{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,9,25]],"date-time":"2026-09-25T14:24:42Z","timestamp":1790346282377,"version":"4.1.0"},"reference-count":52,"publisher":"Frontiers Media SA","license":[{"start":{"date-parts":[[2022,3,8]],"date-time":"2022-03-08T00:00:00Z","timestamp":1646697600000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"funder":[{"DOI":"10.13039\/501100001809","name":"National Natural Science Foundation of China","doi-asserted-by":"publisher","id":[{"id":"10.13039\/501100001809","id-type":"DOI","asserted-by":"publisher"}]}],"content-domain":{"domain":["frontiersin.org"],"crossmark-restriction":true},"short-container-title":["Front. Bioeng. Biotechnol."],"abstract":"<jats:p>There is no consensus about the optimal internal fixation selection for treatment of posterolateral tibial plateau fracture. This study described a novel plate through an anterolateral approach for posterolateral tibial plateau fractures (PTPFs). We evaluated the biomechanical performance of a novel plate and two conventional internal implants and investigated the anatomic feasibility of the novel plate. The fracture models were randomly assigned into six groups: Groups A\u2013C were the model groups of posterolateral split fracture, fixed with the posterior buttress plate, the lateral locking plate, and the novel plate, respectively. Groups D\u2013E were the model groups of posterolateral depression fracture, fixed with the posterior buttress plate, the lateral locking plate, and the novel plate, respectively. We evaluated the biomechanical performance of six model groups by the biomechanical testing and finite element analysis. Progressively increasing axial compressive loads were applied to each synthetic fracture model by using a customized indentor under 250\u2013750\u00a0N loads. Meanwhile, we dissected 12 fresh frozen knee specimens and fixed them with the novel plate through the anterolateral approach. We recorded the adjacency of the novel plate to important anatomic structures. Biomechanical testing showed that the novel plate had the least displacement, followed by the posterior buttress plate, and the lateral plate had the most displacement in posterolateral split fracture. There was no significant difference in the displacement between the novel plate and the lateral plate at different loads in posterolateral depression fractures. And the posterior buttress plate showed the most displacement. In the finite element analysis, the maximum stress values of Groups A, B, and C were 383.76, 414.63, and 305.07\u00a0MPa under the load of 750\u00a0N, respectively. The maximum stress values of Groups D, E, and F were 474.28, 436.31, and 413.4\u00a0MPa under the load of 750\u00a0N, respectively. In the anatomic study, the placement of the novel plate had a low risk of damage to the important anatomic structures of knee posterolateral corner. The novel plate could be a great choice for the treatment of PTPFs due to better biomechanical performance and easy manipulation.<\/jats:p>","DOI":"10.3389\/fbioe.2022.818610","type":"journal-article","created":{"date-parts":[[2022,3,8]],"date-time":"2022-03-08T06:57:31Z","timestamp":1646722651000},"update-policy":"https:\/\/doi.org\/10.3389\/crossmark-policy","source":"Crossref","is-referenced-by-count":25,"title":["The Study of Biomechanics and Clinical Anatomy on a Novel Plate Designed for Posterolateral Tibial Plateau Fractures via Anterolateral Approach"],"prefix":"10.3389","volume":"10","author":[{"given":"Weizhi","family":"Ren","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Wen","family":"Zhang","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Shijie","family":"Jiang","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Jian","family":"Peng","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Chang","family":"She","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Liubing","family":"Li","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Yongtao","family":"Mao","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Haibin","family":"Zhou","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Wei","family":"Xu","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"1965","published-online":{"date-parts":[[2022,3,8]]},"reference":[{"key":"B1","doi-asserted-by":"publisher","first-page":"323","DOI":"10.1097\/00005131-200205000-00006","article-title":"Failure of FIxation of Tibial Plateau Fractures","volume":"16","author":"Ali","year":"2002","journal-title":"J. Orthop. Trauma"},{"key":"B2","doi-asserted-by":"publisher","first-page":"825","DOI":"10.1016\/j.injury.2017.02.012","article-title":"Finite Element Analysis of the Three Different Posterior Malleolus Fixation Strategies in Relation to Different Fracture Sizes","volume":"48","author":"Anwar","year":"2017","journal-title":"Injury"},{"key":"B3","doi-asserted-by":"publisher","first-page":"73","DOI":"10.1186\/s12891-018-1989-7","article-title":"Biomechanical Efficacy of AP, PA Lag Screws and Posterior Plating for Fixation of Posterior Malleolar Fractures: A Three Dimensional Finite Element Study","volume":"19","author":"Anwar","year":"2018","journal-title":"BMC Musculoskelet. Disord."},{"key":"B4","doi-asserted-by":"publisher","first-page":"757","DOI":"10.1016\/j.injury.2013.11.028","article-title":"Postero-Medial Approach for Complex Tibial Plateau Injuries with a Postero-Medial or Postero-Lateral Shear Fragment","volume":"45","author":"Berber","year":"2014","journal-title":"Injury"},{"key":"B5","doi-asserted-by":"publisher","first-page":"955","DOI":"10.1007\/s00402-009-0829-5","article-title":"Treatment of Isolated Posterior Coronal Fracture of the Lateral Tibial Plateau through Posterolateral Approach for Direct Exposure and Buttress Plate Fixation","volume":"129","author":"Chang","year":"2009","journal-title":"Arch. Orthop. Trauma Surg."},{"key":"B6","doi-asserted-by":"publisher","first-page":"513","DOI":"10.1097\/bot.0000000000000047","article-title":"Open Reduction and Internal Fixation of Posterolateral Tibial Plateau Fractures through Fibula Osteotomy-Free Posterolateral Approach","volume":"28","author":"Chen","year":"2014","journal-title":"J. Orthop. Trauma"},{"key":"B7","doi-asserted-by":"publisher","first-page":"e362","DOI":"10.1097\/bot.0000000000000638","article-title":"Rim Plating of Posterolateral Fracture Fragments (PLFs) through a Modified Anterolateral Approach in Tibial Plateau Fractures","volume":"30","author":"Cho","year":"2016","journal-title":"J. Orthop. Trauma"},{"key":"B8","doi-asserted-by":"publisher","first-page":"1887","DOI":"10.1007\/s00264-017-3563-6","article-title":"Approaches and Fixation of the Posterolateral Fracture Fragment in Tibial Plateau Fractures: A Review with an Emphasis on Rim Plating via Modified Anterolateral Approach","volume":"41","author":"Cho","year":"2017","journal-title":"Int. Orthopaedics (Sicot)"},{"key":"B9","doi-asserted-by":"publisher","first-page":"508","DOI":"10.1097\/01.bot.0000180355.53196.f1","article-title":"The Posterior Shearing Tibial Plateau Fracture: Treatment and Results via a Posterior Approach","volume":"19","author":"Connolly","year":"2005","journal-title":"J. Orthop. Trauma"},{"key":"B10","doi-asserted-by":"publisher","first-page":"S7","DOI":"10.1016\/j.clinbiomech.2008.01.005","article-title":"Biomechanical and Histological Evaluation of the Application of Biodegradable Poly-L-Lactic Cushion to the Plate Internal Fixation for Bone Fracture Healing","volume":"23","author":"Fan","year":"2008","journal-title":"Clin. Biomech. (Bristol, Avon)"},{"key":"B11","doi-asserted-by":"publisher","first-page":"488","DOI":"10.1186\/s12891-021-04373-8","article-title":"A Posterolateral Sheared Fracture of the Tibial Plateau: A Case Presentation","volume":"22","author":"Feng","year":"2021","journal-title":"BMC Musculoskelet. Disord."},{"key":"B12","doi-asserted-by":"publisher","first-page":"1497","DOI":"10.1016\/j.injury.2016.04.021","article-title":"The Extended Posterolateral Approach for Split Depression Lateral Tibial Plateau Fractures Extending into the Posterior Column: 2 Years Follow up Results of a Prospective Study","volume":"47","author":"Gavaskar","year":"2016","journal-title":"Injury"},{"key":"B13","doi-asserted-by":"publisher","DOI":"10.1055\/s-0040-1721026","article-title":"Posterolateral Fractures of the Tibial Plateau Revisited: A Simplified Treatment Algorithm","author":"Giordano","year":"2020","journal-title":"J. Knee Surg"},{"key":"B14","doi-asserted-by":"publisher","first-page":"23","DOI":"10.1007\/s00402-012-1632-2","article-title":"A Posterior Inverted L-Shaped Approach for the Treatment of Posterior Bicondylar Tibial Plateau Fractures","volume":"133","author":"He","year":"2013","journal-title":"Arch. Orthop. Trauma Surg."},{"key":"B15","doi-asserted-by":"publisher","first-page":"221","DOI":"10.1097\/BOT.0b013e318271f8f0","article-title":"The Risk of Injury to the Anterior Tibial Artery in the Posterolateral Approach to the Tibia Plateau: A Cadaver Study","volume":"27","author":"Heidari","year":"2013","journal-title":"J. Orthop. Trauma"},{"key":"B16","doi-asserted-by":"publisher","first-page":"45","DOI":"10.1097\/BOT.0b013e31818f8dc1","article-title":"Incidence and Morphology of the Posteromedial Fragment in Bicondylar Tibial Plateau Fractures","volume":"23","author":"Higgins","year":"2009","journal-title":"J. Orthop. Trauma"},{"key":"B17","doi-asserted-by":"publisher","first-page":"2516","DOI":"10.1016\/j.injury.2015.10.014","article-title":"A Combined Posterior Reversed L-Shaped and Anterolateral Approach for Two Column Tibial Plateau Fractures in Caucasians: A Technical Note","volume":"46","author":"Hoekstra","year":"2015","journal-title":"Injury"},{"key":"B18","doi-asserted-by":"publisher","first-page":"637","DOI":"10.1007\/s00068-016-0696-z","article-title":"A Revised 3-Column Classification Approach for the Surgical Planning of Extended Lateral Tibial Plateau Fractures","volume":"43","author":"Hoekstra","year":"2017","journal-title":"Eur. J. Trauma Emerg. Surg."},{"key":"B19","doi-asserted-by":"publisher","first-page":"502","DOI":"10.1016\/j.injury.2015.11.010","article-title":"The Anterolateral Supra-Fibular-Head Approach for Plating Posterolateral Tibial Plateau Fractures: A Novel Surgical Technique","volume":"47","author":"Hu","year":"2016","journal-title":"Injury"},{"key":"B20","doi-asserted-by":"publisher","first-page":"4186712","DOI":"10.1155\/2020\/4186712","article-title":"Treatment of Isolated Posterolateral Tibial Plateau Fracture with a Horizontal Belt Plate through the Anterolateral Supra-Fibular-Head Approach","volume":"2020","author":"Hu","year":"2020","journal-title":"Biomed. Res. Int."},{"key":"B21","doi-asserted-by":"publisher","first-page":"203","DOI":"10.1016\/j.clinbiomech.2019.10.019","article-title":"Biomechanical Comparison of a 3D-Printed Sacrum Prosthesis versus Rod-Screw Systems for Reconstruction after Total Sacrectomy: A Finite Element Analysis","volume":"70","author":"Huang","year":"2019","journal-title":"Clin. Biomech."},{"key":"B22","doi-asserted-by":"publisher","first-page":"287","DOI":"10.1186\/s12891-016-1118-4","article-title":"Biomechanical Analysis of Different Osteosyntheses and the Combination with Bone Substitute in Tibial Head Depression Fractures","volume":"17","author":"Jordan","year":"2016","journal-title":"BMC Musculoskelet. Disord."},{"key":"B23","doi-asserted-by":"publisher","first-page":"2252","DOI":"10.1016\/j.injury.2018.11.010","article-title":"Revisiting the Schatzker Classification of Tibial Plateau Fractures","volume":"49","author":"Kfuri","year":"2018","journal-title":"Injury"},{"key":"B25","doi-asserted-by":"publisher","first-page":"854","DOI":"10.1177\/03635465030310062101","article-title":"The Posterolateral Attachments of the Knee: a Qualitative and Quantitative Morphologic Analysis of the Fibular Collateral Ligament, Popliteus Tendon, Popliteofibular Ligament, and Lateral Gastrocnemius Tendon","volume":"31","author":"LaPrade","year":"2003","journal-title":"Am. J. Sports Med."},{"key":"B26","doi-asserted-by":"publisher","first-page":"477","DOI":"10.1016\/j.otsr.2014.12.021","article-title":"Prone and Direct Posterior Approach for Management of Posterior Column Tibial Plateau Fractures","volume":"101","author":"Lin","year":"2015","journal-title":"Orthopaedics Traumatol. Surg. Res."},{"key":"B27","doi-asserted-by":"publisher","first-page":"117","DOI":"10.4103\/0019-5413.177578","article-title":"Results of a Modified Posterolateral Approach for the Isolated Posterolateral Tibial Plateau Fracture","volume":"50","author":"Liu","year":"2016","journal-title":"Indian J. Orthop."},{"key":"B28","doi-asserted-by":"publisher","first-page":"957","DOI":"10.1007\/s001130050218","article-title":"Particular Posteromedial and Posterolateral Approaches for the Treatment of Tibial Head Fractures","volume":"100","author":"Lobenhoffer","year":"1997","journal-title":"Unfallchirurg"},{"key":"B29","doi-asserted-by":"publisher","first-page":"683","DOI":"10.1097\/BOT.0b013e3181d436f3","article-title":"Three-Column Fixation for Complex Tibial Plateau Fractures","volume":"24","author":"Luo","year":"2010","journal-title":"J. Orthop. Trauma"},{"key":"B30","doi-asserted-by":"publisher","first-page":"1228","DOI":"10.1016\/j.medengphy.2011.05.012","article-title":"Finite Element Modeling of a 3D Coupled Foot-Boot Model","volume":"33","author":"Qiu","year":"2011","journal-title":"Med. Eng. Phys."},{"key":"B31","doi-asserted-by":"publisher","first-page":"1503","DOI":"10.1002\/jbm.820241107","article-title":"Friction Properties of the Interface between Porous-Surfaced Metals and Tibial Cancellous Bone","volume":"24","author":"Rancourt","year":"1990","journal-title":"J. Biomed. Mater. Res."},{"key":"B32","doi-asserted-by":"publisher","first-page":"e169","DOI":"10.1097\/bot.0000000000000020","article-title":"Fibular Shaft Allograft Support of Posterior Joint Depression in Tibial Plateau Fractures","volume":"28","author":"Sassoon","year":"2014","journal-title":"J. Orthop. Trauma"},{"key":"B24","doi-asserted-by":"publisher","first-page":"204","DOI":"10.1055\/s-0037-1598077","article-title":"Extended Anterolateral Approach for Complex Lateral Tibial Plateau Fractures","volume":"30","author":"Schatzker","year":"2017","journal-title":"J. Knee Surg."},{"key":"B33","doi-asserted-by":"publisher","first-page":"91","DOI":"10.1097\/bot.0000000000000170","article-title":"Incidence and Fracture Morphology of Posterolateral Fragments in Lateral and Bicondylar Tibial Plateau Fractures","volume":"29","author":"Sohn","year":"2015","journal-title":"J. Orthop. Trauma"},{"key":"B34","doi-asserted-by":"publisher","first-page":"505","DOI":"10.1097\/BOT.0b013e3181ccba4b","article-title":"Posterolateral Transfibular Approach to Tibial Plateau Fractures: Technique, Results, and Rationale","volume":"24","author":"Solomon","year":"2010","journal-title":"J. Orthop. Trauma"},{"key":"B35","doi-asserted-by":"publisher","first-page":"1561","DOI":"10.1016\/j.injury.2013.04.024","article-title":"Posterolateral and Anterolateral Approaches to Unicondylar Posterolateral Tibial Plateau Fractures: a Comparative Study","volume":"44","author":"Solomon","year":"2013","journal-title":"Injury"},{"key":"B36","doi-asserted-by":"publisher","first-page":"151413","DOI":"10.1016\/j.aanat.2019.151413","article-title":"Applied Anatomy and Three-Dimensional Visualization of the Tendon-Bone Junctions of the Knee Joint Posterolateral Complex","volume":"229","author":"Song","year":"2020","journal-title":"Ann. Anat. - Anatomischer Anzeiger"},{"key":"B37","doi-asserted-by":"publisher","first-page":"567","DOI":"10.1016\/j.knee.2012.10.025","article-title":"Morphological Measurements of the Posterior Surface of the normal Proximal Tibia in a Healthy Chinese Population","volume":"21","author":"Sun","year":"2014","journal-title":"Knee"},{"key":"B38","doi-asserted-by":"publisher","first-page":"2814","DOI":"10.1016\/j.injury.2017.10.033","article-title":"Reinforcement Strategy for Lateral Rafting Plate Fixation in Posterolateral Column Fractures of the Tibial Plateau: The Magic Screw Technique","volume":"48","author":"Sun","year":"2017","journal-title":"Injury"},{"key":"B39","doi-asserted-by":"publisher","first-page":"417","DOI":"10.1016\/j.knee.2018.03.015","article-title":"A Biomechanical Evaluation of Different Fixation Strategies for Posterolateral Fragments in Tibial Plateau Fractures and Introduction of the 'Magic Screw'","volume":"25","author":"Sun","year":"2018","journal-title":"Knee"},{"key":"B40","doi-asserted-by":"publisher","first-page":"625","DOI":"10.1016\/j.orthres.2003.09.003","article-title":"Tibio-Femoral Loading during Human Gait and Stair Climbing","volume":"22","author":"Taylor","year":"2004","journal-title":"J. Orthop. Res."},{"key":"B41","doi-asserted-by":"publisher","first-page":"1611","DOI":"10.1016\/s0021-9290(00)00140-8","article-title":"Large-Sliding Contact Elements Accurately Predict Levels of Bone-Implant Micromotion Relevant to Osseointegration","volume":"33","author":"Viceconti","year":"2000","journal-title":"J. Biomech."},{"key":"B42","doi-asserted-by":"publisher","first-page":"329","DOI":"10.1055\/s-0036-1584922","article-title":"An Innovative Intra-Articular Osteotomy in the Treatment of Posterolateral Tibial Plateau Fracture Malunion","volume":"30","author":"Wang","year":"2017","journal-title":"J. Knee Surg."},{"key":"B43","doi-asserted-by":"publisher","first-page":"222","DOI":"10.2106\/00004623-200302000-00007","article-title":"Experimental Tibial Plateau Fractures Augmented with Calcium Phosphate Cement or Autologous Bone Graft","volume":"85","author":"Welch","year":"2003","journal-title":"The J. Bone Jt. Surgery-American Volume"},{"key":"B44","doi-asserted-by":"publisher","first-page":"e1256","DOI":"10.3928\/01477447-20130920-16","article-title":"Morphological Characteristics of Posterolateral Articular Fragments in Tibial Plateau Fractures","volume":"36","author":"Xiang","year":"2013","journal-title":"Orthopedics"},{"key":"B45","doi-asserted-by":"publisher","first-page":"410","DOI":"10.2106\/jbjs.19.00485","article-title":"Comparative Analysis of Mechanism-Associated 3-Dimensional Tibial Plateau Fracture Patterns","volume":"102","author":"Xie","year":"2020","journal-title":"J. Bone Jt. Surg."},{"key":"B46","doi-asserted-by":"publisher","first-page":"723","DOI":"10.1016\/j.injury.2020.01.023","article-title":"A New Strategy to Fix Posterolateral Depression in Tibial Plateau Fractures: Introduction of a New Modified Frosch Approach and a \"Barrel Hoop Plate\" Technique","volume":"51","author":"Yi","year":"2020","journal-title":"Injury"},{"key":"B47","doi-asserted-by":"publisher","first-page":"1416","DOI":"10.1097\/TA.0b013e318248e7e5","article-title":"Low-Energy Fracture of Posterolateral Tibial Plateau: Treatment by a Posterolateral Prone Approach","volume":"72","author":"Yu","year":"2012","journal-title":"J. Trauma Acute Care Surg."},{"key":"B48","doi-asserted-by":"publisher","first-page":"94","DOI":"10.1016\/j.knee.2011.02.004","article-title":"Biomechanical Analysis of Four Different Fixations for the Posterolateral Shearing Tibial Plateau Fracture","volume":"19","author":"Zhang","year":"2012","journal-title":"The Knee"},{"key":"B49","doi-asserted-by":"publisher","first-page":"2326","DOI":"10.1016\/j.injury.2016.07.004","article-title":"A Combined Approach for the Treatment of Lateral and Posterolateral Tibial Plateau Fractures","volume":"47","author":"Zhang","year":"2016","journal-title":"Injury"},{"key":"B50","doi-asserted-by":"publisher","first-page":"2465","DOI":"10.1016\/j.injury.2020.07.059","article-title":"Biomechanical Analysis of \"Barrel Hoop Plate\" Technique for the Posterolateral Fragments of Tibial Plateau Fractures with Different Displacement Tendency","volume":"51","author":"Zhang","year":"2020","journal-title":"Injury"},{"key":"B51","doi-asserted-by":"publisher","first-page":"789","DOI":"10.1002\/jor.20379","article-title":"Correlation between the Knee Adduction Torque and Medial Contact Force for a Variety of Gait Patterns","volume":"25","author":"Zhao","year":"2007","journal-title":"J. Orthop. Res."},{"key":"B52","doi-asserted-by":"publisher","first-page":"48","DOI":"10.16156\/j.1004-7220.2021.01.008","article-title":"Analysis on Biomechanical Properties of Anterior Ligament Reinforcement Combined with Screw Fixation for Inferior Tibiofibular Instability","volume":"36","author":"Zhou","year":"2021","journal-title":"J. Med. Biomech."}],"container-title":["Frontiers in Bioengineering and Biotechnology"],"original-title":[],"link":[{"URL":"https:\/\/www.frontiersin.org\/articles\/10.3389\/fbioe.2022.818610\/full","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2022,3,8]],"date-time":"2022-03-08T06:57:36Z","timestamp":1646722656000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.frontiersin.org\/articles\/10.3389\/fbioe.2022.818610\/full"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2022,3,8]]},"references-count":52,"alternative-id":["10.3389\/fbioe.2022.818610"],"URL":"https:\/\/doi.org\/10.3389\/fbioe.2022.818610","relation":{},"ISSN":["2296-4185"],"issn-type":[{"value":"2296-4185","type":"electronic"}],"subject":[],"published":{"date-parts":[[2022,3,8]]},"article-number":"818610"}}