{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,9,22]],"date-time":"2026-09-22T22:42:35Z","timestamp":1790116955318,"version":"4.0.1"},"reference-count":35,"publisher":"Frontiers Media SA","license":[{"start":{"date-parts":[[2022,4,26]],"date-time":"2022-04-26T00:00:00Z","timestamp":1650931200000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"funder":[{"DOI":"10.13039\/100000002","name":"National Institutes of Health","doi-asserted-by":"publisher","id":[{"id":"10.13039\/100000002","id-type":"DOI","asserted-by":"publisher"}]}],"content-domain":{"domain":["frontiersin.org"],"crossmark-restriction":true},"short-container-title":["Front. Bioeng. Biotechnol."],"abstract":"<jats:p><jats:bold>Background:<\/jats:bold> Porcine heart and bovine pericardium valves, which are collagen-based with relatively little elastin, have been broadly utilized to construct bioprosthetic heart valves (BHVs). With a larger proportion of elastin, the pulmonary visceral pleura (PVP) has greater elasticity and could potentially serve as an advantageous biomaterial for the construction\/repair of BHVs. The question of how the aortic valve\u2019s performance is affected by its bending rigidity has not been well studied.<\/jats:p><jats:p><jats:bold>Methods:<\/jats:bold> Based on the stress\u2013strain relationships of the pericardium and PVP determined by planar uni-axial tests, a three-dimensional (3D) computational fluid\u2013structure interaction (FSI) framework is employed to numerically investigate the aortic valve\u2019s performance by considering three different cases with Young\u2019s modulus as follows: <jats:inline-formula><mml:math xmlns:mml=\"http:\/\/www.w3.org\/1998\/Math\/MathML\" id=\"m1\"><mml:mrow><mml:mi mathvariant=\"italic\">E<\/mml:mi><mml:mo>=<\/mml:mo><mml:mn>375<\/mml:mn><\/mml:mrow><\/mml:math><\/jats:inline-formula>, <jats:inline-formula><mml:math xmlns:mml=\"http:\/\/www.w3.org\/1998\/Math\/MathML\" id=\"m2\"><mml:mrow><mml:mn>750<\/mml:mn><\/mml:mrow><\/mml:math><\/jats:inline-formula>, and <jats:inline-formula><mml:math xmlns:mml=\"http:\/\/www.w3.org\/1998\/Math\/MathML\" id=\"m3\"><mml:mrow><mml:mn>1500<\/mml:mn><\/mml:mrow><\/mml:math><\/jats:inline-formula>\u00a0kPa, respectively.<\/jats:p><jats:p><jats:bold>Results:<\/jats:bold> The stroke volumes are 112, 99.6, and 91.4\u00a0ml as Young\u2019s modulus increases from 375 to 750 and 1500\u00a0kPa, respectively. Peak geometric opening area (GOA) values are 2.3, 2.2, and 2.0\u00a0cm<jats:sup>2<\/jats:sup> for <jats:inline-formula><mml:math xmlns:mml=\"http:\/\/www.w3.org\/1998\/Math\/MathML\" id=\"m4\"><mml:mrow><mml:mi mathvariant=\"italic\">E<\/mml:mi><mml:mo>=<\/mml:mo><mml:mn>375<\/mml:mn><\/mml:mrow><\/mml:math><\/jats:inline-formula>, 750, and 1500\u00a0kPa, respectively. The maximum value of the aortic leaflet stress is about 271\u00a0kPa for <jats:inline-formula><mml:math xmlns:mml=\"http:\/\/www.w3.org\/1998\/Math\/MathML\" id=\"m5\"><mml:mrow><mml:mi mathvariant=\"italic\">E<\/mml:mi><mml:mo>=<\/mml:mo><mml:mn>375<\/mml:mn><\/mml:mrow><\/mml:math><\/jats:inline-formula>\u00a0kPa, and it increases to about 383 and 540\u00a0kPa for <jats:inline-formula><mml:math xmlns:mml=\"http:\/\/www.w3.org\/1998\/Math\/MathML\" id=\"m6\"><mml:mrow><mml:mi mathvariant=\"italic\">E<\/mml:mi><mml:mo>=<\/mml:mo><mml:mn>750<\/mml:mn><\/mml:mrow><\/mml:math><\/jats:inline-formula> and 1500\u00a0kPa in the belly region at the peak systole, while it reduces from 550\u00a0kPa to 450 and 400\u00a0kPa for <jats:inline-formula><mml:math xmlns:mml=\"http:\/\/www.w3.org\/1998\/Math\/MathML\" id=\"m7\"><mml:mrow><mml:mi mathvariant=\"italic\">E<\/mml:mi><mml:mo>=<\/mml:mo><mml:mn>375<\/mml:mn><\/mml:mrow><\/mml:math><\/jats:inline-formula>, 750, and 1500\u00a0kPa, respectively, at the instant of peak \u201cwater-hammer\u201d.<\/jats:p><jats:p><jats:bold>Conclusion:<\/jats:bold> A more compliant PVP aortic leaflet valve with a smaller Young\u2019s modulus, <jats:inline-formula><mml:math xmlns:mml=\"http:\/\/www.w3.org\/1998\/Math\/MathML\" id=\"m8\"><mml:mi>E<\/mml:mi><\/mml:math><\/jats:inline-formula>, has a higher cardiac output, larger GOA, and lower hemodynamic resistance. Most importantly, the aortic leaflet stresses are substantially lower in the belly region within the higher compliance PVP aortic valve tissue during the systole phase, even though some stress increase is also found during the fast-closing phase due to the \u201cwater-hammer\u201d effect similar to that in the pericardial tissue. Future clinical studies will be conducted to test the hypothesis that the PVP-based valve leaflets with higher compliance will have lower fatigue or calcification rates due to the overall lower stress.<\/jats:p>","DOI":"10.3389\/fbioe.2022.869095","type":"journal-article","created":{"date-parts":[[2022,4,26]],"date-time":"2022-04-26T04:55:32Z","timestamp":1650948932000},"update-policy":"https:\/\/doi.org\/10.3389\/crossmark-policy","source":"Crossref","is-referenced-by-count":7,"title":["Aortic Leaflet Stresses Are Substantially Lower Using Pulmonary Visceral Pleura Than Pericardial Tissue"],"prefix":"10.3389","volume":"10","author":[{"given":"Ye","family":"Chen","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Xiao","family":"Lu","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Haoxiang","family":"Luo","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Ghassan S.","family":"Kassab","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"1965","published-online":{"date-parts":[[2022,4,26]]},"reference":[{"key":"B1","doi-asserted-by":"publisher","first-page":"103","DOI":"10.1016\/j.cma.2013.01.010","article-title":"Fluid-structure Interaction, Immersed Boundary-Finite Element Method Simulations of Bio-Prosthetic Heart Valves","volume":"257","author":"Borazjani","year":"2013","journal-title":"Computer Methods Appl. Mech. Eng."},{"key":"B2","doi-asserted-by":"publisher","first-page":"332","DOI":"10.1016\/j.jfluidstructs.2018.04.009","article-title":"A Computational Study of the Three-Dimensional Fluid-Structure Interaction of Aortic Valve","volume":"80","author":"Chen","year":"2018","journal-title":"J. Fluids Structures"},{"key":"B3","doi-asserted-by":"publisher","DOI":"10.1017\/jfm.2019.904","article-title":"Pressure Distribution over the Leaflets and Effect of Bending Stiffness on Fluid\u2013Structure Interaction of the Aortic Valve","volume":"883","author":"Chen","year":"2020","journal-title":"J. Fluid Mech."},{"key":"B4","doi-asserted-by":"publisher","first-page":"310","DOI":"10.1007\/s10439-016-1759-3","article-title":"On the Mechanics of Transcatheter Aortic Valve Replacement","volume":"45","author":"Dasi","year":"2017","journal-title":"Ann. Biomed. Eng."},{"key":"B5","doi-asserted-by":"publisher","first-page":"1159","DOI":"10.1016\/0002-9149(78)90873-1","article-title":"Structural Changes in Glutaraldehyde-Treated Porcine Heterografts Used as Substitute Cardiac Valves","volume":"41","author":"Ferrans","year":"1978","journal-title":"Am. J. Cardiol."},{"key":"B6","doi-asserted-by":"publisher","first-page":"552","DOI":"10.1177\/0885328212465482","article-title":"A Comparative Study of Bovine and Porcine Pericardium to Highlight Their Potential Advantages to Manufacture Percutaneous Cardiovascular Implants","volume":"28","author":"Gauvin","year":"2013","journal-title":"J. Biomater. Appl."},{"key":"B7","doi-asserted-by":"publisher","first-page":"119","DOI":"10.3390\/fluids4030119","article-title":"Image-guided Fluid-Structure Interaction Simulation of Transvalvular Hemodynamics: Quantifying the Effects of Varying Aortic Valve Leaflet Thickness","volume":"43","author":"Gilmanov","year":"2019","journal-title":"Fluids"},{"key":"B8","doi-asserted-by":"publisher","first-page":"814","DOI":"10.1016\/j.jcp.2015.08.008","article-title":"A Numerical Approach for Simulating Fluid Structure Interaction of Flexible Thin Shells Undergoing Arbitrarily Large Deformations in Complex Domains","volume":"300","author":"Gilmanov","year":"2015","journal-title":"J. Comput. Phys."},{"key":"B9","doi-asserted-by":"publisher","first-page":"67","DOI":"10.1007\/s00162-015-0364-7","article-title":"Comparative Hemodynamics in an Aorta with Bicuspid and Trileaflet Valves","volume":"30","author":"Gilmanov","year":"2016","journal-title":"Theor. Comput. Fluid Dyn."},{"key":"B10","doi-asserted-by":"publisher","first-page":"317","DOI":"10.1002\/cnm.1445","article-title":"Immersed Boundary Model of Aortic Heart Valve Dynamics with Physiological Driving and Loading Conditions","volume":"28","author":"Griffith","year":"2012","journal-title":"Int. J. Numer. Meth. Biomed. Engng."},{"key":"B11","doi-asserted-by":"publisher","first-page":"137","DOI":"10.1142\/s1758825109000113","article-title":"Simulating the Fluid Dynamics of Natural and Prosthetic Heart Valves Using the Immersed Boundary Method","volume":"1","author":"Griffith","year":"2009","journal-title":"Int. J. Appl. Mech."},{"key":"B12","volume-title":"Hole\u2019s Human Anatomy & Physiology","author":"Hole","year":"1996"},{"key":"B13","doi-asserted-by":"publisher","first-page":"1211","DOI":"10.1007\/s00466-015-1166-x","article-title":"Dynamic and Fluid-Structure Interaction Simulations of Bioprosthetic Heart Valves Using Parametric Design with T-Splines and Fung-type Material Models","volume":"55","author":"Hsu","year":"2015","journal-title":"Comput. Mech."},{"key":"B14","doi-asserted-by":"publisher","first-page":"1005","DOI":"10.1016\/j.cma.2014.10.040","article-title":"An Immersogeometric Variational Framework for Fluid-Structure Interaction: Application to Bioprosthetic Heart Valves","volume":"284","author":"Kamensky","year":"2015","journal-title":"Computer Methods Appl. Mech. Eng."},{"key":"B15","doi-asserted-by":"publisher","first-page":"844","DOI":"10.1007\/s10439-014-1191-5","article-title":"Emerging Trends in Heart Valve Engineering: Part II. Novel and Standard Technologies for Aortic Valve Replacement","volume":"43","author":"Kheradvar","year":"2015","journal-title":"Ann. Biomed. Eng."},{"key":"B16","doi-asserted-by":"publisher","first-page":"262","DOI":"10.1007\/s10439-007-9409-4","article-title":"Dynamic Simulation of Bioprosthetic Heart Valves Using a Stress Resultant Shell Model","volume":"362","author":"Kim","year":"2008","journal-title":"Ann. Biomed. Eng."},{"key":"B17","first-page":"81","article-title":"Leaflet Mechanical Properties of Carpentier-Edwards Perimount Magna Pericardial Aortic Bioprostheses","volume":"261","author":"Kuang","year":"2017","journal-title":"J. Heart Valve Dis."},{"key":"B18","doi-asserted-by":"publisher","first-page":"254","DOI":"10.1016\/s0305-4179(00)00113-3","article-title":"Porcine Small Intestinal Submucosa (SIS): a Bioscaffold Supporting In Vitro Primary Human Epidermal Cell Differentiation and Synthesis of Basement Membrane Proteins","volume":"27","author":"Lindberg","year":"2001","journal-title":"Burns"},{"key":"B19","doi-asserted-by":"publisher","first-page":"458","DOI":"10.1016\/j.jvsv.2019.09.011","article-title":"Homologous and Heterologous Assessment of a Novel Biomaterial for Venous Patch","volume":"83","author":"Lu","year":"2020","journal-title":"J. Vasc. Surg. Venous Lymphatic Disord."},{"key":"B20","doi-asserted-by":"publisher","first-page":"61","DOI":"10.1016\/j.compfluid.2011.11.015","article-title":"On the Numerical Oscillation of the Direct-Forcing Immersed-Boundary Method for Moving Boundaries","volume":"56","author":"Luo","year":"2012","journal-title":"Comput. Fluids"},{"key":"B21","doi-asserted-by":"publisher","first-page":"213","DOI":"10.1016\/j.actbio.2005.11.004","article-title":"Biochemical and Mechanical Behavior of Ostrich Pericardium as a New Biomaterial","volume":"2","author":"Maestro","year":"2006","journal-title":"Acta Biomater."},{"key":"B22","first-page":"150","article-title":"The Future of Bioprosthetic Heart Valves","volume":"135","author":"Manji","year":"2012","journal-title":"Indian J. Med. Res."},{"key":"B23","doi-asserted-by":"publisher","first-page":"374","DOI":"10.1007\/s13239-016-0285-7","article-title":"Fluid-Structure Interaction Study of Transcatheter Aortic Valve Dynamics Using Smoothed Particle Hydrodynamics","volume":"7","author":"Mao","year":"2016","journal-title":"Cardiovasc. Eng. Tech."},{"key":"B24","doi-asserted-by":"publisher","first-page":"101001","DOI":"10.1115\/1.4024824","article-title":"Fluid-structure Interaction Model of Aortic Valve with Porcine-specific Collagen Fiber Alignment in the Cusps","volume":"135","author":"Marom","year":"2013","journal-title":"J. Biomech. Eng."},{"key":"B25","doi-asserted-by":"publisher","first-page":"100038","DOI":"10.1016\/j.mtbio.2019.100038","article-title":"Materials and Manufacturing Perspectives in Engineering Heart Valves: a Review","volume":"5","author":"Oveissi","year":"2020","journal-title":"Mater. Today Bio"},{"key":"B26","doi-asserted-by":"publisher","first-page":"20190893","DOI":"10.1098\/rsif.2019.0893","article-title":"The Role of Stress Concentration in Calcified Bicuspid Aortic Valve","volume":"17167","author":"Qin","year":"2020","journal-title":"J. R. Soc. Interf."},{"key":"B27","doi-asserted-by":"publisher","first-page":"181","DOI":"10.1016\/0021-9290(90)90351-3","article-title":"The Geometry of the Aortic Root in Health, at Valve Disease and after Valve Replacement","volume":"23","author":"Reul","year":"1990","journal-title":"J. Biomech."},{"key":"B28","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1080\/00015458.2002.11679253","article-title":"Mechanical Stress as Cause of Aortic Valve Disease Presentation of a New Aortic Root Prosthesis","volume":"102","author":"Robicsek","year":"2002","journal-title":"Acta Chirurgica Belgica"},{"key":"B29","doi-asserted-by":"publisher","first-page":"1072","DOI":"10.1016\/j.athoracsur.2004.06.033","article-title":"Calcification of Tissue Heart Valve Substitutes: Progress toward Understanding and Prevention","volume":"79","author":"Schoen","year":"2005","journal-title":"Ann. Thorac. Surg."},{"key":"B30","first-page":"290","article-title":"Age-related Changes in the Aortic Valve Affect Leaflet Stress Distributions: Implications for Aortic Valve Degeneration","volume":"17","author":"Singh","year":"2008","journal-title":"J. Heart Valve Dis."},{"key":"B31","doi-asserted-by":"publisher","first-page":"110239","DOI":"10.1016\/j.jbiomech.2021.110239","article-title":"Fluid-structure Coupled Biotransport Processes in Aortic Valve Disease","volume":"117","author":"Soltany Sadrabadi","year":"2021","journal-title":"J. Biomech."},{"key":"B32","doi-asserted-by":"publisher","first-page":"871","DOI":"10.1161\/01.res.35.6.871","article-title":"Dimensions and Geometric Relationships of the Human Aortic Value as a Function of Pressure","volume":"35","author":"Swanson","year":"1974","journal-title":"Circ. Res."},{"key":"B33","doi-asserted-by":"publisher","first-page":"115","DOI":"10.1016\/s0022-5223(19)39217-7","article-title":"Role of Mechanical Stress in Calcification of Aortic Bioprosthetic Valves","volume":"86","author":"Thubrikar","year":"1983","journal-title":"J. Thorac. Cardiovasc. Surg."},{"key":"B34","doi-asserted-by":"publisher","first-page":"451","DOI":"10.1016\/j.jcp.2013.10.047","article-title":"Fluid-structure Interaction Involving Large Deformations: 3D Simulations and Applications to Biological Systems","volume":"258","author":"Tian","year":"2014","journal-title":"J. Comput. Phys."},{"key":"B35","doi-asserted-by":"publisher","first-page":"37","DOI":"10.1007\/s10558-005-3072-x","article-title":"On the Constitutive Models for Heart Valve Leaflet Mechanics","volume":"5","author":"Weinberg","year":"2005","journal-title":"Cardiovasc. Eng."}],"container-title":["Frontiers in Bioengineering and Biotechnology"],"original-title":[],"link":[{"URL":"https:\/\/www.frontiersin.org\/articles\/10.3389\/fbioe.2022.869095\/full","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2022,4,26]],"date-time":"2022-04-26T04:55:39Z","timestamp":1650948939000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.frontiersin.org\/articles\/10.3389\/fbioe.2022.869095\/full"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2022,4,26]]},"references-count":35,"alternative-id":["10.3389\/fbioe.2022.869095"],"URL":"https:\/\/doi.org\/10.3389\/fbioe.2022.869095","relation":{},"ISSN":["2296-4185"],"issn-type":[{"value":"2296-4185","type":"electronic"}],"subject":[],"published":{"date-parts":[[2022,4,26]]},"article-number":"869095"}}