{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,9,26]],"date-time":"2026-09-26T04:51:44Z","timestamp":1790398304103,"version":"4.1.0"},"reference-count":261,"publisher":"National Institute for Health and Care Research","issue":"94","license":[{"start":{"date-parts":[[2016,12,1]],"date-time":"2016-12-01T00:00:00Z","timestamp":1480550400000},"content-version":"unspecified","delay-in-days":0,"URL":"http:\/\/www.nationalarchives.gov.uk\/doc\/non-commercial-government-licence\/non-commercial-government-licence.htm"}],"funder":[{"DOI":"10.13039\/501100000664","name":"Health Technology Assessment programme","doi-asserted-by":"publisher","award":["14\/151\/01"],"award-info":[{"award-number":["14\/151\/01"]}],"id":[{"id":"10.13039\/501100000664","id-type":"DOI","asserted-by":"publisher"}]}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Health Technol Assess"],"abstract":"<jats:sec id=\"abs1-1\"><jats:title>Background<\/jats:title><jats:p>Fibrin sealants are used in different types of surgery to prevent the accumulation of post-operative fluid (seroma) or blood (haematoma) or to arrest haemorrhage (bleeding). However, there is uncertainty around the benefits and harms of fibrin sealant use.<\/jats:p><\/jats:sec><jats:sec id=\"abs1-2\"><jats:title>Objectives<\/jats:title><jats:p>To systematically review the evidence on the benefits and harms of fibrin sealants in non-emergency surgery in adults.<\/jats:p><\/jats:sec><jats:sec id=\"abs1-3\"><jats:title>Data sources<\/jats:title><jats:p>Electronic databases [MEDLINE, EMBASE and The Cochrane Library (including the Cochrane Database of Systematic Reviews, the Database of Abstracts of Reviews of Effects, the Health Technology Assessment database and the Cochrane Central Register of Controlled Trials)] were searched from inception to May 2015. The websites of regulatory bodies (the Medicines and Healthcare products Regulatory Agency, the European Medicines Agency and the Food and Drug Administration) were also searched to identify evidence of harms.<\/jats:p><\/jats:sec><jats:sec id=\"abs1-4\"><jats:title>Review methods<\/jats:title><jats:p>This review included randomised controlled trials (RCTs) and observational studies using any type of fibrin sealant compared with standard care in non-emergency surgery in adults. The primary outcome was risk of developing seroma and haematoma. Only RCTs were used to inform clinical effectiveness and both RCTs and observational studies were used for the assessment of harms related to the use of fibrin sealant. Two reviewers independently screened all titles and abstracts to identify potentially relevant studies. Data extraction was undertaken by one reviewer and validated by a second. The quality of included studies was assessed independently by two reviewers using the Cochrane Collaboration risk-of-bias tool for RCTs and the Centre for Reviews and Dissemination guidance for adverse events for observational studies. A fixed-effects model was used for meta-analysis.<\/jats:p><\/jats:sec><jats:sec id=\"abs1-5\"><jats:title>Results<\/jats:title><jats:p>We included 186 RCTs and eight observational studies across 14 surgical specialties and five reports from the regulatory bodies. Most RCTs were judged to be at an unclear risk of bias. Adverse events were inappropriately reported in observational studies. Meta-analysis across non-emergency surgical specialties did not show a statistically significant difference in the risk of seroma for fibrin sealants versus standard care in 32 RCTs analysed [<jats:italic>n<\/jats:italic>\u2009=\u20093472, odds ratio (OR) 0.84, 95% confidence interval (CI) 0.68 to 1.04;<jats:italic>p<\/jats:italic>\u2009=\u20090.13;<jats:italic>I<\/jats:italic><jats:sup>2<\/jats:sup>\u2009=\u200912.7%], but a statistically significant benefit was found on haematoma development in 24 RCTs (<jats:italic>n<\/jats:italic>\u2009=\u20092403, OR 0.62, 95% CI 0.44 to 0.86;<jats:italic>p<\/jats:italic>\u2009=\u20090.01;<jats:italic>I<\/jats:italic><jats:sup>2<\/jats:sup>\u2009=\u20090%). Adverse events related to fibrin sealant use were reported in 10 RCTs and eight observational studies across surgical specialties, and 22 RCTs explicitly stated that there were no adverse events. One RCT reported a single death but no other study reported mortality or any serious adverse events. Five regulatory body reports noted death from air emboli associated with fibrin sprays.<\/jats:p><\/jats:sec><jats:sec id=\"abs1-6\"><jats:title>Limitations<\/jats:title><jats:p>It was not possible to provide a detailed evaluation of individual RCTs in their specific contexts because of the limited resources that were available for this research. In addition, the number of RCTs that were identified made it impractical to conduct independent data extraction by two reviewers in the time available.<\/jats:p><\/jats:sec><jats:sec id=\"abs1-7\"><jats:title>Conclusions<\/jats:title><jats:p>The effectiveness of fibrin sealants does not appear to vary according to surgical procedures with regard to reducing the risk of seroma or haematoma. Surgeons should note the potential risk of gas embolism if spray application of fibrin sealants is used and not to exceed the recommended pressure and spraying distance. Future research should be carried out in surgery specialties for which only limited data were found, including neurological, gynaecological, oral and maxillofacial, urology, colorectal and orthopaedics surgery (for any outcome); breast surgery and upper gastrointestinal (development of haematoma); and cardiothoracic heart or lung surgery (reoperation rates). In addition, studies need to use adequate sample sizes, to blind participants and outcome assessors, and to follow reporting guidelines.<\/jats:p><\/jats:sec><jats:sec id=\"abs1-8\"><jats:title>Study registration<\/jats:title><jats:p>This study is registered as PROSPERO CRD42015020710.<\/jats:p><\/jats:sec><jats:sec id=\"abs1-9\"><jats:title>Funding<\/jats:title><jats:p>The National Institute for Health Research Health Technology Assessment programme.<\/jats:p><\/jats:sec>","DOI":"10.3310\/hta20940","type":"journal-article","created":{"date-parts":[[2017,1,4]],"date-time":"2017-01-04T16:00:14Z","timestamp":1483545614000},"page":"1-224","update-policy":"https:\/\/doi.org\/10.3310\/crossmarkpolicy","source":"Crossref","is-referenced-by-count":39,"title":["The use of fibrin sealant during non-emergency surgery: a systematic review of evidence of benefits and harms"],"prefix":"10.3310","volume":"20","author":[{"given":"Steven J","family":"Edwards","sequence":"first","affiliation":[{"name":"BMJ Technology Assessment Group, London, UK"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Fay","family":"Crawford","sequence":"additional","affiliation":[{"name":"BMJ Technology Assessment Group, London, UK"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Michelle Helena","family":"van Velthoven","sequence":"additional","affiliation":[{"name":"BMJ Technology Assessment Group, London, UK"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Andrea","family":"Berardi","sequence":"additional","affiliation":[{"name":"BMJ Technology Assessment Group, London, UK"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"George","family":"Osei-Assibey","sequence":"additional","affiliation":[{"name":"BMJ Technology Assessment Group, London, UK"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Mariana","family":"Bacelar","sequence":"additional","affiliation":[{"name":"BMJ Technology Assessment Group, London, UK"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Fatima","family":"Salih","sequence":"additional","affiliation":[{"name":"BMJ Technology Assessment Group, London, UK"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Victoria","family":"Wakefield","sequence":"additional","affiliation":[{"name":"BMJ Technology Assessment Group, London, UK"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"6221","published-online":{"date-parts":[[2016,12]]},"reference":[{"key":"key20161223072506546_ref1-bib1","doi-asserted-by":"publisher","first-page":"711","DOI":"10.1016\/S0748-7983(03)00096-9","article-title":"Seroma following breast cancer surgery","volume":"29","author":"Pogson","year":"2003","journal-title":"Eur J Surg Oncol"},{"key":"key20161223072506546_ref1-bib2","first-page":"247","article-title":"The use of fibrin sealant after total thyroidectomy for benign disease obviates the need for routine drainage. Results of a randomized controlled trial","volume":"15","author":"S\u00f6zen","year":"2011","journal-title":"Hippokratia"},{"key":"key20161223072506546_ref1-bib3","doi-asserted-by":"publisher","first-page":"654","DOI":"10.1177\/0194599812449315","article-title":"Efficacy of fibrin sealant for drainage reduction in total thyroidectomy with bilateral central neck dissection","volume":"147","author":"Kim","year":"2012","journal-title":"Otolaryngol Head Neck Surg"},{"key":"key20161223072506546_ref1-bib4","first-page":"1248","article-title":"Prospective study of using fibrin glue to prevent leak from esophagogastric anastomosis","volume":"25","author":"Hsu","year":"1992","journal-title":"J Surg Assoc"},{"key":"key20161223072506546_ref1-bib5","doi-asserted-by":"publisher","first-page":"221","DOI":"10.1111\/j.1445-2197.2011.05752.x","article-title":"Sticking to the facts: a systematic review of fibrin glue for pilonidal disease","volume":"82","author":"Handmer","year":"2012","journal-title":"ANZ J Surg"},{"key":"key20161223072506546_ref1-bib6","doi-asserted-by":"publisher","first-page":"CD009621","DOI":"10.1002\/14651858.cd009621","article-title":"Fibrin sealants for the prevention of postoperative pancreatic fistula following pancreatic surgery","volume":"2","author":"Cheng","year":"2012","journal-title":"Cochrane Database Syst Rev"},{"key":"key20161223072506546_ref1-bib7","doi-asserted-by":"publisher","first-page":"7","DOI":"10.1159\/000191284","article-title":"Use of sealants in pancreatic surgery: critical appraisal of the literature","volume":"26","author":"Fingerhut","year":"2009","journal-title":"Dig Surg"},{"key":"key20161223072506546_ref1-bib8","doi-asserted-by":"publisher","first-page":"494","DOI":"10.1007\/s002689900423","article-title":"Fibrin glue sandwich prevents pancreatic fistula following distal pancreatectomy","volume":"22","author":"Ohwada","year":"1998","journal-title":"World J Surg"},{"key":"key20161223072506546_ref1-bib9","doi-asserted-by":"publisher","first-page":"361","DOI":"10.1007\/s10029-011-0809-x","article-title":"Systematic review of the use of fibrin sealant in abdominal-wall repair surgery","volume":"15","author":"Morales-Conde","year":"2011","journal-title":"Hernia"},{"key":"key20161223072506546_ref1-bib10","doi-asserted-by":"publisher","first-page":"11","DOI":"10.3109\/02688697.2014.948808","article-title":"A multicentre, prospective, randomized, controlled study to evaluate the use of a fibrin sealant as an adjunct to sutured dural repair","volume":"29","author":"Green","year":"2015","journal-title":"Br J Neurosurg"},{"key":"key20161223072506546_ref1-bib11","doi-asserted-by":"publisher","first-page":"179","DOI":"10.1016\/S0268-960X(02)00062-0","article-title":"The management of perioperative bleeding","volume":"17","author":"Koh","year":"2003","journal-title":"Blood Rev"},{"key":"key20161223072506546_ref1-bib12","doi-asserted-by":"publisher","first-page":"CD005355","DOI":"10.1002\/14651858.cd005355.pub4","article-title":"Interventions to reduce haemorrhage during myomectomy for fibroids","volume":"11","author":"Kongnyuy","year":"2011","journal-title":"Cochrane Database Syst Rev"},{"key":"key20161223072506546_ref1-bib13","doi-asserted-by":"publisher","first-page":"95","DOI":"10.1016\/j.ijsu.2013.11.011","article-title":"Effect of fibrin sealant on blood loss following total knee arthroplasty: a systematic review and meta-analysis","volume":"12","author":"Liu","year":"2014","journal-title":"Int J Surg"},{"key":"key20161223072506546_ref1-bib14","doi-asserted-by":"publisher","first-page":"1580","DOI":"10.2106\/00004623-199911000-00010","article-title":"The use of fibrin tissue adhesive to reduce blood loss and the need for blood transfusion after total knee arthroplasty. A prospective, randomized, multicenter study","volume":"81","author":"Levy","year":"1999","journal-title":"J Bone Joint Surg Am"},{"key":"key20161223072506546_ref1-bib15","doi-asserted-by":"publisher","first-page":"378","DOI":"10.1001\/archsurg.1990.01410150100018","article-title":"Axillary lymphadenectomy. A prospective, randomized trial of 13 factors influencing drainage, including early or delayed arm mobilization","volume":"125","author":"Petrek","year":"1990","journal-title":"Arch Surg"},{"key":"key20161223072506546_ref1-bib16","first-page":"437","article-title":"Axillary versus combined axillary and pectoral drainage after modified radical mastectomy","volume":"175","author":"Terrell","year":"1992","journal-title":"Surg Gynecol Obstet"},{"key":"key20161223072506546_ref1-bib17","doi-asserted-by":"publisher","first-page":"127","DOI":"10.4172\/plastic-surgery.1000624","article-title":"Postoperative seroma formation after abdominoplasty with placement of continuous infusion local anesthetic pain pump","volume":"17","author":"Smith","year":"2009","journal-title":"Can J Plast Surg"},{"key":"key20161223072506546_ref1-bib18","first-page":"39","article-title":"Repair of incisional hernias","volume":"46","author":"Khaira","year":"2001","journal-title":"J R Coll Surg Edinb"},{"key":"key20161223072506546_ref1-bib19","doi-asserted-by":"publisher","first-page":"8","DOI":"10.1016\/j.surg.2005.05.001","article-title":"Postoperative pancreatic fistula: an international study group (ISGPF) definition","volume":"138","author":"Bassi","year":"2005","journal-title":"Surgery"},{"key":"key20161223072506546_ref1-bib20","doi-asserted-by":"publisher","first-page":"CD008914","DOI":"10.1002\/14651858.cd008914.pub2","article-title":"Stents for the prevention of pancreatic fistula following pancreaticoduodenectomy","volume":"6","author":"Dong","year":"2013","journal-title":"Cochrane Database Syst Rev"},{"key":"key20161223072506546_ref1-bib21","doi-asserted-by":"publisher","first-page":"CD008370","DOI":"10.1002\/14651858.cd008370","article-title":"Somatostatin analogues for pancreatic surgery","volume":"2","author":"Gurusamy","year":"2010","journal-title":"Cochrane Database Syst Rev"},{"key":"key20161223072506546_ref1-bib22","doi-asserted-by":"publisher","first-page":"1059","DOI":"10.1002\/bjs.5107","article-title":"Meta-analysis of the value of somatostatin and its analogues in reducing complications associated with pancreatic surgery","volume":"92","author":"Connor","year":"2005","journal-title":"Br J Surg"},{"key":"key20161223072506546_ref1-bib23","doi-asserted-by":"publisher","first-page":"20","DOI":"10.1016\/j.surg.2007.06.025","article-title":"Financial and clinical outcomes associated with surgical bleeding complications","volume":"142","author":"Shander","year":"2007","journal-title":"Surgery"},{"key":"key20161223072506546_ref1-bib24","doi-asserted-by":"publisher","first-page":"1145","DOI":"10.1097\/00005650-199511000-00007","article-title":"Variation in the use of red blood cell transfusions. A study of four common medical and surgical conditions","volume":"33","author":"Hasley","year":"1995","journal-title":"Med Care"},{"key":"key20161223072506546_ref1-bib25","first-page":"9","article-title":"Review of the clinical practice literature on allogeneic red blood cell transfusion","volume":"156","author":"Hebert","year":"1997","journal-title":"CMAJ"},{"key":"key20161223072506546_ref1-bib26","doi-asserted-by":"publisher","first-page":"812","DOI":"10.1016\/j.transproceed.2006.01.047","article-title":"Pathophysiology of bleeding in surgery","volume":"38","author":"Marietta","year":"2006","journal-title":"Transplant Proc"},{"key":"key20161223072506546_ref1-bib27","doi-asserted-by":"publisher","first-page":"R76","DOI":"10.1186\/cc12685","article-title":"Management of bleeding and coagulopathy following major trauma: an updated European guideline","volume":"17","author":"Spahn","year":"2013","journal-title":"Crit Care"},{"key":"key20161223072506546_ref1-bib28","doi-asserted-by":"publisher","first-page":"1184","DOI":"10.1007\/s11605-009-0866-y","article-title":"Stents, glue, etc.: is anything proven to help prevent pancreatic leaks\/fistulae?","volume":"13","author":"Schulick","year":"2009","journal-title":"J Gastrointest Surg"},{"key":"key20161223072506546_ref1-bib29","doi-asserted-by":"publisher","first-page":"171","DOI":"10.1016\/j.amjsurg.2006.10.010","article-title":"Pancreaticojejunostomy versus pancreaticogastrostomy: systematic review and meta-analysis","volume":"193","author":"Wente","year":"2007","journal-title":"Am J Surg"},{"key":"key20161223072506546_ref1-bib30","doi-asserted-by":"crossref","first-page":"9","DOI":"10.1213\/00000539-199801000-00003","article-title":"Does acute normovolemic hemodilution reduce perioperative allogeneic transfusion? A meta-analysis. The International Study of Perioperative Transfusion","volume":"86","author":"Bryson","year":"1998","journal-title":"Anesth Analg"},{"key":"key20161223072506546_ref1-bib31","doi-asserted-by":"publisher","first-page":"610","DOI":"10.1001\/archinte.158.6.610","article-title":"Preoperative autologous donation decreases allogeneic transfusion but increases exposure to all red blood cell transfusion: results of a meta-analysis. International Study of Perioperative Transfusion (ISPOT) Investigators","volume":"158","author":"Forgie","year":"1998","journal-title":"Arch Intern Med"},{"key":"key20161223072506546_ref1-bib32","doi-asserted-by":"publisher","first-page":"861","DOI":"10.1213\/00000539-199910000-00009","article-title":"A meta-analysis of the effectiveness of cell salvage to minimize perioperative allogeneic blood transfusion in cardiac and orthopedic surgery. International Study of Perioperative Transfusion (ISPOT) Investigators","volume":"89","author":"Hu\u00ebt","year":"1999","journal-title":"Anesth Analg"},{"key":"key20161223072506546_ref1-bib33","doi-asserted-by":"publisher","first-page":"1258","DOI":"10.1213\/00000539-199712000-00014","article-title":"Drugs to minimize perioperative blood loss in cardiac surgery: meta-analyses using perioperative blood transfusion as the outcome. The International Study of Peri-operative Transfusion (ISPOT) Investigators","volume":"85","author":"Laupacis","year":"1997","journal-title":"Anesth Analg"},{"key":"key20161223072506546_ref1-bib34","doi-asserted-by":"publisher","first-page":"309","DOI":"10.1046\/j.1365-3148.1998.00171.x","article-title":"Erythropoietin to minimize perioperative blood transfusion: a systematic review of randomized trials. The International Study of Peri-operative Transfusion (ISPOT) Investigators","volume":"8","author":"Laupacis","year":"1998","journal-title":"Transfus Med"},{"key":"key20161223072506546_ref1-bib35","doi-asserted-by":"publisher","first-page":"CD001886","DOI":"10.1002\/14651858.cd001886.pub3","article-title":"Anti-fibrinolytic use for minimising perioperative allogeneic blood transfusion","volume":"1","author":"Henry","year":"2011","journal-title":"Cochrane Database Syst Rev"},{"key":"key20161223072506546_ref1-bib36","volume-title":"Fibrinogen-Containing Solutions for Sealant Authorised for Administration by Spray Application","author":"EMA","year":"2012"},{"key":"key20161223072506546_ref1-bib37","volume-title":"Sprayable Fibrin Sealants (Evicel, Tisseel and Artiss): Updated Guidance","author":"MHRA","year":"2013"},{"key":"key20161223072506546_ref1-bib38","doi-asserted-by":"publisher","first-page":"CD004171","DOI":"10.1002\/14651858.cd004171","article-title":"Fibrin sealant use for minimising peri-operative allogeneic blood transfusion","volume":"2","author":"Carless","year":"2003","journal-title":"Cochrane Database Syst Rev"},{"key":"key20161223072506546_ref1-bib39","volume-title":"Risk of Life Threatening Air or Gas Embolism with the Use of Spray Devices Employing Pressure Regulator to Administer Fibrin Sealants (Baxter Health Care Corporation)","author":"Food and Drugs Administration","year":"2009"},{"key":"key20161223072506546_ref1-bib40","doi-asserted-by":"publisher","first-page":"727","DOI":"10.1016\/S1010-7940(96)80332-0","article-title":"Controlled clinical studies of fibrin sealant in cardiothoracic surgery \u2013 a review","volume":"10","author":"Kjaergard","year":"1996","journal-title":"Eur J Cardiothorac Surg"},{"key":"key20161223072506546_ref1-bib41","doi-asserted-by":"publisher","first-page":"657","DOI":"10.1093\/ejcts\/ezr083","article-title":"Adverse effects of fibrin sealants in thoracic surgery: the safety of a new fibrin sealant: multicentre, randomized, controlled, clinical trial","volume":"41","author":"Cardillo","year":"2012","journal-title":"Eur J Cardiothorac Surg"},{"key":"key20161223072506546_ref1-bib42","doi-asserted-by":"publisher","first-page":"1065","DOI":"10.1016\/j.spinee.2010.09.017","article-title":"Dural repair with four spinal sealants: focused review of the manufacturers\u2019 inserts and the current literature","volume":"10","author":"Epstein","year":"2010","journal-title":"Spine J"},{"key":"key20161223072506546_ref1-bib43","volume-title":"Systematic Reviews: Centre for Reviews and Dissemination (CRD) Guidance for Undertaking Systematic Reviews in Health Care","author":"CRD","year":"2010"},{"key":"key20161223072506546_ref1-bib44","volume-title":"Cochrane Handbook Version 5.1.0.","author":"Higgins","year":"2011"},{"key":"key20161223072506546_ref1-bib45","volume-title":"The Use of Fibrin Sealants During Non-Emergency Surgery: A Systematic Review of the Evidence of Benefits and Harms","author":"Crawford","year":"2015"},{"key":"key20161223072506546_ref1-bib46","doi-asserted-by":"publisher","first-page":"b2535","DOI":"10.1136\/bmj.b2535","article-title":"Preferred Reporting Items for Systematic Reviews and Meta-Analyses: the PRISMA statement","volume":"339","author":"Moher","year":"2009","journal-title":"BMJ"},{"key":"key20161223072506546_ref1-bib47","doi-asserted-by":"publisher","first-page":"f7668","DOI":"10.1136\/bmj.f7668","article-title":"Quality of reporting in systematic reviews of adverse events: systematic review","volume":"348","author":"Zorzela","year":"2014","journal-title":"BMJ"},{"key":"key20161223072506546_ref1-bib48","doi-asserted-by":"publisher","first-page":"32","DOI":"10.1186\/1471-2288-7-32","article-title":"Systematic reviews of adverse effects: framework for a structured approach","volume":"7","author":"Loke","year":"2007","journal-title":"BMC Med Res Methodol"},{"key":"key20161223072506546_ref1-bib49","doi-asserted-by":"publisher","first-page":"19","DOI":"10.1186\/1471-2288-4-19","article-title":"Assessing harmful effects in systematic reviews","volume":"4","author":"McIntosh","year":"2004","journal-title":"BMC Med Res Methodol"},{"key":"key20161223072506546_ref1-bib50","volume-title":"Intention-to-treat Issues for Dichotomous Data","author":"Higgins","year":"2011"},{"key":"key20161223072506546_ref1-bib51","volume-title":"The Newcastle-Ottawa Scale (NOS) for Assessing the Quality of Nonrandomised Studies in Meta-Analyses","author":"Wells","year":"2014"},{"key":"key20161223072506546_ref1-bib52","doi-asserted-by":"publisher","first-page":"377","DOI":"10.1136\/jech.52.6.377","article-title":"The feasibility of creating a checklist for the assessment of the methodological quality both of randomised and non-randomised studies of health care interventions","volume":"52","author":"Downs","year":"1998","journal-title":"J Epidemiol Community Health"},{"key":"key20161223072506546_ref1-bib53","doi-asserted-by":"publisher","first-page":"629","DOI":"10.1136\/bmj.315.7109.629","article-title":"Bias in meta-analysis detected by a simple, graphical test","volume":"315","author":"Egger","year":"1997","journal-title":"BMJ"},{"key":"key20161223072506546_ref1-bib54","first-page":"719","article-title":"Statistical aspects of the analysis of data from retrospective studies of disease","volume":"22","author":"Mantel","year":"1959","journal-title":"J Natl Cancer Inst"},{"key":"key20161223072506546_ref1-bib55","doi-asserted-by":"publisher","first-page":"177","DOI":"10.1016\/0197-2456(86)90046-2","article-title":"Meta-analysis in clinical trials","volume":"7","author":"DerSimonian","year":"1986","journal-title":"Control Clin Trials"},{"key":"key20161223072506546_ref1-bib56","doi-asserted-by":"publisher","first-page":"557","DOI":"10.1136\/bmj.327.7414.557","article-title":"Measuring inconsistency in meta-analyses","volume":"327","author":"Higgins","year":"2003","journal-title":"BMJ"},{"key":"key20161223072506546_ref1-bib57","doi-asserted-by":"publisher","first-page":"1559","DOI":"10.1002\/sim.1187","article-title":"How should meta-regression analyses be undertaken and interpreted?","volume":"21","author":"Thompson","year":"2002","journal-title":"Stat Med"},{"key":"key20161223072506546_ref1-bib58","volume-title":"Surgical Specialties","author":"Royal College of Surgeons"},{"key":"key20161223072506546_ref1-bib59","doi-asserted-by":"publisher","first-page":"147","DOI":"10.1186\/1471-2369-13-147","article-title":"Safety and hemostatic efficacy of fibrin pad in partial nephrectomy: results of an open-label phase I and a randomized, standard-of-care-controlled phase I\/II study","volume":"13","author":"Nativ","year":"2012","journal-title":"BMC Nephrol"},{"key":"key20161223072506546_ref1-bib60","doi-asserted-by":"publisher","first-page":"1338","DOI":"10.1002\/bjs.9877","article-title":"Multicentre randomized clinical trial to investigate the cost-effectiveness of an allogeneic single-donor fibrin sealant after coronary artery bypass grafting (FIBER Study)","volume":"102","author":"Tavilla","year":"2015","journal-title":"Br J Surg"},{"key":"key20161223072506546_ref1-bib61","doi-asserted-by":"publisher","first-page":"112","DOI":"10.1002\/bjs.1800830135","article-title":"Randomized trial of fibrin tissue glue for low output enterocutaneous fistula","volume":"83","author":"Hwang","year":"1996","journal-title":"Br J Surg"},{"key":"key20161223072506546_ref1-bib62","doi-asserted-by":"publisher","first-page":"2492","DOI":"10.1007\/s00464-008-9885-0","article-title":"The use of fibrin sealant to prevent major complications following laparoscopic gastric bypass: results of a multicenter, randomized trial","volume":"22","author":"Silecchia","year":"2008","journal-title":"Surg Endosc"},{"key":"key20161223072506546_ref1-bib63","doi-asserted-by":"publisher","first-page":"40","DOI":"10.1002\/bjs.1800830111","article-title":"Randomized trial of fibrin glue to seal mechanical oesophagojejunal anastomosis","volume":"83","author":"Fernandez Fernandez","year":"1996","journal-title":"Br J Surg"},{"key":"key20161223072506546_ref1-bib64","doi-asserted-by":"publisher","first-page":"1171","DOI":"10.1007\/s12013-014-0326-5","article-title":"Fibrin-sealant-delivered cisplatin chemotherapy versus cisplatin hyperthermic intraperitoneal perfusion chemotherapy for locally advanced gastric cancer without peritoneal metastases: a randomized phase-II clinical trial with a 40-month follow-up","volume":"71","author":"Huang","year":"2015","journal-title":"Cell Biochem Biophys"},{"key":"key20161223072506546_ref1-bib65","doi-asserted-by":"publisher","first-page":"837","DOI":"10.1007\/s00423-014-1227-1","article-title":"Hemostatic efficacy of latest-generation fibrin sealant after hepatic resection: a randomized controlled clinical study","volume":"399","author":"Bektas","year":"2014","journal-title":"Langenbecks Arch Surg"},{"key":"key20161223072506546_ref1-bib66","doi-asserted-by":"publisher","first-page":"229","DOI":"10.1097\/SLA.0b013e3182602819","article-title":"Fibrin sealant for prevention of resection surface-related complications after liver resection: a randomized controlled trial","volume":"256","author":"de Boer","year":"2012","journal-title":"Ann Surg"},{"key":"key20161223072506546_ref1-bib67","doi-asserted-by":"publisher","first-page":"1200","DOI":"10.1001\/archsurg.135.10.1200","article-title":"Effective control of hepatic bleeding with a novel collagen-based composite combined with autologous plasma: results of a randomized controlled trial","volume":"135","author":"Chapman","year":"2000","journal-title":"Arch Surg"},{"key":"key20161223072506546_ref1-bib68","first-page":"135","article-title":"Prevention of pleural effusion after hepatectomy using fibrin sealant","volume":"79","author":"Uetsuji","year":"1994","journal-title":"Int Surg"},{"key":"key20161223072506546_ref1-bib69","first-page":"19","article-title":"The use of fibrin adhesive for hemostasis after liver resection","volume":"1","author":"Liu","year":"1993","journal-title":"Zhonghua yi xue za zhi"},{"key":"key20161223072506546_ref1-bib70","first-page":"221","article-title":"Fibrin glue effectiveness and tolerance after elective liver resection: a randomized trial","volume":"43","author":"Noun","year":"1996","journal-title":"Hepatogastroenterology"},{"key":"key20161223072506546_ref1-bib71","doi-asserted-by":"publisher","first-page":"536","DOI":"10.1097\/01.sla.0000245846.37046.57","article-title":"Application of fibrin glue sealant after hepatectomy does not seem justified: results of a randomized study in 300 patients","volume":"245","author":"Figueras","year":"2007","journal-title":"Ann Surg"},{"key":"key20161223072506546_ref1-bib72","doi-asserted-by":"publisher","first-page":"48","DOI":"10.1016\/j.surg.2010.02.008","article-title":"Hemostatic efficacy of TachoSil in liver resection compared with argon beam coagulator treatment: an open, randomized, prospective, multicenter, parallel-group trial","volume":"149","author":"Fischer","year":"2011","journal-title":"Surgery"},{"key":"key20161223072506546_ref1-bib73","doi-asserted-by":"publisher","first-page":"114","DOI":"10.1007\/s00423-005-0543-x","article-title":"Effectiveness of a new carrier-bound fibrin sealant versus argon beamer as haemostatic agent during liver resection: a randomised prospective trial","volume":"390","author":"Frilling","year":"2005","journal-title":"Langenbecks Arch Surg"},{"key":"key20161223072506546_ref1-bib74","doi-asserted-by":"publisher","first-page":"587608","DOI":"10.1155\/2013\/587608","article-title":"A randomized clinical trial comparing the effect of different haemostatic agents for haemostasis of the liver after hepatic resection","volume":"2013","author":"Kakaei","year":"2013","journal-title":"HPB Surg"},{"key":"key20161223072506546_ref1-bib75","doi-asserted-by":"publisher","first-page":"966","DOI":"10.1007\/BF02067005","article-title":"Comparison of topical hemostatic agents in elective hepatic resection: a clinical prospective randomized trial","volume":"16","author":"Kohno","year":"1992","journal-title":"World J Surg"},{"key":"key20161223072506546_ref1-bib76","doi-asserted-by":"publisher","first-page":"725","DOI":"10.1007\/s00423-014-1203-9","article-title":"Randomized controlled multicenter trial on the effectiveness of the collagen hemostat Sangustop\u00ae compared with a carrier-bound fibrin sealant during liver resection (ESSCALIVER study, NCT00918619)","volume":"399","author":"Moench","year":"2014","journal-title":"Langenbecks Arch Surg"},{"key":"key20161223072506546_ref1-bib77","doi-asserted-by":"publisher","first-page":"1148","DOI":"10.1001\/archsurg.139.11.1148","article-title":"Comparison of a new fibrin sealant with standard topical hemostatic agents","volume":"139","author":"Schwartz","year":"2004","journal-title":"Arch Surg"},{"key":"key20161223072506546_ref1-bib78","doi-asserted-by":"publisher","first-page":"5851","DOI":"10.3748\/wjg.15.5851","article-title":"Effect of implanting fibrin sealant with ropivacaine on pain after laparoscopic cholecystectomy","volume":"15","author":"Fu","year":"2009","journal-title":"World J Gastroenterol"},{"key":"key20161223072506546_ref1-bib79","doi-asserted-by":"publisher","first-page":"825","DOI":"10.1097\/SLA.0b013e3181d3548c","article-title":"Platelet-rich fibrin versus albumin in surgical wound repair: a randomized trial with paired design","volume":"251","author":"Danielsen","year":"2010","journal-title":"Ann Surg"},{"key":"key20161223072506546_ref1-bib80","first-page":"177","article-title":"Randomized trial of fibrin adhesive for reduction of drained secretion after elective cholecystectomy","volume":"155","author":"Dimo","year":"1989","journal-title":"Acta Chir Scand"},{"key":"key20161223072506546_ref1-bib81","doi-asserted-by":"publisher","first-page":"102","DOI":"10.1007\/s11605-012-1963-x","article-title":"A dual-institution randomized controlled trial of remnant closure after distal pancreatectomy: does the addition of a falciform patch and fibrin glue improve outcomes?","volume":"17","author":"Carter","year":"2013","journal-title":"J Gastrointest Surg"},{"key":"key20161223072506546_ref1-bib82","doi-asserted-by":"publisher","first-page":"952","DOI":"10.1001\/archsurg.1995.01430090038015","article-title":"Fibrin glue sealing for the prevention of pancreatic fistulas following distal pancreatectomy","volume":"130","author":"Suzuki","year":"1995","journal-title":"Arch Surg"},{"key":"key20161223072506546_ref1-bib83","doi-asserted-by":"publisher","first-page":"766","DOI":"10.1016\/j.gassur.2004.06.011","article-title":"Does fibrin glue sealant decrease the rate of pancreatic fistula after pancreaticoduodenectomy? Results of a prospective randomized trial","volume":"8","author":"Lillemoe","year":"2004","journal-title":"J Gastrointest Surg"},{"key":"key20161223072506546_ref1-bib84","doi-asserted-by":"publisher","first-page":"853","DOI":"10.1097\/SLA.0b013e318272dec0","article-title":"Efficacy of an absorbable fibrin sealant patch (TachoSil) after distal pancreatectomy: a multicenter, randomized, controlled trial","volume":"256","author":"Montorsi","year":"2012","journal-title":"Ann Surg"},{"key":"key20161223072506546_ref1-bib85","doi-asserted-by":"publisher","first-page":"57","DOI":"10.1097\/00000658-200301000-00009","article-title":"Temporary fibrin glue occlusion of the main pancreatic duct in the prevention of intra-abdominal complications after pancreatic resection: prospective randomized trial","volume":"237","author":"Suc","year":"2003","journal-title":"Ann Surg"},{"key":"key20161223072506546_ref1-bib86","doi-asserted-by":"publisher","first-page":"561","DOI":"10.1111\/hpb.12018","article-title":"Does fibrin glue sealant decrease the rate of anastomotic leak after a pancreaticoduodenectomy? Results of a prospective randomized trial","volume":"15","author":"Martin","year":"2013","journal-title":"HPB"},{"key":"key20161223072506546_ref1-bib87","doi-asserted-by":"publisher","first-page":"647","DOI":"10.1016\/j.ciresp.2012.05.007","article-title":"Use of fibrin based biological adhesives in the prevention of anastomotic leaks in the high risk digestive tract: preliminary results of the multicentre, prospective, randomised, controlled, and simple blind phase IV clinical trial: Protissucol001","volume":"10","author":"Oliver","year":"2012","journal-title":"CIR ESP"},{"key":"key20161223072506546_ref1-bib88","doi-asserted-by":"publisher","first-page":"197","DOI":"10.1007\/s13304-014-0257-0","article-title":"Laparoscopic sleeve gastrectomy: efficacy of fibrin sealant in reducing postoperative bleeding. A randomized controlled trial","volume":"66","author":"Musella","year":"2014","journal-title":"Updates Surg"},{"key":"key20161223072506546_ref1-bib89","first-page":"241","article-title":"Use of Tachosil\u00ae in bariatric surgery: preliminary experience in control of bleeding after sleeve gastrectomy","volume":"67","author":"Pilone","year":"2012","journal-title":"Minerva Chir"},{"key":"key20161223072506546_ref1-bib90","doi-asserted-by":"publisher","first-page":"1577","DOI":"10.1007\/s11695-015-1580-3","article-title":"Minimizing hemorrhagic complications in laparoscopic sleeve gastrectomy \u2013 a randomized controlled trial","volume":"25","author":"Sroka","year":"2015","journal-title":"Obes Surg"},{"key":"key20161223072506546_ref1-bib91","first-page":"157","article-title":"Contribution of fibrin glue to the reinforcement of esophageal anastomoses","volume":"21","author":"F\u00e9k\u00e9t\u00e9","year":"1992","journal-title":"Presse Med"},{"key":"key20161223072506546_ref1-bib92","first-page":"985","article-title":"Comparison of four different methods in staple line reinforcement during laparascopic sleeve gastrectomy","volume":"6","author":"Bulbuller","year":"2013","journal-title":"Int J Clin Exp Med"},{"key":"key20161223072506546_ref1-bib93","doi-asserted-by":"publisher","first-page":"476","DOI":"10.1007\/s11605-013-2442-8","article-title":"The study on the efficacy of fibrin glue in preventing post-traumatic focal pancreatitis (PTFP) after radical gastrectomy","volume":"18","author":"Huang","year":"2014","journal-title":"J Gastrointest Surg"},{"key":"key20161223072506546_ref1-bib94","doi-asserted-by":"publisher","first-page":"76","DOI":"10.1016\/j.ygyno.2008.03.005","article-title":"A randomized phase III trial of VH fibrin sealant to reduce lymphedema after inguinal lymph node dissection: a Gynecologic Oncology Group study","volume":"110","author":"Carlson","year":"2008","journal-title":"Gynecol Oncol"},{"key":"key20161223072506546_ref1-bib95","doi-asserted-by":"publisher","first-page":"32","DOI":"10.1016\/j.asj.2008.10.008","article-title":"Effect of sustained-release lidocaine on reduction of pain after subpectoral breast augmentation","volume":"29","author":"Zhibo","year":"2009","journal-title":"Aesthet Surg J"},{"key":"key20161223072506546_ref1-bib96","doi-asserted-by":"publisher","first-page":"393","DOI":"10.1046\/j.1524-4741.2003.09506.x","article-title":"Effect of fibrin glue on lymphatic drainage and on drain removal time after modified radical mastectomy: a prospective randomized study","volume":"9","author":"Ulusoy","year":"2003","journal-title":"Breast J"},{"key":"key20161223072506546_ref1-bib97","doi-asserted-by":"crossref","first-page":"982","DOI":"10.1177\/000313480006601016","article-title":"Effect of fibrin glue on lymphatic drainage after modified radical mastectomy: a prospective randomized trial","volume":"66","author":"Dinsmore","year":"2000","journal-title":"Am Surg"},{"key":"key20161223072506546_ref1-bib98","first-page":"263","article-title":"Fibrin adhesive in radical mastectomy","volume":"159","author":"Ud\u00e9n","year":"1993","journal-title":"Eur J Surg"},{"key":"key20161223072506546_ref1-bib99","doi-asserted-by":"publisher","first-page":"54","DOI":"10.1002\/bjs.4435","article-title":"Randomized clinical trial investigating the use of drains and fibrin sealant following surgery for breast cancer","volume":"91","author":"Jain","year":"2004","journal-title":"Br J Surg"},{"key":"key20161223072506546_ref1-bib100","doi-asserted-by":"publisher","first-page":"319","DOI":"10.1016\/j.amjsurg.2005.01.004","article-title":"Influence of fibrin glue on seroma formation after breast surgery","volume":"189","author":"Johnson","year":"2005","journal-title":"Am J Surg"},{"key":"key20161223072506546_ref1-bib101","doi-asserted-by":"publisher","first-page":"1381","DOI":"10.1002\/bjs.8874","article-title":"Randomized clinical trial on the effect of fibrin sealant on latissimus dorsi donor-site seroma formation after breast reconstruction","volume":"99","author":"Llewellyn-Bennett","year":"2012","journal-title":"Br J Surg"},{"key":"key20161223072506546_ref1-bib102","doi-asserted-by":"publisher","first-page":"92","DOI":"10.3346\/jkms.2009.24.1.92","article-title":"Fibrin glue reduces the duration of lymphatic drainage after lumpectomy and level II or III axillary lymph node dissection for breast cancer: a prospective randomized trial","volume":"24","author":"Ko","year":"2009","journal-title":"J Korean Med Sci"},{"key":"key20161223072506546_ref1-bib103","doi-asserted-by":"publisher","first-page":"643132","DOI":"10.1155\/2012\/643132","article-title":"Efficacy of fibrin glue on seroma formation after breast surgery","volume":"2012","author":"Miri Bonjar","year":"2012","journal-title":"Int J Breast Cancer"},{"key":"key20161223072506546_ref1-bib104","doi-asserted-by":"crossref","first-page":"209","DOI":"10.1177\/145749690409300307","article-title":"The effect of fibrin sealant combined with fibrinolysis inhibitor on reducing the amount of lymphatic leakage after axillary evacuation in breast cancer. A prospective randomized clinical trial","volume":"93","author":"Mustonen","year":"2004","journal-title":"Scand J Surg"},{"key":"key20161223072506546_ref1-bib105","first-page":"345","article-title":"Reduction of lymphatic drainage posterior to modified radical mastectomy with the application of fibrin glue","volume":"73","author":"Segura-Castillo","year":"2005","journal-title":"Cir Cir"},{"key":"key20161223072506546_ref1-bib106","first-page":"97","article-title":"Fibrin sealant reduces serous drainage and allows for earlier drain removal after axillary dissection: a randomized prospective trial","volume":"63","author":"Moore","year":"1997","journal-title":"Am Surg"},{"key":"key20161223072506546_ref1-bib107","doi-asserted-by":"publisher","first-page":"9","DOI":"10.1023\/A:1010671209279","article-title":"Sealing of postoperative axillary leakage after axillary lymphadenectomy using a fibrin glue coated collagen patch: a prospective randomised study","volume":"67","author":"Berger","year":"2001","journal-title":"Breast Cancer Res Treat"},{"key":"key20161223072506546_ref1-bib108","doi-asserted-by":"publisher","first-page":"439","DOI":"10.1159\/000008611","article-title":"Prevention of lymphorrhea by means of fibrin glue after axillary lymphadenectomy in breast cancer: prospective randomized trial","volume":"30","author":"Gilly","year":"1998","journal-title":"Eur Surg Res"},{"key":"key20161223072506546_ref1-bib109","doi-asserted-by":"publisher","first-page":"1210","DOI":"10.1016\/j.ijsu.2014.10.005","article-title":"The effects of low-thrombin fibrin sealant on wound serous drainage, seroma formation and length of postoperative stay in patients undergoing axillary node dissection for breast cancer: a randomized controlled trial","volume":"12","author":"Benevento","year":"2014","journal-title":"Int J Surg"},{"key":"key20161223072506546_ref1-bib110","doi-asserted-by":"publisher","first-page":"600","DOI":"10.1002\/jso.21531","article-title":"Does the use of fibrin glue prevent seroma formation after axillary lymphadenectomy for breast cancer? A prospective randomized trial in 159 patients","volume":"101","author":"Cipolla","year":"2010","journal-title":"J Surg Oncol"},{"key":"key20161223072506546_ref1-bib111","doi-asserted-by":"publisher","first-page":"591","DOI":"10.1016\/S1072-7515(01)00827-4","article-title":"Fibrin sealant reduces the duration and amount of fluid drainage after axillary dissection: a randomized prospective clinical trial","volume":"192","author":"Moore","year":"2001","journal-title":"J Am Coll Surg"},{"key":"key20161223072506546_ref1-bib112","doi-asserted-by":"publisher","first-page":"346","DOI":"10.1159\/000129419","article-title":"Does fibrin glue improve drainage after axillary lymph node dissection? Prospective and randomized study in humans","volume":"27","author":"Vaxman","year":"1995","journal-title":"Eur Surg Res"},{"key":"key20161223072506546_ref1-bib113","doi-asserted-by":"publisher","first-page":"918","DOI":"10.1002\/bjs.7462","article-title":"Randomized controlled trial of fibrin sealant to reduce postoperative drainage following elective lymph node dissection","volume":"98","author":"Swan","year":"2011","journal-title":"Br J Surg"},{"key":"key20161223072506546_ref1-bib114","first-page":"51","article-title":"The effect of fibrin adhesive on postoperative wound secretion after lymph node dissection","volume":"1","author":"Siim","year":"1994","journal-title":"Reg Cancer Treat"},{"key":"key20161223072506546_ref1-bib115","first-page":"194","article-title":"Efficacity of fibrin glue on lymphostasis during lymph node dissection. Prospective randomised study in 40 patients","volume":"48","author":"Gilly","year":"1994","journal-title":"Annales de Chirurgie"},{"key":"key20161223072506546_ref1-bib116","first-page":"1044","article-title":"Does administration of fibrin glue prevent development of lymphoceles after radical lymphadenectomy?","volume":"64","author":"Furrer","year":"1993","journal-title":"Chirurg"},{"key":"key20161223072506546_ref1-bib117","doi-asserted-by":"publisher","first-page":"275","DOI":"10.1186\/1477-7819-10-275","article-title":"Collagen sealant patch to reduce lymphatic drainage after lymph node dissection","volume":"10","author":"Di Monta","year":"2012","journal-title":"World J Surg Oncol"},{"key":"key20161223072506546_ref1-bib118","doi-asserted-by":"publisher","first-page":"884","DOI":"10.1016\/j.ejso.2008.09.016","article-title":"A prospective randomized trial: the influence of intraoperative application of fibrin glue after radical inguinal\/iliacal lymph node dissection on postoperative morbidity","volume":"35","author":"Neuss","year":"2009","journal-title":"Eur J Surg Oncol"},{"key":"key20161223072506546_ref1-bib119","doi-asserted-by":"publisher","first-page":"2285","DOI":"10.1016\/j.juro.2009.07.033","article-title":"The use of a surgical patch in the prevention of lymphoceles after extraperitoneal pelvic lymphadenectomy for prostate cancer: a randomized prospective pilot study","volume":"182","author":"Simonato","year":"2009","journal-title":"J Urol"},{"key":"key20161223072506546_ref1-bib120","doi-asserted-by":"publisher","first-page":"63","DOI":"10.1186\/1477-7819-6-63","article-title":"Fibrin sealant does not decrease seroma output or time to drain removal following inguino-femoral lymph node dissection in melanoma patients: a randomized controlled trial (NCT00506311)","volume":"6","author":"Mortenson","year":"2008","journal-title":"World J Surg Oncol"},{"key":"key20161223072506546_ref1-bib121","doi-asserted-by":"publisher","first-page":"43","DOI":"10.1006\/gyno.2001.6462","article-title":"Fibrin application for preventing lymphocysts after retroperitoneal lymphadenectomy in patients with gynecologic malignancies","volume":"84","author":"Scholz","year":"2002","journal-title":"Gynecol Oncol"},{"key":"key20161223072506546_ref1-bib122","doi-asserted-by":"publisher","first-page":"776","DOI":"10.1007\/s00268-003-6989-5","article-title":"Does fibrin glue reduce lymph leakage (pleural effusion) after extended esophagectomy? Prospective randomized clinical trial","volume":"27","author":"Tachibana","year":"2003","journal-title":"World J Surg"},{"key":"key20161223072506546_ref1-bib123","first-page":"1995","article-title":"The secretion inhibition effect of fibrin glue in mastectomy scars. A prospective, randomized, clinically controlled study","volume":"147","author":"Nielsen","year":"1985","journal-title":"Ugeskr Laeger"},{"key":"key20161223072506546_ref1-bib124","doi-asserted-by":"publisher","first-page":"383","DOI":"10.1016\/j.jtcvs.2008.04.014","article-title":"A prospective randomized trial comparing completion technique of fissures for lobectomy: stapler versus precision dissection and sealant","volume":"136","author":"Droghetti","year":"2008","journal-title":"J Thorac Cardiovasc Surg"},{"key":"key20161223072506546_ref1-bib125","doi-asserted-by":"publisher","first-page":"198","DOI":"10.1016\/j.ejcts.2006.11.033","article-title":"Efficiency of fleece-bound sealing (TachoSil) of air leaks in lung surgery: a prospective randomised trial","volume":"31","author":"Anegg","year":"2007","journal-title":"Eur J Cardiothorac Surg"},{"key":"key20161223072506546_ref1-bib126","doi-asserted-by":"publisher","first-page":"843","DOI":"10.1016\/j.jtcvs.2008.02.079","article-title":"Autologous fibrin sealant reduces the incidence of prolonged air leak and duration of chest tube drainage after lung volume reduction surgery: a prospective randomized blinded study","volume":"136","author":"Moser","year":"2008","journal-title":"J Thorac Cardiovasc Surg"},{"key":"key20161223072506546_ref1-bib127","doi-asserted-by":"publisher","first-page":"973","DOI":"10.1510\/icvts.2009.202770","article-title":"Air-leak management after upper lobectomy in patients with fused fissure and chronic obstructive pulmonary disease: a pilot trial comparing sealant and standard treatment","volume":"9","author":"Rena","year":"2009","journal-title":"Interact Cardiovasc Thorac Surg"},{"key":"key20161223072506546_ref1-bib128","doi-asserted-by":"publisher","first-page":"1587","DOI":"10.1016\/S0003-4975(02)04994-9","article-title":"Fibrin glue in pulmonary resection: a prospective, randomized, blinded study","volume":"75","author":"Fabian","year":"2003","journal-title":"Ann Thorac Surg"},{"key":"key20161223072506546_ref1-bib129","first-page":"559","article-title":"Efficacy and safety of fibrin sealant patch in the treatment of air leakage in thoracic surgery","volume":"68","author":"Lopez","year":"2013","journal-title":"Minerva Chir"},{"key":"key20161223072506546_ref1-bib130","doi-asserted-by":"publisher","first-page":"1217","DOI":"10.1016\/j.athoracsur.2011.05.104","article-title":"Safety and effectiveness of a new fibrin pleural air leak sealant: a multicenter, controlled, prospective, parallel-group, randomized clinical trial","volume":"92","author":"Gonfiotti","year":"2011","journal-title":"Ann Thorac Surg"},{"key":"key20161223072506546_ref1-bib131","doi-asserted-by":"publisher","first-page":"32","DOI":"10.1016\/j.jtcvs.2009.11.064","article-title":"A prospective, randomized trial comparing BioGlue and Vivostat for the control of alveolar air leak","volume":"140","author":"Belcher","year":"2010","journal-title":"J Thorac Cardiovasc Surg"},{"key":"key20161223072506546_ref1-bib132","doi-asserted-by":"publisher","first-page":"75","DOI":"10.1016\/1010-7940(93)90184-D","article-title":"The effect of fibrin glueing to seal bronchial and alveolar leakages after pulmonary resections and decortications","volume":"7","author":"Mouritzen","year":"1993","journal-title":"Eur J Cardiothorac Surg"},{"key":"key20161223072506546_ref1-bib133","doi-asserted-by":"publisher","first-page":"1187","DOI":"10.1016\/j.ejcts.2004.08.009","article-title":"The effect of autologous fibrin sealant (Vivostat) on morbidity after pulmonary lobectomy: a prospective randomised, blinded study","volume":"26","author":"Belboul","year":"2004","journal-title":"Eur J Cardiothorac Surg"},{"key":"key20161223072506546_ref1-bib134","doi-asserted-by":"publisher","first-page":"160","DOI":"10.1016\/j.ejcts.2003.11.018","article-title":"Efficacy and safety of topical application of human fibrinogen\/thrombin-coated collagen patch (TachoComb) for treatment of air leakage after standard lobectomy","volume":"25","author":"Lang","year":"2004","journal-title":"Eur J Cardiothorac Surg"},{"key":"key20161223072506546_ref1-bib135","doi-asserted-by":"publisher","first-page":"683","DOI":"10.1016\/j.ejcts.2010.03.061","article-title":"Efficacy and safety of TachoSil\u00ae versus standard treatment of air leakage after pulmonary lobectomy","volume":"38","author":"Marta","year":"2010","journal-title":"Eur J Cardiothorac Surg"},{"key":"key20161223072506546_ref1-bib136","doi-asserted-by":"publisher","first-page":"661","DOI":"10.1093\/icvts\/ivs571","article-title":"Efficacy and safety of human fibrinogen-thrombin patch (TachoSil\u00ae) in the treatment of postoperative air leakage in patients submitted to redo surgery for lung malignancies: a randomized trial","volume":"16","author":"Filosso","year":"2013","journal-title":"Interact Cardiovasc Thorac Surg"},{"key":"key20161223072506546_ref1-bib137","doi-asserted-by":"publisher","first-page":"1028","DOI":"10.1016\/j.athoracsur.2003.08.041","article-title":"Sealing of the mediastinum with a local hemostyptic agent reduces chest tube duration after complete mediastinal lymph node dissection for stage I and II non-small cell lung carcinoma","volume":"77","author":"Czerny","year":"2004","journal-title":"Ann Thorac Surg"},{"key":"key20161223072506546_ref1-bib138","doi-asserted-by":"publisher","first-page":"482","DOI":"10.1016\/S0003-4975(98)00470-6","article-title":"Vivostat system autologous fibrin sealant: preliminary study in elective coronary bypass grafting","volume":"66","author":"Kjaergard","year":"1998","journal-title":"Ann Thorac Surg"},{"key":"key20161223072506546_ref1-bib139","doi-asserted-by":"publisher","first-page":"1173","DOI":"10.1016\/S0003-4975(99)01560-X","article-title":"Bleeding from the sternal marrow can be stopped using Vivostat patient-derived fibrin sealant","volume":"69","author":"Kjaergard","year":"2000","journal-title":"Ann Thorac Surg"},{"key":"key20161223072506546_ref1-bib140","doi-asserted-by":"publisher","first-page":"708","DOI":"10.1016\/j.ejcts.2009.04.057","article-title":"TachoSil surgical patch versus conventional haemostatic fleece material for control of bleeding in cardiovascular surgery: a randomised controlled trial","volume":"36","author":"Maisano","year":"2009","journal-title":"Eur J Cardiothorac Surg"},{"key":"key20161223072506546_ref1-bib141","doi-asserted-by":"publisher","first-page":"352","DOI":"10.1177\/1076029606291406","article-title":"A pilot study of the effects of Vivostat patient-derived fibrin sealant in reducing blood loss in primary hip arthroplasty","volume":"12","author":"Lassen","year":"2006","journal-title":"Clin Appl Thromb Hemost"},{"key":"key20161223072506546_ref1-bib142","doi-asserted-by":"publisher","first-page":"272","DOI":"10.1007\/s11999-013-3036-1","article-title":"Intraarticular fibrinogen does not reduce blood loss in TKA: a randomized clinical trial","volume":"472","author":"Heyse","year":"2014","journal-title":"Clin Orthop Relat Res"},{"key":"key20161223072506546_ref1-bib143","doi-asserted-by":"publisher","first-page":"2001","DOI":"10.2106\/JBJS.L.01182","article-title":"Efficacy and safety of fibrin glue and tranexamic acid to prevent postoperative blood loss in total knee arthroplasty: a randomized controlled clinical trial","volume":"95","author":"Aguilera","year":"2013","journal-title":"J Bone Joint Surg Am"},{"key":"key20161223072506546_ref1-bib144","doi-asserted-by":"publisher","first-page":"1503","DOI":"10.2106\/00004623-200110000-00007","article-title":"Use of fibrin sealant to reduce bloody drainage and hemoglobin loss after total knee arthroplasty: a brief note on a randomized prospective trial","volume":"83\u2013A","author":"Wang","year":"2001","journal-title":"J Bone Joint Surg Am"},{"key":"key20161223072506546_ref1-bib145","doi-asserted-by":"publisher","first-page":"1147","DOI":"10.1007\/s00402-012-1519-2","article-title":"Fibrin sealants in orthopaedic surgery: practical experiences derived from use of QUIXIL\u00ae in total knee arthroplasty","volume":"132","author":"Kluba","year":"2012","journal-title":"Arch Orthop Trauma Surg"},{"key":"key20161223072506546_ref1-bib146","doi-asserted-by":"publisher","first-page":"295","DOI":"10.1016\/j.knee.2011.06.004","article-title":"Reducing blood loss in primary knee arthroplasty: a prospective randomised controlled trial of tranexamic acid and fibrin spray","volume":"19","author":"McConnell","year":"2012","journal-title":"Knee"},{"key":"key20161223072506546_ref1-bib147","doi-asserted-by":"publisher","first-page":"306","DOI":"10.1302\/0301-620X.89B3.17565","article-title":"Comparison of topical fibrin spray and tranexamic acid on blood loss after total knee replacement: a prospective, randomised controlled trial","volume":"89","author":"Molloy","year":"2007","journal-title":"J Bone Joint Surg Br"},{"key":"key20161223072506546_ref1-bib148","doi-asserted-by":"publisher","first-page":"145","DOI":"10.1007\/s10195-012-0198-7","article-title":"Fibrin tissue adhesive reduces postoperative blood loss in total knee arthroplasty","volume":"13","author":"Sabatini","year":"2012","journal-title":"J Orthop Traumatol"},{"key":"key20161223072506546_ref1-bib149","doi-asserted-by":"publisher","first-page":"1516","DOI":"10.1016\/j.arth.2014.02.024","article-title":"Is the newest fibrin sealant an effective strategy to reduce blood loss after total knee arthroplasty? A randomized controlled study","volume":"29","author":"Randelli","year":"2014","journal-title":"J Arthroplasty"},{"key":"key20161223072506546_ref1-bib150","doi-asserted-by":"publisher","first-page":"153","DOI":"10.3109\/17453674.2013.769082","article-title":"No effect of fibrin sealant on drain output or functional recovery following simultaneous bilateral total knee arthroplasty: a randomized, double-blind, placebo-controlled study","volume":"84","author":"Skovgaard","year":"2013","journal-title":"Acta Orthop"},{"key":"key20161223072506546_ref1-bib151","doi-asserted-by":"publisher","first-page":"22","DOI":"10.1016\/j.tracli.2015.01.001","article-title":"Medical and economic impact of a haemostatic sealant on the rate of transfusion after total knee arthroplasty","volume":"22","author":"Choufani","year":"2015","journal-title":"Transfus Clin Biol"},{"key":"key20161223072506546_ref1-bib152","doi-asserted-by":"publisher","first-page":"117","DOI":"10.1177\/230949900601400202","article-title":"Effectiveness of autologous fibrin tissue adhesive in reducing postoperative blood loss during total hip arthroplasty: a prospective randomised study of 100 cases","volume":"14","author":"Mawatari","year":"2006","journal-title":"J Orthop Surg (Hong Kong)"},{"key":"key20161223072506546_ref1-bib153","doi-asserted-by":"publisher","first-page":"399","DOI":"10.1615\/JLongTermEffMedImplants.v13.i5.50","article-title":"Fibrin sealant reduces perioperative blood loss in total hip replacement","volume":"13","author":"Wang","year":"2003","journal-title":"J Long Term Eff Med Implants"},{"key":"key20161223072506546_ref1-bib154","doi-asserted-by":"publisher","first-page":"1213","DOI":"10.1007\/s00264-013-1903-8","article-title":"Blood loss reduction in cementless total hip replacement with fibrin spray or bipolar sealer: a randomised controlled trial on ninety five patients","volume":"37","author":"Falez","year":"2013","journal-title":"Int Orthop"},{"key":"key20161223072506546_ref1-bib155","first-page":"25","article-title":"Platelet-rich fibrin in arthroscopic repair of massive rotator cuff tears: a prospective randomized pilot clinical trial","volume":"79","author":"Antu\u00f1a","year":"2013","journal-title":"Acta Orthop Belg"},{"key":"key20161223072506546_ref1-bib156","doi-asserted-by":"publisher","first-page":"660","DOI":"10.3109\/17453674.2011.623568","article-title":"Reduction of blood loss in primary hip arthroplasty with tranexamic acid or fibrin spray","volume":"82","author":"McConnell","year":"2011","journal-title":"Acta Orthop"},{"key":"key20161223072506546_ref1-bib157","doi-asserted-by":"publisher","first-page":"558","DOI":"10.1038\/eye.2009.136","article-title":"Amniotic membrane transplantation using fibrin glue in pterygium surgery: a comparative randomised clinical trial","volume":"24","author":"Kucukerdonmez","year":"2010","journal-title":"Eye"},{"key":"key20161223072506546_ref1-bib158","first-page":"316","article-title":"Comparison of fibrin glue and suture technique in pterygium surgery performed with limbal autograft","volume":"3","author":"Y\u00fcksel","year":"2010","journal-title":"Int J Ophthalmol"},{"key":"key20161223072506546_ref1-bib159","doi-asserted-by":"publisher","first-page":"1168","DOI":"10.1097\/01.ico.0000240087.32922.ee","article-title":"Pterygium surgery: fibrin glue versus Vicryl sutures for conjunctival closure","volume":"25","author":"Bahar","year":"2006","journal-title":"Cornea"},{"key":"key20161223072506546_ref1-bib160","doi-asserted-by":"publisher","first-page":"584","DOI":"10.1111\/j.1442-9071.2009.02105.x","article-title":"Comparison of fibrin glue with sutures for pterygium excision surgery with conjunctival autografts","volume":"37","author":"Hall","year":"2009","journal-title":"Clin Exp Ophthalmol"},{"key":"key20161223072506546_ref1-bib161","doi-asserted-by":"publisher","first-page":"1206","DOI":"10.1136\/bjo.2008.139600","article-title":"Fibrin glue versus sutures for conjunctival autografting in pterygium surgery: a prospective comparative study","volume":"92","author":"Karalezli","year":"2008","journal-title":"Br J Ophthalmol"},{"key":"key20161223072506546_ref1-bib162","doi-asserted-by":"publisher","first-page":"298","DOI":"10.1111\/j.1600-0420.2005.00465.x","article-title":"The cut-and-paste method for primary pterygium surgery: long-term follow-up","volume":"83","author":"Koranyi","year":"2005","journal-title":"Acta Ophthalmol Scand"},{"key":"key20161223072506546_ref1-bib163","doi-asserted-by":"publisher","first-page":"1233","DOI":"10.1007\/s10792-014-0013-y","article-title":"Comparison of efficacy of three surgical methods of conjunctival autograft fixation in the treatment of pterygium","volume":"34","author":"Sati","year":"2014","journal-title":"Int Ophthalmol"},{"key":"key20161223072506546_ref1-bib164","doi-asserted-by":"publisher","first-page":"291","DOI":"10.1016\/S0161-6420(02)01558-0","article-title":"Fibrin glue versus N-butyl-2-cyanoacrylate in corneal perforations","volume":"110","author":"Sharma","year":"2003","journal-title":"Ophthalmology"},{"key":"key20161223072506546_ref1-bib165","doi-asserted-by":"publisher","first-page":"485","DOI":"10.1097\/ICO.0b013e3181c29696","article-title":"Fibrin adhesive is better than sutures in pterygium surgery","volume":"29","author":"Ratnalingam","year":"2010","journal-title":"Cornea"},{"key":"key20161223072506546_ref1-bib166","doi-asserted-by":"publisher","first-page":"123","DOI":"10.1590\/S0004-27492011000200011","article-title":"Efficacy of fibrin tissue adhesive in the attachment of autogenous conjuntival graft on primary pterygium surgery","volume":"74","author":"Rubin","year":"2011","journal-title":"Arq Bras Oftalmol"},{"key":"key20161223072506546_ref1-bib167","doi-asserted-by":"publisher","first-page":"215","DOI":"10.1136\/bjo.2008.145516","article-title":"Fibrin glue versus sutures for attaching the conjunctival autograft in pterygium surgery: a prospective observer masked clinical trial","volume":"93","author":"Srinivasan","year":"2009","journal-title":"Br J Ophthalmol"},{"key":"key20161223072506546_ref1-bib168","doi-asserted-by":"publisher","first-page":"667","DOI":"10.1016\/j.ophtha.2004.08.028","article-title":"Comparison of fibrin glue and sutures for attaching conjunctival autografts after pterygium excision","volume":"112","author":"Uy","year":"2005","journal-title":"Ophthalmology"},{"key":"key20161223072506546_ref1-bib169","doi-asserted-by":"publisher","first-page":"399","DOI":"10.1080\/02713680701294723","article-title":"Fibrin glue versus vicryl sutures for primary conjunctival closure in pterygium surgery: long-term results","volume":"32","author":"Bahar","year":"2007","journal-title":"Curr Eye Res"},{"key":"key20161223072506546_ref1-bib170","first-page":"129","article-title":"Management of conjunctival wounds with suture or fibrin glue following intraocular lens implantation \u2013 a comparative study","volume":"86","author":"Mellin","year":"1989","journal-title":"Fortschr Ophthalmol"},{"key":"key20161223072506546_ref1-bib171","first-page":"1326","article-title":"Use of fibrin glue in the management of recurrent pterygium by conjunctival autograft","volume":"31","author":"Malik","year":"2010","journal-title":"Saudi Med J"},{"key":"key20161223072506546_ref1-bib172","doi-asserted-by":"publisher","first-page":"670","DOI":"10.1097\/01.sla.0000186440.02977.de","article-title":"Fibrin sealant versus mechanical stapling for mesh fixation during endoscopic extraperitoneal inguinal hernioplasty: a randomized prospective trial","volume":"242","author":"Lau","year":"2005","journal-title":"Ann Surg"},{"key":"key20161223072506546_ref1-bib173","doi-asserted-by":"publisher","first-page":"1206","DOI":"10.1007\/s00464-007-9587-z","article-title":"Pain after laparascopic bilateral hernioplasty: early results of a prospective randomized double-blind study comparing fibrin versus staples","volume":"22","author":"Boldo","year":"2008","journal-title":"Surg Endosc"},{"key":"key20161223072506546_ref1-bib174","doi-asserted-by":"publisher","first-page":"185","DOI":"10.1007\/s10029-012-1020-4","article-title":"Beneficial effects of fibrin glue (Quixil) versus Lichtenstein conventional technique in inguinal hernia repair: a randomized clinical trial","volume":"18","author":"Bracale","year":"2014","journal-title":"Hernia"},{"key":"key20161223072506546_ref1-bib175","doi-asserted-by":"publisher","first-page":"103","DOI":"10.4149\/bll_2012_024","article-title":"Comparison of self-gripping mesh with mesh fixation with fibrin-glue in laparoscopic hernia repair (TAPP)","volume":"113","author":"Cambal","year":"2012","journal-title":"Bratisl Lek Listy"},{"key":"key20161223072506546_ref1-bib176","doi-asserted-by":"publisher","first-page":"650","DOI":"10.1097\/SLA.0b013e31824b32bf","article-title":"Randomized, controlled, blinded trial of Tisseel\/Tissucol for mesh fixation in patients undergoing Lichtenstein technique for primary inguinal hernia repair: results of the TIMELI trial","volume":"255","author":"Campanelli","year":"2012","journal-title":"Ann Surg"},{"key":"key20161223072506546_ref1-bib177","doi-asserted-by":"publisher","first-page":"315","DOI":"10.1016\/S0039-6060(99)70242-4","article-title":"Inguinal hernia repair in patients with coagulation problems: prevention of postoperative bleeding with human fibrin glue","volume":"125","author":"Canonico","year":"1999","journal-title":"Surgery"},{"key":"key20161223072506546_ref1-bib178","doi-asserted-by":"publisher","first-page":"432","DOI":"10.1097\/SLA.0b013e3182a6c513","article-title":"Randomized double-blinded prospective trial of fibrin sealant spray versus mechanical stapling in laparoscopic total extraperitoneal hernioplasty","volume":"259","author":"Chan","year":"2014","journal-title":"Ann Surg"},{"key":"key20161223072506546_ref1-bib179","doi-asserted-by":"publisher","first-page":"127","DOI":"10.1007\/s10029-011-0869-y","article-title":"Sutureless hernioplasty with light-weight mesh and fibrin glue versus Lichtenstein procedure: a comparison of outcomes focusing on chronic postoperative pain","volume":"16","author":"Lionetti","year":"2012","journal-title":"Hernia"},{"key":"key20161223072506546_ref1-bib180","doi-asserted-by":"publisher","first-page":"222","DOI":"10.1097\/01.sla.0000245832.59478.c6","article-title":"Use of human fibrin glue (Tissucol) versus staples for mesh fixation in laparoscopic transabdominal preperitoneal hernioplasty: a prospective, randomized study","volume":"245","author":"Lovisetto","year":"2007","journal-title":"Ann Surg"},{"key":"key20161223072506546_ref1-bib181","doi-asserted-by":"publisher","first-page":"2727","DOI":"10.1007\/s00464-012-2766-6","article-title":"Randomized clinical trial of fibrin glue versus tacked fixation in laparoscopic groin hernia repair","volume":"27","author":"Tolver","year":"2013","journal-title":"Surg Endosc"},{"key":"key20161223072506546_ref1-bib182","doi-asserted-by":"publisher","first-page":"34","DOI":"10.1016\/j.amjsurg.2010.05.004","article-title":"Comparing chronic pain between fibrin sealant and suture fixation for bilayer polypropylene mesh inguinal hernioplasty: a randomized clinical trial","volume":"202","author":"Wong","year":"2011","journal-title":"Am J Surg"},{"key":"key20161223072506546_ref1-bib183","doi-asserted-by":"publisher","first-page":"511","DOI":"10.1007\/s10029-013-1101-z","article-title":"Fibrin sealant for mesh fixation in laparoscopic umbilical hernia repair: 1-year results of a randomized controlled double-blinded study","volume":"174","author":"Eriksen","year":"2013","journal-title":"Hernia"},{"key":"key20161223072506546_ref1-bib184","first-page":"660","article-title":"Human fibrin glue sealing versus suture polypropylene fixation in Lichtenstein inguinal herniorrhaphy: a prospective observational study","volume":"109","author":"Damiano","year":"2014","journal-title":"Chirurgia"},{"key":"key20161223072506546_ref1-bib185","doi-asserted-by":"publisher","first-page":"40","DOI":"10.1016\/j.surg.2007.02.013","article-title":"Quantification of pain in laparoscopic transabdominal preperitoneal (TAPP) inguinal hernioplasty identifies marked differences between prosthesis fixation systems","volume":"142","author":"Olmi","year":"2007","journal-title":"Surgery"},{"key":"key20161223072506546_ref1-bib186","doi-asserted-by":"publisher","first-page":"339","DOI":"10.1001\/archfaci.10.5.339","article-title":"Efficacy of fibrin sealant (human) (Evicel) in rhinoplasty: a prospective, randomized, single-blind trial of the use of fibrin sealant in lateral osteotomy","volume":"10","author":"Pryor","year":"2008","journal-title":"Arch Facial Plast Surg"},{"key":"key20161223072506546_ref1-bib187","doi-asserted-by":"publisher","first-page":"568","DOI":"10.1007\/s00266-006-0020-0","article-title":"Use of aerosolized bovine-prepared fibrin glue for skin fixation after primary open rhinoplasty: a prospective randomized and controlled trial","volume":"30","author":"Prado","year":"2006","journal-title":"Aesthetic Plast Surg"},{"key":"key20161223072506546_ref1-bib188","first-page":"185","article-title":"The use of fibrin glue as hemostatic in endonasal operations: a prospective, randomized study","volume":"40","author":"Vaiman","year":"2002","journal-title":"Rhinology"},{"key":"key20161223072506546_ref1-bib189","first-page":"571","article-title":"Fibrin sealant: alternative to nasal packing in endonasal operations. A prospective randomized study","volume":"7","author":"Vaiman","year":"2005","journal-title":"Isr Med Assoc J"},{"key":"key20161223072506546_ref1-bib190","doi-asserted-by":"publisher","first-page":"335","DOI":"10.2500\/ajra.2014.28.4047","article-title":"Effect of aerosolized fibrin sealant on hemostasis and wound healing after endoscopic sinus surgery: a prospective randomized study","volume":"28","author":"Yu","year":"2014","journal-title":"Am J Rhinol Allergy"},{"key":"key20161223072506546_ref1-bib191","doi-asserted-by":"publisher","first-page":"237","DOI":"10.1177\/000348940511400313","article-title":"Use of fibrin glue as a hemostatic in endoscopic sinus surgery","volume":"114","author":"Vaiman","year":"2005","journal-title":"Ann Otol Rhinol Laryngol"},{"key":"key20161223072506546_ref1-bib192","doi-asserted-by":"publisher","first-page":"483","DOI":"10.1177\/000348940611500701","article-title":"Fibrin sealant reduces pain after tonsillectomy: prospective randomized study","volume":"115","author":"Vaiman","year":"2006","journal-title":"Ann Otol Rhinol Laryngol"},{"key":"key20161223072506546_ref1-bib193","doi-asserted-by":"publisher","first-page":"461","DOI":"10.1016\/S0741-5214(99)70073-X","article-title":"Hemostatic efficacy of fibrin sealant (human) on expanded poly-tetrafluoroethylene carotid patch angioplasty: a randomized clinical trial","volume":"30","author":"Jackson","year":"1999","journal-title":"J Vasc Surg"},{"key":"key20161223072506546_ref1-bib194","doi-asserted-by":"publisher","first-page":"60","DOI":"10.1186\/1749-8090-4-60","article-title":"Efficacy of TachoSil patches in controlling Dacron suture-hole bleeding after abdominal aortic aneurysm open repair","volume":"4","author":"Bajardi","year":"2009","journal-title":"J Cardiothorac Surg"},{"key":"key20161223072506546_ref1-bib195","doi-asserted-by":"publisher","first-page":"871","DOI":"10.1097\/01.SLA.0000071565.02994.DA","article-title":"Fibrin sealant improves hemostasis in peripheral vascular surgery: a randomized prospective trial","volume":"237","author":"Schenk","year":"2003","journal-title":"Ann Surg"},{"key":"key20161223072506546_ref1-bib196","doi-asserted-by":"crossref","first-page":"728","DOI":"10.1177\/000313480206800814","article-title":"Fibrin sealant facilitates hemostasis in arteriovenous polytetrafluoroethylene grafts for renal dialysis access","volume":"68","author":"Schenk","year":"2002","journal-title":"Am Surg"},{"key":"key20161223072506546_ref1-bib197","doi-asserted-by":"publisher","first-page":"134","DOI":"10.1016\/j.jvs.2012.01.009","article-title":"A prospective randomized study comparing fibrin sealant to manual compression for the treatment of anastomotic suture-hole bleeding in expanded polytetrafluoroethylene grafts","volume":"56","author":"Saha","year":"2012","journal-title":"J Vasc Surg"},{"key":"key20161223072506546_ref1-bib198","doi-asserted-by":"publisher","first-page":"1784","DOI":"10.1002\/bjs.7235","article-title":"Randomized clinical trial of tranexamic acid-free fibrin sealant during vascular surgical procedures","volume":"97","author":"Chalmers","year":"2010","journal-title":"Br J Surg"},{"key":"key20161223072506546_ref1-bib199","doi-asserted-by":"publisher","first-page":"766","DOI":"10.1016\/S0741-5214(03)00474-9","article-title":"Prospective randomized multicenter trial of fibrin sealant versus thrombin-soaked gelatin sponge for suture- or needle-hole bleeding from polytetrafluoroethylene femoral artery grafts","volume":"38","author":"Taylor","year":"2003","journal-title":"J Vasc Surg"},{"key":"key20161223072506546_ref1-bib200","doi-asserted-by":"publisher","first-page":"549","DOI":"10.1016\/j.ejvs.2004.01.018","article-title":"Randomised controlled trial to evaluate the efficacy of TachoComb H patches in controlling PTFE suture-hole bleeding","volume":"27","author":"Joseph","year":"2004","journal-title":"Eur J Vasc Endovasc Surg"},{"key":"key20161223072506546_ref1-bib201","doi-asserted-by":"publisher","first-page":"91","DOI":"10.1016\/S1078-5884(05)80203-5","article-title":"Fibrin sealant reduces suture line bleeding during carotid endarterectomy: a randomised trial","volume":"10","author":"Milne","year":"1995","journal-title":"Eur J Vasc Endovasc Surg"},{"key":"key20161223072506546_ref1-bib202","doi-asserted-by":"publisher","first-page":"1259","DOI":"10.1007\/s00268-005-7863-4","article-title":"Randomized trial comparing quixil surgical sealant with kaltostat hemostatic dressing to control suture line bleeding after carotid endarterectomy with ePTFE patch reconstruction","volume":"29","author":"Sintler","year":"2005","journal-title":"World J Surg"},{"key":"key20161223072506546_ref1-bib203","doi-asserted-by":"publisher","first-page":"210","DOI":"10.1111\/j.1423-0410.1996.tb01328.x","article-title":"A randomised trial of fibrin sealant in peripheral vascular surgery","volume":"70","author":"Milne","year":"1996","journal-title":"Vox Sang"},{"key":"key20161223072506546_ref1-bib204","doi-asserted-by":"publisher","first-page":"813","DOI":"10.1016\/j.avsg.2010.12.016","article-title":"Use of fibrin sealant as a hemostatic agent in expanded polytetrafluoroethylene graft placement surgery","volume":"25","author":"Saha","year":"2011","journal-title":"Ann Vasc Surg"},{"key":"key20161223072506546_ref1-bib205","first-page":"553","article-title":"Collagen patch coated with fibrin glue components. Treatment of suture hole bleedings in vascular reconstruction","volume":"41","author":"Czerny","year":"2000","journal-title":"J Cardiovasc Surg"},{"key":"key20161223072506546_ref1-bib206","doi-asserted-by":"publisher","first-page":"22","DOI":"10.1007\/s10151-007-0320-7","article-title":"Impact of fibrin sealant on Limberg flap technique: results of a randomized controlled trial","volume":"11","author":"Altinli","year":"2007","journal-title":"Tech Coloproctol"},{"key":"key20161223072506546_ref1-bib207","doi-asserted-by":"publisher","first-page":"367","DOI":"10.1097\/01.SAP.0000041484.22953.6D","article-title":"Hemostatic effect of Vivostat patient-derived fibrin sealant on split-thickness skin graft donor sites","volume":"50","author":"Drake","year":"2003","journal-title":"Ann Plast Surg"},{"key":"key20161223072506546_ref1-bib208","doi-asserted-by":"publisher","first-page":"308","DOI":"10.1111\/j.1524-475X.2007.00231.x","article-title":"Treatment of recalcitrant venous leg ulcers with autologous keratinocytes in fibrin sealant: a multinational randomized controlled clinical trial","volume":"15","author":"Vanscheidt","year":"2007","journal-title":"Wound Repair Regen"},{"key":"key20161223072506546_ref1-bib209","doi-asserted-by":"publisher","first-page":"1431","DOI":"10.1097\/PRS.0b013e318188202c","article-title":"Effect of topical autologous platelet-rich fibrin versus no intervention on epithelialization of donor sites and meshed split-thickness skin autografts: a randomized clinical trial","volume":"122","author":"Danielsen","year":"2008","journal-title":"Plast Reconstr Surg"},{"key":"key20161223072506546_ref1-bib210","doi-asserted-by":"publisher","first-page":"213","DOI":"10.1055\/s-0030-1247716","article-title":"Fibrin sealant for fasciocutaneous flaps","volume":"26","author":"Erba","year":"2010","journal-title":"J Reconstr Microsurg"},{"key":"key20161223072506546_ref1-bib211","doi-asserted-by":"publisher","first-page":"139e","DOI":"10.1097\/PRS.0b013e318299c6f4","article-title":"Prospective randomized controlled trial: fibrin sealant reduces split skin graft donor-site pain","volume":"132","author":"Healy","year":"2013","journal-title":"Plast Reconstr Surg"},{"key":"key20161223072506546_ref1-bib212","doi-asserted-by":"publisher","first-page":"479","DOI":"10.1007\/s11845-010-0549-4","article-title":"Are postoperative drains necessary with the Karydakis flap for treatment of pilonidal sinus? (Can fibrin glue be replaced to drains?) A prospective randomized trial","volume":"180","author":"S\u00f6zen","year":"2011","journal-title":"Ir J Med Sci"},{"key":"key20161223072506546_ref1-bib213","doi-asserted-by":"publisher","first-page":"370","DOI":"10.1007\/s00266-011-9807-8","article-title":"Suction drains, quilting sutures, and fibrin sealant in the prevention of seroma formation in abdominoplasty: which is the best strategy?","volume":"36","author":"Bercial","year":"2012","journal-title":"Aesthetic Plast Surg"},{"key":"key20161223072506546_ref1-bib214","doi-asserted-by":"publisher","first-page":"621","DOI":"10.5999\/aps.2013.40.5.621","article-title":"Fibrin sealant and lipoabdominoplasty in obese grade 1 and 2 patients","volume":"40","author":"Mabrouk","year":"2013","journal-title":"Arch Plast Surg"},{"key":"key20161223072506546_ref1-bib215","doi-asserted-by":"publisher","first-page":"387","DOI":"10.1007\/s00238-001-0317-9","article-title":"Can fibrin sealant be used to prevent postoperative drainage? A prospective randomized double blind trial","volume":"24","author":"Oliver","year":"2002","journal-title":"Eur J Plast Surg"},{"key":"key20161223072506546_ref1-bib216","doi-asserted-by":"publisher","first-page":"1736","DOI":"10.1007\/s10350-006-0718-8","article-title":"Fibrin glue as an adjunct to flap repair of anal fistulas: a randomized, controlled study","volume":"49","author":"Ellis","year":"2006","journal-title":"Dis Colon Rectum"},{"key":"key20161223072506546_ref1-bib217","doi-asserted-by":"publisher","first-page":"82","DOI":"10.1111\/j.1463-1318.2009.02056.x","article-title":"Seton or glue for trans-sphincteric anal fistulae: a prospective randomized crossover clinical trial","volume":"13","author":"Altomare","year":"2011","journal-title":"Colorectal Dis"},{"key":"key20161223072506546_ref1-bib218","doi-asserted-by":"publisher","first-page":"1608","DOI":"10.1007\/s10350-004-7247-0","article-title":"A randomized, controlled trial of fibrin glue vs. conventional treatment for anal fistula","volume":"45","author":"Lindsey","year":"2002","journal-title":"Dis Colon Rectum"},{"key":"key20161223072506546_ref1-bib219","doi-asserted-by":"publisher","first-page":"94","DOI":"10.1111\/j.1463-1318.2009.02087.x","article-title":"Management of idiopathic anal fistula using cross-linked collagen: a prospective phase 1 study","volume":"13","author":"Hammond","year":"2011","journal-title":"Colorectal Dis"},{"key":"key20161223072506546_ref1-bib220","doi-asserted-by":"publisher","first-page":"186350","DOI":"10.1155\/2011\/186350","article-title":"Staged mucosal advancement flap versus staged fibrin sealant in the treatment of complex perianal fistulas","volume":"2011","author":"van der Hagen","year":"2011","journal-title":"Gastroenterol Res Pract"},{"key":"key20161223072506546_ref1-bib221","doi-asserted-by":"publisher","first-page":"1156","DOI":"10.1016\/j.eururo.2007.04.027","article-title":"Efficacy and safety of TachoSil as haemostatic treatment versus standard suturing in kidney tumour resection: a randomised prospective study","volume":"52","author":"Siemer","year":"2007","journal-title":"Eur Urol"},{"key":"key20161223072506546_ref1-bib222","doi-asserted-by":"publisher","first-page":"145","DOI":"10.1016\/j.juro.2012.03.011","article-title":"TachoSil\u00ae sealed tubeless percutaneous nephrolithotomy to reduce urine leakage and bleeding: outcome of a randomized controlled study","volume":"188","author":"Cormio","year":"2012","journal-title":"J Urol"},{"key":"key20161223072506546_ref1-bib223","doi-asserted-by":"publisher","first-page":"672","DOI":"10.1111\/j.1464-410X.1986.tb05910.x","article-title":"Reduction of post-operative bleeding after transurethral resection of the prostate by local instillation of fibrin adhesive (Beriplast)","volume":"58","author":"Luke","year":"1986","journal-title":"Br J Urol"},{"key":"key20161223072506546_ref1-bib224","doi-asserted-by":"crossref","first-page":"267","DOI":"10.1159\/000472512","article-title":"Fibrin adhesive sealing of ureter after ureteral stone surgery. A controlled clinical trial","volume":"11","author":"Schultz","year":"1985","journal-title":"Eur Urol"},{"key":"key20161223072506546_ref1-bib225","doi-asserted-by":"publisher","first-page":"374","DOI":"10.2310\/7070.2005.34603","article-title":"Tisseel and its effects on wound drainage post-thyroidectomy: prospective, randomized, blinded, controlled study","volume":"34","author":"Uwiera","year":"2005","journal-title":"J Otolaryngol"},{"key":"key20161223072506546_ref1-bib226","doi-asserted-by":"publisher","first-page":"911","DOI":"10.1097\/01.PRS.0000153219.32665.D5","article-title":"Early postoperative efficacy of fibrin glue in face lifts: a prospective randomized trial","volume":"115","author":"Marchac","year":"2005","journal-title":"Plast Reconstr Surg"},{"key":"key20161223072506546_ref1-bib227","doi-asserted-by":"publisher","first-page":"29","DOI":"10.1001\/archfacial.2008.511","article-title":"Efficacy of Crosseal fibrin sealant (human) in rhytidectomy","volume":"11","author":"Lee","year":"2009","journal-title":"Arch Facial Plast Surg"},{"key":"key20161223072506546_ref1-bib228","doi-asserted-by":"publisher","first-page":"2101","DOI":"10.1097\/00006534-200112000-00044","article-title":"A prospective, randomized, double-blind trial of the use of fibrin sealant for face lifts","volume":"108","author":"Oliver","year":"2001","journal-title":"Plast Reconstr Surg"},{"key":"key20161223072506546_ref1-bib229","doi-asserted-by":"publisher","first-page":"1432","DOI":"10.1016\/j.joms.2003.01.001","article-title":"Tranexamic acid mouthwash versus autologous fibrin glue in patients taking warfarin undergoing dental extractions: a randomized prospective clinical study","volume":"61","author":"Carter","year":"2003","journal-title":"J Oral Maxillofac Surg"},{"key":"key20161223072506546_ref1-bib230","doi-asserted-by":"publisher","first-page":"36","DOI":"10.2310\/7070.2005.4032","article-title":"Tisseel to reduce postparotidectomy wound drainage: randomized, prospective, controlled trial","volume":"35","author":"Maharaj","year":"2006","journal-title":"J Otolaryngol"},{"key":"key20161223072506546_ref1-bib231","doi-asserted-by":"publisher","first-page":"487","DOI":"10.1177\/1090820X13479969","article-title":"Randomized, controlled, phase 3 study to evaluate the safety and efficacy of fibrin sealant VH S\/D 4 s-apr (Artiss) to improve tissue adherence in subjects undergoing rhytidectomy","volume":"33","author":"Hester","year":"2013","journal-title":"Aesthet Surg J"},{"key":"key20161223072506546_ref1-bib232","doi-asserted-by":"publisher","first-page":"1086","DOI":"10.1016\/j.fertnstert.2010.11.024","article-title":"A prospective, controlled, randomized, multicenter, exploratory pilot study evaluating the safety and potential trends in efficacy of Adhexil","volume":"95","author":"Diamond","year":"2011","journal-title":"Fertil Steril"},{"key":"key20161223072506546_ref1-bib233","first-page":"147","article-title":"Tachosil application after laparoscopic myomectomy: a prospective randomized trial","volume":"23","author":"Maggiore","year":"2011","journal-title":"Ital J Gynaecol Obstet"},{"key":"key20161223072506546_ref1-bib234","first-page":"571","article-title":"Adhesion-prevention effects of fibrin sealants after laparoscopic myomectomy as determined by second-look laparoscopy: a prospective, randomized, controlled study","volume":"50","author":"Takeuchi","year":"2005","journal-title":"J Reprod Med"},{"key":"key20161223072506546_ref1-bib235","doi-asserted-by":"publisher","first-page":"438","DOI":"10.1002\/nau.20754","article-title":"Fibrin glue versus martius flap interpositioning in the repair of complicated obstetric vesicovaginal fistula. A prospective multi-institution randomized trial","volume":"28","author":"Safan","year":"2009","journal-title":"Neurourol Urodyn"},{"key":"key20161223072506546_ref1-bib236","doi-asserted-by":"publisher","first-page":"347","DOI":"10.1097\/01.brs.0000167820.54413.8e","article-title":"The effect of autologous fibrin tissue adhesive on postoperative cerebrospinal fluid leak in spinal cord surgery: a randomized controlled trial","volume":"30","author":"Nakamura","year":"2005","journal-title":"Spine"},{"key":"key20161223072506546_ref1-bib237","doi-asserted-by":"publisher","first-page":"735","DOI":"10.3171\/2014.6.JNS131917","article-title":"Risk factors for postoperative CSF leakage after elective craniotomy and the efficacy of fleece-bound tissue sealing against dural suturing alone: a randomized controlled trial","volume":"121","author":"Hutter","year":"2014","journal-title":"J Neurosurg"},{"key":"key20161223072506546_ref1-bib238","doi-asserted-by":"publisher","first-page":"439","DOI":"10.1159\/000072229","article-title":"A comparison of the haemostatic effect of Vivostat patient-derived fibrin sealant with oxidised cellulose (Surgicel) in multiple surgical procedures","volume":"35","author":"Hanks","year":"2003","journal-title":"Eur Surg Res"},{"key":"key20161223072506546_ref1-bib239","doi-asserted-by":"publisher","first-page":"70","DOI":"10.1016\/j.jamcollsurg.2014.09.019","article-title":"The FINISH-3 trial: a phase 3, international, randomized, single-blind, controlled trial of topical fibrocaps in intraoperative surgical hemostasis","volume":"220","author":"Bochicchio","year":"2015","journal-title":"J Am Coll Surg"},{"key":"key20161223072506546_ref1-bib240","doi-asserted-by":"publisher","first-page":"679","DOI":"10.1016\/j.jss.2014.12.011","article-title":"Fibrocaps for surgical hemostasis: two randomized, controlled phase II trials","volume":"194","author":"Verhoef","year":"2015","journal-title":"J Surg Res"},{"key":"key20161223072506546_ref1-bib241","doi-asserted-by":"publisher","first-page":"385","DOI":"10.1016\/j.jamcollsurg.2013.02.036","article-title":"A prospective, randomized, controlled trial of the efficacy and safety of fibrin pad as an adjunct to control soft tissue bleeding during abdominal, retroperitoneal, pelvic, and thoracic surgery","volume":"217","author":"Fischer","year":"2013","journal-title":"J Am Coll Surg"},{"key":"key20161223072506546_ref1-bib242","doi-asserted-by":"publisher","first-page":"97","DOI":"10.3810\/pgm.2014.01.2729","article-title":"Long-term comparison of fibrin tissue glue and vicryl suture in conjunctival autografting for pterygium surgery","volume":"126","author":"Cagatay","year":"2014","journal-title":"Postgrad Med"},{"key":"key20161223072506546_ref1-bib243","doi-asserted-by":"publisher","first-page":"105","DOI":"10.1159\/000112627","article-title":"Comparison of fibrin sealant and sutures for conjunctival autograft fixation in pterygium surgery: one-year follow-up","volume":"222","author":"Jiang","year":"2008","journal-title":"Ophthalmologica"},{"key":"key20161223072506546_ref1-bib244","doi-asserted-by":"publisher","first-page":"688","DOI":"10.1097\/IAE.0b013e3181cdf398","article-title":"Fibrin glue-assisted conjunctival closure in pars plana vitrectomy where conjunctival closure with a suture would be difficult","volume":"30","author":"Choi","year":"2010","journal-title":"Retina"},{"key":"key20161223072506546_ref1-bib245","doi-asserted-by":"publisher","first-page":"46","DOI":"10.1016\/j.soard.2009.03.002","article-title":"Fibrin sealant associated with increased body temperature and leukocytosis after laparoscopic gastric bypass","volume":"6","author":"Efthimiou","year":"2010","journal-title":"Surg Obes Relat Dis"},{"key":"key20161223072506546_ref1-bib246","doi-asserted-by":"publisher","first-page":"1052","DOI":"10.1007\/s11695-014-1204-3","article-title":"Incidence of gastrojejunostomy stricture in laparoscopic Roux-en-Y gastric bypass using an autologous fibrin sealant","volume":"24","author":"Ibele","year":"2014","journal-title":"Obes Surg"},{"key":"key20161223072506546_ref1-bib247","first-page":"1544","article-title":"Does fibrin glue prevent biliary and pancreatic fistula after surgical resection?","volume":"59","author":"Nanashima","year":"2012","journal-title":"Hepatogastroenterology"},{"key":"key20161223072506546_ref1-bib248","doi-asserted-by":"publisher","first-page":"306","DOI":"10.1016\/0007-1226(94)90087-6","article-title":"Face lifts and sprayed fibrin glue: an outcome analysis of 200 patients","volume":"47","author":"Marchac","year":"1994","journal-title":"Br J Plast Surg"},{"key":"key20161223072506546_ref1-bib249","doi-asserted-by":"publisher","first-page":"378","DOI":"10.1093\/icvts\/ivt089","article-title":"Simple adaptations of surgical technique to critically reduce the risk of postoperative sternal complications in patients receiving bilateral internal thoracic arteries","volume":"17","author":"Sakic","year":"2013","journal-title":"Interact Cardiovasc Thorac Surg"},{"key":"key20161223072506546_ref1-bib250","doi-asserted-by":"publisher","DOI":"10.1186\/1745-6215-11-109","article-title":"Comparison of the collagen haemostat Sangustop versus a carrier-bound fibrin sealant during liver resection; ESSCALIVER-Study","volume":"11","author":"Moench","year":"2010","journal-title":"Trials"},{"key":"key20161223072506546_ref1-bib251","first-page":"411","article-title":"Fibrin glue does not reduce lymphorrhoea after axillary lymph node dissection","volume":"49","author":"Vaxman","year":"1995","journal-title":"Annales de Chirurgie"},{"key":"key20161223072506546_ref1-bib252","doi-asserted-by":"publisher","first-page":"169","DOI":"10.1016\/S0002-9394(99)80087-7","article-title":"Efficacy and safety of the ProTek (Vifilcon A) therapeutic soft contact lens after photorefractive keratectomy","volume":"125","author":"Lim-Bon-Siong","year":"1998","journal-title":"Am J Ophthalmol"},{"key":"key20161223072506546_ref1-bib253","volume-title":"Wong\u2019s Essentials of Pediatric Nursing","author":"Wong","year":"2001","edition":"6th edn."},{"key":"key20161223072506546_ref1-bib254","volume-title":"Sprayable Fibrin Sealants (Evicel, Tisseel and Artiss): Updated Guidance","author":"MHRA","year":"2013"},{"key":"key20161223072506546_ref1-bib255","volume-title":"Fibrinogen-Containing Solutions for Sealant Authorised For Administration by Spray Application","author":"EMA","year":"2013"},{"key":"key20161223072506546_ref1-bib256","volume-title":"Risk of Life-Threatening Air or Gas Embolism with the Use of Spray Devices Employing Pressure Regulator to Administer Fibrin Sealants (Baxter Healthcare Corporation)","author":"FDA","year":"2009"},{"key":"key20161223072506546_ref1-bib257","volume-title":"Pediatric Safety and Utilization Review for the Pediatric Advisory Committee (PAC) Meeting","author":"FDA","year":"2014"},{"key":"key20161223072506546_ref1-bib258","volume-title":"MDR Analysis of Tisseel Fibrin Sealant Delivery Systems","author":"FDA","year":"2014"},{"key":"key20161223072506546_ref1-bib259","doi-asserted-by":"publisher","first-page":"1961","DOI":"10.1007\/s00464-007-9355-0","article-title":"Laparoscopic repair of inguinal hernias using an intraperitoneal onlay mesh technique and a Parietex composite mesh fixed with fibrin glue (Tissucol). Personal technique and preliminary results","volume":"21","author":"Olmi","year":"2007","journal-title":"Surg Endosc"},{"key":"key20161223072506546_ref1-bib260","doi-asserted-by":"publisher","first-page":"1537","DOI":"10.1002\/bjs.7646","article-title":"Randomized clinical trial of fibrin sealant versus titanium tacks for mesh fixation in laparoscopic umbilical hernia repair","volume":"98","author":"Eriksen","year":"2011","journal-title":"Br J Surg"},{"key":"key20161223072506546_ref1-bib261","first-page":"609","article-title":"Application of cryoprecipitate as a hematostatic glue","volume":"39","author":"Shiono","year":"1998","journal-title":"J Cardiovasc Surg"}],"container-title":["Health Technology Assessment"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.journalslibrary.nihr.ac.uk\/publications\/hta20940\/hta20940.xml","content-type":"unspecified","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/njl-admin.nihr.ac.uk\/document\/download\/2002562","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/www.journalslibrary.nihr.ac.uk\/publications\/hta20940\/hta20940.xml","content-type":"text\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/njl-admin.nihr.ac.uk\/document\/download\/2009505","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2024,6,21]],"date-time":"2024-06-21T15:10:38Z","timestamp":1718982638000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.journalslibrary.nihr.ac.uk\/hta\/hta20940\/"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2016,12]]},"references-count":261,"journal-issue":{"issue":"94","published-online":{"date-parts":[[2016,12]]}},"alternative-id":["10.3310\/hta20940"],"URL":"https:\/\/doi.org\/10.3310\/hta20940","relation":{},"ISSN":["1366-5278","2046-4924"],"issn-type":[{"value":"1366-5278","type":"print"},{"value":"2046-4924","type":"electronic"}],"subject":[],"published":{"date-parts":[[2016,12]]},"assertion":[{"value":"This content has been made freely available to all.","name":"free","label":"Free to read"}]}}