.1001\/jama.2014.6095","article-title":"Breast cancer screening using tomosynthesis in combination with digital mammography","volume":"311","author":"Friedewald","year":"2014","journal-title":"JAMA"},{"key":"key20150119112946185_ref1-bib141","doi-asserted-by":"publisher","first-page":"737","DOI":"10.2214\/AJR.10.4760","article-title":"Localized detection and classification of abnormalities on FFDM and tomosynthesis examinations rated under an FROC paradigm","volume":"196","author":"Gur","year":"2011","journal-title":"AJR Am J Roentgenol"},{"key":"key20150119112946185_ref1-bib142","doi-asserted-by":"publisher","first-page":"299","DOI":"10.2214\/AJR.13.11520","article-title":"Digital breast tomosynthesis from concept to clinical care","volume":"202","author":"Kopans","year":"2014","journal-title":"Am J Roentgenol"},{"key":"key20150119112946185_ref1-bib143","doi-asserted-by":"publisher","first-page":"664","DOI":"10.1148\/radiol.13131530","article-title":"Comparison of two dimensional synthesised mammograms versus original digital mammograms alone and in combination with tomosynthesis images","volume":"271","author":"Zuley","year":"2014","journal-title":"Radiology"},{"key":"key20150119112946185_ref1-bib144","unstructured":"Locatelli M, Tonutti M, Trianni A. First Experience with the new Generation Low-dose Digital Breast Tomosynthesis: can 2D Synthetic Image Replace Digital Mammography in Combination with Digital Breast Tomosynthesis? Paper presented at the European Congress of Radiology, Vienna, 2014."},{"key":"key20150119112946185_ref1-bib145","unstructured":"American College of Radiology. ACR statement on Breast Tomosynthesis. 2014. URL: www.acr.org\/About-Us\/Media-Center\/Press-Releases\/2014-Press-Releases\/20140722-ACR-Statement-on-Breast-Tomosynthesis (accessed 4 November 2014)."},{"key":"key20150119112946185_ref1-bib146","volume-title":"OPTIMAM 2: Optimisation of Breast Cancer Detection Using Digital X-Ray Technology 2","author":"Young"},{"key":"key20150119112946185_ref1-bib147","doi-asserted-by":"publisher","first-page":"235","DOI":"10.1080\/07357900802572110","article-title":"Prognostic models: a methodological framework and review of models for breast cancer","volume":"27","author":"Altman","year":"2009","journal-title":"Cancer Investigation"},{"key":"key20150119112946185_ref1-bib148","volume-title":"Routine Quality Control Tests for Full Field Digital Mammography Systems","author":"Cush","year":"2007"},{"key":"key20150119112946185_ref1-bib149","doi-asserted-by":"crossref","first-page":"330","DOI":"10.1007\/978-3-642-31271-7_43","volume-title":"Breast Imaging: 11th International Workshop on Digital Mammography","author":"Strudley","year":"2012"},{"key":"key20150119112946185_ref1-bib150","doi-asserted-by":"crossref","first-page":"316","DOI":"10.1007\/978-3-642-31271-7_41","volume-title":"Breast Imaging: 11th International Workshop on Digital Mammography","author":"Dance","year":"2012"},{"key":"key20150119112946185_ref1-bib151","volume-title":"Physics Tomosynthesis Quality Control Tests for the TOMMY Trial","author":"Strudley","year":"2012"},{"key":"key20150119112946185_ref1-bib152","volume-title":"Technical Performance of the Seven Hologic Dimensions Tomosynthesis Systems used in the TOMMY Trial","author":"Strudley","year":"2012"},{"key":"key20150119112946185_ref1-bib153","volume-title":"Radiographer Tomosynthesis Quality Control Tests for the TOMMY Trial","author":"Strudley","year":"2012"}],"container-title":["Health Technology Assessment"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.journalslibrary.nihr.ac.uk\/publications\/hta19040\/hta19040.xml","content-type":"unspecified","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/njl-admin.nihr.ac.uk\/document\/download\/2002104","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/www.journalslibrary.nihr.ac.uk\/publications\/hta19040\/hta19040.xml","content-type":"text\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/njl-admin.nihr.ac.uk\/document\/download\/2002687","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,8,15]],"date-time":"2023-08-15T11:35:01Z","timestamp":1692099301000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.journalslibrary.nihr.ac.uk\/hta\/hta19040\/"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2015,1]]},"references-count":153,"journal-issue":{"issue":"4","published-online":{"date-parts":[[2015,1]]}},"alternative-id":["10.3310\/hta19040"],"URL":"https:\/\/doi.org\/10.3310\/hta19040","relation":{},"ISSN":["1366-5278","2046-4924"],"issn-type":[{"value":"1366-5278","type":"print"},{"value":"2046-4924","type":"electronic"}],"subject":[],"published":{"date-parts":[[2015,1]]},"assertion":[{"value":"This content has been made freely available to all.","name":"free","label":"Free to read"}]}}