{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,14]],"date-time":"2026-10-14T01:44:38Z","timestamp":1791942278957,"version":"4.3.4"},"reference-count":11,"publisher":"Korean Ophthalmological Society","issue":"5","license":[{"start":{"date-parts":[[2026,5,7]],"date-time":"2026-05-07T00:00:00Z","timestamp":1778112000000},"content-version":"tdm","delay-in-days":0,"URL":"http:\/\/creativecommons.org\/licenses\/by-nc\/4.0\/"}],"content-domain":{"domain":["ekjo.org"],"crossmark-restriction":true},"short-container-title":["Korean J Ophthalmol"],"published-print":{"date-parts":[[2026,10,5]]},"abstract":"<jats:p>Purpose: To compare the effective phacoemulsification time (EPT) used in cataract surgery and postoperative outcomes between the Veritas Vision System and the Centurion Vision System.Methods: A retrospective analysis was conducted on 90 eyes from 82 patients with senile cataracts who underwent cataract extraction by phacoemulsification at Samsung Medical Center from December 2022 to May 2023. According to the Lens Opacities Classification System III grading of nucleus opalescence (NO), eyes with grades 3 to 5 were included, subdivided into moderate (\u2265NO3, &lt;NO4) and hard (\u2265NO4, \u2264NO5) cataracts. The Veritas Vision System was utilized for 43 eyes, comprising 26 moderate and 17 hard cataracts, while the Centurion Vision System was utilized for 47 eyes, including 26 moderate and 21 hard cataracts. Intraoperative parameters were ultrasound time (sec), average phacoemulsification power (%), and EPT (%\u00b7s) for the Veritas group; and cumulative dissipated energy (CDE, %\u00b7s) for the Centurion group. Best-corrected visual acuity (BCVA) and endothelial cell counts (ECC) were measured one month postoperatively. All parameters were compared between the subgroups.Results: In both the moderate and hard cataract groups, the EPT in the Veritas group was lower than the CDE in the Centurion group (&lt;i&gt;p&lt;\/i&gt; = 0.035 and &lt;i&gt;p&lt;\/i&gt; = 0.009, respectively). However, no significant differences in postoperative BCVA or ECC changes were observed.Conclusions: The Veritas Vision System demonstrated lower EPTs in the moderate and hard cataract groups. Both systems showed effective and safe surgical outcomes.<\/jats:p>","DOI":"10.3341\/kjo.2025.0196","type":"journal-article","created":{"date-parts":[[2026,5,7]],"date-time":"2026-05-07T07:47:06Z","timestamp":1778140026000},"page":"505-512","update-policy":"https:\/\/doi.org\/10.3341\/crossmark_policy","source":"Crossref","is-referenced-by-count":0,"title":["Comparison of Effective Phacoemulsification Times Used in Cataract Surgery between the Veritas Vision System and the Centurion Vision System"],"prefix":"10.3341","volume":"40","author":[{"given":"Ji Youn","family":"Choi","sequence":"first","affiliation":[{"name":"Department of Ophthalmology, Samsung Medical Center, Sungkyunkwan University School of Medicine, Seoul, Korea"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Won Seok","family":"Song","sequence":"additional","affiliation":[{"name":"Noone Eye Hospital, Seoul, Korea"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Yeo Kyoung","family":"Won","sequence":"additional","affiliation":[{"name":"SNU Eye Clinic, Seoul, Korea"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Dong Hui","family":"Lim","sequence":"additional","affiliation":[{"name":"Department of Ophthalmology, Samsung Medical Center, Sungkyunkwan University School of Medicine, Seoul, Korea"},{"name":"Samsung Advanced Institute for Health Sciences and Technology, Sungkyunkwan University, Seoul, Korea"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"1893","reference":[{"key":"ref1","first-page":"100147","volume-title":"Deep learning-based cataract detection and grading from slit-lamp and retro-illumination photographs: model development and validation study","author":"Son","year":"2022"},{"key":"ref2","first-page":"1698","volume-title":"Prospective study of Centurion<sup>\u00ae<\/sup> versus Infiniti<sup>\u00ae<\/sup> phacoemulsification systems: surgical and visual outcomes","author":"Oh","year":"2017"},{"key":"ref3","doi-asserted-by":"publisher","DOI":"10.1002\/14651858.cd001323.pub2"},{"key":"ref4","doi-asserted-by":"publisher","DOI":"10.3341\/jkos.2018.59.11.1017"},{"key":"ref5","doi-asserted-by":"publisher","DOI":"10.2147\/opth.s363061"},{"key":"ref6","first-page":"822","volume-title":"Comparison of corneal endothelial changes following phacoemulsification with transversal and torsional phacoemulsification machines","author":"Atas","year":"2014"},{"key":"ref7","doi-asserted-by":"publisher","DOI":"10.1016\/j.jcrs.2016.11.034"},{"key":"ref8","first-page":"55","volume-title":"Comparative analysis of corneal morphological changes after transversal and torsional phacoemulsification through 2.2 mm corneal incision","author":"Assaf","year":"2013"},{"key":"ref9","doi-asserted-by":"publisher","DOI":"10.3341\/jkos.2015.56.7.1028"},{"key":"ref10","doi-asserted-by":"publisher","DOI":"10.1097\/00055735-200302000-00003"},{"key":"ref11","doi-asserted-by":"publisher","DOI":"10.2147\/opth.s29865"}],"container-title":["Korean Journal of Ophthalmology"],"original-title":[],"language":"en","link":[{"URL":"http:\/\/www.ekjo.org\/upload\/pdf\/kjo-2025-0196.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/www.ekjo.org\/journal\/view.php?doi=10.3341\/kjo.2025.0196","content-type":"unspecified","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/www.ekjo.org\/upload\/pdf\/kjo-2025-0196.pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,10,14]],"date-time":"2026-10-14T00:51:54Z","timestamp":1791939114000},"score":1,"resource":{"primary":{"URL":"http:\/\/www.ekjo.org\/journal\/view.php?doi=10.3341\/kjo.2025.0196"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,10,5]]},"references-count":11,"journal-issue":{"issue":"5","published-print":{"date-parts":[[2026,10]]}},"URL":"https:\/\/doi.org\/10.3341\/kjo.2025.0196","relation":{},"ISSN":["1011-8942","2092-9382"],"issn-type":[{"value":"1011-8942","type":"print"},{"value":"2092-9382","type":"electronic"}],"subject":[],"published":{"date-parts":[[2026,10,5]]},"assertion":[{"value":"2025-12-15","order":0,"name":"received","label":"Received","group":{"name":"publication_history","label":"Publication History"}},{"value":"2026-05-06","order":1,"name":"accepted","label":"Accepted","group":{"name":"publication_history","label":"Publication History"}},{"value":"2026-05-07","order":2,"name":"published","label":"Published online","group":{"name":"publication_history","label":"Publication History"}},{"value":"2026-10-05","order":3,"name":"published","label":"Print publication","group":{"name":"publication_history","label":"Publication History"}}]}}