{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,9,2]],"date-time":"2025-09-02T10:59:53Z","timestamp":1756810793108,"version":"3.41.2"},"reference-count":68,"publisher":"Frontiers Media SA","license":[{"start":{"date-parts":[[2022,9,9]],"date-time":"2022-09-09T00:00:00Z","timestamp":1662681600000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"content-domain":{"domain":["frontiersin.org"],"crossmark-restriction":true},"short-container-title":["Front. Bioeng. Biotechnol."],"abstract":"<jats:p>Little research has been reported on evaluating the safety of the fixation construct in cervical kyphosis correction. In this study, we proposed a principal-strain criterion to evaluate the safety of the fixation construct and validated the modeling method against a retrospective case of anterior cervical discectomy fusion (ACDF). From C2 to T2 vertebra bodies, fixation instruments were reconstructed and positioned as per postoperative computed tomography (CT) scans. Head weight (HW) and various moments estimated from isometric strength data were imposed onto the C2. The postoperative stability of non-surgical segments, deformations surrounding the screw trajectories, and contact slipping on zygapophysial joints were analyzed. The model was validated against the reality that the patient had a good fusion and deformity correction. The ACDF restricted the range of motions (ROMs) of cervical segments and lent stability to vertebra fusion, no failure was found in the finite element (FE) model of cervical vertebrae. The deformation surrounding the screw trajectories were concentrated to the lateral sides of trajectories, recommending that the shape of the anterior cervical plate conforming to the curvature of the vertebra and screws fully inserted into vertebrae reduced the deformation concentration around the screw trajectories.<\/jats:p>","DOI":"10.3389\/fbioe.2022.950839","type":"journal-article","created":{"date-parts":[[2022,9,9]],"date-time":"2022-09-09T05:43:13Z","timestamp":1662702193000},"update-policy":"https:\/\/doi.org\/10.3389\/crossmark-policy","source":"Crossref","is-referenced-by-count":3,"title":["Patient-specific numerical investigation of the correction of cervical kyphotic deformity based on a retrospective clinical case"],"prefix":"10.3389","volume":"10","author":[{"given":"Tianchi","family":"Wu","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Hongyu","family":"Chen","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Yu","family":"Sun","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Tian","family":"Xia","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Feifei","family":"Zhou","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"William W.","family":"Lu","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"1965","published-online":{"date-parts":[[2022,9,9]]},"reference":[{"key":"B1","first-page":"287","article-title":"Segmentary antero-posterior mobility of the cervical spine","volume":"44","author":"Aho","year":"1955","journal-title":"Ann. Med. Intern. Fenn."},{"key":"B2","doi-asserted-by":"publisher","first-page":"1286","DOI":"10.1016\/j.jbiomech.2015.02.049","article-title":"Three-dimensional intervertebral kinematics in the healthy young adult cervical spine during dynamic functional loading","volume":"48","author":"Anderst","year":"2015","journal-title":"J. Biomech."},{"key":"B3","doi-asserted-by":"publisher","first-page":"659","DOI":"10.1016\/j.spinee.2011.05.007","article-title":"Cervical spine bone mineral density as a function of vertebral level and anatomic location","volume":"11","author":"Anderst","year":"2011","journal-title":"Spine J."},{"key":"B4","doi-asserted-by":"publisher","first-page":"32","DOI":"10.25259\/sni_46_2020","article-title":"The new onset of dysphagia four years after anterior cervical discectomy and fusion: Case report and literature review","volume":"11","author":"Ansari","year":"2020","journal-title":"Surg. Neurol. Int."},{"key":"B5","doi-asserted-by":"publisher","first-page":"161","DOI":"10.35860\/iarej.722229","article-title":"Toggling effect on pullout performance of pedicle screws: Review","volume":"4","author":"Aycan","year":"2020","journal-title":"Int. Adv. Res. Eng. J."},{"key":"B6","doi-asserted-by":"publisher","first-page":"675","DOI":"10.1001\/jamaoto.2014.787","article-title":"Progressive dysphagia in a patient with a history of cervical spine fusion","volume":"140","author":"Azadarmaki","year":"2014","journal-title":"JAMA Otolaryngol. Head. Neck Surg."},{"key":"B7","doi-asserted-by":"publisher","first-page":"633","DOI":"10.1016\/s0268-0033(00)00034-6","article-title":"Biomechanics of the cervical spine. I: Normal kinematics","volume":"15","author":"Bogduk","year":"2000","journal-title":"Clin. Biomech. (Bristol, Avon."},{"key":"B8","doi-asserted-by":"publisher","first-page":"322","DOI":"10.1002\/jor.1100160308","article-title":"Damage type and strain mode associations in human compact bone bending fatigue","volume":"16","author":"Boyce","year":"1998","journal-title":"J. Orthop. Res."},{"volume-title":"Netter\u2019s orthopaedic clinical examination: An evidence-based approach","year":"2015","author":"Cleland","key":"B9"},{"key":"B10","doi-asserted-by":"publisher","first-page":"416","DOI":"10.1097\/00002517-199810000-00009","article-title":"The spinal lax zone and neutral zone","volume":"11","author":"Crawford","year":"1998","journal-title":"J. Spinal Disord."},{"key":"B11","doi-asserted-by":"publisher","first-page":"e8826","DOI":"10.7759\/cureus.8826","article-title":"Kyphosis correction in patients undergoing a four-level anterior cervical discectomy and fusion","volume":"12","author":"Ebot","year":"2020","journal-title":"Cureus"},{"key":"B12","doi-asserted-by":"publisher","first-page":"100","DOI":"10.25259\/sni-191-2019","article-title":"A review of complication rates for anterior cervical diskectomy and fusion (ACDF)","volume":"10","author":"Epstein","year":"2019","journal-title":"Surg. Neurol. Int."},{"key":"B13","doi-asserted-by":"publisher","first-page":"1436","DOI":"10.1097\/01.brs.0000128759.02487.bf","article-title":"Patients with chronic neck pain demonstrate altered patterns of muscle activation during performance of a functional upper limb task","volume":"29","author":"Falla","year":"2004","journal-title":"Spine"},{"key":"B14","doi-asserted-by":"publisher","first-page":"468","DOI":"10.2106\/00004623-197052030-00006","article-title":"The effects of torsion on the lumbar intervertebral joints: The role of torsion in the production of disc degeneration","volume":"52","author":"Farfan","year":"1970","journal-title":"J. Bone Jt. Surg."},{"key":"B15","doi-asserted-by":"publisher","first-page":"6409","DOI":"10.3390\/ma14216409","article-title":"The correlation of regional microstructure and mechanics of the cervical articular process in adults","volume":"14","author":"Feng","year":"2021","journal-title":"Materials"},{"key":"B16","doi-asserted-by":"publisher","first-page":"117955061988113","DOI":"10.1177\/1179550619881131","article-title":"Late-Onset dysphagia from hardware migration after anterior cervical discectomy and fusion: An unusual cause and review of literature","volume":"12","author":"Fryer","year":"2019","journal-title":"Clin. Med. Insights. Ear Nose Throat"},{"key":"B17","doi-asserted-by":"publisher","first-page":"87","DOI":"10.1016\/b978-1-4377-0740-3.00005-2","article-title":"Interrelationship of the Spine, Rib Cage, and Shoulder","author":"Gray","year":"2012","journal-title":"Neurologic Considerations"},{"key":"B18","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1155\/2021\/3960553","article-title":"Anterior cervical discectomy and fusion using zero-P system for treatment of cervical spondylosis: A meta-analysis","volume":"2021","author":"Guo","year":"2021","journal-title":"Pain Res. Manag."},{"key":"B19","doi-asserted-by":"publisher","first-page":"28S","DOI":"10.1177\/2192568216687535","article-title":"Esophageal perforation following anterior cervical spine surgery: Case report and review of the literature","volume":"7","author":"Hershman","year":"2017","journal-title":"Glob. Spine J."},{"key":"B20","doi-asserted-by":"publisher","first-page":"1174","DOI":"10.1097\/00007632-199605150-00009","article-title":"Is the nucleus pulposus a solid or a fluid? Mechanical behaviors of the nucleus pulposus of the human intervertebral disc","volume":"21","author":"Iatridis","year":"1996","journal-title":"Spine"},{"key":"B21","doi-asserted-by":"publisher","first-page":"525","DOI":"10.1016\/j.jmpt.2008.08.003","article-title":"Clinical assessment of the deep cervical flexor muscles: The craniocervical flexion test","volume":"31","author":"Jull","year":"2008","journal-title":"J. Manip. Physiol. Ther."},{"volume-title":"Anatomy, head and neck, neck movements - StatPearls - NCBI","year":"2022","author":"Jung","key":"B22"},{"key":"B23","doi-asserted-by":"publisher","first-page":"1522","DOI":"10.1007\/s00586-012-2369-x","article-title":"Cervical range of motion and strength in 4, 293 young male adults with chronic neck pain","volume":"21","author":"Kauther","year":"2012","journal-title":"Eur. Spine J."},{"key":"B24","doi-asserted-by":"publisher","first-page":"125","DOI":"10.1016\/s0021-9290(97)00123-1","article-title":"Prediction of femoral fracture load using automated finite element modeling","volume":"31","author":"Keyak","year":"1997","journal-title":"J. Biomech."},{"key":"B25","doi-asserted-by":"publisher","first-page":"595","DOI":"10.1016\/j.medengphy.2010.02.009","article-title":"Influence of surgical treatment for disc degeneration disease at C5\u2013C6 on changes in some biomechanical parameters of the cervical spine","volume":"32","author":"Li","year":"2010","journal-title":"Med. Eng. Phys."},{"key":"B26","doi-asserted-by":"publisher","first-page":"932","DOI":"10.1016\/j.wneu.2017.07.079","article-title":"Finite element analysis of influence of axial position of center of rotation of a cervical total disc replacement on biomechanical parameters: Simulated 2-level replacement based on a validated model","volume":"106","author":"Li","year":"2017","journal-title":"World Neurosurg."},{"key":"B27","first-page":"692","article-title":"Normal range of motion of the cervical spine","volume":"70","author":"Lind","year":"1989","journal-title":"Arch. Phys. Med. Rehabil."},{"key":"B28","doi-asserted-by":"publisher","first-page":"24","DOI":"10.1016\/j.jot.2021.11.008","article-title":"Automatic phantom-less QCT system with high precision of BMD measurement for osteoporosis screening: Technique optimisation and clinical validation","volume":"33","author":"Liu","year":"2022","journal-title":"J. Orthop. Transl."},{"key":"B29","doi-asserted-by":"publisher","first-page":"2570","DOI":"10.1097\/00007632-199611150-00006","article-title":"Do bending, twisting, and diurnal fluid changes in the disc affect the propensity to prolapse? A viscoelastic finite element model","volume":"21","author":"Lu","year":"1996","journal-title":"Spine"},{"key":"B30","doi-asserted-by":"publisher","first-page":"619","DOI":"10.1097\/00007632-199904010-00002","article-title":"The ligaments and anulus fibrosus of human adult cervical intervertebral discs","volume":"24","author":"Mercer","year":"1999","journal-title":"Spine"},{"key":"B31","doi-asserted-by":"publisher","first-page":"769","DOI":"10.1016\/0021-9290(88)90285-0","article-title":"Load-displacement properties of lower cervical spine motion segments","volume":"21","author":"Moroney","year":"1988","journal-title":"J. Biomech."},{"key":"B32","doi-asserted-by":"publisher","first-page":"1","DOI":"10.3109\/ort.1960.31.suppl-43.01","article-title":"Lumbar intradiscal pressure: Experimental studies on post-mortem material","volume":"31","author":"Nachemson","year":"2014","journal-title":"Acta Orthop. Scand."},{"key":"B33","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1155\/2015\/173687","article-title":"Delayed presentation of pharyngeal erosion after anterior cervical discectomy and fusion","volume":"2015","author":"Nathani","year":"2015","journal-title":"Case Rep. Orthop."},{"key":"B34","doi-asserted-by":"publisher","first-page":"201","DOI":"10.1097\/00002517-200106000-00003","article-title":"Nonlinear finite-element analysis of the lower cervical spine (C4\u2013C6) under axial loading","volume":"14","author":"Ng","year":"2001","journal-title":"J. Spinal Disord."},{"key":"B35","doi-asserted-by":"publisher","first-page":"649","DOI":"10.1007\/s00264-007-0369-y","article-title":"Anterior cervical locking plate-related complications; prevention and treatment recommendations","volume":"32","author":"Ning","year":"2008","journal-title":"Int. Orthop."},{"key":"B36","doi-asserted-by":"publisher","first-page":"385","DOI":"10.1097\/bsd.0b013e318180e672","article-title":"Cervical kyphotic deformity correction using 360-degree reconstruction","volume":"22","author":"Nottmeier","year":"2009","journal-title":"J. Spinal Disord. Tech."},{"key":"B37","doi-asserted-by":"publisher","first-page":"411","DOI":"10.1097\/00002517-199112000-00002","article-title":"Three-Dimensional translational movements of the upper cervical spine","volume":"4","author":"Oda","year":"1991","journal-title":"J. Spinal Disord."},{"key":"B38","doi-asserted-by":"publisher","first-page":"419","DOI":"10.1016\/s0278-5919(20)30404-x","article-title":"Biochemistry of the intervertebral disc","volume":"12","author":"Oegema","year":"1993","journal-title":"Clin. Sports Med."},{"key":"B39","doi-asserted-by":"publisher","first-page":"e919270","DOI":"10.12659\/msm.919270","article-title":"Biomechanical comparison of 1-level corpectomy and 2-level discectomy for cervical spondylotic myelopathy: A finite element analysis","volume":"26","author":"Ouyang","year":"2020","journal-title":"Med. Sci. Monit."},{"key":"B40","doi-asserted-by":"publisher","first-page":"1489","DOI":"10.12659\/msm.913630","article-title":"Biomechanical comparison of integrated fixation cage versus anterior cervical plate and cage in anterior cervical corpectomy and fusion (accf): A finite element analysis","volume":"25","author":"Ouyang","year":"2019","journal-title":"Med. Sci. Monit."},{"key":"B41","doi-asserted-by":"publisher","first-page":"157","DOI":"10.1097\/00002517-199106000-00005","article-title":"Flexion, extension, and lateral bending of the upper cervical spine in response to alar ligament transections","volume":"4","author":"Panjabi","year":"1991","journal-title":"J. Spinal Disord."},{"key":"B42","doi-asserted-by":"publisher","first-page":"2692","DOI":"10.1097\/00007632-200112150-00012","article-title":"Mechanical properties of the human cervical spine as shown by three-dimensional load\u2013displacement curves","volume":"26","author":"Panjabi","year":"2001","journal-title":"Spine"},{"key":"B43","doi-asserted-by":"publisher","first-page":"2642","DOI":"10.1097\/00007632-199412000-00008","article-title":"On the understanding of clinical instability","volume":"19","author":"Panjabi","year":"1994","journal-title":"Spine"},{"key":"B44","doi-asserted-by":"publisher","first-page":"398","DOI":"10.1097\/bsd.0000000000000844","article-title":"How does screw migration or fracture after anterior cervical plate fixation affect the radiographic and clinical outcomes?","volume":"32","author":"Park","year":"2019","journal-title":"Clin. Spine Surg."},{"key":"B45","doi-asserted-by":"publisher","first-page":"1","DOI":"10.3109\/ort.1957.28.suppl-25.01","article-title":"Fracture of the vertebral end-plate in the lumbar spine: An experimental biomechanical investigation","volume":"28","author":"Perey","year":"2014","journal-title":"Acta Orthop. Scand."},{"key":"B46","doi-asserted-by":"publisher","first-page":"175","DOI":"10.1007\/bf02427846","article-title":"Comparison of the structure of human intervertebral discs in the cervical, thoracic and lumbar regions of the spine","volume":"8","author":"Pooni","year":"1986","journal-title":"Surg. Radiol. Anat."},{"key":"B47","doi-asserted-by":"publisher","first-page":"337","DOI":"10.1007\/s00414-006-0111-0","article-title":"Cervical spine segmental vertebral motion in healthy volunteers feigning restriction of neck flexion and extension","volume":"121","author":"Puglisi","year":"2007","journal-title":"Int. J. Leg. Med."},{"key":"B48","first-page":"166","article-title":"Estimation of mass moment of inertia of human body, when bending forward, for the design of A self-transfer robotic facility","volume":"11","author":"Ramachandran","year":"2016","journal-title":"J. Eng. Sci. Technol."},{"key":"B49","doi-asserted-by":"publisher","first-page":"379","DOI":"10.1136\/bjsm.2007.040709","article-title":"Cervical muscle strength measurement is dependent on the location of thoracic support","volume":"42","author":"Rezasoltani","year":"2008","journal-title":"Br. J. Sports Med."},{"key":"B50","doi-asserted-by":"publisher","first-page":"89","DOI":"10.1359\/jbmr.1997.12.1.89","article-title":"The thickness of human vertebral cortical bone and its changes in aging and osteoporosis: A histomorphometric analysis of the complete spinal column from thirty-seven autopsy specimens","volume":"12","author":"Ritzel","year":"1997","journal-title":"J. Bone Min. Res."},{"volume-title":"Surgery of the skin","year":"2005","author":"Robinson","key":"B51"},{"key":"B52","doi-asserted-by":"publisher","first-page":"1683","DOI":"10.1007\/s00264-008-0687-8","article-title":"Minimally invasive versus open transforaminal lumbar interbody fusion: Evaluating initial experience","volume":"33","author":"Schizas","year":"2009","journal-title":"Int. Orthop."},{"key":"B53","doi-asserted-by":"publisher","first-page":"360","DOI":"10.1016\/j.math.2013.05.009","article-title":"Function and structure of the deep cervical extensor muscles in patients with neck pain","volume":"18","author":"Schomacher","year":"2013","journal-title":"Man. Ther."},{"key":"B54","doi-asserted-by":"publisher","first-page":"120","DOI":"10.1097\/00007632-198403000-00003","article-title":"Stress analysis of the lumbar disc-body unit in compression A three-dimensional nonlinear finite element study","volume":"9","author":"Shirazi-Adl","year":"1984","journal-title":"Spine"},{"key":"B55","doi-asserted-by":"publisher","first-page":"e0151680","DOI":"10.1371\/journal.pone.0151680","article-title":"The effectiveness of percutaneous vertebroplasty is determined by the patient-specific bone condition and the treatment strategy","volume":"11","author":"Soyka","year":"2016","journal-title":"Plos One"},{"key":"B56","doi-asserted-by":"publisher","first-page":"662","DOI":"10.1227\/neu.0b013e31826100c9","article-title":"The impact of standing regional cervical sagittal alignment on outcomes in posterior cervical fusion surgery","volume":"71","author":"Tang","year":"2012","journal-title":"Neurosurgery"},{"key":"B57","doi-asserted-by":"crossref","DOI":"10.26481\/dis.19880616hm","volume-title":"Motion patterns in the cervical spine","author":"Van Mameren","year":"1988"},{"key":"B58","doi-asserted-by":"publisher","first-page":"695","DOI":"10.1016\/j.spinee.2013.08.032","article-title":"Comparative analysis of international standards for the fatigue testing of posterior spinal fixation systems","volume":"14","author":"Villa","year":"2014","journal-title":"Spine J."},{"key":"B59","doi-asserted-by":"publisher","first-page":"375","DOI":"10.1016\/j.jbiomech.2004.11.014","article-title":"Experimental flexion\/extension data corridors for validation of finite element models of the young, normal cervical spine","volume":"39","author":"Wheeldon","year":"2006","journal-title":"J. Biomech."},{"key":"B60","doi-asserted-by":"publisher","first-page":"148","DOI":"10.1007\/s005860050045","article-title":"Testing criteria for spinal implants: Recommendations for the standardization of in vitro stability testing of spinal implants","volume":"7","author":"Wilke","year":"1998","journal-title":"Eur. Spine J."},{"key":"B61","doi-asserted-by":"publisher","first-page":"504","DOI":"10.1115\/1.1504098","article-title":"Importance of nonlinear and multivariable flexibility coefficients in the prediction of human cervical spine motion","volume":"124","author":"Winkelstein","year":"2002","journal-title":"J. Biomech. Eng."},{"key":"B62","doi-asserted-by":"publisher","first-page":"139","DOI":"10.4271\/2000-01-sc11","article-title":"Experimental and computational characterization of three-dimensional cervical spine flexibility","volume":"44","author":"Winkelstein","year":"2000","journal-title":"Stapp Car Crash J."},{"key":"B63","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1155\/2015\/749463","article-title":"Recurrent laryngeal edema imitating angioedema caused by dislocated screw after anterior spine surgery","volume":"2015","author":"W\u00f3jtowicz","year":"2015","journal-title":"Case Rep. Otolaryngol."},{"key":"B64","doi-asserted-by":"publisher","first-page":"32","DOI":"10.1016\/j.jot.2018.12.002","article-title":"Normal intervertebral segment rotation of the subaxial cervical spine: An invivo study of dynamic neck motions","volume":"18","author":"Yu","year":"2019","journal-title":"J. Orthop. Transl."},{"key":"B65","doi-asserted-by":"publisher","first-page":"189","DOI":"10.1016\/j.jbiomech.2004.10.029","article-title":"Finite element analysis of moment-rotation relationships for human cervical spine","volume":"39","author":"Zhang","year":"2006","journal-title":"J. Biomech."},{"key":"B66","doi-asserted-by":"publisher","first-page":"109418","DOI":"10.1016\/j.jbiomech.2019.109418","article-title":"Intervertebral range of motion characteristics of normal cervical spinal segments (C0-T1) during in vivo neck motions","volume":"98","author":"Zhou","year":"2020","journal-title":"J. Biomech."},{"key":"B67","doi-asserted-by":"publisher","first-page":"105547","DOI":"10.1016\/j.clinbiomech.2021.105547","article-title":"The effects of titanium mesh cage size on the biomechanical responses of cervical spine after anterior cervical corpectomy and fusion: A finite element study","volume":"91","author":"Zhou","year":"2022","journal-title":"Clin. Biomech. (Bristol, Avon."},{"key":"B68","doi-asserted-by":"publisher","first-page":"2932","DOI":"10.1016\/j.jbiomech.2008.07.025","article-title":"Microcracking damage and the fracture process in relation to strain rate in human cortical bone tensile failure","volume":"41","author":"Zioupos","year":"2008","journal-title":"J. Biomech."}],"container-title":["Frontiers in Bioengineering and Biotechnology"],"original-title":[],"link":[{"URL":"https:\/\/www.frontiersin.org\/articles\/10.3389\/fbioe.2022.950839\/full","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2022,9,9]],"date-time":"2022-09-09T05:43:27Z","timestamp":1662702207000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.frontiersin.org\/articles\/10.3389\/fbioe.2022.950839\/full"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2022,9,9]]},"references-count":68,"alternative-id":["10.3389\/fbioe.2022.950839"],"URL":"https:\/\/doi.org\/10.3389\/fbioe.2022.950839","relation":{},"ISSN":["2296-4185"],"issn-type":[{"type":"electronic","value":"2296-4185"}],"subject":[],"published":{"date-parts":[[2022,9,9]]},"article-number":"950839"}}