{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,7,2]],"date-time":"2026-07-02T20:42:14Z","timestamp":1783024934242,"version":"3.54.6"},"reference-count":29,"publisher":"Frontiers Media SA","license":[{"start":{"date-parts":[[2022,5,26]],"date-time":"2022-05-26T00:00:00Z","timestamp":1653523200000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"funder":[{"DOI":"10.13039\/501100001659","name":"Deutsche Forschungsgemeinschaft","doi-asserted-by":"publisher","award":["SFB1340 GRK2260"],"award-info":[{"award-number":["SFB1340 GRK2260"]}],"id":[{"id":"10.13039\/501100001659","id-type":"DOI","asserted-by":"publisher"}]},{"DOI":"10.13039\/100004319","name":"Pfizer","doi-asserted-by":"publisher","award":["WP2487656"],"award-info":[{"award-number":["WP2487656"]}],"id":[{"id":"10.13039\/100004319","id-type":"DOI","asserted-by":"publisher"}]}],"content-domain":{"domain":["frontiersin.org"],"crossmark-restriction":true},"short-container-title":["Front. Bioeng. Biotechnol."],"abstract":"<jats:p>Ultrasound elastography quantitatively measures tissue stiffness and is widely used in clinical practice to diagnose various diseases including liver fibrosis and portal hypertension. The stiffness of soft organs has been shown to be sensitive to blood flow and pressure-related diseases such as portal hypertension. Because of the intricate coupling between tissue stiffness of abdominal organs and perfusion-related factors such as vascular stiffness or blood volume, simple breathing maneuvers have altered the results of liver elastography, while other organs such as the spleen are understudied. Therefore, we investigated the effect of a standardized Valsalva maneuver on liver stiffness and, for the first time, on spleen stiffness using time-harmonic elastography (THE). THE acquires full-field-of-view stiffness maps based on shear wave speed (SWS), covers deep tissues, and is potentially sensitive to SWS changes induced by altered abdominal pressure in the hepatosplenic system. SWS of the liver and the spleen was measured in 17 healthy volunteers under baseline conditions and during the Valsalva maneuver. With the Valsalva maneuver, SWS in the liver decreased by 2.2% (from a median of 1.36\u00a0m\/s to 1.32\u00a0m\/s; <jats:italic>p<\/jats:italic> = 0.021), while SWS in the spleen decreased by 5.2% (from a median of 1.63\u00a0m\/s to 1.51\u00a0m\/s; <jats:italic>p<\/jats:italic> = 0.00059). Furthermore, we observed that the decrease was more pronounced the higher the baseline SWS values were. In conclusion, the results confirm our hypothesis that the Valsalva maneuver decreases liver and spleen stiffness, showing that THE is sensitive to perfusion pressure-related changes in tissue stiffness. With its extensive organ coverage and high penetration depth, THE may facilitate translation of pressure-sensitive ultrasound elastography into clinical routine.<\/jats:p>","DOI":"10.3389\/fbioe.2022.886363","type":"journal-article","created":{"date-parts":[[2022,6,1]],"date-time":"2022-06-01T05:11:28Z","timestamp":1654060288000},"update-policy":"https:\/\/doi.org\/10.3389\/crossmark-policy","source":"Crossref","is-referenced-by-count":19,"title":["Valsalva Maneuver Decreases Liver and Spleen Stiffness Measured by Time-Harmonic Ultrasound Elastography"],"prefix":"10.3389","volume":"10","author":[{"given":"Tom","family":"Meyer","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Heiko","family":"Tzsch\u00e4tzsch","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Brunhilde","family":"Wellge","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Ingolf","family":"Sack","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Thomas","family":"Kr\u00f6ncke","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Alma","family":"Martl","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"1965","published-online":{"date-parts":[[2022,5,26]]},"reference":[{"key":"B1","doi-asserted-by":"publisher","first-page":"1127","DOI":"10.1007\/s00261-018-1795-6","article-title":"Shear Wave Elastography Prior to Transjugular Intrahepatic Portosystemic Shunt May Predict the Decrease in Hepatic Vein Pressure Gradient","volume":"44","author":"Attia","year":"2019","journal-title":"Abdom. Radiol."},{"key":"B2","doi-asserted-by":"publisher","first-page":"54","DOI":"10.1016\/j.dld.2017.09.138","article-title":"Spleen Stiffness Is Positively Correlated with HVPG and Decreases Significantly after TIPS Implantation","volume":"50","author":"Buechter","year":"2018","journal-title":"Dig. Liver Dis."},{"key":"B3","doi-asserted-by":"publisher","first-page":"992","DOI":"10.1097\/meg.0000000000000393","article-title":"Liver and Spleen Stiffness and Other Noninvasive Methods to Assess Portal Hypertension in Cirrhotic Patients","volume":"27","author":"Colecchia","year":"2015","journal-title":"Eur. J. Gastroenterology Hepatology"},{"key":"B4","doi-asserted-by":"publisher","first-page":"216","DOI":"10.1179\/acb.2009.038","article-title":"Intra-abdominal and Abdominal Perfusion Pressure in Patients Undergoing Coronary Artery Bypass Graft Surgery","volume":"64","author":"Dabrowski","year":"2009","journal-title":"Acta Clin. Belg."},{"key":"B5","doi-asserted-by":"publisher","first-page":"704","DOI":"10.1111\/jgh.13907","article-title":"Modification of Splenic Stiffness on Acoustic Radiation Force Impulse Parallels the Variation of Portal Pressure Induced by Transjugular Intrahepatic Portosystemic Shunt","volume":"33","author":"De Santis","year":"2018","journal-title":"J. Gastroenterology Hepatology"},{"key":"B6","doi-asserted-by":"publisher","first-page":"e16","DOI":"10.1055\/s-0043-103952","article-title":"EFSUMB Guidelines and Recommendations on the Clinical Use of Liver Ultrasound Elastography, Update 2017 (Long Version)","volume":"38","author":"Dietrich","year":"2017","journal-title":"Ultraschall Med"},{"key":"B7","doi-asserted-by":"publisher","first-page":"976","DOI":"10.1002\/mrm.26484","article-title":"Tomoelastography of the Abdomen: Tissue Mechanical Properties of the Liver, Spleen, Kidney, and Pancreas from Single MR Elastography Scans at Different Hydration States","volume":"78","author":"Dittmann","year":"2017","journal-title":"Magn. Reson. Med."},{"key":"B8","doi-asserted-by":"publisher","first-page":"135","DOI":"10.1016\/j.clinimag.2011.11.014","article-title":"The Stiffness of the Liver and Spleen on ARFI Imaging Pre and Post TIPS Placement: a Preliminary Observation","volume":"36","author":"Gao","year":"2012","journal-title":"Clin. Imaging"},{"key":"B9","doi-asserted-by":"publisher","first-page":"380","DOI":"10.1055\/s-0032-1312816","article-title":"Impact of Food Intake, Ultrasound Transducer, Breathing Maneuvers and Body Position on Acoustic Radiation Force Impulse (ARFI) Elastometry of the Liver","volume":"33","author":"Goertz","year":"2012","journal-title":"Ultraschall Med"},{"key":"B10","doi-asserted-by":"publisher","first-page":"347","DOI":"10.1097\/rli.0000000000000136","article-title":"In Vivo abdominal Magnetic Resonance Elastography for the Assessment of Portal Hypertension before and after Transjugular Intrahepatic Portosystemic Shunt Implantation","volume":"50","author":"Guo","year":"2015","journal-title":"Investig. Radiol."},{"key":"B11","doi-asserted-by":"publisher","first-page":"1611","DOI":"10.1111\/jgh.14629","article-title":"Non\u2010invasive Structure-Function Assessment of the Liver by 2D Time\u2010harmonic Elastography and the Dynamic Liver MAximum Capacity (LiMAx) Test","volume":"34","author":"Heucke","year":"2019","journal-title":"J. Gastroenterology Hepatology"},{"key":"B12","doi-asserted-by":"publisher","first-page":"159","DOI":"10.3233\/ch-2010-1342","article-title":"Comparing Acoustic Radiation Force Impulse Imaging to Transient Elastography to Assess Liver Stiffness in Healthy Volunteers with and without Valsalva Manoeuvre","volume":"46","author":"Horster","year":"2010","journal-title":"Clin. Hemorheol. Microcirc."},{"key":"B13","doi-asserted-by":"publisher","first-page":"1305","DOI":"10.7863\/ultra.16.07046","article-title":"Physiologic Reduction of Hepatic Venous Blood Flow by the Valsalva Maneuver Decreases Liver Stiffness","volume":"36","author":"Ipek-Ugay","year":"2017","journal-title":"J. Ultrasound Med."},{"key":"B14","doi-asserted-by":"publisher","first-page":"1655","DOI":"10.1002\/mrm.28507","article-title":"Separation of Fluid and Solid Shear Wave Fields and Quantification of Coupling Density by Magnetic Resonance Poroelastography","volume":"85","author":"Lilaj","year":"2021","journal-title":"Magn. Reson. Med."},{"key":"B15","doi-asserted-by":"publisher","first-page":"39","DOI":"10.1016\/j.resp.2005.01.003","article-title":"The Valsalva Manoeuvre-Cardiovascular Effects and Performance Technique: a Critical Review","volume":"147","author":"Looga","year":"2005","journal-title":"Respir. Physiology Neurobiol."},{"key":"B16","doi-asserted-by":"publisher","first-page":"947","DOI":"10.1118\/1.4905048","article-title":"Suitability of Poroelastic and Viscoelastic Mechanical Models for High and Low Frequency MR Elastography","volume":"42","author":"Mcgarry","year":"2015","journal-title":"Med. Phys."},{"key":"B17","doi-asserted-by":"publisher","DOI":"10.1055\/s-0029-1191981","article-title":"Increased Venous Pressure Increases Liver Stiffness (Fibroscan) Independent of Liver Fibrosis","volume":"47","author":"Millonig","year":"2009","journal-title":"Z Gastroenterol."},{"key":"B18","doi-asserted-by":"publisher","DOI":"10.1097\/rli.0000000000000862","article-title":"Liquid-Liver Phantom","author":"Morr","year":"2022","journal-title":"Invest. Radiol."},{"key":"B19","doi-asserted-by":"publisher","DOI":"10.1088\/1361-6560\/abca00","article-title":"Elastography Imaging: the 30 Year Perspective","volume":"65","author":"Ormachea","year":"2020","journal-title":"Phys. Med. Biol."},{"key":"B20","doi-asserted-by":"publisher","first-page":"4443","DOI":"10.1088\/0031-9155\/59\/15\/4443","article-title":"A Microchannel Flow Model for Soft Tissue Elasticity","volume":"59","author":"Parker","year":"2014","journal-title":"Phys. Med. Biol."},{"key":"B21","doi-asserted-by":"publisher","first-page":"4227","DOI":"10.1088\/0031-9155\/60\/11\/4227","article-title":"Experimental Evaluations of the Microchannel Flow Model","volume":"60","author":"Parker","year":"2015","journal-title":"Phys. Med. Biol."},{"key":"B22","doi-asserted-by":"publisher","first-page":"1046","DOI":"10.1088\/1361-6560\/aa5201","article-title":"Reverberant Shear Wave Fields and Estimation of Tissue Properties","volume":"62","author":"Parker","year":"2017","journal-title":"Phys. Med. Biol."},{"key":"B23","doi-asserted-by":"publisher","first-page":"103","DOI":"10.1111\/apha.12639","article-title":"The Valsalva Manoeuvre: Physiology and Clinical Examples","volume":"217","author":"Pstras","year":"2016","journal-title":"Acta Physiol."},{"key":"B24","doi-asserted-by":"publisher","first-page":"425","DOI":"10.1055\/a-0838-9937","article-title":"The EFSUMB Guidelines and Recommendations for the Clinical Practice of Elastography in Non-hepatic Applications: Update 2018","volume":"40","author":"S\u0103ftoiu","year":"2019","journal-title":"Ultraschall Med"},{"key":"B25","doi-asserted-by":"publisher","first-page":"1987","DOI":"10.1148\/rg.2016160042","article-title":"Elastography in Chronic Liver Disease: Modalities, Techniques, Limitations, and Future Directions","volume":"36","author":"Srinivasa Babu","year":"2016","journal-title":"Radiographics"},{"key":"B26","doi-asserted-by":"publisher","first-page":"442","DOI":"10.1002\/jcu.22635","article-title":"Spleen and Liver Stiffness for Noninvasive Assessment of Portal Hypertension in Cirrhotic Patients with Large Esophageal Varices","volume":"46","author":"Tseng","year":"2018","journal-title":"J. Clin. Ultrasound"},{"key":"B27","doi-asserted-by":"publisher","first-page":"1641","DOI":"10.1088\/0031-9155\/59\/7\/1641","article-title":"In Vivotime-Harmonic Multifrequency Elastography of the Human Liver","volume":"59","author":"Tzsch\u00e4tzsch","year":"2014","journal-title":"Phys. Med. Biol."},{"key":"B28","doi-asserted-by":"publisher","first-page":"2562","DOI":"10.1016\/j.ultrasmedbio.2016.07.004","article-title":"Two-Dimensional Time-Harmonic Elastography of the Human Liver and Spleen","volume":"42","author":"Tzsch\u00e4tzsch","year":"2016","journal-title":"Ultrasound Med. Biol."},{"key":"B29","doi-asserted-by":"publisher","first-page":"595","DOI":"10.1016\/j.ultrasmedbio.2016.10.007","article-title":"Time-Harmonic Elastography of the Liver Is Sensitive to Intrahepatic Pressure Gradient and Liver Decompression after Transjugular Intrahepatic Portosystemic Shunt (TIPS) Implantation","volume":"43","author":"Tzsch\u00e4tzsch","year":"2017","journal-title":"Ultrasound Med. Biol."}],"container-title":["Frontiers in Bioengineering and Biotechnology"],"original-title":[],"link":[{"URL":"https:\/\/www.frontiersin.org\/articles\/10.3389\/fbioe.2022.886363\/full","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2022,6,1]],"date-time":"2022-06-01T05:11:31Z","timestamp":1654060291000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.frontiersin.org\/articles\/10.3389\/fbioe.2022.886363\/full"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2022,5,26]]},"references-count":29,"alternative-id":["10.3389\/fbioe.2022.886363"],"URL":"https:\/\/doi.org\/10.3389\/fbioe.2022.886363","relation":{},"ISSN":["2296-4185"],"issn-type":[{"value":"2296-4185","type":"electronic"}],"subject":[],"published":{"date-parts":[[2022,5,26]]},"article-number":"886363"}}