{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,23]],"date-time":"2026-10-23T20:30:29Z","timestamp":1792787429500,"version":"4.5.0"},"reference-count":42,"publisher":"Frontiers Media SA","license":[{"start":{"date-parts":[[2022,10,10]],"date-time":"2022-10-10T00:00:00Z","timestamp":1665360000000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"content-domain":{"domain":["frontiersin.org"],"crossmark-restriction":true},"short-container-title":["Front. Bioeng. Biotechnol."],"abstract":"<jats:p>Inferior vena cava (IVC) filters are used to prevent pulmonary embolism in patients with deep vein thrombosis for whom anticoagulation is unresponsive. The head is a necessary structure for an Inferior vena cava filter (IVCF) in clinic use. At present, there are various head configurations for IVCFs. However, the effect of head pattern on the hemodynamics of IVCF is still a matter of unclear. In this study, computational fluid dynamics is used to simulate non-Newtonian blood flows around four IVCFs with different heads inside an IVC model, in which the Denali filter with a solid and hooked head is employed as a prototype, and three virtual variants are reconstructed either with a no-hook head or with a through-hole head for comparison. The simulation results show that the through-hole head can effectively avoid the recirculation region and weaken the blood flow stasis closely downstream the IVCF head. The shape change of the filter head has no significant effect on the blood flow acceleration inside the IVCF cone as well as little influence on the wall shear stress (WSS) distribution on the filter wire surface and IVC wall. The structure pattern of filter head greatly affects the flow resistance of its own. However, the flow drag of filter head only occupies a small proportion of the total resistance of IVCF. Therefore, to reduce the flow resistance of an IVCF should optimize its whole structure.<\/jats:p>","DOI":"10.3389\/fbioe.2022.1034120","type":"journal-article","created":{"date-parts":[[2022,10,10]],"date-time":"2022-10-10T06:18:30Z","timestamp":1665382710000},"update-policy":"https:\/\/doi.org\/10.3389\/crossmark-policy","source":"Crossref","is-referenced-by-count":9,"title":["Evaluation of hemodynamic effects of different inferior vena cava filter heads using computational fluid dynamics"],"prefix":"10.3389","volume":"10","author":[{"given":"Mingrui","family":"Li","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Jingying","family":"Wang","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Wen","family":"Huang","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Yue","family":"Zhou","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Xue","family":"Song","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"1965","published-online":{"date-parts":[[2022,10,10]]},"reference":[{"key":"B1","doi-asserted-by":"publisher","first-page":"367","DOI":"10.1016\/j.carj.2019.06.003","article-title":"Inferior vena cava filter evaluation and management for the diagnostic radiologist: A comprehensive review including inferior vena cava filter-related complications and preserve trial filters","volume":"70","author":"Ahmed","year":"2019","journal-title":"Can. Assoc. Radiol. J."},{"key":"B2","doi-asserted-by":"publisher","first-page":"450","DOI":"10.1177\/0268355520975582","article-title":"Inferior vena cava filters utilization in patients with venous thromboembolism: Analysis of a database of a tertiary hospital","volume":"36","author":"Arslanbekov","year":"2021","journal-title":"Phlebology."},{"key":"B3","doi-asserted-by":"publisher","first-page":"H1786","DOI":"10.1152\/ajpheart.00461.2014","article-title":"A longitudinal comparison of hemodynamics and intraluminal thrombus deposition in abdominal aortic aneurysms","volume":"307","author":"Arzani","year":"2014","journal-title":"Am. J. Physiology-Heart Circulatory Physiology"},{"key":"B4","doi-asserted-by":"publisher","first-page":"3568","DOI":"10.1007\/s10439-016-1663-x","article-title":"The importance of hemorheology and patient anatomy on the hemodynamics in the inferior vena cava","volume":"44","author":"Aycock","year":"2016","journal-title":"Ann. Biomed. Eng."},{"key":"B5","doi-asserted-by":"publisher","DOI":"10.1115\/1.4027612","article-title":"A computational method for predicting inferior vena cava filter performance on a patient-specific basis","volume":"136","author":"Aycock","year":"2014","journal-title":"J. Biomech. Eng."},{"key":"B6","doi-asserted-by":"publisher","first-page":"40724","DOI":"10.1038\/srep40724","article-title":"Improvement of hemodynamic performance using novel helical flow vena cava filter design","volume":"7","author":"Chen","year":"2017","journal-title":"Sci. Rep."},{"key":"B7","doi-asserted-by":"publisher","first-page":"H1161","DOI":"10.1152\/ajpheart.00641.2002","article-title":"Inferior vena caval hemodynamics quantified in vivo at rest and during cycling exercise using magnetic resonance imaging","volume":"284","author":"Cheng","year":"2003","journal-title":"Am. J. Physiology-Heart Circulatory Physiology"},{"key":"B8","doi-asserted-by":"publisher","first-page":"241","DOI":"10.3233\/BIR-1991-283-415","article-title":"Effects of the non-Newtonian viscosity of blood on flows in a diseased arterial vessel. Part 1: Steady flows","volume":"28","author":"Cho","year":"1991","journal-title":"Biorheology"},{"key":"B9","doi-asserted-by":"publisher","first-page":"654","DOI":"10.1007\/s13239-018-00392-0","article-title":"Steady flow in a patient-averaged inferior vena cava\u2014part II: Computational fluid dynamics verification and validation","volume":"9","author":"Craven","year":"2018","journal-title":"Cardiovasc. Eng. Technol."},{"key":"B10","doi-asserted-by":"publisher","first-page":"093","DOI":"10.1055\/s-0036-1583208","article-title":"Evidence-based evaluation of inferior vena cava filter complications based on filter type","volume":"33","author":"Deso","year":"2016","journal-title":"Semin. Interv. Radiol."},{"key":"B11","doi-asserted-by":"publisher","first-page":"3","DOI":"10.1111\/jth.13564","article-title":"Inferior vena cava filters","volume":"15","author":"Duffett","year":"2017","journal-title":"J. Thromb. Haemost."},{"key":"B12","doi-asserted-by":"publisher","first-page":"277","DOI":"10.1177\/0885066619890324","article-title":"Outcomes and prognosis factors in patients with vena cava filters in a quaternary medical center: A 5-year retrospective analysis","volume":"36","author":"Elias","year":"2021","journal-title":"J. Intensive Care Med."},{"key":"B13","doi-asserted-by":"publisher","first-page":"379","DOI":"10.1055\/s-0035-1564812","article-title":"Retrievable filter update: The Denali vena cava filter","volume":"32","author":"Hahn","year":"2015","journal-title":"Semin. Interv. Radiol."},{"key":"B14","doi-asserted-by":"publisher","first-page":"464","DOI":"10.1038\/nrcardio.2015.83","article-title":"Epidemiology of venous thromboembolism","volume":"12","author":"Heit","year":"2000","journal-title":"Nat. Rev. Cardiol."},{"key":"B15","doi-asserted-by":"publisher","first-page":"030006052110065","DOI":"10.1177\/03000605211006591","article-title":"Retrievable inferior vena cava filter to prevent pulmonary embolism in patients with fractures and deep venous thrombosis of lower extremities: A single-center experience","volume":"49","author":"Huang","year":"2021","journal-title":"J. Int. Med. Res."},{"key":"B16","doi-asserted-by":"publisher","first-page":"344","DOI":"10.1016\/S0006-3495(93)81079-8","article-title":"Aggregation and disaggregation kinetics of human blood platelets: Part II. shear-Induced platelet aggregation","volume":"65","author":"Huang","year":"1993","journal-title":"Biophys. J."},{"key":"B17","doi-asserted-by":"publisher","first-page":"129","DOI":"10.1016\/j.iccl.2017.08.004","article-title":"Inferior vena cava filters: Current and future concepts","volume":"7","author":"Kaufman","year":"2018","journal-title":"Interv. Cardiol. Clin."},{"key":"B18","doi-asserted-by":"publisher","first-page":"542","DOI":"10.1016\/j.injury.2012.01.020","article-title":"The use of prophylactic inferior vena cava filters in trauma patients: A systematic review","volume":"43","author":"Kidane","year":"2012","journal-title":"Injury"},{"key":"B19","doi-asserted-by":"publisher","first-page":"543","DOI":"10.1093\/eurheartj\/ehz405","article-title":"2019 ESC guidelines for the diagnosis and management of acute pulmonary embolism developed in collaboration with the european respiratory society (ERS)","volume":"41","author":"Konstantinides","year":"2020","journal-title":"Eur. Heart J."},{"key":"B20","doi-asserted-by":"publisher","first-page":"485","DOI":"10.1097\/01.RVI.0000124941.58200.85","article-title":"Hemodynamic effects of clot entrapment in the TrapEase inferior vena cava filter","volume":"15","author":"Leask","year":"2004","journal-title":"J. Vasc. Interv. Radiol."},{"key":"B21","doi-asserted-by":"publisher","first-page":"449","DOI":"10.1024\/0301-1526\/a000887","article-title":"Inferior vena cava filter\u2013comprehensive overview of current indications, techniques, complications and retrieval rates","volume":"49","author":"Li","year":"2020","journal-title":"Vasa"},{"key":"B22","doi-asserted-by":"publisher","first-page":"3848","DOI":"10.1109\/ACCESS.2018.2888490","article-title":"Quantitative analysis of blood flow in cerebral venous sinus with stenosis by patient-specific CFD modeling","volume":"7","author":"Liu","year":"2018","journal-title":"IEEE Access"},{"key":"B23","doi-asserted-by":"publisher","first-page":"e2990","DOI":"10.1002\/cnm.2990","article-title":"A comparative CFD study of four inferior vena cava filters","volume":"34","author":"L\u00f3pez","year":"2018","journal-title":"Int. J. Numer. Method. Biomed. Eng."},{"key":"B24","doi-asserted-by":"publisher","first-page":"455","DOI":"10.1159\/000083845","article-title":"Virchow\u2019s triad revisited: Abnormal flow","volume":"33","author":"Lowe","year":"2003","journal-title":"Pathophysiol. Haemost. Thromb."},{"key":"B25","doi-asserted-by":"publisher","first-page":"1011","DOI":"10.3233\/BIR-1989-26605","article-title":"Pulsatile non-Newtonian blood flow simulation through a bifurcation with an aneurysm","volume":"26","author":"Perktold","year":"1989","journal-title":"Biorheology"},{"key":"B26","doi-asserted-by":"publisher","first-page":"835","DOI":"10.1016\/j.jvir.2010.12.024","article-title":"Three-dimensional analysis of flow disturbances caused by clots in inferior vena cava filters","volume":"22","author":"Rahbar","year":"2011","journal-title":"J. Vasc. Interv. Radiol."},{"key":"B27","doi-asserted-by":"publisher","first-page":"104","DOI":"10.1016\/j.surge.2016.07.003","article-title":"Retrievable IVC filters\u2013Friend or foe","volume":"15","author":"Ryan","year":"2017","journal-title":"Surg."},{"key":"B28","doi-asserted-by":"publisher","DOI":"10.36909\/jer.9887","article-title":"Investigation of helical strut attached vena cava filter hemodynamic performanc","volume":"9","author":"Selimli","year":"2021","journal-title":"J. Eng. Res. Ponta. Grossa."},{"key":"B29","doi-asserted-by":"publisher","first-page":"114","DOI":"10.3389\/fbioe.2020.00114","article-title":"Impact of aortoseptal angle abnormalities and discrete subaortic stenosis on left-ventricular outflow tract hemodynamics: Preliminary computational assessment","volume":"8","author":"Shar","year":"2020","journal-title":"Front. Bioeng. Biotechnol."},{"key":"B30","doi-asserted-by":"publisher","first-page":"799","DOI":"10.1016\/j.jvir.2009.02.015","article-title":"Computational modeling of blood flow in the trapease inferior vena cava filter","volume":"20","author":"Singer","year":"2009","journal-title":"J. Vasc. Interv. Radiol."},{"key":"B31","doi-asserted-by":"publisher","first-page":"360","DOI":"10.1115\/1.2187034","article-title":"Numerical analysis of the hemodynamics and embolus capture of a greenfield vena cava filter","volume":"128","author":"Swaminathan","year":"2006","journal-title":"J. biomechanical Eng."},{"key":"B32","doi-asserted-by":"publisher","first-page":"336","DOI":"10.1063\/1.4902290","article-title":"Carreau model for oscillatory blood flow in a tube","volume":"1629","author":"Tabakova","year":"2014","journal-title":"AIP Conf. Proc."},{"key":"B33","doi-asserted-by":"publisher","first-page":"44","DOI":"10.1016\/j.medengphy.2018.02.003","article-title":"An experimental and computational study of the inferior vena cava hemodynamics under respiratory-induced collapse of the infrarenal IVC","volume":"54","author":"Tedaldi","year":"2018","journal-title":"Med. Eng. Phys."},{"key":"B34","doi-asserted-by":"publisher","first-page":"1098","DOI":"10.1016\/j.compbiomed.2013.05.023","article-title":"Simulation of a pulsatile non-Newtonian flow past a stenosed 2D artery with atherosclerosis","volume":"43","author":"Tian","year":"2013","journal-title":"Comput. Biol. Med."},{"key":"B35","doi-asserted-by":"publisher","first-page":"S25","DOI":"10.1016\/S0049-3848(98)00157-1","article-title":"Mechanical factors affecting hemostasis and thrombosis","volume":"92","author":"Turitto","year":"1998","journal-title":"Thromb. Res."},{"key":"B36","doi-asserted-by":"publisher","first-page":"143","DOI":"10.3390\/bioengineering8100143","article-title":"Hemodynamic investigation of the effectiveness of a two overlapping flow diverter configuration for cerebral aneurysm treatment","volume":"8","author":"Uchiyama","year":"2021","journal-title":"Bioengineering"},{"key":"B37","doi-asserted-by":"publisher","first-page":"556110","DOI":"10.3389\/fbioe.2020.556110","article-title":"Hemodynamic analysis of VenaTech convertible vena cava filter using computational fluid dynamics","volume":"8","author":"Wang","year":"2020","journal-title":"Front. Bioeng. Biotechnol."},{"key":"B38","doi-asserted-by":"publisher","first-page":"349","DOI":"10.3389\/fbioe.2019.00349","article-title":"Carotid bifurcation with tandem stenosis\u2014a patient-specific case study combined in vivo imaging, in vitro histology and in silico simulation","volume":"7","author":"Wang","year":"2019","journal-title":"Front. Bioeng. Biotechnol."},{"key":"B39","doi-asserted-by":"publisher","first-page":"367","DOI":"10.1016\/j.jvir.2009.11.013","article-title":"Toward an optimal position for inferior vena cava filters: Computational modeling of the impact of renal vein inflow with Celect and TrapEase filters","volume":"21","author":"Wang","year":"2010","journal-title":"J. Vasc. Interv. Radiol."},{"key":"B40","doi-asserted-by":"publisher","first-page":"275","DOI":"10.1213\/ANE.0b013e31823a088c","article-title":"Procoagulant activity in hemostasis and thrombosis: Virchow\u2019s triad revisited","volume":"114","author":"Wolberg","year":"2012","journal-title":"Anesth. Analg."},{"key":"B41","doi-asserted-by":"publisher","first-page":"79","DOI":"10.1016\/j.jjcc.2021.08.026","article-title":"Venous thromboembolism: Recent advancement and future perspective","volume":"79","author":"Yamashita","year":"2022","journal-title":"J. Cardiol."},{"key":"B42","doi-asserted-by":"publisher","first-page":"326","DOI":"10.3390\/bioengineering9070326","article-title":"Effects of pulsatile flow rate and shunt ratio in bifurcated distal arteries on hemodynamic characteristics involved in two patient-specific internal carotid artery sidewall aneurysms: A numerical study","volume":"9","author":"Yi","year":"2022","journal-title":"Bioengineering"}],"container-title":["Frontiers in Bioengineering and Biotechnology"],"original-title":[],"link":[{"URL":"https:\/\/www.frontiersin.org\/articles\/10.3389\/fbioe.2022.1034120\/full","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2022,10,10]],"date-time":"2022-10-10T06:18:33Z","timestamp":1665382713000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.frontiersin.org\/articles\/10.3389\/fbioe.2022.1034120\/full"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2022,10,10]]},"references-count":42,"alternative-id":["10.3389\/fbioe.2022.1034120"],"URL":"https:\/\/doi.org\/10.3389\/fbioe.2022.1034120","relation":{},"ISSN":["2296-4185"],"issn-type":[{"value":"2296-4185","type":"electronic"}],"subject":[],"published":{"date-parts":[[2022,10,10]]},"article-number":"1034120"}}