{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,11,20]],"date-time":"2026-11-20T19:55:37Z","timestamp":1795204537801,"version":"4.10.3"},"reference-count":32,"publisher":"Frontiers Media SA","license":[{"start":{"date-parts":[[2021,10,8]],"date-time":"2021-10-08T00:00:00Z","timestamp":1633651200000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"content-domain":{"domain":["frontiersin.org"],"crossmark-restriction":true},"short-container-title":["Front. Bioeng. Biotechnol."],"abstract":"<jats:p><jats:bold>Objective:<\/jats:bold> The interactions between aortic morphology and hemodynamics play a key role in determining type B aortic dissection (TBAD) progression and remodeling. The study aimed to provide qualitative and quantitative hemodynamic assessment in four different TBAD morphologies based on 4D flow MRI analysis.<\/jats:p><jats:p><jats:bold>Materials and Methods:<\/jats:bold> Four patients with different TBAD morphologies underwent CT and 4D flow MRI scans. Qualitative blood flow evaluation was performed by visualizing velocity streamlines and flow directionality near the tears. Quantitative analysis included flow rate, velocity and reverse flow index (RFI) measurements. Statistical analysis was performed to evaluate hemodynamic differences between the true lumen (TL) and false lumen (FL) of patients.<\/jats:p><jats:p><jats:bold>Results:<\/jats:bold> Qualitative analysis revealed blood flow splitting near the primary entry tears (PETs), often causing the formation of vortices in the FL. All patients exhibited clear hemodynamic differences between TL and FL, with the TL generally showing higher velocities and flow rates, and lower RFIs. Average velocity magnitude measurements were significantly different for Patient 1 (<jats:italic>t<\/jats:italic> = 5.61, <jats:italic>p<\/jats:italic> = 0.001), Patient 2 (<jats:italic>t<\/jats:italic> = 3.09, <jats:italic>p<\/jats:italic> = 0.02) and Patient 4 (<jats:italic>t<\/jats:italic> = 2.81, <jats:italic>p<\/jats:italic> = 0.03). At follow-up, Patient three suffered from left renal ischemia because of FL collapse. This patient presented a complex morphology with two FLs and marked flow differences between TL and FLs. In Patient 4, left renal artery malperfusion was observed at the 32-months follow-up, due to FL thrombosis growing after PET repair.<\/jats:p><jats:p><jats:bold>Conclusion:<\/jats:bold> The study demonstrates the clinical feasibility of using 4D flow MRI in the context of TBAD. Detailed patient-specific hemodynamics assessment before treatment may provide useful insights to better understand this pathology in the future.<\/jats:p>","DOI":"10.3389\/fbioe.2021.742985","type":"journal-article","created":{"date-parts":[[2021,10,10]],"date-time":"2021-10-10T13:38:09Z","timestamp":1633873089000},"update-policy":"https:\/\/doi.org\/10.3389\/crossmark-policy","source":"Crossref","is-referenced-by-count":14,"title":["Qualitative and Quantitative Assessments of Blood Flow on Tears in Type B Aortic Dissection With Different Morphologies"],"prefix":"10.3389","volume":"9","author":[{"given":"Simone","family":"Saitta","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Baolei","family":"Guo","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Selene","family":"Pirola","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Claudia","family":"Menichini","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Daqiao","family":"Guo","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Yan","family":"Shan","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Zhihui","family":"Dong","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Xiao Yun","family":"Xu","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Weiguo","family":"Fu","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"1965","published-online":{"date-parts":[[2021,10,8]]},"reference":[{"key":"B1","doi-asserted-by":"publisher","first-page":"6396","DOI":"10.1007\/s00330-019-06320-7","article-title":"Predictive Imaging for Thoracic Aortic Dissection and Rupture: Moving beyond Diameters","volume":"29","author":"Adriaans","year":"2019","journal-title":"Eur. Radiol."},{"key":"B2","doi-asserted-by":"publisher","first-page":"e180009","DOI":"10.1148\/ryct.2019180009","article-title":"Detection and Hemodynamic Evaluation of Flap Fenestrations in Type B Aortic Dissection with 4D Flow MRI: Comparison with Conventional MRI and CT Angiography","volume":"1","author":"Allen","year":"2019","journal-title":"Radiol. Cardiothorac. Imaging"},{"key":"B3","doi-asserted-by":"publisher","first-page":"2108","DOI":"10.1016\/j.jvs.2019.06.222","article-title":"Endograft Exclusion of the False Lumen Restores Local Hemodynamics in a Model of Type B Aortic Dissection","volume":"71","author":"Birjiniuk","year":"2020","journal-title":"J. Vasc. Surg."},{"key":"B4","doi-asserted-by":"publisher","first-page":"1068","DOI":"10.21037\/cdt-20-452","article-title":"4D Flow Imaging of the Thoracic Aorta: Is There an Added Clinical Value","volume":"10","author":"Catapano","year":"2020","journal-title":"Cardiovasc. Diagn. Ther."},{"key":"B5","doi-asserted-by":"publisher","first-page":"17","DOI":"10.1016\/j.diii.2018.08.012","article-title":"In-vitro Validation of 4D Flow MRI Measurements with an Experimental Pulsatile Flow Model","volume":"100","author":"David","year":"2019","journal-title":"Diagn. Interv. Imaging"},{"key":"B6","doi-asserted-by":"publisher","first-page":"3133","DOI":"10.1161\/circulationaha.111.090266","article-title":"Long-Term Outcome of Aortic Dissection with Patent False Lumen","volume":"125","author":"Evangelista","year":"2012","journal-title":"Circulation"},{"key":"B7","doi-asserted-by":"publisher","first-page":"1359","DOI":"10.1016\/j.jtcvs.2012.07.019","article-title":"Four-dimensional, Flow-Sensitive Magnetic Resonance Imaging of Blood Flow Patterns in Thoracic Aortic Dissections","volume":"145","author":"Fran\u00e7ois","year":"2013","journal-title":"J. Thorac. Cardiovasc. Surg."},{"key":"B8","doi-asserted-by":"publisher","first-page":"67","DOI":"10.1016\/j.jvscit.2017.11.005","article-title":"Hemodynamic Evaluation Using Four-Dimensional Flow Magnetic Resonance Imaging for a Patient with Multichanneled Aortic Dissection","volume":"4","author":"Guo","year":"2018","journal-title":"J. Vasc. Surg. Cases, Innov. Tech."},{"key":"B9","doi-asserted-by":"publisher","first-page":"1909","DOI":"10.1002\/mrm.25715","article-title":"Multi-VENC Acquisition of Four-Dimensional Phase-Contrast MRI to Improve Precision of Velocity Field Measurement","volume":"75","author":"Ha","year":"2016","journal-title":"Magn. Reson. Med."},{"key":"B10","doi-asserted-by":"publisher","DOI":"10.1115\/1.4045487","article-title":"Towards Estimating the Uncertainty Associated with Three-Dimensional Geometry Reconstructed from Medical Image Data","volume":"4","author":"Horner","year":"2019","journal-title":"J. verification, validation, uncertainty quantification"},{"key":"B11","doi-asserted-by":"publisher","first-page":"760","DOI":"10.1253\/jcj.64.760","article-title":"Evaluation of Flow Volume and Flow Patterns in the Patent False Lumen of Chronic Aortic Dissections Using Velocity-Encoded Cine Magnetic Resonance Imaging","volume":"64","author":"Inoue","year":"2000","journal-title":"Jpn. Circ. J."},{"key":"B12","doi-asserted-by":"publisher","first-page":"277","DOI":"10.1007\/978-1-4614-7657-3_19","article-title":"3D Slicer: a Platform for Subject-specific Image Analysis, Visualization, and Clinical Support. Intraoperative Imaging and Image-Guided Therapy","author":"Kikinis","year":"2014","journal-title":"Springer"},{"key":"B13","doi-asserted-by":"publisher","first-page":"9111","DOI":"10.1038\/s41598-018-27249-9","article-title":"Quantitative Study of Abdominal Blood Flow Patterns in Patients with Aortic Dissection by 4-dimensional Flow MRI","volume":"8","author":"Liu","year":"2018","journal-title":"Sci. Rep."},{"key":"B14","doi-asserted-by":"publisher","first-page":"779","DOI":"10.1016\/j.crad.2016.01.011","article-title":"Advanced Flow MRI: Emerging Techniques and Applications","volume":"71","author":"Markl","year":"2016","journal-title":"Clin. Radiol."},{"key":"B15","doi-asserted-by":"publisher","first-page":"641","DOI":"10.1016\/j.jvs.2011.10.025","article-title":"Volume Changes in Aortic True and False Lumen after the \u201cPETTICOAT\u201d Procedure for Type B Aortic Dissection","volume":"55","author":"Melissano","year":"2012","journal-title":"J. Vasc. Surg."},{"key":"B16","doi-asserted-by":"publisher","first-page":"559","DOI":"10.1016\/j.jvs.2011.02.017","article-title":"Tridirectional Phase-Contrast Magnetic Resonance Velocity Mapping Depicts Severe Hemodynamic Alterations in a Patient with Aortic Dissection Type Stanford B","volume":"54","author":"M\u00fcller-Eschner","year":"2011","journal-title":"J. Vasc. Surg."},{"key":"B17","doi-asserted-by":"publisher","first-page":"1462","DOI":"10.1002\/jmri.23588","article-title":"Four-dimensional Phase Contrast MRI with Accelerated Dual Velocity Encoding","volume":"35","author":"Nett","year":"2012","journal-title":"J. Magn. Reson. Imaging"},{"key":"B18","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1038\/nrdp.2016.71","article-title":"Aortic Dissection","volume":"2","author":"Nienaber","year":"2016","journal-title":"Nat. Rev. Dis. Primers"},{"key":"B19","doi-asserted-by":"publisher","first-page":"407","DOI":"10.1161\/circinterventions.113.000463","article-title":"Endovascular Repair of Type B Aortic Dissection","volume":"6","author":"Nienaber","year":"2013","journal-title":"Circ. Cardiovasc. Interv."},{"key":"B20","doi-asserted-by":"publisher","first-page":"641","DOI":"10.1016\/j.ejvs.2014.07.005","article-title":"Outcomes of Fenestrated\/branched Endografting in post-dissection Thoracoabdominal Aortic Aneurysms","volume":"48","author":"Oikonomou","year":"2014","journal-title":"Eur. J. Vasc. Endovascular Surg."},{"key":"B21","doi-asserted-by":"publisher","first-page":"710","DOI":"10.1016\/j.jvs.2018.11.038","article-title":"False Lumen Embolization in Chronic Aortic Dissection Promotes Thoracic Aortic Remodeling at Midterm Follow-Up","volume":"70","author":"Pellenc","year":"2019","journal-title":"J. Vasc. Surg."},{"key":"B22","doi-asserted-by":"publisher","first-page":"441","DOI":"10.3389\/fphys.2017.00441","article-title":"4D Flow Analysis of BAV-Related Fluid-Dynamic Alterations: Evidences of wall Shear Stress Alterations in Absence of Clinically-Relevant Aortic Anatomical Remodeling","volume":"8","author":"Piatti","year":"2017","journal-title":"Front. Physiol."},{"key":"B23","doi-asserted-by":"publisher","first-page":"3411","DOI":"10.1109\/tbme.2019.2904885","article-title":"4-D Flow MRI-Based Computational Analysis of Blood Flow in Patient-specific Aortic Dissection","volume":"66","author":"Pirola","year":"2019","journal-title":"IEEE Trans. Biomed. Eng."},{"key":"B24","doi-asserted-by":"publisher","first-page":"4","DOI":"10.1016\/j.ejvs.2016.06.005","article-title":"Editor's Choice - Management of Descending Thoracic Aorta Diseases","volume":"53","author":"Riambau","year":"2017","journal-title":"Eur. J. Vasc. Endovascular Surg."},{"key":"B25","doi-asserted-by":"publisher","first-page":"13","DOI":"10.1016\/j.jbiomech.2019.07.004","article-title":"Evaluation of 4D Flow MRI-Based Non-invasive Pressure Assessment in Aortic Coarctations","volume":"94","author":"Saitta","year":"2019","journal-title":"J. Biomech."},{"key":"B26","doi-asserted-by":"publisher","first-page":"103","DOI":"10.1146\/annurev-bioeng-100219-110055","article-title":"4D Flow with MRI","volume":"22","author":"Soulat","year":"2020","journal-title":"Annu. Rev. Biomed. Eng."},{"key":"B27","doi-asserted-by":"publisher","first-page":"II","DOI":"10.1161\/01.cir.0000138386.48852.b6","article-title":"Growth Rate of Aortic Diameter in Patients with Type B Aortic Dissection during the Chronic Phase","volume":"110","author":"Sueyoshi","year":"2004","journal-title":"Circulation"},{"key":"B28","doi-asserted-by":"publisher","first-page":"413","DOI":"10.1093\/icvts\/ivy271","article-title":"Four-dimensional Flow Magnetic Resonance Imaging Analysis before and after Thoracic Endovascular Aortic Repair of Chronic Type B Aortic Dissection","volume":"28","author":"Takei","year":"2019","journal-title":"Interactive Cardiovasc. Thorac. Surg."},{"key":"B29","doi-asserted-by":"publisher","first-page":"349","DOI":"10.1056\/nejmoa063232","article-title":"Partial Thrombosis of the False Lumen in Patients with Acute Type B Aortic Dissection","volume":"357","author":"Tsai","year":"2007","journal-title":"N. Engl. J. Med."},{"key":"B30","doi-asserted-by":"publisher","first-page":"12","DOI":"10.1016\/j.medengphy.2017.08.011","article-title":"Hemodynamic Parameters that May Predict False-Lumen Growth in Type-B Aortic Dissection after Endovascular Repair: A Preliminary Study on Long-Term Multiple Follow-Ups","volume":"50","author":"Xu","year":"2017","journal-title":"Med. Eng. Phys."},{"key":"B31","doi-asserted-by":"publisher","first-page":"61","DOI":"10.1093\/bmb\/ldw049","article-title":"Functional Assessment of Thoracic Aortic Aneurysms - the Future of Risk Prediction","volume":"121","author":"Youssefi","year":"2017","journal-title":"Br. Med. Bull."},{"key":"B32","doi-asserted-by":"publisher","first-page":"e200456","DOI":"10.1148\/ryct.2021200456","article-title":"Noninvasive Morphologic and Hemodynamic Evaluation of Type B Aortic Dissection: State of the Art and Future Perspectives","volume":"3","author":"Zilber","year":"2021","journal-title":"Radiol. Cardiothorac. Imaging"}],"container-title":["Frontiers in Bioengineering and Biotechnology"],"original-title":[],"link":[{"URL":"https:\/\/www.frontiersin.org\/articles\/10.3389\/fbioe.2021.742985\/full","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2021,10,10]],"date-time":"2021-10-10T13:38:14Z","timestamp":1633873094000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.frontiersin.org\/articles\/10.3389\/fbioe.2021.742985\/full"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2021,10,8]]},"references-count":32,"alternative-id":["10.3389\/fbioe.2021.742985"],"URL":"https:\/\/doi.org\/10.3389\/fbioe.2021.742985","relation":{},"ISSN":["2296-4185"],"issn-type":[{"value":"2296-4185","type":"electronic"}],"subject":[],"published":{"date-parts":[[2021,10,8]]},"article-number":"742985"}}