{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,7,24]],"date-time":"2026-07-24T04:55:59Z","timestamp":1784868959213,"version":"3.55.0"},"reference-count":102,"publisher":"Frontiers Media SA","license":[{"start":{"date-parts":[[2022,2,17]],"date-time":"2022-02-17T00:00:00Z","timestamp":1645056000000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"funder":[{"DOI":"10.13039\/501100010248","name":"Zhejiang Province Public Welfare Technology Application Research Project","doi-asserted-by":"publisher","id":[{"id":"10.13039\/501100010248","id-type":"DOI","asserted-by":"publisher"}]}],"content-domain":{"domain":["frontiersin.org"],"crossmark-restriction":true},"short-container-title":["Front. Bioeng. Biotechnol."],"abstract":"<jats:p>It is occasionally essential to surgically remove the damaged eye of the patient in the case of serious oculoorbital injuries, intraocular cancers, and other life-threatening diseases. An orbital implant is placed into the anophthalmic socket after the eye is removed to provide adequate volume reinstatement and revamp the cosmetic look of a normal eye. In the previous few decades, implant design and material selection criteria have progressed from basic nonporous polymeric spheres to devices with more complicated shapes and functions to ensure improved long-term clinical results. Because of their highly interconnected porous design, ceramic and polymeric porous implants have found popularity as a passive framework for fibrovascular ingrowth, with lower obstacle rates and the option of setting to improve prosthetic eye mobility. These materials, however, are not without flaws. The danger of migration and extrusion, infections after surgery, and poor motility transferred to the cosmetic ocular prosthesis are important elements of orbital implants of today. As a result, the development of novel biomaterials with improved functionalities (i.e., antibacterial effect, angiogenesis, and <jats:italic>in situ<\/jats:italic> moldability) that allow better eye replacement is more desirable than ever, highlighting one of the most challenging aspects of research topics in the field of ocular implants. This study highlights the history of orbital implants. It gives an outline of current advancements in the area, over and above some essential observations for materials design, selection, characterization, and transformation to clinical applications.<\/jats:p>","DOI":"10.3389\/fbioe.2021.800998","type":"journal-article","created":{"date-parts":[[2022,2,17]],"date-time":"2022-02-17T09:24:38Z","timestamp":1645089878000},"update-policy":"https:\/\/doi.org\/10.3389\/crossmark-policy","source":"Crossref","is-referenced-by-count":40,"title":["The Evolution of Orbital Implants and Current Breakthroughs in Material Design, Selection, Characterization, and Clinical Use"],"prefix":"10.3389","volume":"9","author":[{"given":"Xiao-Yi","family":"Chen","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Xue","family":"Yang","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Xing-Li","family":"Fan","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"1965","published-online":{"date-parts":[[2022,2,17]]},"reference":[{"key":"B1","doi-asserted-by":"publisher","first-page":"925","DOI":"10.1007\/s00234-014-1403-6","article-title":"Post-operative Orbital Imaging: a Focus on Implants and Prosthetic Devices","volume":"56","author":"Adams","year":"2014","journal-title":"Neuroradiology"},{"key":"B2","doi-asserted-by":"publisher","first-page":"455","DOI":"10.1097\/01.iop.0000092795.83665.fd","article-title":"Use of Bioglass for Orbital Volume Augmentation in Enophthalmos","volume":"19","author":"Amato","year":"2003","journal-title":"Ophthalmic Plast. Reconstr. Surg."},{"key":"B3","doi-asserted-by":"publisher","first-page":"315","DOI":"10.1136\/bjo.67.5.315","article-title":"Magnetic Orbital Implants","volume":"67","author":"Atkins","year":"1983","journal-title":"Br. J. Ophthalmol."},{"key":"B4","doi-asserted-by":"publisher","first-page":"753","DOI":"10.1080\/09654310701214226","article-title":"Strategic Considerations for Innovation and Commercialization in the US Biotechnology Sector","volume":"15","author":"Bagchi-Sen","year":"2007","journal-title":"Eur. Plann. Stud."},{"key":"B5","doi-asserted-by":"publisher","first-page":"3248","DOI":"10.1016\/j.actbio.2011.05.016","article-title":"Biomaterials and Implants for Orbital Floor Repair","volume":"7","author":"Baino","year":"2011","journal-title":"Acta Biomater."},{"key":"B6","doi-asserted-by":"publisher","first-page":"1064","DOI":"10.1016\/j.actbio.2013.12.014","article-title":"Biomaterials for Orbital Implants and Ocular Prostheses: Overview and Future Prospects","volume":"10","author":"Baino","year":"2014","journal-title":"Acta Biomater."},{"key":"B7","doi-asserted-by":"publisher","first-page":"1410","DOI":"10.1016\/j.msec.2016.08.003","article-title":"Orbital Implants: State-Of-The-Art Review with Emphasis on Biomaterials and Recent Advances","volume":"69","author":"Baino","year":"2016","journal-title":"Mater. Sci. Eng. C"},{"key":"B8","doi-asserted-by":"publisher","first-page":"945","DOI":"10.1016\/j.medengphy.2010.07.007","article-title":"Scleral Buckling Biomaterials and Implants for Retinal Detachment Surgery","volume":"32","author":"Baino","year":"2010","journal-title":"Med. Eng. Phys."},{"key":"B9","doi-asserted-by":"publisher","first-page":"921","DOI":"10.1016\/j.actbio.2010.10.030","article-title":"Towards an Ideal Biomaterial for Vitreous Replacement: Historical Overview and Future Trends","volume":"7","author":"Baino","year":"2011","journal-title":"Acta Biomater."},{"key":"B10","doi-asserted-by":"publisher","first-page":"63","DOI":"10.1016\/j.mser.2010.05.002","article-title":"Polymers in Modern Ophthalmic Implants-Historical Background and Recent Advances","volume":"69","author":"Bozukova","year":"2010","journal-title":"Mater. Sci. Eng. R: Rep."},{"key":"B11","doi-asserted-by":"publisher","first-page":"145","DOI":"10.1016\/j.survophthal.2006.12.007","article-title":"Porous Orbital Implants in Enucleation: A Systematic Review","volume":"52","author":"Chalasani","year":"2007","journal-title":"Surv. Ophthalmol."},{"key":"B12","doi-asserted-by":"publisher","first-page":"1530","DOI":"10.1136\/bjophthalmol-2013-303481","article-title":"Outcome of Smooth Surface Tunnel Porous Polyethylene Orbital Implants (Medpor SST) in Children with Retinoblastoma","volume":"97","author":"Choi","year":"2013","journal-title":"Br. J. Ophthalmol."},{"key":"B13","first-page":"223","article-title":"Use of Proplast II","volume":"7","author":"Christenbury","year":"1991","journal-title":"Ophthalmic Plast. Reconstr. Surg."},{"key":"B14","doi-asserted-by":"publisher","first-page":"1199","DOI":"10.1001\/archopht.116.9.1199","article-title":"Intraorbital Implants after Enucleation and Their Complications","volume":"116","author":"Christmas","year":"1998","journal-title":"Arch. Ophthalmol."},{"key":"B15","doi-asserted-by":"publisher","first-page":"572","DOI":"10.1007\/s00347-013-2950-7","article-title":"Por\u00f6se Orbitaimplantate","volume":"111","author":"Cleres","year":"2014","journal-title":"Ophthalmologe"},{"key":"B16","doi-asserted-by":"publisher","first-page":"014105","DOI":"10.1088\/1748-6041\/11\/1\/014105","article-title":"Mechanical Behaviour of Degradable Phosphate Glass Fibres and Composites-A Review","volume":"11","author":"Colquhoun","year":"2015","journal-title":"Biomed. Mater."},{"key":"B17","first-page":"17","article-title":"Orbital Implants after Enucleation; Basic Principles of Anatomy and Physiology of the Orbit and Relation to Implant Surgery","volume":"56","author":"Culler","year":"1952","journal-title":"Trans. Am. Acad. Ophthalmol. Otolaryngol."},{"key":"B18","doi-asserted-by":"publisher","first-page":"513","DOI":"10.1016\/s0161-6420(99)90109-4","article-title":"Comparative Motility of Hydroxyapatite and Alloplastic Enucleation Implants","volume":"106","author":"Custer","year":"1999","journal-title":"Ophthalmology"},{"key":"B19","doi-asserted-by":"publisher","first-page":"53","DOI":"10.3928\/1542-8877-19910101-15","article-title":"Orbital Volume Augmentation with Adjustable Prefabricated Methylmethacrylate Subperiosteal Implants","volume":"22","author":"Dresner","year":"1991","journal-title":"Ophthalmic Surg. Lasers Imaging"},{"key":"B20","doi-asserted-by":"publisher","first-page":"308","DOI":"10.1016\/j.ijom.2014.12.002","article-title":"Controversies in Orbital Reconstruction-I. Defect-Driven Orbital Reconstruction: A Systematic Review","volume":"44","author":"Dubois","year":"2015","journal-title":"Int. J. Oral Maxillofacial Surg."},{"key":"B21","doi-asserted-by":"publisher","first-page":"433","DOI":"10.1016\/j.ijom.2014.12.003","article-title":"Controversies in Orbital Reconstruction-II. Timing of post-traumatic Orbital Reconstruction: A Systematic Review","volume":"44","author":"Dubois","year":"2015","journal-title":"Int. J. Oral Maxillofacial Surg."},{"key":"B22","doi-asserted-by":"publisher","first-page":"352","DOI":"10.1001\/archopht.1956.00930040360004","article-title":"A New Magnetic Orbital Implant","volume":"56","author":"Ellis","year":"1956","journal-title":"Arch. Ophthalmol."},{"key":"B23","doi-asserted-by":"publisher","first-page":"e277","DOI":"10.5301\/jabfm.5000283","article-title":"Catapano G: Bone Structural Similarity Score: a Multiparametric Tool to Match Properties of Biomimetic Bone Substitutes with Their Target Tissues","volume":"14","author":"Falvo D'Urso Labate","year":"2016","journal-title":"J. Appl. Biomater. Funct. Mater."},{"key":"B24","doi-asserted-by":"publisher","first-page":"43","DOI":"10.3389\/fbioe.2016.00043","article-title":"Lost in Translation: The Gap in Scientific Advancements and Clinical Application","volume":"4","author":"Fernandez-Moure","year":"2016","journal-title":"Front. Bioeng. Biotechnol."},{"key":"B25","doi-asserted-by":"publisher","first-page":"948","DOI":"10.5301\/ejo.5000469","article-title":"Scleral Shield: Primary Results of a New Surgical Technique in Augmenting Porous Orbital Implant protection","volume":"24","author":"Gawdat","year":"2014","journal-title":"Eur. J. Ophthalmol."},{"key":"B26","doi-asserted-by":"publisher","first-page":"121","DOI":"10.1111\/aos.12004","article-title":"Enucleation in Iceland 1992-2004: Study in a Defined Population","volume":"92","author":"Geirsdottir","year":"2014","journal-title":"Acta Ophthalmologica"},{"key":"B27","doi-asserted-by":"publisher","first-page":"3640","DOI":"10.3390\/ijms15033640","article-title":"An Overview of Poly(lactic-Co-Glycolic) Acid (PLGA)-Based Biomaterials for Bone Tissue Engineering","volume":"15","author":"Gentile","year":"2014","journal-title":"Ijms"},{"key":"B28","doi-asserted-by":"publisher","first-page":"141","DOI":"10.1097\/00002341-199006000-00014","article-title":"Buried Quasi-Integrated Enucleation Implant of Proplast II. A Preliminary Report","volume":"6","author":"Girard","year":"1990","journal-title":"Ophthalmic Plast. Reconstr. Surg."},{"key":"B29","doi-asserted-by":"publisher","first-page":"139","DOI":"10.1097\/00002341-199006000-00013","article-title":"Evisceration Implant of Proplast II. A Preliminary Report","volume":"6","author":"Girard","year":"1990","journal-title":"Ophthalmic Plast. Reconstr. Surg."},{"key":"B30","first-page":"198","article-title":"Prevention of Postenucleation Syndrome: the Hydroxylapatite Silicone Implant. Preliminary Experimental Studies and Initial Clinical Experiences","volume":"92","author":"Guthoff","year":"1995","journal-title":"Ophthalmologe"},{"key":"B31","doi-asserted-by":"publisher","first-page":"229","DOI":"10.1007\/bf01575515","article-title":"Aesthetic Considerations in the Reconstruction of the Anophthalmic Orbit","volume":"11","author":"Habal","year":"1987","journal-title":"Aesth. Plast. Surg."},{"key":"B32","doi-asserted-by":"publisher","first-page":"136","DOI":"10.1097\/iop.0000000000000228","article-title":"Dermis Fat Graft Implantation after Unilateral Enucleation for Retinoblastoma in Pediatric Patients","volume":"31","author":"Hauck","year":"2015","journal-title":"Ophthalmic Plast. Reconstr. Surg."},{"key":"B33","doi-asserted-by":"publisher","first-page":"81","DOI":"10.1097\/00002341-199803000-00002","article-title":"Unilateral Dermis-Fat Graft Implantation in the Pediatric Orbit","volume":"14","author":"Heher","year":"1998","journal-title":"Ophthalmic Plast. Reconstr. Surg."},{"key":"B34","doi-asserted-by":"publisher","first-page":"123","DOI":"10.1097\/01.iop.0000152495.25263.61","article-title":"Exposure of Orbital Implants Wrapped with Polyester-Urethane after Enucleation for Advanced Retinoblastoma","volume":"21","author":"Heimann","year":"2005","journal-title":"Ophthalmic Plast. Reconstr. Surg."},{"key":"B35","doi-asserted-by":"publisher","first-page":"87","DOI":"10.1097\/00002341-198703020-00006","article-title":"Complications Following Enucleation and Implantation of Multiple Glass Spheres in the Orbit","volume":"3","author":"Helms","year":"1987","journal-title":"Ophthalmic Plast. Reconstr. Surg."},{"key":"B36","first-page":"6","article-title":"A Pictorial Anatomy of the Human Eye\/anophthalmic Socket: a Review for Ocularists","volume":"4","author":"Hughes","year":"2007","journal-title":"eye"},{"key":"B37","doi-asserted-by":"publisher","first-page":"84","DOI":"10.1016\/j.bjps.2015.09.011","article-title":"Use of the Anterolateral Thigh Flap for Reconstruction of the Pediatric Anophthalmic Orbit","volume":"69","author":"Hynes","year":"2016","journal-title":"J. Plast. Reconstr. Aesthet. Surg."},{"key":"B38","doi-asserted-by":"publisher","first-page":"83","DOI":"10.1007\/s00417-015-3144-6","article-title":"A Biomimetic Collagen\/heparin Multi-Layered Porous Hydroxyapatite Orbital Implant for In Vivo Vascularization Studies on the Chicken Chorioallantoic Membrane","volume":"254","author":"Jin","year":"2016","journal-title":"Graefes Arch. Clin. Exp. Ophthalmol."},{"key":"B39","doi-asserted-by":"publisher","first-page":"7","DOI":"10.1016\/s0008-4182(02)80092-8","article-title":"Hydroxyapatite and Calcium Phophate Coatings on Aluminium Oxide Orbital Implants","volume":"37","author":"Jordan","year":"2002","journal-title":"Can. J. Ophthalmol."},{"key":"B40","doi-asserted-by":"publisher","first-page":"356","DOI":"10.1097\/00002341-200009000-00009","article-title":"The Molteno M-Sphere","volume":"16","author":"Jordan","year":"2000","journal-title":"Ophthalmic Plast. Reconstr. Surg."},{"key":"B41","doi-asserted-by":"crossref","first-page":"195","DOI":"10.1007\/978-3-540-85542-2_14","article-title":"Controversies in Enucleation Technique and Implant Selection: Whether to Wrap, Attach Muscles, and Peg","volume-title":"Oculoplastics and Orbit: Aesthetic and Functional Oculofacial Plastic Problem-Solving in the 21st Century","author":"Jordan","year":"2010"},{"key":"B43","doi-asserted-by":"publisher","first-page":"347","DOI":"10.1097\/00002341-200009000-00008","article-title":"The Bioceramic Orbital Implant: a New Generation of Porous Implants","volume":"16","author":"Jordan","year":"2000","journal-title":"Ophthalmic Plast. Reconstr. Surg."},{"key":"B44","doi-asserted-by":"publisher","first-page":"465","DOI":"10.1097\/icu.0000000000000297","article-title":"Current Indications for Pegging in the Anophthalmic Socket","volume":"27","author":"Jordan","year":"2016","journal-title":"Curr. Opin. Ophthalmol."},{"key":"B45","article-title":"Reconstruction of Empty SocG.L. Zahid Kamal, Abdul Hye, Out Come of Sahaf Enucleation Implants in 60 Patients, pjo (2008)","author":"Kamal","year":"2010","journal-title":"Kets With Sahaf\u2019s Orbital Implant"},{"key":"B46","doi-asserted-by":"publisher","first-page":"1688","DOI":"10.1016\/s0161-6420(94)31114-6","article-title":"High-density Porous Polyethylene (Medpor) as a Successful Anophthalmic Socket Implant","volume":"101","author":"Karesh","year":"1994","journal-title":"Ophthalmology"},{"key":"B42","first-page":"46","article-title":"Hydroxyapatite Orbital Implant Vascularization Assessed by Magnetic Resonance Imaging","volume-title":"Ophthalmic Plast Reconstr Surg","author":"Klapper","year":"2003"},{"key":"B47","doi-asserted-by":"publisher","first-page":"449","DOI":"10.1007\/s00347-003-0836-9","article-title":"Deckung von Orbitaimplantaten mit muskelgestielter autologer Sklera","volume":"100","author":"Klett","year":"2003","journal-title":"Ophthalmologe"},{"key":"B48","doi-asserted-by":"publisher","first-page":"445","DOI":"10.1007\/s00347-003-0837-8","article-title":"Wie l\u00e4sst sich die Prothesenmotilit\u00e4t verbessern?","volume":"100","author":"Klett","year":"2003","journal-title":"Ophthalmologe"},{"key":"B49","doi-asserted-by":"publisher","first-page":"16","DOI":"10.21037\/aes-20-97","article-title":"Bioengineered Dermal Substitutes for Periocular Defects","volume":"6","author":"Kopeck\u00fd","year":"2021","journal-title":"Ann. Eye Sci."},{"key":"B50","doi-asserted-by":"publisher","first-page":"569","DOI":"10.1038\/eye.1994.139","article-title":"The 'baseball' Orbital Implant: A Prospective Study","volume":"8","author":"Leatherbarrow","year":"1994","journal-title":"Eye"},{"key":"B51","doi-asserted-by":"publisher","first-page":"940","DOI":"10.1016\/s0161-6420(00)00016-6","article-title":"Exposure of Primary Orbital Implants in Postenucleation Retinoblastoma patients11The Authors Have No Financial or Proprietary Interest in Any of the Materials Used in This Study","volume":"107","author":"Lee","year":"2000","journal-title":"Ophthalmology"},{"key":"B52","doi-asserted-by":"publisher","first-page":"21","DOI":"10.1097\/iop.0b013e3181de01a7","article-title":"The Porous Polyethylene\/bioglass Spherical Orbital Implant: a Retrospective Study of 170 Cases","volume":"27","author":"Ma","year":"2011","journal-title":"Ophthalmic Plast. Reconstr. Surg."},{"key":"B53","doi-asserted-by":"publisher","first-page":"403","DOI":"10.1080\/01676830802345042","article-title":"The Quasi-Integrated Porous Polyethylene Implant in Pediatric Patients Enucleated for Retinoblastoma","volume":"27","author":"Marx","year":"2008","journal-title":"Orbit"},{"key":"B54","doi-asserted-by":"publisher","first-page":"104","DOI":"10.3109\/01676830.2013.851706","article-title":"Porous Orbital Implant Exposure: The Influence of Surgical Technique","volume":"33","author":"McElnea","year":"2014","journal-title":"Orbit"},{"key":"B55","volume-title":"Silicones and Their Uses","author":"McGregor","year":"1954"},{"key":"B56","doi-asserted-by":"publisher","first-page":"181","DOI":"10.1080\/01676830.2016.1176206","article-title":"Periumbilical Fat Auto-Graft Associated to a Porous Orbital Implant for Socket Reconstruction after Enucleation","volume":"35","author":"Medel","year":"2016","journal-title":"Orbit"},{"key":"B57","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1016\/j.actbio.2014.11.004","article-title":"Bioactive Glasses beyond Bone and Teeth: Emerging Applications in Contact with Soft Tissues","volume":"13","author":"Miguez-Pacheco","year":"2015","journal-title":"Acta Biomater."},{"key":"B58","doi-asserted-by":"publisher","first-page":"129","DOI":"10.1111\/j.1442-9071.1991.tb00640.x","article-title":"Bone Implants after Enucleation","volume":"19","author":"Molteno","year":"1991","journal-title":"Aust. New Zealand J. Ophthalmol."},{"key":"B59","doi-asserted-by":"publisher","first-page":"277","DOI":"10.1016\/s0039-6257(99)00112-5","article-title":"Enucleation","volume":"44","author":"Moshfeghi","year":"2000","journal-title":"Surv. Ophthalmol."},{"key":"B60","doi-asserted-by":"publisher","first-page":"e0121292","DOI":"10.1371\/journal.pone.0121292","article-title":"Worldwide Enucleation Techniques and Materials for Treatment of Retinoblastoma: An International Survey","volume":"10","author":"Mourits","year":"2015","journal-title":"PLoS One"},{"key":"B61","doi-asserted-by":"publisher","first-page":"165","DOI":"10.1111\/aos.12915","article-title":"Orbital Implants in Retinoblastoma Patients: 23 Years of Experience and a Review of the Literature","volume":"94","author":"Mourits","year":"2016","journal-title":"Acta Ophthalmol."},{"key":"B62","first-page":"200","article-title":"Evisceration of the Giobe with Artificial Vitreous","volume":"5","author":"Mules","year":"1885","journal-title":"Ophthalmol. Soc. UK"},{"key":"B63","doi-asserted-by":"publisher","first-page":"1259","DOI":"10.1001\/archopht.118.9.1259","article-title":"Design of a Magnetically Integrated Microporous Implant","volume":"118","author":"Murray","year":"2000","journal-title":"Arch. Ophthalmol."},{"key":"B64","doi-asserted-by":"publisher","first-page":"315","DOI":"10.1177\/003591577006300348","article-title":"The Long-Term Effects of Ocular Implants [Abridged]","volume":"63","author":"Myska","year":"1970","journal-title":"Proc. R. Soc. Med."},{"key":"B65","doi-asserted-by":"publisher","first-page":"463","DOI":"10.1097\/iop.0b013e318158ec8e","article-title":"Comparison of Vascularization of Medpor and Medpor-Plus Orbital Implants: a Prospective, Randomized Study","volume":"23","author":"Naik","year":"2007","journal-title":"Ophthalmic Plast. Reconstr. Surg."},{"key":"B66","doi-asserted-by":"publisher","first-page":"33","DOI":"10.3109\/01676830.2013.844172","article-title":"Dermis Fat Grafts as Primary and Secondary Orbital Implants","volume":"33","author":"Nentwich","year":"2014","journal-title":"Orbit"},{"key":"B67","doi-asserted-by":"publisher","first-page":"494","DOI":"10.1016\/s0161-6420(84)34262-2","article-title":"Enucleation with Implantation of a Proplast Sphere","volume":"91","author":"Neuhaus","year":"1984","journal-title":"Ophthalmology"},{"key":"B68","doi-asserted-by":"publisher","first-page":"437","DOI":"10.1007\/s00347-003-0832-0","article-title":"Erfahrungen mit Orbitaimplantaten, insbesondere mit por\u00f6sen Hydroxylapatitmaterialien","volume":"100","author":"Norda","year":"2003","journal-title":"Ophthalmologe"},{"key":"B69","doi-asserted-by":"publisher","first-page":"90","DOI":"10.1097\/00002341-199306000-00003","article-title":"Extrusion Rate of Silicone Spherical Anophthalmic Socket Implants","volume":"9","author":"Nunery","year":"1993","journal-title":"Ophthalmic Plast. Reconstr. Surg."},{"key":"B70","doi-asserted-by":"publisher","first-page":"96","DOI":"10.1097\/00002341-199306000-00004","article-title":"Exposure Rate of Hydroxyapatite Spheres in the Anophthalmic Socket: Histopathologic Correlation and Comparison with Silicone Sphere Implants","volume":"9","author":"Nunery","year":"1993","journal-title":"Ophthalmic Plast. Reconstr. Surg."},{"key":"B71","doi-asserted-by":"publisher","first-page":"617","DOI":"10.1007\/978-0-387-21630-0_32","article-title":"Pediatric Enucleation, Evisceration, and Exenteration Techniques","author":"Piest","year":"2002","journal-title":"Pediatr. Oculoplastic Surg."},{"key":"B72","doi-asserted-by":"publisher","first-page":"707","DOI":"10.2147\/OPTH.S31126","article-title":"A Survey of Prosthetic Eye Wearers to Investigate Mucoid Discharge","volume":"6","author":"Pine","year":"2012","journal-title":"Clin. Ophthalmol."},{"key":"B73","doi-asserted-by":"publisher","first-page":"47","DOI":"10.1111\/j.1442-9071.2010.02381.x","article-title":"Concerns of Anophthalmic Patients Wearing Artificial Eyes","volume":"39","author":"Pine","year":"2011","journal-title":"Clin. Exp. Ophthalmol."},{"key":"B74","doi-asserted-by":"publisher","first-page":"147","DOI":"10.4103\/0301-4738.39121","article-title":"Management of an Irradiated Anophthalmic Socket Following Dermis-Fat Graft Rejection: a Case Report","volume":"56","author":"Raizada","year":"2008","journal-title":"Indian J. Ophthalmol."},{"key":"B75","doi-asserted-by":"publisher","first-page":"575","DOI":"10.1136\/bjo.40.9.575","article-title":"Magnetic Orbital Implant","volume":"40","author":"Roper-Hall","year":"1956","journal-title":"Br. J. Ophthalmol."},{"key":"B76","doi-asserted-by":"publisher","first-page":"173","DOI":"10.1001\/archopht.1992.01080140023013","article-title":"Foreign-Body Giant-Cell Reaction to the Hydroxyapatite Orbital Implant","volume":"110","author":"Rosner","year":"1992","journal-title":"Arch. Ophthalmol."},{"key":"B77","doi-asserted-by":"publisher","first-page":"244","DOI":"10.1016\/j.survophthal.2007.02.007","article-title":"Perspective on Orbital Enucleation Implants","volume":"52","author":"Sami","year":"2007","journal-title":"Surv. Ophthalmol."},{"key":"B78","doi-asserted-by":"publisher","first-page":"1349","DOI":"10.1038\/s41433-019-0398-y","article-title":"Living with an Artificial Eye-The Emotional and Psychosocial Impact","volume":"33","author":"Saxby","year":"2019","journal-title":"Eye"},{"key":"B79","doi-asserted-by":"publisher","first-page":"63","DOI":"10.1159\/000291166","article-title":"VII. Zur L\u00f6sung des Problems der Kugeleinheilung","volume":"16","author":"Schmidt","year":"1906","journal-title":"Ophthalmologica"},{"key":"B80","doi-asserted-by":"publisher","first-page":"321","DOI":"10.1159\/000291794","article-title":"II. Zur L\u00f6sung des Problems der Kugeleinheilung. Nachtrag 1909","volume":"23","author":"Schmidt","year":"1910","journal-title":"Ophthalmologica"},{"key":"B81","doi-asserted-by":"publisher","first-page":"271","DOI":"10.4103\/0974-9233.134694","article-title":"Fabrication of a Custom Ocular Prosthesis","volume":"21","author":"Sethi","year":"2014","journal-title":"Middle East. Afr. J. Ophthalmol."},{"key":"B82","doi-asserted-by":"publisher","first-page":"108","DOI":"10.1097\/iop.0000000000000207","article-title":"Hydroxyapatite Orbital Implant in Children Following Enucleation","volume":"31","author":"Shah","year":"2015","journal-title":"Ophthalmic Plast. Reconstr. Surg."},{"key":"B83","doi-asserted-by":"publisher","first-page":"1692","DOI":"10.1136\/bjophthalmol-2014-306585","article-title":"Chronic Anophthalmic Socket Pain Treated by Implant Removal and Dermis Fat Graft","volume":"99","author":"Shams","year":"2015","journal-title":"Br. J. Ophthalmol."},{"key":"B84","first-page":"24","article-title":"Out Come of Sahaf Enucleation Implants in 60 Patients","author":"Siddiqi","year":"2008","journal-title":"Pakistan J. Ophthalmol."},{"key":"B85","doi-asserted-by":"publisher","first-page":"163","DOI":"10.1097\/00002341-198601060-00009","article-title":"Evolution and Current Concepts in the Surgical Treatment of the Anophthalmic Orbit","volume":"2","author":"Soll","year":"1986","journal-title":"Ophthalmic Plast. Reconstr. Surg."},{"key":"B86","doi-asserted-by":"publisher","first-page":"171","DOI":"10.1016\/0002-9394(69)93147-x","article-title":"The Iowa Enucleation Implant","volume":"67","author":"Spivey","year":"1969","journal-title":"Am. J. Ophthalmol."},{"key":"B87","doi-asserted-by":"publisher","first-page":"1287","DOI":"10.1136\/bjo.86.11.1287","article-title":"Long Term Follow up of Bone Derived Hydroxyapatite Orbital Implants","volume":"86","author":"Suter","year":"2002","journal-title":"Br. J. Ophthalmol."},{"key":"B88","doi-asserted-by":"publisher","first-page":"e137","DOI":"10.1097\/iop.0000000000000328","article-title":"Foreign Body Granuloma Following Orbital Reconstruction with Porous Polyethylene","volume":"32","author":"Timoney","year":"2016","journal-title":"Ophthalmic Plast. Reconstr. Surg."},{"key":"B89","doi-asserted-by":"publisher","first-page":"58","DOI":"10.1001\/archopht.1954.00920050060006","article-title":"FIVE-YEAR SURVEY ON USE OF A MAGNETIC IMPLANT FOR IMPROVING COSMETIC RESULT OF ENUCLEATION","volume":"52","author":"Troutman","year":"1954","journal-title":"Arch. Ophthalmol."},{"key":"B90","doi-asserted-by":"publisher","first-page":"645","DOI":"10.1111\/j.1442-9071.2006.01308.x","article-title":"Transplantation of Ocular Tissue from a Donor with Sporadic Creutzfeldt?Jakob Disease","volume":"34","author":"Tullo","year":"2006","journal-title":"Clin. Exp. Ophthalmol."},{"key":"B91","doi-asserted-by":"publisher","first-page":"438","DOI":"10.1136\/bjo.69.6.438","article-title":"Baseball Orbital Implants: a Review of 39 Patients","volume":"69","author":"Tyers","year":"1985","journal-title":"Br. J. Ophthalmol."},{"key":"B92","doi-asserted-by":"publisher","first-page":"616","DOI":"10.1136\/bjo.2006.103937","article-title":"UK National Survey of Enucleation, Evisceration and Orbital Implant Trends","volume":"91","author":"Viswanathan","year":"2007","journal-title":"Br. J. Ophthalmol."},{"key":"B93","doi-asserted-by":"publisher","first-page":"723","DOI":"10.1007\/s10792-013-9859-7","article-title":"Survey on the Management of Orbital and Intraocular Tumors Among Oculofacial Surgeons in the Asia-Pacific Region","volume":"34","author":"Wang","year":"2014","journal-title":"Int. Ophthalmol."},{"key":"B94","doi-asserted-by":"publisher","first-page":"821","DOI":"10.1007\/s00417-014-2600-z","article-title":"The Reconstruction of a Contracted Eye Socket Using a post-auricular Full-Thickness Skin Graft","volume":"252","author":"Wei","year":"2014","journal-title":"Graefes Arch. Clin. Exp. Ophthalmol."},{"key":"B95","doi-asserted-by":"publisher","first-page":"292","DOI":"10.1016\/0266-4356(93)90062-2","article-title":"Post-operative Infection of Proplast Facial Implants","volume":"31","author":"Whear","year":"1993","journal-title":"Br. J. Oral Maxillofacial Surg."},{"key":"B96","doi-asserted-by":"publisher","first-page":"2941","DOI":"10.1016\/j.biomaterials.2008.04.023","article-title":"On the Mechanisms of Biocompatibility","volume":"29","author":"Williams","year":"2008","journal-title":"Biomaterials"},{"key":"B97","doi-asserted-by":"publisher","first-page":"805","DOI":"10.1002\/jbm.820150605","article-title":"Toxicology and Biocompatibility of Bioglasses","volume":"15","author":"Wilson","year":"1981","journal-title":"J. Biomed. Mater. Res."},{"key":"B98","first-page":"440","article-title":"Clinical Study of Bioactive Glass Ceramics as Orbital Implants","volume":"22","author":"Xu","year":"1997","journal-title":"Hunan Yi Ke Da Xue Xue Bao"},{"key":"B99","doi-asserted-by":"publisher","first-page":"961","DOI":"10.1007\/s10529-014-1465-x","article-title":"Copper-containing Mesoporous Bioactive Glass Coatings on Orbital Implants for Improving Drug Delivery Capacity and Antibacterial Activity","volume":"36","author":"Ye","year":"2014","journal-title":"Biotechnol. Lett."},{"key":"B100","first-page":"563","article-title":"Hydroxyapatite Coated Porous Alumina as a New Orbital Implant","volume-title":"Key Engineering Materials","author":"You","year":"2003"},{"key":"B101","doi-asserted-by":"publisher","first-page":"705","DOI":"10.1136\/bjo.38.12.705","article-title":"Magnetic Intra-ocular Implant : New Surgery of the Implant the Magnetic Artificial Eye","volume":"38","author":"Young","year":"1954","journal-title":"Br. J. Ophthalmol."},{"key":"B102","doi-asserted-by":"publisher","first-page":"711","DOI":"10.1002\/jmri.1880010617","article-title":"Extrusion of Eye Socket Magnetic Implant after MR Imaging: Potential hazard to Patient with Eye Prosthesis","volume":"1","author":"Yuh","year":"1991","journal-title":"J. Magn. Reson. Imaging"}],"container-title":["Frontiers in Bioengineering and Biotechnology"],"original-title":[],"link":[{"URL":"https:\/\/www.frontiersin.org\/articles\/10.3389\/fbioe.2021.800998\/full","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2022,2,17]],"date-time":"2022-02-17T09:24:57Z","timestamp":1645089897000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.frontiersin.org\/articles\/10.3389\/fbioe.2021.800998\/full"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2022,2,17]]},"references-count":102,"alternative-id":["10.3389\/fbioe.2021.800998"],"URL":"https:\/\/doi.org\/10.3389\/fbioe.2021.800998","relation":{},"ISSN":["2296-4185"],"issn-type":[{"value":"2296-4185","type":"electronic"}],"subject":[],"published":{"date-parts":[[2022,2,17]]},"article-number":"800998"}}