{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,4,11]],"date-time":"2026-04-11T15:41:32Z","timestamp":1775922092981,"version":"3.50.1"},"reference-count":35,"publisher":"Frontiers Media SA","license":[{"start":{"date-parts":[[2022,5,3]],"date-time":"2022-05-03T00:00:00Z","timestamp":1651536000000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"funder":[{"DOI":"10.13039\/100000002","name":"National Institutes of Health","doi-asserted-by":"publisher","award":["T32GM136651"],"award-info":[{"award-number":["T32GM136651"]}],"id":[{"id":"10.13039\/100000002","id-type":"DOI","asserted-by":"publisher"}]}],"content-domain":{"domain":["frontiersin.org"],"crossmark-restriction":true},"short-container-title":["Front. Bioeng. Biotechnol."],"abstract":"<jats:p>A stroke volume of arterial blood that arrives to the brain housed in the rigid cranium must be matched over the cardiac cycle by an equivalent volume of ejected venous blood. We hypothesize that the brain maintains this equilibrium by organizing coherent arterial and venous pulse waves. To test this hypothesis, we applied wavelet computational methods to diagnostic cerebral angiograms in four human patients, permitting the capture and analysis of cardiac frequency phenomena from fluoroscopic images acquired at faster than cardiac rate. We found that the cardiac frequency reciprocal phase of a small region of interest (ROI) in a named artery predicts venous anatomy pixel-wise and that the predicted pixels reconstitute venous bolus passage timing. Likewise, a small ROI in a named vein predicts arterial anatomy and arterial bolus passage timing. The predicted arterial and venous pixel groups maintain phase complementarity across the bolus travel. We thus establish a novel computational method to analyze vascular pulse waves from minimally invasive cerebral angiograms and provide the first direct evidence of arteriovenous coupling in the intact human brain. This phenomenon of arteriovenous coupling may be a physiologic mechanism for how the brain precisely maintains mechanical equilibrium against volume displacement and kinetic energy transfer resulting from cyclical deformations with each heartbeat. The study also paves the way to study deranged arteriovenous coupling as an underappreciated pathophysiologic disturbance in a myriad of neurological pathologies linked by mechanical disequilibrium.<\/jats:p>","DOI":"10.3389\/fbioe.2022.873530","type":"journal-article","created":{"date-parts":[[2022,5,3]],"date-time":"2022-05-03T04:47:08Z","timestamp":1651553228000},"update-policy":"https:\/\/doi.org\/10.3389\/crossmark-policy","source":"Crossref","is-referenced-by-count":5,"title":["Angiographic Pulse Wave Coherence in the Human Brain"],"prefix":"10.3389","volume":"10","author":[{"given":"Matthew J.","family":"Koch","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Phan Q.","family":"Duy","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Benjamin L.","family":"Grannan","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Aman B.","family":"Patel","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Scott B.","family":"Raymond","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Pankaj K.","family":"Agarwalla","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Kristopher T.","family":"Kahle","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"William E.","family":"Butler","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"1965","published-online":{"date-parts":[[2022,5,3]]},"reference":[{"key":"B1","first-page":"485","article-title":"Effects of Filtering on Multi-Site Photoplethysmography Pulse Waveform Characteristics","volume-title":"Computers in Cardiology","author":"Allen","year":"2004"},{"key":"B2","doi-asserted-by":"publisher","first-page":"21777","DOI":"10.37622\/ijaer\/10.9.2015.21777-21783","article-title":"Reviewing Otsu's Method for Image Thresholding","volume":"10","author":"Bangare","year":"2015","journal-title":"Int. J. Appl. Eng. Res."},{"key":"B3","doi-asserted-by":"publisher","first-page":"1383","DOI":"10.1007\/s10554-014-0471-3","article-title":"Intra-vascular Blood Velocity and Volumetric Flow Rate Calculated from Dynamic 4D CT Angiography Using a Time of Flight Technique","volume":"30","author":"Barfett","year":"2014","journal-title":"Int. J. Cardiovasc. Imaging"},{"key":"B4","volume-title":"Handbook of MRI Pulse Sequences","author":"Bernstein","year":"2004"},{"key":"B5","first-page":"389","article-title":"Analysis of Cerebrospinal Fluid Flow Waveforms with Gated Phase-Contrast MR Velocity Measurements","volume":"16","author":"Bhadelia","year":"1995","journal-title":"AJNR. Am. J. Neuroradiol."},{"key":"B6","doi-asserted-by":"publisher","first-page":"258","DOI":"10.1007\/s002340050404","article-title":"Cerebrospinal Fluid Pulsation Amplitude and its Quantitative Relationship to Cerebral Blood Flow Pulsations: a Phase-Contrast MR Flow Imaging Study","volume":"39","author":"Bhadelia","year":"1997","journal-title":"Neuroradiology"},{"key":"B7","doi-asserted-by":"publisher","first-page":"e0181025","DOI":"10.1371\/journal.pone.0181025","article-title":"CSF in the Ventricles of the Brain Behaves as a Relay Medium for Arteriovenous Pulse Wave Phase Coupling","volume":"12","author":"Butler","year":"2017","journal-title":"PLoS One"},{"key":"B8","doi-asserted-by":"publisher","first-page":"e0187014","DOI":"10.1371\/journal.pone.0187014","article-title":"Wavelet Brain Angiography Suggests Arteriovenous Pulse Wave Phase Locking","volume":"12","author":"Butler","year":"2017","journal-title":"PLoS One"},{"key":"B9","doi-asserted-by":"publisher","first-page":"1487","DOI":"10.1152\/physrev.00022.2020","article-title":"Regulation of Cerebral Blood Flow in Humans: Physiology and Clinical Implications of Autoregulation","volume":"101","author":"Claassen","year":"2021","journal-title":"Physiol. Rev."},{"key":"B10","doi-asserted-by":"publisher","first-page":"753","DOI":"10.1007\/s00234-007-0252-y","article-title":"Complications of Cerebral Angiography: a Prospective Analysis of 2,924 Consecutive Procedures","volume":"49","author":"Dawkins","year":"2007","journal-title":"Neuroradiology"},{"key":"B11","doi-asserted-by":"publisher","first-page":"537","DOI":"10.3390\/life11060537","article-title":"Abnormal Intracranial Pulse Pressure Amplitude Despite Normalized Static Intracranial Pressure in Idiopathic Intracranial Hypertension Refractory to Conservative Medical Therapy","volume":"11","author":"Eide","year":"2021","journal-title":"Life (Basel)"},{"key":"B12","doi-asserted-by":"publisher","first-page":"56","DOI":"10.1016\/j.seizure.2015.01.012","article-title":"Wavelet-based EEG Processing for Computer-Aided Seizure Detection and Epilepsy Diagnosis","volume":"26","author":"Faust","year":"2015","journal-title":"Seizure"},{"key":"B13","doi-asserted-by":"crossref","DOI":"10.1016\/B978-0-323-43140-8.00001-9","article-title":"Landmarks in the History of Neurosurgery","volume-title":"Principles of Neurological Surgery","author":"Goodrich","year":"2018"},{"key":"B14","doi-asserted-by":"publisher","first-page":"931","DOI":"10.1007\/s10237-015-0662-4","article-title":"Mechanics of the Brain: Perspectives, Challenges, and Opportunities","volume":"14","author":"Goriely","year":"2015","journal-title":"Biomech. Model. Mechanobiol."},{"key":"B15","doi-asserted-by":"publisher","first-page":"78","DOI":"10.5469\/neuroint.2016.11.2.78","article-title":"Patient Radiation Exposure during Diagnostic and Therapeutic Procedures for Intracranial Aneurysms: A Multicenter Study","volume":"11","author":"Ihn","year":"2016","journal-title":"Neurointervention"},{"key":"B16","doi-asserted-by":"publisher","first-page":"1881","DOI":"10.1118\/1.1286552","article-title":"ECG-correlated Image Reconstruction from Subsecond Multi-Slice Spiral CT Scans of the Heart","volume":"27","author":"Kachelriess","year":"2000","journal-title":"Med. Phys."},{"key":"B17","doi-asserted-by":"publisher","first-page":"343","DOI":"10.1007\/978-3-7091-6475-4_99","article-title":"Cine MR CSF Flow Study in Hydrocephalus: what Are the Valuable Parameters?","volume":"71","author":"Kim","year":"1998","journal-title":"Acta Neurochir. Suppl."},{"key":"B18","doi-asserted-by":"publisher","first-page":"2044","DOI":"10.1161\/strokeaha.118.023851","article-title":"Identification and Validation of Hematoma Volume Cutoffs in Spontaneous, Supratentorial Deep Intracerebral Hemorrhage","volume":"50","author":"Leasure","year":"2019","journal-title":"Stroke"},{"key":"B19","doi-asserted-by":"publisher","first-page":"074001","DOI":"10.1088\/1361-6579\/ac0a34","article-title":"Filtering-induced Time Shifts in Photoplethysmography Pulse Features Measured at Different Body Sites: the Importance of Filter Definition and Standardization","volume":"42","author":"Liu","year":"","journal-title":"Physiol. Meas."},{"key":"B20","doi-asserted-by":"publisher","first-page":"094001","DOI":"10.1088\/1361-6579\/abaaf0","article-title":"Comparison of Different Modulations of Photoplethysmography in Extracting Respiratory Rate: from a Physiological Perspective","volume":"41","author":"Liu","year":"","journal-title":"Physiol. Meas."},{"key":"B21","doi-asserted-by":"publisher","first-page":"1464","DOI":"10.3389\/fphys.2021.782647","article-title":"Comparison of Newtonian and Non-newtonian Fluid Models in Blood Flow Simulation in Patients with Intracranial Arterial Stenosis","volume":"12","author":"Liu","year":"","journal-title":"Front. Physiol."},{"key":"B22","doi-asserted-by":"publisher","first-page":"156261","DOI":"10.1109\/access.2020.3007737","article-title":"State-of-the-Art Computational Models of Circle of Willis with Physiological Applications: A Review","volume":"8","author":"Liu","year":"","journal-title":"IEEE Access"},{"key":"B23","doi-asserted-by":"publisher","first-page":"1015","DOI":"10.1002\/jmri.23632","article-title":"4D Flow MRI","volume":"36","author":"Markl","year":"2012","journal-title":"J. Magn. Reson. Imaging"},{"key":"B24","doi-asserted-by":"publisher","first-page":"2975","DOI":"10.1118\/1.3589132","article-title":"Sub-Nyquist Acquisition and Constrained Reconstruction in Time Resolved Angiography","volume":"38","author":"Mistretta","year":"2011","journal-title":"Med. Phys."},{"key":"B25","doi-asserted-by":"publisher","first-page":"617","DOI":"10.1109\/t-aiee.1928.5055024","article-title":"Certain Topics in Telegraph Transmission Theory","volume":"47","author":"Nyquist","year":"1928","journal-title":"Trans. Am. Inst. Electr. Eng."},{"key":"B26","doi-asserted-by":"publisher","first-page":"1189","DOI":"10.3171\/2012.9.jns121227","article-title":"Impaired Pulsation Absorber Mechanism in Idiopathic normal Pressure Hydrocephalus","volume":"117","author":"Park","year":"2012","journal-title":"Jns"},{"key":"B27","doi-asserted-by":"publisher","first-page":"563","DOI":"10.1097\/00004424-197711000-00019","article-title":"Gated Computed Tomography of the Human Heart","volume":"12","author":"Sagel","year":"1977","journal-title":"Invest. Radiol."},{"key":"B28","doi-asserted-by":"publisher","first-page":"10","DOI":"10.1109\/jrproc.1949.232969","article-title":"Communication in the Presence of Noise","volume":"37","author":"Shannon","year":"1949","journal-title":"Proc. IRE"},{"key":"B29","doi-asserted-by":"publisher","first-page":"69","DOI":"10.1016\/j.brainres.2010.01.032","article-title":"RBC Velocities in Single Capillaries of Mouse and Rat Brains Are the Same, Despite 10-fold Difference in Body Size","volume":"1320","author":"Unekawa","year":"2010","journal-title":"Brain Res."},{"key":"B30","volume-title":"On the Transmission Capacity of the \u201cEther\u201d and of Cables in Electrical Communications","year":"1933"},{"key":"B31","doi-asserted-by":"publisher","first-page":"5","DOI":"10.1186\/2045-8118-8-5","article-title":"The Pulsating Brain: A Review of Experimental and Clinical Studies of Intracranial Pulsatility","volume":"8","author":"Wagshul","year":"2011","journal-title":"Fluids Barriers CNS"},{"key":"B32","doi-asserted-by":"publisher","first-page":"17804","DOI":"10.1073\/pnas.0503082102","article-title":"Perfusion Functional MRI Reveals Cerebral Blood Flow Pattern under Psychological Stress","volume":"102","author":"Wang","year":"2005","journal-title":"Proc. Natl. Acad. Sci. U.S.A."},{"key":"B33","doi-asserted-by":"publisher","first-page":"695","DOI":"10.1007\/bf00542361","article-title":"Use of Gamma Distributed Residence Times in Pharmacokinetics","volume":"25","author":"Weiss","year":"1983","journal-title":"Eur. J. Clin. Pharmacol."},{"key":"B34","doi-asserted-by":"publisher","first-page":"187","DOI":"10.1088\/0143-0815\/10\/3\/001","article-title":"Reference Values for Resting Blood Flow to Organs of Man","volume":"10","author":"Williams","year":"1989","journal-title":"Clin. Phys. Physiol. Meas."},{"key":"B35","doi-asserted-by":"publisher","first-page":"1338","DOI":"10.1177\/0271678x16648711","article-title":"Monro-Kellie 2.0: The Dynamic Vascular and Venous Pathophysiological Components of Intracranial Pressure","volume":"36","author":"Wilson","year":"2016","journal-title":"J. Cereb. Blood Flow Metab."}],"container-title":["Frontiers in Bioengineering and Biotechnology"],"original-title":[],"link":[{"URL":"https:\/\/www.frontiersin.org\/articles\/10.3389\/fbioe.2022.873530\/full","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2022,5,3]],"date-time":"2022-05-03T04:47:12Z","timestamp":1651553232000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.frontiersin.org\/articles\/10.3389\/fbioe.2022.873530\/full"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2022,5,3]]},"references-count":35,"alternative-id":["10.3389\/fbioe.2022.873530"],"URL":"https:\/\/doi.org\/10.3389\/fbioe.2022.873530","relation":{},"ISSN":["2296-4185"],"issn-type":[{"value":"2296-4185","type":"electronic"}],"subject":[],"published":{"date-parts":[[2022,5,3]]},"article-number":"873530"}}