{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,27]],"date-time":"2026-10-27T10:09:34Z","timestamp":1793095774304,"version":"4.5.0"},"reference-count":40,"publisher":"Frontiers Media SA","license":[{"start":{"date-parts":[[2021,10,7]],"date-time":"2021-10-07T00:00:00Z","timestamp":1633564800000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"content-domain":{"domain":["frontiersin.org"],"crossmark-restriction":true},"short-container-title":["Front. Bioeng. Biotechnol."],"abstract":"<jats:p><jats:bold>Background and context:<\/jats:bold> Surgical procedures are evolving toward less invasive and more tailored approaches to consider the specific pathology, morphology, and life habits of a patient. However, these new surgical methods require thorough preoperative planning and an advanced understanding of biomechanical behaviors. In this sense, patient-specific modeling is developing in the form of digital twins to help personalized clinical decision-making.<\/jats:p><jats:p><jats:bold>Purpose:<\/jats:bold> This study presents a patient-specific finite element model approach, focusing on tibial plateau fractures, to enhance biomechanical knowledge to optimize surgical trauma procedures and improve decision-making in postoperative management.<\/jats:p><jats:p><jats:bold>Study design:<\/jats:bold> This is a level 5 study.<\/jats:p><jats:p><jats:bold>Methods:<\/jats:bold> We used a postoperative 3D X-ray image of a patient who suffered from depression and separation of the lateral tibial plateau. The surgeon stabilized the fracture with polymethyl methacrylate cement injection and bi-cortical screw osteosynthesis. A digital twin of the patient\u2019s fracture was created by segmentation. From the digital twin, four stabilization methods were modeled including two screw lengths, whether or not, to inject PMMA cement. The four stabilization methods were associated with three bone healing conditions resulting in twelve scenarios. Mechanical strength, stress distribution, interfragmentary strains, and fragment kinematics were assessed by applying the maximum load during gait. Repeated fracture risks were evaluated regarding to the volume of bone with stress above the local yield strength and regarding to the interfragmentary strains.<\/jats:p><jats:p><jats:bold>Results:<\/jats:bold> Stress distribution analysis highlighted the mechanical contribution of cement injection and the favorable mechanical response of uni-cortical screw compared to bi-cortical screw. Evaluation of repeated fracture risks for this clinical case showed fracture instability for two of the twelve simulated scenarios.<\/jats:p><jats:p><jats:bold>Conclusion:<\/jats:bold> This study presents a patient-specific finite element modeling workflow to assess the biomechanical behaviors associated with different stabilization methods of tibial plateau fractures. Strength and interfragmentary strains were evaluated to quantify the mechanical effects of surgical procedures. We evaluate repeated fracture risks and provide data for postoperative management.<\/jats:p>","DOI":"10.3389\/fbioe.2021.722275","type":"journal-article","created":{"date-parts":[[2021,10,9]],"date-time":"2021-10-09T00:38:05Z","timestamp":1633739885000},"update-policy":"https:\/\/doi.org\/10.3389\/crossmark-policy","source":"Crossref","is-referenced-by-count":97,"title":["Development of Digital Twins to Optimize Trauma Surgery and Postoperative Management. A Case Study Focusing on Tibial Plateau Fracture"],"prefix":"10.3389","volume":"9","author":[{"given":"K\u00e9vin","family":"Aubert","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Arnaud","family":"Germaneau","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Michel","family":"Rochette","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Wenfeng","family":"Ye","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Mathieu","family":"Severyns","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Maxime","family":"Billot","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Philippe","family":"Rigoard","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Tanguy","family":"Vendeuvre","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"1965","published-online":{"date-parts":[[2021,10,7]]},"reference":[{"key":"B1","doi-asserted-by":"publisher","first-page":"S13","DOI":"10.1080\/10255842.2017.1382837","article-title":"Finite Element Analysis of Mechanical Behavior of Stabilization Techniques for Tibial Plateau Fractures","volume":"20","author":"Belaid","year":"2017","journal-title":"Comput. Methods Biomech. Biomed. Eng."},{"key":"B2","doi-asserted-by":"publisher","first-page":"27","DOI":"10.1016\/j.clinbiomech.2018.05.002","article-title":"Utility of Cement Injection to Stabilize Split-Depression Tibial Plateau Fracture by Minimally Invasive Methods: A Finite Element Analysis","volume":"56","author":"Belaid","year":"2018","journal-title":"Clin. Biomech."},{"key":"B3","doi-asserted-by":"publisher","first-page":"1263","DOI":"10.1111\/j.1532-5415.2004.52354.x","article-title":"Prevalence and Outcomes of Low Mobility in Hospitalized Older Patients","volume":"52","author":"Brown","year":"2004","journal-title":"J. Am. Geriatr. Soc."},{"key":"B4","volume-title":"AO Principles of Fracture Management","author":"Buckley","year":"2017"},{"key":"B5","doi-asserted-by":"publisher","first-page":"1477","DOI":"10.1016\/j.jbiomech.2013.03.022","article-title":"Finite Element Modeling Mesh Quality, Energy Balance and Validation Methods: A Review with Recommendations Associated with the Modeling of Bone Tissue","volume":"46","author":"Burkhart","year":"2013","journal-title":"J. of Biomech."},{"key":"B6","doi-asserted-by":"publisher","first-page":"756","DOI":"10.1007\/s00167-017-4428-7","article-title":"An Intact Fibula May Contribute to Allow Early Weight Bearing in Surgically Treated Tibial Plateau Fractures","volume":"26","author":"Carrera","year":"2018","journal-title":"Knee Surg. Sports Traumatol. Arthrosc."},{"key":"B7","doi-asserted-by":"publisher","first-page":"2163","DOI":"10.1007\/s00264-015-3106-y","article-title":"Fixation of a Split Fracture of the Lateral Tibial Plateau with a Locking Screw Plate Instead of Cannulated Screws Would Allow Early Weight Bearing: a Computational Exploration","volume":"40","author":"Carrera","year":"2016","journal-title":"Int. Orthopaedics (Sicot)"},{"key":"B8","doi-asserted-by":"publisher","first-page":"991","DOI":"10.1016\/j.medengphy.2010.06.014","article-title":"Fracture Toughness and Compressive Properties of Cancellous Bone at the Head of the Femur and Relationships to Non-invasive Skeletal Assessment Measurements","volume":"32","author":"Cook","year":"2010","journal-title":"Med. Eng. Phys."},{"key":"B9","doi-asserted-by":"publisher","first-page":"402","DOI":"10.1111\/j.1600-0501.2005.01156.x","article-title":"Positive Effect of Early Loading on Implant Stability in the Bi-cortical guinea-pig Model","volume":"16","author":"De Smet","year":"2005","journal-title":"Clin. Oral Implants Res."},{"key":"B10","doi-asserted-by":"publisher","first-page":"1257","DOI":"10.1007\/s00068-020-01538-3","article-title":"Biomechanical Aspects of the Posteromedial Split in Bicondylar Tibial Plateau Fractures-A Finite-Element Investigation","volume":"46","author":"Dehoust","year":"2020","journal-title":"Eur. J. Trauma Emerg. Surg."},{"key":"B11","doi-asserted-by":"publisher","first-page":"399","DOI":"10.1097\/BOT.0b013e318178417e","article-title":"Biomechanical Comparison of Bicortical Versus Unicortical Screw Placement of Proximal Tibia Locking Plates: A Cadaveric Model","volume":"22","author":"Dougherty","year":"2008","journal-title":"J. Orthop. Trauma"},{"key":"B12","doi-asserted-by":"publisher","first-page":"e780","DOI":"10.3928\/01477447-20150902-55","article-title":"Population-based Epidemiology of Tibial Plateau Fractures","volume":"38","author":"Elsoe","year":"2015","journal-title":"Orthopedics"},{"key":"B13","doi-asserted-by":"publisher","first-page":"S3","DOI":"10.1016\/S0020-1383(08)70003-2","article-title":"Fracture Healing: The diamond Concept","volume":"38","author":"Giannoudis","year":"2007","journal-title":"Injury"},{"key":"B14","doi-asserted-by":"publisher","first-page":"768","DOI":"10.3928\/01477447-20120822-04","article-title":"Percutaneous Inflation Osteoplasty for Indirect Reduction of Depressed Tibial Plateau Fractures","volume":"35","author":"Hahnhaussen","year":"2012","journal-title":"Orthopedics"},{"key":"B15","doi-asserted-by":"publisher","first-page":"101","DOI":"10.4103\/2277-9175.129375","article-title":"Insights into the Effects of Tensile and Compressive Loadings on Human Femur Bone","volume":"3","author":"Havaldar","year":"2014","journal-title":"Adv. Biomed. Res."},{"key":"B16","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1155\/2015\/204842","article-title":"Improved Fracture Healing in Patients with Concomitant Traumatic Brain Injury: Proven or Not?","volume":"2015","author":"Hofman","year":"2015","journal-title":"Mediators of Inflamm."},{"key":"B17","doi-asserted-by":"publisher","first-page":"182","DOI":"10.1186\/s13018-015-0325-2","article-title":"Stress and Stability of Plate-Screw Fixation and Screw Fixation in the Treatment of Schatzker Type IV Medial Tibial Plateau Fracture: a Comparative Finite Element Study","volume":"10","author":"Huang","year":"2015","journal-title":"J. Orthop. Surg. Res."},{"key":"B18","doi-asserted-by":"publisher","first-page":"4941","DOI":"10.3390\/app10144941","article-title":"Influence of the Screw Positioning on the Stability of Locking Plate for Proximal Tibial Fractures: A Numerical Approach","volume":"10","author":"Ingrassia","year":"2020","journal-title":"Appl. Sci."},{"key":"B19","doi-asserted-by":"publisher","first-page":"2252","DOI":"10.1016\/j.injury.2018.11.010","article-title":"Revisiting the Schatzker Classification of Tibial Plateau Fractures","volume":"49","author":"Kfuri","year":"2018","journal-title":"Injury"},{"key":"B20","doi-asserted-by":"crossref","first-page":"277","DOI":"10.1007\/978-1-4614-7657-3_19","article-title":"3D Slicer: A Platform for Subject-Specific Image Analysis, Visualization, and Clinical Support","volume-title":"Intraoperative Imaging And Image-Guided Therapy","author":"Kikinis","year":"2014"},{"key":"B21","doi-asserted-by":"publisher","first-page":"281","DOI":"10.1186\/s12891-018-2209-1","article-title":"Duration of Incapacity of Work after Tibial Plateau Fracture Is Affected by Work Intensity","volume":"19","author":"Kraus","year":"2018","journal-title":"BMC Musculoskelet. Disord."},{"key":"B22","doi-asserted-by":"publisher","first-page":"1163","DOI":"10.1016\/S0021-9290(02)00086-6","article-title":"A Mechano-Regulation Model for Tissue Differentiation during Fracture Healing: Analysis of gap Size and Loading","volume":"35","author":"Lacroix","year":"2002","journal-title":"J. of Biomech."},{"key":"B23","doi-asserted-by":"crossref","first-page":"60","DOI":"10.1007\/3-540-28924-0_6","article-title":"The Mechanical Properties of PMMA Bone Cement","volume-title":"The Well-Cemented Total Hip Arthroplasty: Theory and Practice","author":"Lee","year":"2005"},{"key":"B24","doi-asserted-by":"publisher","first-page":"1065","DOI":"10.1016\/S0167-8655(97)00131-1","article-title":"An Improved Seeded Region Growing Algorithm","volume":"18","author":"Mehnert","year":"1997","journal-title":"Pattern Recognition Lett."},{"key":"B25","doi-asserted-by":"publisher","first-page":"S1","DOI":"10.1097\/BOT.0000000000001063","article-title":"Fracture and Dislocation Classification Compendium-2018","volume":"32","author":"Meinberg","year":"2018","journal-title":"J. Orthop. Trauma"},{"key":"B26","doi-asserted-by":"publisher","first-page":"703","DOI":"10.1016\/j.clinbiomech.2015.05.002","article-title":"Prediction of Local Proximal Tibial Subchondral Bone Structural Stiffness Using Subject-specific Finite Element Modeling: Effect of Selected Density-Modulus Relationship","volume":"30","author":"Nazemi","year":"2015","journal-title":"Clin. Biomech."},{"key":"B27","doi-asserted-by":"publisher","first-page":"1745","DOI":"10.2217\/nnm.14.109","article-title":"Nanomaterials: the Next Step in Injectable Bone Cements","volume":"9","author":"No","year":"2014","journal-title":"Nanomedicine"},{"key":"B28","doi-asserted-by":"publisher","first-page":"135","DOI":"10.1016\/j.knee.2010.12.008","article-title":"Role of the Anterior Intermeniscal Ligament in Tibiofemoral Contact Mechanics during Axial Joint Loading","volume":"19","author":"Poh","year":"2012","journal-title":"The Knee"},{"key":"B29","doi-asserted-by":"publisher","first-page":"347","DOI":"10.1016\/1350-4533(95)97314-F","article-title":"Relations of Mechanical Properties to Density and CT Numbers in Human Bone","volume":"17","author":"Rho","year":"1995","journal-title":"Med. Eng. Phys."},{"key":"B30","doi-asserted-by":"publisher","first-page":"126","DOI":"10.1177\/2151458516651310","article-title":"Tibial Plateau Fractures in Elderly Patients","volume":"7","author":"Rozell","year":"2016","journal-title":"Geriatr. Orthop. Surg. Rehabil."},{"key":"B31","first-page":"868","article-title":"AO Principles of Fracture Management","author":"Ruedi","year":"2000","journal-title":"AO Princ. Fract. Manag."},{"key":"B32","doi-asserted-by":"publisher","first-page":"1271","DOI":"10.1302\/0301-620X.102B10.BJJ-2020-0827.R1","article-title":"Distinguishing Fact from Fiction in Finite Element Analysis","author":"Scott","year":"2020","journal-title":"Bone Jt. J."},{"key":"B33","doi-asserted-by":"publisher","first-page":"422","DOI":"10.1002\/jor.1100090315","article-title":"Estimation of Mechanical Properties of Cortical Bone by Computed Tomography","volume":"9","author":"Snyder","year":"1991","journal-title":"J. Orthop. Res."},{"key":"B34","doi-asserted-by":"publisher","first-page":"157","DOI":"10.1016\/j.jcot.2013.11.005","article-title":"Bone Cement","volume":"4","author":"Vaishya","year":"2013","journal-title":"J. of Clin. Orthopaedics Trauma"},{"key":"B35","doi-asserted-by":"publisher","first-page":"1071","DOI":"10.1007\/s00402-017-2718-7","article-title":"Is the AO Guideline for Postoperative Treatment of Tibial Plateau Fractures Still Decisive? A Survey Among Orthopaedic Surgeons and Trauma Surgeons in the Netherlands","volume":"137","author":"Van Der Vusse","year":"2017","journal-title":"Arch. Orthop. Trauma Surg."},{"key":"B36","doi-asserted-by":"publisher","first-page":"S267","DOI":"10.1016\/j.otsr.2013.03.009","article-title":"Tuberoplasty: Minimally Invasive Osteosynthesis Technique for Tibial Plateau Fractures","volume":"99","author":"Vendeuvre","year":"2013","journal-title":"Orthopaedics Traumatol. Surg. Res."},{"key":"B37","doi-asserted-by":"publisher","first-page":"27","DOI":"10.1016\/j.clinbiomech.2018.08.004","article-title":"Contribution of Minimally Invasive Bone Augmentation to Primary Stabilization of the Osteosynthesis of Schatzker Type II Tibial Plateau Fractures: Balloon vs Bone Tamp","volume":"59","author":"Vendeuvre","year":"2018","journal-title":"Clin. Biomech."},{"key":"B38","doi-asserted-by":"publisher","first-page":"e026962","DOI":"10.1136\/bmjopen-2018-026962","article-title":"Comparative Evaluation of Minimally Invasive 'tibial Tuberoplasty' Surgical Technique versus Conventional Open Surgery for Schatzker II-III Tibial Plateau Fractures: Design of a Multicentre, Randomised, Controlled and Blinded Trial (TUBERIMPACT Study)","volume":"9","author":"Vendeuvre","year":"2019","journal-title":"BMJ Open"},{"key":"B39","first-page":"1","article-title":"Concept of the Law of Bone Remodelling","volume-title":"The Law of Bone Remodelling","author":"Wolff","year":"1986"},{"key":"B40","doi-asserted-by":"publisher","first-page":"789","DOI":"10.1002\/jor.20379","article-title":"Correlation between the Knee Adduction Torque and Medial Contact Force for a Variety of Gait Patterns","volume":"25","author":"Zhao","year":"2007","journal-title":"J. Orthop. Res."}],"container-title":["Frontiers in Bioengineering and Biotechnology"],"original-title":[],"link":[{"URL":"https:\/\/www.frontiersin.org\/articles\/10.3389\/fbioe.2021.722275\/full","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2021,10,9]],"date-time":"2021-10-09T00:38:23Z","timestamp":1633739903000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.frontiersin.org\/articles\/10.3389\/fbioe.2021.722275\/full"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2021,10,7]]},"references-count":40,"alternative-id":["10.3389\/fbioe.2021.722275"],"URL":"https:\/\/doi.org\/10.3389\/fbioe.2021.722275","relation":{},"ISSN":["2296-4185"],"issn-type":[{"value":"2296-4185","type":"electronic"}],"subject":[],"published":{"date-parts":[[2021,10,7]]},"article-number":"722275"}}