{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,13]],"date-time":"2026-10-13T15:38:21Z","timestamp":1791905901684,"version":"4.3.4"},"reference-count":151,"publisher":"National Institute for Health and Care Research","issue":"39","license":[{"start":{"date-parts":[[2020,8,1]],"date-time":"2020-08-01T00:00:00Z","timestamp":1596240000000},"content-version":"unspecified","delay-in-days":0,"URL":"http:\/\/www.nationalarchives.gov.uk\/doc\/non-commercial-government-licence\/non-commercial-government-licence.htm"}],"funder":[{"DOI":"10.13039\/501100000664","name":"Health Technology Assessment programme","doi-asserted-by":"publisher","award":["NIHR127519"],"award-info":[{"award-number":["NIHR127519"]}],"id":[{"id":"10.13039\/501100000664","id-type":"DOI","asserted-by":"publisher"}]}],"content-domain":{"domain":["journalslibrary.nihr.ac.uk"],"crossmark-restriction":false},"short-container-title":["Health Technol Assess"],"abstract":"<jats:sec id=\"abs1-1\">\n                  <jats:title>Background<\/jats:title>\n                  <jats:p>Patients with low estimated glomerular filtration rates may be at higher risk of post-contrast acute kidney injury following contrast-enhanced computed tomography imaging. Point-of-care devices allow rapid measurement of estimated glomerular filtration rates for patients referred without a recent estimated glomerular filtration rate result.<\/jats:p>\n               <\/jats:sec>\n               <jats:sec id=\"abs1-2\">\n                  <jats:title>Objectives<\/jats:title>\n                  <jats:p>To assess the clinical effectiveness and cost-effectiveness of point-of-care creatinine tests for outpatients without a recent estimated glomerular filtration rate measurement who need contrast-enhanced computed tomography imaging.<\/jats:p>\n               <\/jats:sec>\n               <jats:sec id=\"abs1-3\">\n                  <jats:title>Methods<\/jats:title>\n                  <jats:p>Three systematic reviews of test accuracy, implementation and clinical outcomes, and economic analyses were carried out. Bibliographic databases were searched from inception to November 2018. Studies comparing the accuracy of point-of-care creatinine tests with laboratory reference tests to assess kidney function in adults in a non-emergency setting and studies reporting implementation and clinical outcomes were included. Risk of bias of diagnostic accuracy studies was assessed using a modified version of the Quality Assessment of Diagnostic Accuracy Studies 2 (QUADAS-2) tool. Probabilities of individuals having their estimated glomerular filtration rates correctly classified were estimated within a Bayesian framework and pooled using a fixed-effects model. A de novo probabilistic decision tree cohort model was developed to characterise the decision problem from an NHS and a Personal Social Services perspective. A range of alternative point-of-care testing approaches were considered. Scenario analyses were conducted.<\/jats:p>\n               <\/jats:sec>\n               <jats:sec id=\"abs1-4\">\n                  <jats:title>Results<\/jats:title>\n                  <jats:p>Fifty-four studies were included in the clinical reviews. Twelve studies reported diagnostic accuracy for estimated glomerular filtration rates; half were rated as being at low risk of bias, but there were applicability concerns for most. i-STAT (Abbott Point of Care, Inc., Princeton, NJ, USA) and ABL (Radiometer Ltd, Crawley, UK) devices had higher probabilities of correctly classifying individuals in the same estimated glomerular filtration rate categories as the reference laboratory test than StatSensor<jats:sup>\u00ae<\/jats:sup> devices (Nova Biomedical, Runcorn, UK). There was limited evidence for epoc<jats:sup>\u00ae<\/jats:sup> (Siemens Healthineers AG, Erlangen, Germany) and Piccolo Xpress<jats:sup>\u00ae<\/jats:sup> (Abaxis, Inc., Union City, CA, USA) devices and no studies of DRI-CHEM NX 500 (Fujifilm Corporation, Tokyo, Japan). The review of implementation and clinical outcomes included six studies showing practice variation in the management decisions when a point-of-care device indicated an abnormal estimated glomerular filtration rate. The review of cost-effectiveness evidence identified no relevant studies. The de novo decision model that was developed included a total of 14 strategies. Owing to limited data, the model included only i-STAT, ABL800 FLEX and StatSensor. In the base-case analysis, the cost-effective strategy appeared to be a three-step testing sequence involving initially screening all individuals for risk factors, point-of-care testing for those individuals with at least one risk factor, and including a final confirmatory laboratory test for individuals with a point-of-care-positive test result. Within this testing approach, the specific point-of-care device with the highest net benefit was i-STAT, although differences in net benefit with StatSensor were very small.<\/jats:p>\n               <\/jats:sec>\n               <jats:sec id=\"abs1-5\">\n                  <jats:title>Limitations<\/jats:title>\n                  <jats:p>There was insufficient evidence for patients with estimated glomerular filtration rates &lt;\u200930\u2009ml\/minute\/1.73\u2009m<jats:sup>2<\/jats:sup>, and on the full potential health impact of delayed or rescheduled computed tomography scans or the use of alternative imaging modalities.<\/jats:p>\n               <\/jats:sec>\n               <jats:sec id=\"abs1-6\">\n                  <jats:title>Conclusions<\/jats:title>\n                  <jats:p>A three-step testing sequence combining a risk factor questionnaire with a point-of-care test and confirmatory laboratory testing appears to be a cost-effective use of NHS resources compared with current practice. The risk of contrast causing acute kidney injury to patients with an estimated glomerular filtration rate of &lt;\u200930\u2009ml\/minute\/1.73\u2009m<jats:sup>2<\/jats:sup> is uncertain. Cost-effectiveness of point-of-care testing appears largely driven by the potential of point-of-care tests to minimise delays within the current computed tomography pathway.<\/jats:p>\n               <\/jats:sec>\n               <jats:sec id=\"abs1-7\">\n                  <jats:title>Future work<\/jats:title>\n                  <jats:p>Studies evaluating the impact of risk-stratifying questionnaires on workflow outcomes in computed tomography patients without recent estimated glomerular filtration rate results are needed.<\/jats:p>\n               <\/jats:sec>\n               <jats:sec id=\"abs1-8\">\n                  <jats:title>Study registration<\/jats:title>\n                  <jats:p>This study is registered as PROSPERO CRD42018115818.<\/jats:p>\n               <\/jats:sec>\n               <jats:sec id=\"abs1-9\">\n                  <jats:title>Funding<\/jats:title>\n                  <jats:p>This project was funded by the National Institute for Health Research (NIHR) Health Technology Assessment programme and will be published in full in <jats:italic>Health Technology Assessment<\/jats:italic>; Vol. 24, No. 39. See the NIHR Journals Library website for further project information.<\/jats:p>\n               <\/jats:sec>","DOI":"10.3310\/hta24390","type":"journal-article","created":{"date-parts":[[2020,8,25]],"date-time":"2020-08-25T13:32:11Z","timestamp":1598362331000},"page":"1-248","update-policy":"https:\/\/doi.org\/10.3310\/crossmarkpolicy","source":"Crossref","is-referenced-by-count":20,"title":["Point-of-care creatinine tests to assess kidney function for outpatients requiring contrast-enhanced CT imaging: systematic reviews and economic evaluation"],"prefix":"10.3310","volume":"24","author":[{"ORCID":"https:\/\/orcid.org\/0000-0002-5937-1493","authenticated-orcid":true,"given":"Mark","family":"Corbett","sequence":"first","affiliation":[{"name":"Centre for Reviews and Dissemination (CRD), University of York, York, UK"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-0528-4773","authenticated-orcid":true,"given":"Ana","family":"Duarte","sequence":"additional","affiliation":[{"name":"Centre for Health Economics (CHE), University of York, York, UK"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-4569-5136","authenticated-orcid":true,"given":"Alexis","family":"Llewellyn","sequence":"additional","affiliation":[{"name":"Centre for Reviews and Dissemination (CRD), University of York, York, UK"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-8293-3466","authenticated-orcid":true,"given":"James","family":"Altunkaya","sequence":"additional","affiliation":[{"name":"Centre for Health Economics (CHE), University of York, York, UK"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-2338-6869","authenticated-orcid":true,"given":"Melissa","family":"Harden","sequence":"additional","affiliation":[{"name":"Centre for Reviews and Dissemination (CRD), University of York, York, UK"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-1924-3718","authenticated-orcid":true,"given":"Martine","family":"Harris","sequence":"additional","affiliation":[{"name":"Mid Yorkshire Hospitals NHS Trust, Pinderfields Hospital, Wakefield, UK"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-5750-3691","authenticated-orcid":true,"given":"Simon","family":"Walker","sequence":"additional","affiliation":[{"name":"Centre for Health Economics (CHE), University of York, York, UK"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-7268-2560","authenticated-orcid":true,"given":"Stephen","family":"Palmer","sequence":"additional","affiliation":[{"name":"Centre for Health Economics (CHE), University of York, York, UK"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-2172-0221","authenticated-orcid":true,"given":"Sofia","family":"Dias","sequence":"additional","affiliation":[{"name":"Centre for Reviews and Dissemination (CRD), University of York, York, UK"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-1579-8513","authenticated-orcid":true,"given":"Marta","family":"Soares","sequence":"additional","affiliation":[{"name":"Centre for Health Economics (CHE), University of York, York, UK"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"6221","published-online":{"date-parts":[[2020,8]]},"reference":[{"key":"key20200824111041599_ref1-bib1","unstructured":"Committee on Medical Aspects of Radiation in the Environment (COMARE). Sixteenth Report. Patient Radiation Dose Issues Resulting from the Use of CT in the UK. London: Public Health England; 2014."},{"key":"key20200824111041599_ref1-bib2","doi-asserted-by":"publisher","first-page":"104","DOI":"10.1007\/s00134-017-4950-6","article-title":"Contrast-associated acute kidney injury is a myth: yes","volume":"44","author":"Ehrmann","year":"2018","journal-title":"Intensive Care Med"},{"key":"key20200824111041599_ref1-bib3","doi-asserted-by":"publisher","first-page":"107","DOI":"10.1007\/s00134-017-5015-6","article-title":"Contrast-associated acute kidney injury is a myth: No","volume":"44","author":"Weisbord","year":"2018","journal-title":"Intensive Care Med"},{"key":"key20200824111041599_ref1-bib4","doi-asserted-by":"publisher","first-page":"110","DOI":"10.1007\/s00134-017-4970-2","article-title":"Contrast-associated acute kidney injury is a myth: we are not sure","volume":"44","author":"Kashani","year":"2018","journal-title":"Intensive Care Med"},{"key":"key20200824111041599_ref1-bib5","doi-asserted-by":"publisher","first-page":"627","DOI":"10.1148\/radiol.2015151486","article-title":"Controversies in contrast material-induced acute kidney injury: closing in on the truth?","volume":"277","author":"McDonald","year":"2015","journal-title":"Radiology"},{"key":"key20200824111041599_ref1-bib6","unstructured":"ACR Committee on Drugs and Contrast Media. ACR Manual on Contrast Media: Version 10.3 2018. Reston, VA: American College of Radiology; 2018."},{"key":"key20200824111041599_ref1-bib7","doi-asserted-by":"publisher","first-page":"604","DOI":"10.7326\/0003-4819-150-9-200905050-00006","article-title":"A new equation to estimate glomerular filtration rate","volume":"150","author":"Levey","year":"2009","journal-title":"Ann Intern Med"},{"key":"key20200824111041599_ref1-bib8","doi-asserted-by":"publisher","first-page":"461","DOI":"10.7326\/0003-4819-130-6-199903160-00002","article-title":"A more accurate method to estimate glomerular filtration rate from serum creatinine: a new prediction equation. Modification of Diet in Renal Disease Study Group","volume":"130","author":"Levey","year":"1999","journal-title":"Ann Intern Med"},{"key":"key20200824111041599_ref1-bib9","doi-asserted-by":"publisher","first-page":"1300","DOI":"10.1093\/ndt\/gfv220","article-title":"Selecting a strategy for prevention of contrast-induced nephropathy in clinical practice: an evaluation of different clinical practice guidelines using the AGREE tool","volume":"30","author":"Vanommeslaeghe","year":"2015","journal-title":"Nephrol Dial Transplant"},{"key":"key20200824111041599_ref1-bib10","unstructured":"European Society of Urogenital Radiology (ESUR). ESUR Guidelines on Contrast Agents v10.0. ESUR; 2018. URL: https:\/\/www.esur-cm.org\/ (accessed 28 February 2019)."},{"key":"key20200824111041599_ref1-bib11","unstructured":"The Royal Australian and New Zealand College of Radiologists. Iodinated Contrast Media Guideline V2.3. Sydney, NSW: The Royal Australian and New Zealand College of Radiologists; 2018."},{"key":"key20200824111041599_ref1-bib12","doi-asserted-by":"publisher","first-page":"20160077","DOI":"10.1259\/bjr.20160077","article-title":"Strategies for assessing renal function prior to outpatient contrast-enhanced CT: a UK survey","volume":"89","author":"Harris","year":"2016","journal-title":"Br J Radiol"},{"key":"key20200824111041599_ref1-bib13","doi-asserted-by":"publisher","first-page":"1047","DOI":"10.1016\/j.crad.2017.07.002","article-title":"RCR audit of compliance with UK guidelines for the prevention and detection of acute kidney injury in adult patients undergoing iodinated contrast media injections for CT","volume":"72","author":"Cope","year":"2017","journal-title":"Clin Radiol"},{"key":"key20200824111041599_ref1-bib14","doi-asserted-by":"publisher","first-page":"780","DOI":"10.1007\/s00330-013-3065-x","article-title":"Can a structured questionnaire identify patients with reduced renal function?","volume":"24","author":"Azzouz","year":"2014","journal-title":"Eur Radiol"},{"key":"key20200824111041599_ref1-bib15","volume-title":"Point-of-Care Creatinine Testing for the Detection and Monitoring of Chronic Kidney Disease","author":"Gbinigie","year":"2014"},{"key":"key20200824111041599_ref1-bib16","doi-asserted-by":"publisher","first-page":"475","DOI":"10.1373\/clinchem.2017.276683","article-title":"Systematic review and metaanalysis comparing the bias and accuracy of the modification of diet in renal disease and chronic kidney disease epidemiology collaboration equations in community-based populations","volume":"64","author":"McFadden","year":"2018","journal-title":"Clin Chem"},{"key":"key20200824111041599_ref1-bib17","unstructured":"Abbott. i-STAT Alinity. Princeton, NJ: Abbott Point of Care Inc.; 2019. URL: www.pointofcare.abbott\/int\/en\/offerings\/istat-alinity (accessed 20 March 2019)."},{"key":"key20200824111041599_ref1-bib18","doi-asserted-by":"publisher","first-page":"307","DOI":"10.1016\/S0140-6736(86)90837-8","article-title":"Statistical methods for assessing agreement between two methods of clinical measurement","volume":"1","author":"Bland","year":"1986","journal-title":"Lancet"},{"key":"key20200824111041599_ref1-bib19","first-page":"1","article-title":"KDIGO 2012 clinical practice guideline for the evaluation and management of chronic kidney disease","volume":"3","author":"Kidney Disease: Improving Global Outcomes (KDIGO)","year":"2013","journal-title":"Kidney Int Suppl"},{"key":"key20200824111041599_ref1-bib20","unstructured":"National Institute for Health and Care Excellence (NICE). Chronic Kidney Disease in Adults: Assessment and Management. Clinical Guideline [CG182]. London: NICE; 2014. URL: www.nice.org.uk\/guidance\/cg182\/chapter\/1-Recommendations (accessed 21 May 2019)."},{"key":"key20200824111041599_ref1-bib21","volume-title":"The BUGS Book","author":"Lunn","year":"2013"},{"key":"key20200824111041599_ref1-bib22","doi-asserted-by":"publisher","first-page":"3049","DOI":"10.1002\/sim.3680","article-title":"The BUGS project: evolution, critique and future directions","volume":"28","author":"Lunn","year":"2009","journal-title":"Stat Med"},{"key":"key20200824111041599_ref1-bib23","volume-title":"Bayesian Data Analysis","author":"Gelman","year":"2014"},{"key":"key20200824111041599_ref1-bib24","doi-asserted-by":"publisher","first-page":"340","DOI":"10.1198\/000313008X370843","article-title":"Displaying uncertainty with shading","volume":"62","author":"Jackson","year":"2008","journal-title":"Am Stat"},{"key":"key20200824111041599_ref1-bib25","doi-asserted-by":"publisher","first-page":"434","DOI":"10.1080\/10618600.1998.10474787","article-title":"General methods for monitoring convergence of iterative simulations","volume":"7","author":"Brooks","year":"1998","journal-title":"J Comput Graph Stat"},{"key":"key20200824111041599_ref1-bib26","doi-asserted-by":"publisher","first-page":"457","DOI":"10.1214\/ss\/1177011136","article-title":"Inference from iterative simulation using multiple sequences","volume":"7","author":"Gelman","year":"1992","journal-title":"Stat Sci"},{"key":"key20200824111041599_ref1-bib27","first-page":"A192","article-title":"Comparison of whole blood and serum creatinine and estimated glomerular filtration rate for screening of at-risk patients prior to radiographic procedures","volume":"1","author":"Botz","year":"2013","journal-title":"Clin Chem"},{"key":"key20200824111041599_ref1-bib28","doi-asserted-by":"publisher","first-page":"e36","DOI":"10.1097\/QAI.0000000000001613","article-title":"Clinic-based evaluation of a point-of-care creatinine assay to screen for renal impairment among HIV-positive patients receiving tenofovir disoproxil fumarate","volume":"77","author":"Dorward","year":"2018","journal-title":"J Acquir Immune Defic Syndr"},{"key":"key20200824111041599_ref1-bib29","doi-asserted-by":"publisher","first-page":"5670384","DOI":"10.1155\/2017\/5670384","article-title":"Assessing the risk of contrast-induced nephropathy using a finger stick analysis in recalls from breast screening: the CINFIBS Explorative Study","volume":"2017","author":"Houben","year":"2017","journal-title":"Contrast Media Mol Imaging"},{"key":"key20200824111041599_ref1-bib30","doi-asserted-by":"publisher","first-page":"3503","DOI":"10.3892\/etm.2017.4389","article-title":"StatSensor-i point-of-care creatinine analyzer may identify patients at high-risk of contrast-induced nephropathy","volume":"13","author":"Inoue","year":"2017","journal-title":"Exp Ther Med"},{"key":"key20200824111041599_ref1-bib31","doi-asserted-by":"publisher","first-page":"920","DOI":"10.1309\/AJCPTE5FEY0VCGOZ","article-title":"Comparison of three whole blood creatinine methods for estimation of glomerular filtration rate before radiographic contrast administration","volume":"132","author":"Korpi-Steiner","year":"2009","journal-title":"Am J Clin Pathol"},{"key":"key20200824111041599_ref1-bib32","volume-title":"Screening for Chronic Kidney Disease (CKD) in a High Risk Population Using a Point of Care Instrument for Creatinine Measurement: a Community Based Study (The Bellville South Africa Study","author":"Krige","year":"2017"},{"key":"key20200824111041599_ref1-bib33","doi-asserted-by":"publisher","first-page":"201","DOI":"10.1016\/j.cca.2006.09.024","article-title":"Evaluation of the IRMA TRUpoint and i-STAT creatinine assays","volume":"377","author":"Nichols","year":"2007","journal-title":"Clin Chim Acta"},{"key":"key20200824111041599_ref1-bib34","first-page":"ii100","article-title":"Validation of serum creatinine (SCR) measurement with the point-of-care testing (POCT) device i-STAT in a Mexican government sponsored-chronic kidney disease (CKD) screening program","volume":"27","author":"Obrador","year":"2012","journal-title":"Nephrol Dial Transplant"},{"key":"key20200824111041599_ref1-bib35","first-page":"A101","article-title":"Creatinine can be measured at the point-of-care","volume":"13","author":"Shephard","year":"2008","journal-title":"Nephrology"},{"key":"key20200824111041599_ref1-bib36","doi-asserted-by":"publisher","first-page":"1113","DOI":"10.1515\/CCLM.2010.238","article-title":"Assessment of the Nova StatSensor whole blood point-of-care creatinine analyzer for the measurement of kidney function in screening for chronic kidney disease","volume":"48","author":"Shephard","year":"2010","journal-title":"Clin Chem Lab Med"},{"key":"key20200824111041599_ref1-bib37","doi-asserted-by":"publisher","first-page":"1269","DOI":"10.1515\/cclm-2018-0128","article-title":"Point-of-care creatinine testing for kidney function measurement prior to contrast-enhanced diagnostic imaging: evaluation of the performance of three systems for clinical utility","volume":"56","author":"Snaith","year":"2018","journal-title":"Clin Chem Lab Med"},{"key":"key20200824111041599_ref1-bib38","doi-asserted-by":"publisher","first-page":"82","DOI":"10.1016\/j.ejrad.2019.01.007","article-title":"Point of care creatinine testing in diagnostic imaging: a feasibility study within the outpatient computed tomography setting","volume":"112","author":"Snaith","year":"2019","journal-title":"Eur J Radiol"},{"key":"key20200824111041599_ref1-bib39","doi-asserted-by":"publisher","first-page":"e0204614","DOI":"10.1371\/journal.pone.0204614","article-title":"Unadjusted point of care creatinine results overestimate acute kidney injury incidence during field testing in Guatemala","volume":"13","author":"Griffin","year":"2018","journal-title":"PLOS ONE"},{"key":"key20200824111041599_ref1-bib40","volume-title":"Evaluation of the StatSensor Whole Blood Creatinine Monitoring System for Screening Patients in the Radiology Department","author":"Hamza"},{"key":"key20200824111041599_ref1-bib41","doi-asserted-by":"publisher","first-page":"328","DOI":"10.4329\/wjr.v4.i7.328","article-title":"Evaluation of a handheld creatinine measurement device for real-time determination of serum creatinine in radiology departments","volume":"4","author":"Haneder","year":"2012","journal-title":"World J Radiol"},{"key":"key20200824111041599_ref1-bib42","doi-asserted-by":"publisher","first-page":"e0122433","DOI":"10.1371\/journal.pone.0122433","article-title":"Evaluation of the Nova StatSensor\u00ae Xpress\u2122 Creatinine point-of-care handheld analyzer","volume":"10","author":"Kosack","year":"2015","journal-title":"PLOS ONE"},{"key":"key20200824111041599_ref1-bib43","volume-title":"Management of the Prevention of Kidney Injury in Patients at Risk of Renal Failure by StatSensor Blood Creatinine Monitoring System: Evaluation of Method","author":"McGough"},{"key":"key20200824111041599_ref1-bib44","doi-asserted-by":"publisher","first-page":"456","DOI":"10.1016\/j.clinbiochem.2015.01.005","article-title":"Chronic kidney disease prevalence in Rivas, Nicaragua: use of a field device for creatinine measurement","volume":"48","author":"Minnings","year":"2015","journal-title":"Clin Biochem"},{"key":"key20200824111041599_ref1-bib45","first-page":"S1525","article-title":"Evaluation and performance of the nova StatSensor creatinine point-of-care monitoring system","volume":"1","author":"Rensburg","year":"2014","journal-title":"Clin Chem Lab Med"},{"key":"key20200824111041599_ref1-bib46","doi-asserted-by":"publisher","first-page":"25","DOI":"10.1097\/POC.0b013e3181d2d8a5","article-title":"Validation of the StatSensor creatinine meter for testing blood before contrast computed tomography studies","volume":"9","author":"Aumatell","year":"2010","journal-title":"Point Care"},{"key":"key20200824111041599_ref1-bib47","doi-asserted-by":"publisher","first-page":"72","DOI":"10.1097\/POC.0000000000000093","article-title":"Investigation of falsely decreased creatinine results observed from the Abbott I-STAT point-of-care device in use for testing specimens from ambulatory oncology patients","volume":"15","author":"Bahar","year":"2016","journal-title":"Point Care"},{"key":"key20200824111041599_ref1-bib48","doi-asserted-by":"publisher","first-page":"48","DOI":"10.1034\/j.1399-0012.17.s9.9.x","article-title":"Point-of-care testing in an organ procurement organization donor management setting","volume":"17","author":"Baier","year":"2003","journal-title":"Clin Transplant"},{"key":"key20200824111041599_ref1-bib49","first-page":"A165","article-title":"Comparison of whole blood creatinine measurement to serum creatinine measurements in renal dose calculations","volume":"58","author":"Bender","year":"2012","journal-title":"Clin Chem"},{"key":"key20200824111041599_ref1-bib50","doi-asserted-by":"publisher","first-page":"A030","DOI":"10.1093\/ajcp\/143.suppl1.031","article-title":"Hydroxyurea interference in point-of-care creatinine and glucose measurements","volume":"1","author":"Betman","year":"2015","journal-title":"Am J Clin Pathol"},{"key":"key20200824111041599_ref1-bib51","volume-title":"Comparison of Creatinine Concentration in Serum, Plasma and Whole Blood on Different Routinely Used Analysers","author":"Bobilewicz","year":"2008"},{"key":"key20200824111041599_ref1-bib52","doi-asserted-by":"publisher","first-page":"24","DOI":"10.1016\/j.plabm.2017.07.003","article-title":"Validation of capillary blood analysis and capillary testing mode on the epoc point of care system","volume":"9","author":"Cao","year":"2017","journal-title":"Pract Lab Med"},{"key":"key20200824111041599_ref1-bib53","doi-asserted-by":"publisher","first-page":"S138","DOI":"10.1016\/j.preghy.2018.08.410","article-title":"Evaluation of the StatSensor Xpress for the point of care determination of capillary creatinine concentration in a pregnant population","volume":"13","author":"Cory","year":"2018","journal-title":"Pregnancy Hypertens"},{"key":"key20200824111041599_ref1-bib54","doi-asserted-by":"publisher","first-page":"47","DOI":"10.1258\/acb.2012.012081","article-title":"Which point-of-care creatinine analyser for radiology: direct comparison of the i-Stat and StatStrip creatinine methods with different sample types","volume":"50","author":"Dimeski","year":"2013","journal-title":"Ann Clin Biochem"},{"key":"key20200824111041599_ref1-bib55","first-page":"33","article-title":"Comparison of Some Characteristics in Results of Four Analytical Systems for 12 Basic Biochemical Analytes","volume":"16","author":"Dohnal","year":"2008","journal-title":"Klini Biochemi Metabol"},{"key":"key20200824111041599_ref1-bib56","doi-asserted-by":"publisher","first-page":"178","DOI":"10.1159\/000045982","article-title":"Evaluation of i-STAT creatinine assay","volume":"88","author":"Gault","year":"2001","journal-title":"Nephron"},{"key":"key20200824111041599_ref1-bib57","first-page":"A135","article-title":"Under-estimation of plasma creatinine using iSTAT point-of-care analyzer: impact on carboplatin dosing in an academic cancer center","volume":"1","author":"Georgievskaya","year":"2011","journal-title":"Clin Chem"},{"key":"key20200824111041599_ref1-bib58","volume-title":"Comparison of Whole Blood Versus Plasma Creatinine Measurements on the ABL800 FLEX and Olympus AU5431 Analyzer (Modified Jaffe Method)","author":"Janetto","year":"2006"},{"key":"key20200824111041599_ref1-bib59","doi-asserted-by":"publisher","first-page":"88","DOI":"10.1016\/j.cca.2011.05.006","article-title":"Evaluation of rapid point-of-care creatinine testing in the radiology service of a large academic medical center: impact on clinical operations and patient disposition","volume":"413","author":"Lee-Lewandrowski","year":"2012","journal-title":"Clin Chim Acta"},{"key":"key20200824111041599_ref1-bib60","volume-title":"Sodium, Potassium and Creatinine Result Level Comparison Between Point-of-Care Analyser and Core Laboratory Automatic Analyser","author":"Lehtonen","year":"2013"},{"key":"key20200824111041599_ref1-bib61","first-page":"S225","article-title":"Accuracy of i-STAT point-of-care creatinine measurements in outpatient chemotherapy patients: a direct comparison to laboratory based methods","volume":"62","author":"Mahlow","year":"2016","journal-title":"Clin Chem"},{"key":"key20200824111041599_ref1-bib62","doi-asserted-by":"publisher","first-page":"187","DOI":"10.1007\/s11604-010-0536-8","article-title":"Assessing renal function with a rapid, handy, point-of-care whole blood creatinine meter before using contrast materials","volume":"29","author":"Morita","year":"2011","journal-title":"Jpn J Radiol"},{"key":"key20200824111041599_ref1-bib63","doi-asserted-by":"publisher","first-page":"81","DOI":"10.1016\/j.dib.2017.11.006","article-title":"Data from the analytical performance of the Abaxis Piccolo Xpress point of care analyzer in whole blood, serum, and plasma","volume":"16","author":"Murata","year":"2018","journal-title":"Data Brief"},{"key":"key20200824111041599_ref1-bib64","doi-asserted-by":"publisher","first-page":"79","DOI":"10.1016\/j.cca.2013.11.033","article-title":"Comparison of estimated glomerular filtration rates using creatinine values generated by iSTAT and Cobas 6000","volume":"429","author":"Naugler","year":"2014","journal-title":"Clin Chim Acta"},{"key":"key20200824111041599_ref1-bib65","doi-asserted-by":"publisher","first-page":"430","DOI":"10.3343\/kjlm.2009.29.5.430","article-title":"Performance evaluation of the Piccolo Xpress point-of-care chemistry analyzer","volume":"29","author":"Park","year":"2009","journal-title":"Korean J Lab Med"},{"key":"key20200824111041599_ref1-bib66","doi-asserted-by":"publisher","first-page":"1284","DOI":"10.1016\/j.clinbiochem.2008.08.058","article-title":"Evaluation of the Piccolo Xpress chemistry analyzer for point of care testing of plasma liver function markers, electrolytes and metabolites","volume":"41","author":"Schnabl","year":"2008","journal-title":"Clin Biochem"},{"key":"key20200824111041599_ref1-bib67","doi-asserted-by":"publisher","first-page":"1026","DOI":"10.1016\/j.clinbiochem.2010.04.055","article-title":"Evaluation of the analytical performance of the Nova StatSensor creatinine meter and reagent strip technology for whole blood testing","volume":"43","author":"Schnabl","year":"2010","journal-title":"Clin Biochem"},{"key":"key20200824111041599_ref1-bib68","doi-asserted-by":"publisher","first-page":"3","DOI":"10.1515\/CCLM.2008.004","article-title":"New creatinine sensor for point-of-care testing of creatinine meets the National Kidney Disease Education Program guidelines","volume":"46","author":"Skurup","year":"2008","journal-title":"Clin Chem Lab Med"},{"key":"key20200824111041599_ref1-bib69","first-page":"1225","article-title":"Evaluation of the analytical performance of the nova StatSensor creatinine meter for blood testing","volume":"95","author":"Srihong","year":"2012","journal-title":"J Med Assoc Thai"},{"key":"key20200824111041599_ref1-bib70","first-page":"S149","article-title":"Estimated glomerular filtration rate (GFR) using a point of care (POC) measure of creatinine in patients with iohexol determinate GFR","volume":"55","author":"Stojkovic","year":"2017","journal-title":"Clin Chem Lab Med"},{"key":"key20200824111041599_ref1-bib71","first-page":"A102","article-title":"Creatinine levels in patients with renal disease: discordance between POC meter and automated enzymatic methods","volume":"55","author":"Straseski","year":"2009","journal-title":"Clin Chem"},{"key":"key20200824111041599_ref1-bib72","first-page":"507","article-title":"Investigating possible causes of discrepant creatinine results: discordance in patients with renal insufficiency","volume":"134","author":"Straseski","year":"2010","journal-title":"Am J Clin Pathol"},{"key":"key20200824111041599_ref1-bib73","doi-asserted-by":"publisher","first-page":"1566","DOI":"10.1373\/clinchem.2011.165480","article-title":"Investigating interferences of a whole-blood point-of-care creatinine analyzer: comparison to plasma enzymatic and definitive creatinine methods in an acute-care setting","volume":"57","author":"Straseski","year":"2011","journal-title":"Clin Chem"},{"key":"key20200824111041599_ref1-bib74","first-page":"S690","article-title":"Controlled trial between measurement of glomerular filtration rate on venous blood (automated laboratory) and capillary blood (bedside system)","volume":"1","author":"Treves","year":"2011","journal-title":"Clin Chem Lab Med"},{"key":"key20200824111041599_ref1-bib75","doi-asserted-by":"publisher","first-page":"1227","DOI":"10.1016\/j.ejrad.2015.04.001","article-title":"Screening for impaired renal function in outpatients before iodinated contrast injection: comparing the Choyke questionnaire with a rapid point-of-care-test","volume":"84","author":"Too","year":"2015","journal-title":"Eur J Radiol"},{"key":"key20200824111041599_ref1-bib76","doi-asserted-by":"publisher","first-page":"1547","DOI":"10.1515\/cclm-2014-0932","article-title":"Application of a point of care creatinine device for trend monitoring in kidney transplant patients: fit for purpose?","volume":"53","author":"van Lint","year":"2015","journal-title":"Clini Chem Lab Med"},{"key":"key20200824111041599_ref1-bib77","doi-asserted-by":"publisher","first-page":"1926","DOI":"10.1007\/s00330-010-1754-2","article-title":"Screening for renal insufficiency following ESUR (European Society of Urogenital Radiology) guidelines with on-site creatinine measurements in an outpatient setting","volume":"20","author":"Ledermann","year":"2010","journal-title":"Eur Radiol"},{"key":"key20200824111041599_ref1-bib78","doi-asserted-by":"publisher","first-page":"S24","DOI":"10.1016\/j.radi.2016.07.006","article-title":"Screening prior to gadolinium based contrast agent administration: a UK survey of guideline implementation and adherence","volume":"22","author":"Snaith","year":"2016","journal-title":"Radiography"},{"key":"key20200824111041599_ref1-bib79","first-page":"S496","article-title":"The impact of Nova StatSensor creatinine point-of-care monitoring system on the number of i.v. contrast-enhanced CT scanning procedures performed in a clinical PET\/CT unit","volume":"2","author":"Stahr","year":"2010","journal-title":"Eur J Nucl Med Mol Imag"},{"key":"key20200824111041599_ref1-bib80","doi-asserted-by":"publisher","first-page":"1344","DOI":"10.1016\/j.clinbiochem.2015.08.002","article-title":"Analytical performance of the Abaxis Piccolo Xpress\u00ae point of care analyzer in whole blood, serum, and plasma","volume":"48","author":"Murata","year":"2015","journal-title":"Clin Biochem"},{"key":"key20200824111041599_ref1-bib81","doi-asserted-by":"publisher","first-page":"376","DOI":"10.2214\/AJR.07.3280","article-title":"Frequency of serum creatinine changes in the absence of iodinated contrast material: implications for studies of contrast nephrotoxicity","volume":"191","author":"Newhouse","year":"2008","journal-title":"AJR Am J Roentgenol"},{"key":"key20200824111041599_ref1-bib82","doi-asserted-by":"publisher","first-page":"711","DOI":"10.2214\/AJR.08.1413","article-title":"Background fluctuation of kidney function versus contrast-induced nephrotoxicity","volume":"192","author":"Bruce","year":"2009","journal-title":"AJR Am J Roentgenol"},{"key":"key20200824111041599_ref1-bib83","doi-asserted-by":"publisher","first-page":"886","DOI":"10.1016\/j.ejrad.2014.02.014","article-title":"Fluctuations in eGFR in relation to unenhanced and enhanced MRI and CT outpatients","volume":"83","author":"Azzouz","year":"2014","journal-title":"Eur J Radiol"},{"key":"key20200824111041599_ref1-bib84","doi-asserted-by":"publisher","first-page":"81","DOI":"10.5500\/wjt.v7.i1.81","article-title":"Contrast-induced acute kidney injury in kidney transplant recipients: a systematic review and meta-analysis","volume":"7","author":"Cheungpasitporn","year":"2017","journal-title":"World J Transplant"},{"key":"key20200824111041599_ref1-bib85","doi-asserted-by":"publisher","first-page":"785","DOI":"10.1007\/s00134-017-4700-9","article-title":"Contrast-associated acute kidney injury in the critically ill: systematic review and Bayesian meta-analysis","volume":"43","author":"Ehrmann","year":"2017","journal-title":"Intensive Care Med"},{"key":"key20200824111041599_ref1-bib86","doi-asserted-by":"publisher","first-page":"44","DOI":"10.1016\/j.annemergmed.2017.06.041","article-title":"Acute kidney injury after computed tomography: a meta-analysis","volume":"71","author":"Aycock","year":"2018","journal-title":"Ann Emerg Med"},{"key":"key20200824111041599_ref1-bib87","doi-asserted-by":"publisher","first-page":"2554","DOI":"10.1016\/j.ejrad.2011.11.020","article-title":"Meta-analysis: serum creatinine changes following contrast enhanced CT imaging","volume":"81","author":"Kooiman","year":"2012","journal-title":"Eur J Radiol"},{"key":"key20200824111041599_ref1-bib88","doi-asserted-by":"publisher","first-page":"e387","DOI":"10.1016\/j.ejrad.2013.04.029","article-title":"Contrast induced nephropathy in patients undergoing intravenous (IV) contrast enhanced computed tomography (CECT) and the relationship with risk factors: a meta-analysis","volume":"82","author":"Moos","year":"2013","journal-title":"Eur J Radiol"},{"key":"key20200824111041599_ref1-bib89","doi-asserted-by":"publisher","first-page":"714","DOI":"10.1148\/radiol.14132418","article-title":"Intravenous contrast material exposure is not an independent risk factor for dialysis or mortality","volume":"273","author":"McDonald","year":"2014","journal-title":"Radiology"},{"key":"key20200824111041599_ref1-bib90","doi-asserted-by":"publisher","first-page":"94","DOI":"10.1148\/radiol.12121394","article-title":"Contrast material-induced nephrotoxicity and intravenous low-osmolality iodinated contrast material","volume":"267","author":"Davenport","year":"2013","journal-title":"Radiology"},{"key":"key20200824111041599_ref1-bib91","doi-asserted-by":"publisher","first-page":"719","DOI":"10.1148\/radiol.13122276","article-title":"Contrast material-induced nephrotoxicity and intravenous low-osmolality iodinated contrast material: risk stratification by using estimated glomerular filtration rate","volume":"268","author":"Davenport","year":"2013","journal-title":"Radiology"},{"key":"key20200824111041599_ref1-bib92","doi-asserted-by":"publisher","first-page":"65","DOI":"10.1148\/radiol.13130775","article-title":"Risk of intravenous contrast material-mediated acute kidney injury: a propensity score-matched study stratified by baseline-estimated glomerular filtration rate","volume":"271","author":"McDonald","year":"2014","journal-title":"Radiology"},{"key":"key20200824111041599_ref1-bib93","doi-asserted-by":"publisher","first-page":"757","DOI":"10.7326\/0003-4819-127-8_Part_2-199710151-00064","article-title":"Estimating causal effects from large data sets using propensity scores","volume":"127","author":"Rubin","year":"1997","journal-title":"Ann Intern Med"},{"key":"key20200824111041599_ref1-bib94","doi-asserted-by":"publisher","first-page":"33","DOI":"10.1080\/00031305.1985.10479383","article-title":"Constructing a control group using multivariate matched sampling methods that incorporate the propensity score","volume":"39","author":"Rosenbaum","year":"1985","journal-title":"Am Stat"},{"key":"key20200824111041599_ref1-bib95","doi-asserted-by":"publisher","first-page":"622","DOI":"10.1016\/j.jclinepi.2013.10.019","article-title":"The statistical significance of randomized controlled trial results is frequently fragile: a case for a Fragility Index","volume":"67","author":"Walsh","year":"2014","journal-title":"J Clin Epidemiol"},{"key":"key20200824111041599_ref1-bib96","doi-asserted-by":"publisher","first-page":"822","DOI":"10.2214\/AJR.17.19499","article-title":"Propensity score matching as a substitute for randomized controlled trials on acute kidney injury after contrast media administration: a systematic review","volume":"211","author":"Dekkers","year":"2018","journal-title":"AJR Am J Roentgenol"},{"key":"key20200824111041599_ref1-bib97","doi-asserted-by":"publisher","first-page":"577","DOI":"10.1016\/j.annemergmed.2016.11.021","article-title":"Risk of acute kidney injury after intravenous contrast media administration","volume":"69","author":"Hinson","year":"2017","journal-title":"Ann Emerg Med"},{"key":"key20200824111041599_ref1-bib98","doi-asserted-by":"publisher","first-page":"414","DOI":"10.1148\/radiol.2017161573","article-title":"Is intravenous administration of iodixanol associated with increased risk of acute kidney injury, dialysis, or mortality? A propensity score-adjusted study","volume":"285","author":"McDonald","year":"2017","journal-title":"Radiology"},{"key":"key20200824111041599_ref1-bib99","volume-title":"Cochrane Handbook for Systematic Reviews of Interventions Version 5.1.0 [updated March 2011","author":"Higgins","year":"2011"},{"key":"key20200824111041599_ref1-bib100","doi-asserted-by":"publisher","first-page":"e60009","DOI":"10.1371\/journal.pone.0060009","article-title":"Prevention of contrast-induced acute kidney injury: is simple oral hydration similar to intravenous? A systematic review of the evidence","volume":"8","author":"Hiremath","year":"2013","journal-title":"PLOS ONE"},{"key":"key20200824111041599_ref1-bib101","doi-asserted-by":"publisher","first-page":"e000317","DOI":"10.1136\/openhrt-2015-000317","article-title":"Systematic oral hydration with water is similar to parenteral hydration for prevention of contrast-induced nephropathy: an updated meta-analysis of randomised clinical data","volume":"2","author":"Agarwal","year":"2015","journal-title":"Open Heart"},{"key":"key20200824111041599_ref1-bib102","doi-asserted-by":"publisher","first-page":"323","DOI":"10.1186\/s12882-018-1113-0","article-title":"Effectiveness of contrast-associated acute kidney injury prevention methods; a systematic review and network meta-analysis","volume":"19","author":"Ahmed","year":"2018","journal-title":"BMC Nephrol"},{"key":"key20200824111041599_ref1-bib103","doi-asserted-by":"publisher","first-page":"2120","DOI":"10.1093\/ndt\/gfl133","article-title":"A randomized trial of saline hydration to prevent contrast nephropathy in chronic renal failure patients","volume":"21","author":"Dussol","year":"2006","journal-title":"Nephrol Dial Transplant"},{"key":"key20200824111041599_ref1-bib104","doi-asserted-by":"publisher","first-page":"1312","DOI":"10.1016\/S0140-6736(17)30057-0","article-title":"Prophylactic hydration to protect renal function from intravascular iodinated contrast material in patients at high risk of contrast-induced nephropathy (AMACING): a prospective, randomised, phase 3, controlled, open-label, non-inferiority trial","volume":"389","author":"Nijssen","year":"2017","journal-title":"Lancet"},{"key":"key20200824111041599_ref1-bib105","doi-asserted-by":"publisher","first-page":"109","DOI":"10.1016\/j.eclinm.2018.10.007","article-title":"Prophylactic intravenous hydration to protect renal function from intravascular iodinated contrast material (AMACING): long-term results of a prospective, randomised, controlled trial","volume":"4\u20135","author":"Nijssen","year":"2018","journal-title":"EClinicalMedicine"},{"key":"key20200824111041599_ref1-bib106","doi-asserted-by":"publisher","first-page":"616","DOI":"10.1097\/RLI.0000000000000479","article-title":"Evaluation of safety guidelines on the use of iodinated contrast material: conundrum continued","volume":"53","author":"Nijssen","year":"2018","journal-title":"Invest Radiol"},{"key":"key20200824111041599_ref1-bib107","volume-title":"Prevention of Contrast Induced Acute Kidney Injury (CI-AKI) in Adult Patients","author":"The Renal Association, British Cardiovascular Intervention Society and the Royal College of Radiologists","year":"2013"},{"key":"key20200824111041599_ref1-bib108","unstructured":"National Institute for Health and Care Excellence (NICE). Acute Kidney Injury: Prevention, Detection and Management of Acute Kidney Injury up to the Point of Renal Replacement Therapy. Clinical Guidelines, CG169. London: NICE; 2013. URL: https:\/\/guidance.nice.org.uk\/cg169 (accessed 31 January 2019)."},{"key":"key20200824111041599_ref1-bib109","unstructured":"Royal College of Radiologists. Standards for Intravascular Contrast Administration to Adult Patients. 3rd edn. London: Royal College of Radiologists; 2015."},{"key":"key20200824111041599_ref1-bib110","first-page":"8","article-title":"Acute kidney injury: prevention, detection and management up to the point of renal replacement therapy","volume":"8","author":"National Clinical Guideline Centre","year":"2013","journal-title":"Royal Coll Physicians"},{"key":"key20200824111041599_ref1-bib111","unstructured":"Department of Health and Social Care. National Schedule of Reference Costs 2015\u20132016. London: Department of Health and Social Care; 2016. URL: www.gov.uk\/government\/publications\/nhs-reference-costs-2015-to-2016 (accessed 15 April 2019)."},{"key":"key20200824111041599_ref1-bib112","doi-asserted-by":"publisher","first-page":"A044","DOI":"10.1093\/ajcp\/143.suppl1.045","article-title":"Point-of-care creatinine\/estimated glomerular filtration rate testing within the radiology department of an academic medical center improves workflow and reduces costs","volume":"1","author":"Nowacek","year":"2015","journal-title":"Am J Clin Pathol"},{"key":"key20200824111041599_ref1-bib113","volume-title":"RX205 Point-of-care Creatinine Tests","author":"Chalkidou","year":"2019"},{"key":"key20200824111041599_ref1-bib114","doi-asserted-by":"publisher","first-page":"1266","DOI":"10.1007\/s00330-014-3149-2","article-title":"Prediction of presence of kidney disease in a general patient population undergoing intravenous iodinated contrast enhanced computed tomography","volume":"24","author":"Moos","year":"2014","journal-title":"Eur Radiol"},{"key":"key20200824111041599_ref1-bib115","doi-asserted-by":"publisher","first-page":"e3560","DOI":"10.1097\/MD.0000000000003560","article-title":"Contrast-induced nephropathy after computed tomography in stable CKD patients with proper prophylaxis: 8-year experience of outpatient prophylaxis program","volume":"95","author":"Park","year":"2016","journal-title":"Medicine"},{"key":"key20200824111041599_ref1-bib116","doi-asserted-by":"publisher","first-page":"1613","DOI":"10.1007\/s00330-016-4478-0","article-title":"Prediction of presence of kidney disease in patients undergoing intravenous iodinated contrast enhanced computed tomography: a validation study","volume":"27","author":"Schreuder","year":"2017","journal-title":"Eur Radiol"},{"key":"key20200824111041599_ref1-bib117","doi-asserted-by":"publisher","first-page":"1018","DOI":"10.1053\/j.ajkd.2009.10.057","article-title":"Incidence and outcomes of contrast-induced nephropathy after computed tomography in patients with CKD: a quality improvement report","volume":"55","author":"Kim","year":"2010","journal-title":"Am J Kidney Dis"},{"key":"key20200824111041599_ref1-bib118","unstructured":"Office for National Statistics. National Life Tables: England. Newport: Office for National Statistics; 2018. URL: www.ons.gov.uk\/peoplepopulationandcommunity\/birthsdeathsandmarriages\/lifeexpectancies\/datasets\/nationallifetablesenglandreferencetables (accessed 7 February 2020)."},{"key":"key20200824111041599_ref1-bib119","doi-asserted-by":"publisher","first-page":"509","DOI":"10.1111\/j.1524-4733.2010.00700.x","article-title":"Populating an economic model with health state utility values: moving toward better practice","volume":"13","author":"Ara","year":"2010","journal-title":"Value Health"},{"key":"key20200824111041599_ref1-bib120","doi-asserted-by":"publisher","first-page":"e1001307","DOI":"10.1371\/journal.pmed.1001307","article-title":"A systematic review and meta-analysis of utility-based quality of life in chronic kidney disease treatments","volume":"9","author":"Wyld","year":"2012","journal-title":"PLOS Med"},{"issue":"32","key":"key20200824111041599_ref1-bib121","doi-asserted-by":"publisher","DOI":"10.3310\/hta22320","article-title":"The future for diagnostic tests of acute kidney injury in critical care: evidence synthesis, care pathway analysis and research prioritisation","volume":"22","author":"Hall","year":"2018","journal-title":"Health Technol Assess"},{"key":"key20200824111041599_ref1-bib122","doi-asserted-by":"publisher","first-page":"1095","DOI":"10.1097\/00005650-199711000-00002","article-title":"Modeling valuations for EuroQol health states","volume":"35","author":"Dolan","year":"1997","journal-title":"Med Care"},{"key":"key20200824111041599_ref1-bib123","volume-title":"Unit Costs of Health and Social Care 2017","author":"Curtis","year":"2017"},{"key":"key20200824111041599_ref1-bib124","unstructured":"Department of Health and Social Care. National Schedule of Reference Costs \u2013 Year 2017\u201318 \u2013 NHS Trust and NHS Foundation Trusts. London: Department of Health and Social Care; 2018. URL: https:\/\/improvement.nhs.uk\/resources\/reference-costs\/ (accessed 15 April 2019)."},{"key":"key20200824111041599_ref1-bib125","doi-asserted-by":"publisher","first-page":"309","DOI":"10.3163\/1536-5050.104.4.011","article-title":"Supplementary searches of PubMed to improve currency of MEDLINE and MEDLINE In-Process searches via Ovid","volume":"104","author":"Duffy","year":"2016","journal-title":"J Med Libr Assoc"},{"key":"key20200824111041599_ref1-bib126","doi-asserted-by":"publisher","first-page":"194","DOI":"10.1016\/S0882-5963(05)80084-3","article-title":"Point-of-care technology: the i-STAT system for bedside blood analysis","volume":"10","author":"Adams","year":"1995","journal-title":"J Pediatr Nurs"},{"key":"key20200824111041599_ref1-bib127","unstructured":"Canadian Agency for Drugs and Technologies in Health. Point of Care Testing for Human Chorionic Gonadotropin, Creatinine, and Blood Urea Nitrogen: Cost-effectiveness. Ottawa, ON: Canadian Agency for Drugs and Technologies in Health; 2013. URL: https:\/\/www.crd.york.ac.uk\/CRDWeb\/ShowRecord.asp?ID=32014000136 (accessed 21 May 2019)."},{"key":"key20200824111041599_ref1-bib128","unstructured":"Canadian Agency for Drugs and Technologies in Health (CADTH). CADTH Database Search Filters. Ottawa, ON: Canadian Agency for Drugs and Technologies in Health; 2016. URL: www.cadth.ca\/resources\/finding-evidence\/strings-attached-cadths-database-search-filters (accessed 13 January 2019)."},{"key":"key20200824111041599_ref1-bib129","doi-asserted-by":"publisher","first-page":"182","DOI":"10.1590\/S0120-41572012000300005","article-title":"Cost-effectiveness of iso- versus low-osmolality contrast media in outpatients with high risk of contrast medium-induced nephropathy","volume":"32","author":"Chica\u00edza-Becerra","year":"2012","journal-title":"Biomedica"},{"key":"key20200824111041599_ref1-bib130","doi-asserted-by":"publisher","first-page":"69","DOI":"10.1017\/S0266462313000706","article-title":"Economic evaluation of intravenous iodinated contrast media in Italy","volume":"30","author":"Iannazzo","year":"2014","journal-title":"Int J Technol Assess Health Care"},{"key":"key20200824111041599_ref1-bib131","doi-asserted-by":"publisher","first-page":"4095","DOI":"10.1093\/ndt\/gfs410","article-title":"Economic evaluation of different treatment modalities in acute kidney injury","volume":"27","author":"De Smedt","year":"2012","journal-title":"Nephrol Dial Transplant"},{"key":"key20200824111041599_ref1-bib132","doi-asserted-by":"publisher","first-page":"54","DOI":"10.1093\/ndt\/gfu314","article-title":"Economics of dialysis dependence following renal replacement therapy for critically ill acute kidney injury patients","volume":"30","author":"Ethgen","year":"2015","journal-title":"Nephrol Dial Transplant"},{"key":"key20200824111041599_ref1-bib133","doi-asserted-by":"publisher","first-page":"1362","DOI":"10.1093\/ndt\/gfu016","article-title":"The economic impact of acute kidney injury in England","volume":"29","author":"Kerr","year":"2014","journal-title":"Nephrol Dial Transplant"},{"key":"key20200824111041599_ref1-bib134","doi-asserted-by":"publisher","first-page":"262","DOI":"10.11613\/BM.2015.027","article-title":"Cost-effectiveness analysis of acute kidney injury biomarkers in pediatric cardiac surgery","volume":"25","author":"Petrovic","year":"2015","journal-title":"Biochemia Medica"},{"key":"key20200824111041599_ref1-bib135","doi-asserted-by":"publisher","first-page":"409","DOI":"10.1161\/CIRCULATIONAHA.110.970160","article-title":"Associations between acute kidney injury and cardiovascular and renal outcomes after coronary angiography","volume":"123","author":"James","year":"2011","journal-title":"Circulation"},{"key":"key20200824111041599_ref1-bib136","doi-asserted-by":"publisher","first-page":"329","DOI":"10.1001\/archinte.162.3.329","article-title":"Prevention of contrast media-associated nephropathy: randomized comparison of 2 hydration regimens in 1620 patients undergoing coronary angioplasty","volume":"162","author":"Mueller","year":"2002","journal-title":"Arch Intern Med"},{"key":"key20200824111041599_ref1-bib137","doi-asserted-by":"publisher","first-page":"961","DOI":"10.1056\/NEJMoa0804626","article-title":"Percutaneous coronary intervention versus coronary-artery bypass grafting for severe coronary artery disease","volume":"360","author":"Serruys","year":"2009","journal-title":"N Engl J Med"},{"key":"key20200824111041599_ref1-bib138","doi-asserted-by":"publisher","first-page":"375","DOI":"10.1038\/sj.ki.5000058","article-title":"The progression of chronic kidney disease: a 10-year population-based study of the effects of gender and age","volume":"69","author":"Eriksen","year":"2006","journal-title":"Kidney Int"},{"key":"key20200824111041599_ref1-bib139","doi-asserted-by":"publisher","first-page":"340","DOI":"10.1007\/s10157-010-0304-1","article-title":"Measurement of health-related quality of life in patients with chronic kidney disease in Japan with EuroQol (EQ-5D)","volume":"14","author":"Tajima","year":"2010","journal-title":"Clin Exp Nephrol"},{"key":"key20200824111041599_ref1-bib140","doi-asserted-by":"publisher","first-page":"736","DOI":"10.1136\/bmj.316.7133.736","article-title":"Variations in population health status: results from a United Kingdom national questionnaire survey","volume":"316","author":"Kind","year":"1998","journal-title":"BMJ"},{"key":"key20200824111041599_ref1-bib141","doi-asserted-by":"publisher","first-page":"800","DOI":"10.1177\/0272989X11401031","article-title":"Catalogue of EQ-5D scores for the United Kingdom","volume":"31","author":"Sullivan","year":"2011","journal-title":"Med Decis Making"},{"key":"key20200824111041599_ref1-bib142","unstructured":"Department of Health and Social Care. National Schedule of Reference Costs 2011\u20132012. London: Department of Health and Social Care; 2012. URL: www.gov.uk\/government\/publications\/nhs-reference-costs-financial-year-2011-to-2012 (accessed 15 April 2019)."},{"key":"key20200824111041599_ref1-bib143","volume-title":"Unit Costs of Health and Social Care 2012","author":"Curtis","year":"2012"},{"key":"key20200824111041599_ref1-bib144","unstructured":"Joint Formulary Committee. British National Formulary (BNF). 62nd edition. London: British Medical Association and The Royal Pharmaceutical Society of Great Britain; 2013."},{"key":"key20200824111041599_ref1-bib145","unstructured":"National Institute for Health and Care Excellence (NICE). Anaemia Management in People with Chronic Kidney Disease Clinical Guidelines, CG114. London: NICE; 2011. URL: www.nice.org.uk\/guidance\/cg114 (accessed 21 April 2020)."},{"key":"key20200824111041599_ref1-bib146","doi-asserted-by":"publisher","first-page":"2256","DOI":"10.1111\/j.1523-1755.2005.00684.x","article-title":"The role of osmolality in the incidence of contrast-induced nephropathy: a systematic review of angiographic contrast media in high risk patients","volume":"68","author":"Solomon","year":"2005","journal-title":"Kidney Int"},{"key":"key20200824111041599_ref1-bib147","doi-asserted-by":"publisher","first-page":"97","DOI":"10.1148\/radiol.2481071484","article-title":"Iso-osmolality versus low-osmolality iodinated contrast medium at intravenous contrast-enhanced CT: effect on kidney function","volume":"248.1","author":"Nguyen","year":"2008","journal-title":"Radiology"},{"key":"key20200824111041599_ref1-bib148","doi-asserted-by":"publisher","first-page":"651","DOI":"10.1097\/01.rli.0000229742.54589.7b","article-title":"Contrast media and nephropathy: findings from systematic analysis and Food and Drug Administration reports of adverse effects","volume":"41.8","author":"Solomon","year":"2006","journal-title":"Invest Radiol"},{"key":"key20200824111041599_ref1-bib149","doi-asserted-by":"publisher","first-page":"1095","DOI":"10.4065\/83.10.1095","article-title":"Mortality associated with nephropathy after radiographic contrast exposure","volume":"83","author":"From","year":"2008","journal-title":"Mayo Clin Proc"},{"key":"key20200824111041599_ref1-bib150","doi-asserted-by":"publisher","first-page":"1044","DOI":"10.1097\/01.CCM.0000206287.22318.C3","article-title":"Cost-effectiveness of hemofiltration to prevent contrast nephropathy in patients with chronic kidney disease","volume":"34","author":"Klarenbach","year":"2006","journal-title":"Crit Care Med"},{"key":"key20200824111041599_ref1-bib151","first-page":"68","article-title":"Nefropat\u00eda por medios de contraste","volume":"32","author":"Aguirre Caicedo","year":"2007","journal-title":"Acta Med Colomb"}],"container-title":["Health Technology Assessment"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/njl-admin.nihr.ac.uk\/document\/download\/2033621","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/www.journalslibrary.nihr.ac.uk\/publications\/hta24390\/hta24390.xml","content-type":"text\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/njl-admin.nihr.ac.uk\/document\/download\/2033621","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,8,15]],"date-time":"2023-08-15T15:57:14Z","timestamp":1692115034000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.journalslibrary.nihr.ac.uk\/hta\/hta24390"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2020,8]]},"references-count":151,"journal-issue":{"issue":"39","published-online":{"date-parts":[[2020,8]]}},"alternative-id":["10.3310\/hta24390"],"URL":"https:\/\/doi.org\/10.3310\/hta24390","relation":{},"ISSN":["1366-5278","2046-4924"],"issn-type":[{"value":"1366-5278","type":"print"},{"value":"2046-4924","type":"electronic"}],"subject":[],"published":{"date-parts":[[2020,8]]},"assertion":[{"value":"This content has been made freely available to all.","name":"free","label":"Free to read"},{"value":"11-2018","name":"contractual_start_date","label":"Contractual start date","group":{"name":"article_history","label":"Article History"}},{"value":"5-2019","name":"editorial_review_begun","label":"Editorial review begun","group":{"name":"article_history","label":"Article History"}},{"value":"11-2019","name":"accepted_for_publication","label":"Accepted for publication","group":{"name":"article_history","label":"Article History"}}]}}