{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,12]],"date-time":"2026-10-12T13:17:48Z","timestamp":1791811068915,"version":"4.3.4"},"reference-count":23,"publisher":"Frontiers Media SA","license":[{"start":{"date-parts":[[2021,11,25]],"date-time":"2021-11-25T00:00:00Z","timestamp":1637798400000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"funder":[{"DOI":"10.13039\/501100007601","name":"Horizon 2020","doi-asserted-by":"publisher","award":["Agreement 732515"],"award-info":[{"award-number":["Agreement 732515"]}],"id":[{"id":"10.13039\/501100007601","id-type":"DOI","asserted-by":"publisher"}]}],"content-domain":{"domain":["frontiersin.org"],"crossmark-restriction":true},"short-container-title":["Front. Robot. AI"],"abstract":"<jats:p>Robots for minimally invasive surgery introduce many advantages, but still require the surgeon to alternatively control the surgical instruments and the endoscope. This work aims at providing autonomous navigation of the endoscope during a surgical procedure. The autonomous endoscope motion was based on kinematic tracking of the surgical instruments and integrated with the da Vinci Research Kit. A preclinical usability study was conducted by 10 urologists. They carried out an <jats:italic>ex vivo<\/jats:italic> orthotopic neobladder reconstruction twice, using both traditional and autonomous endoscope control. The usability of the system was tested by asking participants to fill standard system usability scales. Moreover, the effectiveness of the method was assessed by analyzing the total procedure time and the time spent with the instruments out of the field of view. The average system usability score overcame the threshold usually identified as the limit to assess good usability (average score\u00a0=\u00a073.25\u00a0&amp;gt;\u00a068). The average total procedure time with the autonomous endoscope navigation was comparable with the classic control (<jats:italic>p<\/jats:italic>\u00a0=\u00a00.85\u00a0&amp;gt;\u00a00.05), yet it significantly reduced the time out of the field of view (<jats:italic>p<\/jats:italic>\u00a0=\u00a00.022\u00a0&amp;lt;\u00a00.05). Based on our findings, the autonomous endoscope improves the usability of the surgical system, and it has the potential to be an additional and customizable tool for the surgeon that can always take control of the endoscope or leave it to move autonomously.<\/jats:p>","DOI":"10.3389\/frobt.2021.707704","type":"journal-article","created":{"date-parts":[[2021,12,1]],"date-time":"2021-12-01T02:19:24Z","timestamp":1638325164000},"update-policy":"https:\/\/doi.org\/10.3389\/crossmark-policy","source":"Crossref","is-referenced-by-count":20,"title":["Automating Endoscope Motion in Robotic Surgery: A Usability Study on da Vinci-Assisted Ex Vivo Neobladder Reconstruction"],"prefix":"10.3389","volume":"8","author":[{"given":"Tommaso","family":"Da Col","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Guido","family":"Caccianiga","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Michele","family":"Catellani","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Andrea","family":"Mariani","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Matteo","family":"Ferro","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Giovanni","family":"Cordima","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Elena","family":"De Momi","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Giancarlo","family":"Ferrigno","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Ottavio","family":"de Cobelli","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"1965","published-online":{"date-parts":[[2021,11,25]]},"reference":[{"key":"B1","doi-asserted-by":"publisher","first-page":"E594","DOI":"10.5489\/cuaj.6520","article-title":"Current Status of Wet Lab and Cadaveric Simulation in Urological Training: A Systematic Review","volume":"14","author":"Al-Jabir","year":"2020","journal-title":"Can. Urol. Assoc. J."},{"key":"B2","first-page":"4","article-title":"Eye Gaze Tracking for Endoscopic Camera Positioning: an Application of a Hardware\/software Interface Developed to Automate Aesop","volume":"132","author":"Ali","year":"2008","journal-title":"Stud. Health Technol. Inform."},{"key":"B3","doi-asserted-by":"publisher","first-page":"415","DOI":"10.1097\/mou.0000000000000738","article-title":"Ileal Conduit or Orthotopic Neobladder","volume":"30","author":"Almassi","year":"2020","journal-title":"Curr. Opin. Urol."},{"key":"B4","doi-asserted-by":"publisher","first-page":"651","DOI":"10.1146\/annurev-control-062420-090543","article-title":"\u201cAutonomy in Surgical Robotics,\u201d Annual Review of Control","volume":"4","author":"Attanasio","year":"2021","journal-title":"Robotics, Autonomous Syst."},{"key":"B5","doi-asserted-by":"publisher","first-page":"e2351","DOI":"10.1016\/s2666-1683(20)34208-7","article-title":"Robot-assisted Intracorporeal Orthotopic Ileal Neobladder: Description of the \"Shell\" Technique","volume":"19","author":"Bianchi","year":"2020","journal-title":"Eur. Urol. Open Sci."},{"key":"B6","first-page":"189","article-title":"A Quick and Dirty Usability Scale","volume-title":"Usability evaluation in industry","author":"Brooke","year":"1996"},{"key":"B7","first-page":"221","article-title":"Technique of Extracorporeal Urinary Diversion","volume-title":"Robotic Urology","author":"Chennamsetty","year":"2018"},{"key":"B8","doi-asserted-by":"publisher","first-page":"643","DOI":"10.1038\/s41585-020-0375-z","article-title":"Autonomous Surgery in the Era of Robotic Urology: Friend or Foe of the Future Surgeon?","volume":"17","author":"Connor","year":"2020","journal-title":"Nat. Rev. Urol."},{"key":"B9","first-page":"2996","article-title":"SCAN: System for Camera Autonomous Navigation in Robotic-Assisted Surgery","author":"Da Col","year":"2020"},{"key":"B10","doi-asserted-by":"publisher","first-page":"e2036","DOI":"10.1002\/rcs.2036","article-title":"Development and evaluation of an autonomous camera control algorithm on the da Vinci Surgical System","volume":"16","author":"Eslamian","year":"2020","journal-title":"Int. J. Med. Robot"},{"key":"B11","doi-asserted-by":"publisher","first-page":"54","DOI":"10.1007\/s004649900294","article-title":"Determination of the Learning Curve of the AESOP Robot","volume":"11","author":"Jacobs","year":"1997","journal-title":"Surg. Endosc."},{"key":"B12","doi-asserted-by":"publisher","first-page":"1192","DOI":"10.1007\/s00464-016-5090-8","article-title":"Viewpoint Matters: Objective Performance Metrics for Surgeon Endoscope Control during Robot-Assisted Surgery","volume":"31","author":"Jarc","year":"2017","journal-title":"Surg. Endosc."},{"key":"B13","first-page":"6434","article-title":"An open-source research kit for the da Vin-ci\u00ae Surgical System","author":"Kazanzides","year":"2014"},{"key":"B14","doi-asserted-by":"publisher","first-page":"1681","DOI":"10.1007\/s00464-012-2656-y","article-title":"Toward Increased Autonomy in the Surgical OR: Needs, Requests, and Expectations","volume":"27","author":"Kranzfelder","year":"2013","journal-title":"Surg. Endosc."},{"key":"B15","doi-asserted-by":"publisher","first-page":"69","DOI":"10.1089\/end.2006.20.69","article-title":"Construct Validity of the Chicken Model in the Simulation of Laparoscopic Radical Prostatectomy Suture","volume":"20","author":"Laguna","year":"2006","journal-title":"J. D. L. Rosettejournal Endourology"},{"key":"B16","doi-asserted-by":"publisher","first-page":"1461","DOI":"10.1109\/lra.2020.2965067","article-title":"An Experimental Comparison towards Autonomous Camera Navigation to Optimize Training in Robot Assisted Surgery","volume":"5","author":"Mariani","year":"2020","journal-title":"IEEE Robot. Autom. Lett."},{"key":"B17","volume-title":"Outcome Comparison between Ileal Conduit and Orthotopic Neobladder: An Extended Literature Review","author":"Mizzi","year":"2020"},{"key":"B18","doi-asserted-by":"publisher","first-page":"310","DOI":"10.3390\/robotics3030310","article-title":"A Review of Camera Viewpoint Automation in Robotic and Laparoscopic Surgery","volume":"3","author":"Pandya","year":"2014","journal-title":"Robotics"},{"key":"B19","doi-asserted-by":"publisher","first-page":"109","DOI":"10.1089\/end.2020.0313","article-title":"Validity of a Novel Chicken and Porcine Model for Laparoscopic Neobladder Reconstruction","volume":"35","author":"Singh","year":"2021","journal-title":"J. Endourology"},{"key":"B20","doi-asserted-by":"publisher","first-page":"1083","DOI":"10.1016\/s0210-4806(09)73185-7","article-title":"Molleja de pollo: un nuevo modelo para entrenamiento laparosc\u00f3pico de la anastomosis uretrovesical","volume":"33","author":"Sotelo","year":"2009","journal-title":"Actas Urol\u00f3gicas Espa\u00f1olas"},{"key":"B21","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1016\/j.ucl.2017.09.001","article-title":"Patient Selection and Counseling for Urinary Diversion","volume":"45","author":"Spencer","year":"2018","journal-title":"Urol. Clin. North America"},{"key":"B22","doi-asserted-by":"publisher","first-page":"2560","DOI":"10.1007\/s00464-017-5957-3","article-title":"First Experience with the AUTOLAP SYSTEM: an Image-Based Robotic Camera Steering Device","volume":"32","author":"Wijsman","year":"2018","journal-title":"Surg. Endosc."},{"key":"B23","doi-asserted-by":"publisher","first-page":"45","DOI":"10.1007\/s00464-009-0522-3","article-title":"Measuring Mental Workload during the Performance of Advanced Laparoscopic Tasks","volume":"24","author":"Zheng","year":"2010","journal-title":"Surg. Endosc."}],"container-title":["Frontiers in Robotics and AI"],"original-title":[],"link":[{"URL":"https:\/\/www.frontiersin.org\/articles\/10.3389\/frobt.2021.707704\/full","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2021,12,1]],"date-time":"2021-12-01T02:19:31Z","timestamp":1638325171000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.frontiersin.org\/articles\/10.3389\/frobt.2021.707704\/full"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2021,11,25]]},"references-count":23,"alternative-id":["10.3389\/frobt.2021.707704"],"URL":"https:\/\/doi.org\/10.3389\/frobt.2021.707704","relation":{},"ISSN":["2296-9144"],"issn-type":[{"value":"2296-9144","type":"electronic"}],"subject":[],"published":{"date-parts":[[2021,11,25]]},"article-number":"707704"}}