{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,14]],"date-time":"2026-10-14T01:44:51Z","timestamp":1791942291355,"version":"4.3.4"},"reference-count":14,"publisher":"Korean Ophthalmological Society","issue":"5","license":[{"start":{"date-parts":[[2026,3,17]],"date-time":"2026-03-17T00:00:00Z","timestamp":1773705600000},"content-version":"tdm","delay-in-days":0,"URL":"http:\/\/creativecommons.org\/licenses\/by-nc\/4.0\/"}],"content-domain":{"domain":["ekjo.org"],"crossmark-restriction":true},"short-container-title":["Korean J Ophthalmol"],"published-print":{"date-parts":[[2026,10,5]]},"abstract":"<jats:p>Purpose: To describe a haptic bending adjustment technique for correcting persistent posterior intraocular lens (IOL) tilt after flanged intrascleral fixation and to evaluate its anatomical and optical outcomes.Methods: This retrospective case series included four eyes with symptomatic postoperative IOL tilt following flanged intrascleral fixation. The haptics were first shortened and re-flanged, and an additional bend was created approximately 1 mm proximal to the haptic tip on the side corresponding to the posterior tilt. IOL tilt was quantified using Scheimpflug imaging, and refractive outcomes were analyzed using power-vector analysis of manifest refraction.Results: Patient age ranged from 32 to 63 years, with a mean operative time of 25.5 \u00b1 8.23 minutes. IOL tilt decreased from 6\u00b0\u20138\u00b0 to 2\u00b0\u20134\u00b0 and remained stable during follow-up. All eyes showed improved visual acuity and reduced refractive astigmatism without change in corneal astigmatism. No intraoperative complications, recurrent tilt, or reoperations occurred.Conclusions: Haptic bending combined with haptic shortening may provide a feasible option for correcting posterior IOL tilt after flanged intrascleral fixation without creating new scleral tunnels or exchanging the IOL.<\/jats:p>","DOI":"10.3341\/kjo.2025.0151","type":"journal-article","created":{"date-parts":[[2026,3,17]],"date-time":"2026-03-17T14:01:48Z","timestamp":1773756108000},"page":"459-467","update-policy":"https:\/\/doi.org\/10.3341\/crossmark_policy","source":"Crossref","is-referenced-by-count":0,"title":["A Novel Haptic Bending Technique to Correct Tilt after Flanged Intrascleral Intraocular Lens Fixation"],"prefix":"10.3341","volume":"40","author":[{"given":"Young Hyun","family":"Jeon","sequence":"first","affiliation":[{"name":"Department of Ophthalmology, Dong-A University College of Medicine, Busan, Korea"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Nam Yeong","family":"Kim","sequence":"additional","affiliation":[{"name":"Department of Ophthalmology, Dong-A University College of Medicine, Busan, Korea"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Yoon Hyung","family":"Kwon","sequence":"additional","affiliation":[{"name":"Department of Ophthalmology, Dong-A University College of Medicine, Busan, Korea"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"1893","reference":[{"key":"ref1","doi-asserted-by":"publisher","DOI":"10.1016\/j.jcrs.2007.07.013"},{"key":"ref2","doi-asserted-by":"publisher","DOI":"10.1016\/j.jcrs.2008.04.040"},{"key":"ref3","doi-asserted-by":"publisher","DOI":"10.1016\/j.ophtha.2013.08.043"},{"key":"ref4","doi-asserted-by":"publisher","DOI":"10.1016\/j.ophtha.2017.03.036"},{"key":"ref5","doi-asserted-by":"publisher","DOI":"10.1097\/iae.0000000000002455"},{"key":"ref6","doi-asserted-by":"publisher","DOI":"10.1097\/iae.0000000000004618"},{"key":"ref7","doi-asserted-by":"publisher","DOI":"10.1016\/s0886-3350(99)80019-4"},{"key":"ref8","doi-asserted-by":"publisher","DOI":"10.3928\/1081-597x-20021101-04"},{"key":"ref9","doi-asserted-by":"publisher","DOI":"10.1016\/j.ajo.2018.01.007"},{"key":"ref10","doi-asserted-by":"publisher","DOI":"10.1016\/s0886-3350(00)00797-5"},{"key":"ref11","doi-asserted-by":"publisher","DOI":"10.1007\/s10792-020-01312-9"},{"key":"ref12","doi-asserted-by":"publisher","DOI":"10.1016\/j.ajoc.2018.02.025"},{"key":"ref13","doi-asserted-by":"publisher","DOI":"10.1016\/j.ajoc.2023.101845"},{"key":"ref14","doi-asserted-by":"publisher","DOI":"10.1016\/s0886-3350(13)80440-3"}],"container-title":["Korean Journal of Ophthalmology"],"original-title":[],"language":"en","link":[{"URL":"http:\/\/www.ekjo.org\/upload\/pdf\/kjo-2025-0151.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/www.ekjo.org\/journal\/view.php?doi=10.3341\/kjo.2025.0151","content-type":"unspecified","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/www.ekjo.org\/upload\/pdf\/kjo-2025-0151.pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,10,14]],"date-time":"2026-10-14T00:51:47Z","timestamp":1791939107000},"score":1,"resource":{"primary":{"URL":"http:\/\/www.ekjo.org\/journal\/view.php?doi=10.3341\/kjo.2025.0151"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,10,5]]},"references-count":14,"journal-issue":{"issue":"5","published-print":{"date-parts":[[2026,10]]}},"URL":"https:\/\/doi.org\/10.3341\/kjo.2025.0151","relation":{},"ISSN":["1011-8942","2092-9382"],"issn-type":[{"value":"1011-8942","type":"print"},{"value":"2092-9382","type":"electronic"}],"subject":[],"published":{"date-parts":[[2026,10,5]]},"assertion":[{"value":"2025-10-19","order":0,"name":"received","label":"Received","group":{"name":"publication_history","label":"Publication History"}},{"value":"2026-03-11","order":1,"name":"accepted","label":"Accepted","group":{"name":"publication_history","label":"Publication History"}},{"value":"2026-03-17","order":2,"name":"published","label":"Published online","group":{"name":"publication_history","label":"Publication History"}},{"value":"2026-10-05","order":3,"name":"published","label":"Print publication","group":{"name":"publication_history","label":"Publication History"}}]}}