{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,3,19]],"date-time":"2026-03-19T15:44:40Z","timestamp":1773935080882,"version":"3.50.1"},"reference-count":28,"publisher":"Frontiers Media SA","license":[{"start":{"date-parts":[[2026,3,19]],"date-time":"2026-03-19T00:00:00Z","timestamp":1773878400000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"content-domain":{"domain":["frontiersin.org"],"crossmark-restriction":true},"short-container-title":["Front. Robot. AI"],"abstract":"<jats:p>Typical microprocessor-controlled knee prostheses (MPKs) are energetically passive devices. Like MPKs, the biological knee joint is also largely passive during the swing phase of walking. However, unlike users of MPKs, at fast walking speeds otherwise healthy individuals without amputation supplement knee extension during swing phase with power at the knee joint, presumably to increase the speed of knee extension. This paper examines the effect of employing powered swing extension assistance in an otherwise passive MPK at fast walking speeds. Three participants with transfemoral amputation were recruited to walk at speeds ranging from their self-selected walking speed to their maximum safe walking speed with and without powered swing extension assistance on a treadmill. Swing extension assistance was shown to result in a notable increase in the knee angular velocity during swing extension. Rather than translating to a reduction in swing extension time during overground walking, the additional time afforded by faster swing extension resulted in an increase in the time between full knee extension and the onset of loading, named the latency period, indicating users appear to prefer more assurance that their knee has reached full extension prior to heel strike while walking at their maximum safe walking speed. All three participants commented positively about the extension assistance during certain walking trials, but all three also found the elevated terminal impact during the end of swing bad, particularly below their maximum safe walking speeds.<\/jats:p>","DOI":"10.3389\/frobt.2026.1747721","type":"journal-article","created":{"date-parts":[[2026,3,19]],"date-time":"2026-03-19T13:36:18Z","timestamp":1773927378000},"update-policy":"https:\/\/doi.org\/10.3389\/crossmark-policy","source":"Crossref","is-referenced-by-count":0,"title":["Fast walking with swing extension assistance in a nominally passive semi-powered prosthetic knee"],"prefix":"10.3389","volume":"13","author":[{"given":"David M.","family":"Marsh","sequence":"first","affiliation":[{"name":"Center for Rehabilitation Engineering and Assistive Technology, Department of Mechanical Engineering, Vanderbilt University","place":["Nashville, TN, United States"]}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Aaron","family":"Haake","sequence":"additional","affiliation":[{"name":"Center for Rehabilitation Engineering and Assistive Technology, Department of Mechanical Engineering, Vanderbilt University","place":["Nashville, TN, United States"]}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Michael","family":"Goldfarb","sequence":"additional","affiliation":[{"name":"Center for Rehabilitation Engineering and Assistive Technology, Department of Mechanical Engineering, Vanderbilt University","place":["Nashville, TN, United States"]}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"1965","published-online":{"date-parts":[[2026,3,19]]},"reference":[{"key":"B1","first-page":"3198","article-title":"Design and preliminary assessment of lightweight swing-assist knee prosthesis","volume-title":"2018 40th annual international conference of the IEEE engineering in medicine and biology society (EMBC). 2018 40th annual international conference of the IEEE engineering in medicine and biology Society (EMBC)","author":"Baimyshev","year":"2018"},{"key":"B2","doi-asserted-by":"publisher","first-page":"490","DOI":"10.1109\/TMRB.2022.3161068","article-title":"Design and assist-as-needed control of a lightly powered prosthetic knee","volume":"4","author":"Bartlett","year":"2022","journal-title":"IEEE Trans. Med. Robotics Bionics"},{"key":"B3","doi-asserted-by":"publisher","first-page":"2151","DOI":"10.1109\/TRO.2022.3226887","article-title":"Data-Driven variable impedance control of a powered knee\u2013ankle prosthesis for adaptive speed and incline walking","volume":"39","author":"Best","year":"2023","journal-title":"IEEE Trans. Robotics"},{"key":"B4","doi-asserted-by":"publisher","first-page":"217","DOI":"10.2340\/165019771994264217223","article-title":"The gait of unilateral transfemoral amputees","volume":"26","author":"Boonstra","year":"1994","journal-title":"J. Rehabilitation Med."},{"key":"B5","doi-asserted-by":"publisher","first-page":"110320","DOI":"10.1016\/j.jbiomech.2021.110320","article-title":"A comprehensive, open-source dataset of lower limb biomechanics in multiple conditions of stairs, ramps, and level-ground ambulation and transitions","volume":"119","author":"Camargo","year":"2021","journal-title":"J. Biomechanics"},{"key":"B6","doi-asserted-by":"publisher","first-page":"1034","DOI":"10.1109\/TMRB.2022.3216475","article-title":"A power-capable knee prosthesis with ballistic swing-phase","volume":"4","author":"Culver","year":"2022","journal-title":"IEEE Trans. Med. Robotics Bionics"},{"key":"B7","first-page":"51","article-title":"Speed-Dependent variations of lower-limb joint angles during walking. A graphic computerized method showing individual patterns","volume":"65","author":"Frigo","year":"1986","journal-title":"Am. J. Phys. Med. and Rehabilitation"},{"key":"B8","doi-asserted-by":"publisher","first-page":"3180","DOI":"10.1109\/TMECH.2023.3257194","article-title":"Mechatronic design and implementation of a low-noise powered knee prosthesis with high backdrivability","volume":"28","author":"Fu","year":"2023","journal-title":"IEEE\/ASME Trans. Mechatronics"},{"key":"B9","doi-asserted-by":"publisher","first-page":"142","DOI":"10.1016\/j.arcontrol.2023.03.003","article-title":"A review of current state-of-the-art control methods for lower-limb powered prostheses","volume":"55","author":"Gehlhar","year":"2023","journal-title":"Annu. Rev. Control"},{"key":"B10","doi-asserted-by":"publisher","first-page":"655","DOI":"10.1007\/s00421-008-0764-0","article-title":"Effect of speed on the energy cost of walking in unilateral traumatic lower limb amputees","volume":"103","author":"Genin","year":"2008","journal-title":"Eur. J. Appl. Physiology"},{"key":"B11","doi-asserted-by":"publisher","first-page":"186","DOI":"10.1080\/03093640108726601","article-title":"Consequences of non-vascular trans-femoral amputation: a survey of quality of life, prosthetic use and problems","volume":"25","author":"Hagberg","year":"2001","journal-title":"Prosthetics Orthotics International"},{"key":"B12","doi-asserted-by":"publisher","first-page":"26","DOI":"10.1097\/JPO.0b013e3181cc0e34","article-title":"Differences in the spatiotemporal parameters of transtibial and transfemoral Amputee gait","volume":"22","author":"Highsmith","year":"2010","journal-title":"JPO J. Prosthetics Orthot."},{"key":"B13","first-page":"1821","article-title":"Preliminary analysis of positive knee energy injection in A transfemoral amputee walking with A powered prosthesis","volume-title":"2018 40th annual international conference of the IEEE engineering in medicine and biology Society (EMBC). 2018 40th annual international conference of the IEEE engineering in medicine and biology Society (EMBC)","author":"Hood","year":"2018"},{"key":"B14","doi-asserted-by":"publisher","first-page":"150","DOI":"10.1038\/s41597-020-0494-7","article-title":"A kinematic and kinetic dataset of 18 above-knee amputees walking at various speeds","volume":"7","author":"Hood","year":"2020","journal-title":"Sci. Data"},{"key":"B15","doi-asserted-by":"publisher","first-page":"e0147661","DOI":"10.1371\/journal.pone.0147661","article-title":"Assessing the relative contributions of active ankle and knee assistance to the walking mechanics of transfemoral amputees using a powered prosthesis","volume":"11","author":"Ingraham","year":"2016","journal-title":"Plos One"},{"key":"B16","doi-asserted-by":"publisher","first-page":"201","DOI":"10.1007\/s00221-007-1094-x","article-title":"Walking speed, cadence and step length are selected to optimize the stability of head and pelvis accelerations","volume":"184","author":"Latt","year":"2007","journal-title":"Exp. Brain Res."},{"key":"B17","doi-asserted-by":"publisher","first-page":"e9","DOI":"10.1017\/wtc.2023.4","article-title":"The effects of swing assistance in a microprocessor-controlled transfemoral prosthesis on walking at varying speeds and grades","volume":"4","author":"Lee","year":"2023","journal-title":"Wearable Technol."},{"key":"B18","doi-asserted-by":"publisher","first-page":"175","DOI":"10.1109\/TMECH.2019.2952084","article-title":"Design of a semipowered stance-control swing-assist transfemoral prosthesis","volume":"25","author":"Lee","year":"2020","journal-title":"IEEE\/ASME Trans. Mechatronics"},{"key":"B19","doi-asserted-by":"publisher","first-page":"919","DOI":"10.1016\/j.apmr.2010.01.025","article-title":"Kinematics in the terminal swing phase of unilateral transfemoral amputees: Microprocessor-Controlled versus swing-phase control prosthetic knees","volume":"91","author":"M\u00e2aref","year":"2010","journal-title":"Archives Phys. Med. Rehabilitation"},{"key":"B20","first-page":"134","article-title":"A novel swing assistance control approach for a powered transfemoral prosthesis","volume-title":"IEEE RAS EMBS 10th international conference on biomedical robotics and biomechatronics","author":"Marsh","year":""},{"key":"B21","doi-asserted-by":"publisher","first-page":"4052","DOI":"10.1109\/TNSRE.2024.3495517","article-title":"A swing-assist controller for enhancing knee flexion in a semi-powered transfemoral prosthesis","volume":"32","author":"Marsh","year":"","journal-title":"IEEE Trans. Neural Syst. Rehabilitation Eng."},{"key":"B22","doi-asserted-by":"publisher","first-page":"49","DOI":"10.1016\/0021-9290(80)90007-X","article-title":"Ballistic walking","volume":"13","author":"Mochon","year":"","journal-title":"J. Biomechanics"},{"key":"B23","doi-asserted-by":"publisher","first-page":"241","DOI":"10.1016\/0025-5564(80)90070-X","article-title":"Ballistic walking: an improved model","volume":"52","author":"Mochon","year":"","journal-title":"Math. Biosci."},{"key":"B24","doi-asserted-by":"publisher","first-page":"085009","DOI":"10.1088\/0964-1726\/25\/8\/085009","article-title":"Design and control of a prosthetic leg for above-knee amputees operated in semi-active and active modes","volume":"25","author":"Park","year":"2016","journal-title":"Smart Mater. Struct."},{"key":"B25","doi-asserted-by":"publisher","first-page":"263","DOI":"10.1177\/0278364907084588","article-title":"Design and control of a powered transfemoral prosthesis","volume":"27","author":"Sup","year":"2008","journal-title":"Int. J. Robotics Res."},{"key":"B26","doi-asserted-by":"publisher","first-page":"508","DOI":"10.1097\/PXR.0000000000000448","article-title":"The biomechanical effect of different spring extension assist mechanisms in mechanical 4-bar polycentric prosthetic knees for unilateral above\/through-knee amputees","volume":"49","author":"Toderita","year":"2025","journal-title":"Prosthetics and Orthot. Int. Prepr."},{"key":"B27","doi-asserted-by":"publisher","first-page":"eabo3996","DOI":"10.1126\/scirobotics.abo3996","article-title":"A lightweight robotic leg prosthesis replicating the biomechanics of the knee, ankle, and toe joint","volume":"7","author":"Tran","year":"2022","journal-title":"Sci. Robotics"},{"key":"B28","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1186\/1743-0003-12-1","article-title":"Control strategies for active lower extremity prosthetics and orthotics: a review","volume":"12","author":"Tucker","year":"2015","journal-title":"J. NeuroEngineering Rehabilitation"}],"container-title":["Frontiers in Robotics and AI"],"original-title":[],"link":[{"URL":"https:\/\/www.frontiersin.org\/articles\/10.3389\/frobt.2026.1747721\/full","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,3,19]],"date-time":"2026-03-19T13:36:19Z","timestamp":1773927379000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.frontiersin.org\/articles\/10.3389\/frobt.2026.1747721\/full"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,3,19]]},"references-count":28,"alternative-id":["10.3389\/frobt.2026.1747721"],"URL":"https:\/\/doi.org\/10.3389\/frobt.2026.1747721","relation":{},"ISSN":["2296-9144"],"issn-type":[{"value":"2296-9144","type":"electronic"}],"subject":[],"published":{"date-parts":[[2026,3,19]]},"article-number":"1747721"}}