{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,11,4]],"date-time":"2026-11-04T23:28:01Z","timestamp":1793834881161,"version":"4.6.1"},"reference-count":76,"publisher":"Frontiers Media SA","license":[{"start":{"date-parts":[[2022,9,8]],"date-time":"2022-09-08T00:00:00Z","timestamp":1662595200000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"content-domain":{"domain":["frontiersin.org"],"crossmark-restriction":true},"short-container-title":["Front. Bioeng. Biotechnol."],"abstract":"<jats:p><jats:bold>Background and objective:<\/jats:bold> The osteoporotic vertebral compression fracture (OVCF) has an incidence of 7.8\/1000 person-years at 55\u201365\u00a0years. At 75\u00a0years or older, the incidence increases to 19.6\/1000 person-years in females and 5.2\u20139.3\/1000 person-years in males. To solve this problem, percutaneous vertebroplasty (PVP) was developed in recent years and has been widely used in clinical practice to treat OVCF. Are the clinical effects of unilateral percutaneous vertebroplasty (UPVP) and bilateral percutaneous vertebroplasty (BPVP) the same? The purpose of this study was to compare biomechanical differences between UPVP and BPVP using finite element analysis.<\/jats:p><jats:p><jats:bold>Materials and methods:<\/jats:bold> The heterogeneous assignment finite element (FE) model of T11-L1 was constructed and validated. A compression fracture of the vertebral body was performed at T12. UPVP and BPVP were simulated by the difference in the distribution of bone cement in T12. Stress distributions and maximum von Mises stresses of vertebrae and intervertebral discs were compared. The rate of change of maximum displacement between UPVP and BPVP was evaluated.<\/jats:p><jats:p><jats:bold>Results:<\/jats:bold> There were no obvious high-stress concentration regions on the anterior and middle columns of the T12 vertebral body in BPVP. Compared with UPVP, the maximum stress on T11 in BPVP was lower under left\/right lateral bending, and the maximum stress on L1 was lower under all loading conditions. For the T12-L1 intervertebral disc, the maximum stress of BPVP was less than that of UPVP. The maximum displacement of T12 after BPVP was less than that after UPVP under the six loading conditions.<\/jats:p><jats:p><jats:bold>Conclusion:<\/jats:bold> BPVP could balance the stress of the vertebral body, reduce the maximum stress of the intervertebral disc, and offer advantages in terms of stability compared with UPVP. In summary, BPVP could reduce the incidence of postoperative complications and provide promising clinical effects for patients.<\/jats:p>","DOI":"10.3389\/fbioe.2022.978917","type":"journal-article","created":{"date-parts":[[2022,9,8]],"date-time":"2022-09-08T13:50:23Z","timestamp":1662645023000},"update-policy":"https:\/\/doi.org\/10.3389\/crossmark-policy","source":"Crossref","is-referenced-by-count":41,"title":["Biomechanical comparison between unilateral and bilateral percutaneous vertebroplasty for osteoporotic vertebral compression fractures: A finite element analysis"],"prefix":"10.3389","volume":"10","author":[{"given":"Haowen","family":"Dai","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Yang","family":"Liu","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Qing","family":"Han","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Aobo","family":"Zhang","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Hao","family":"Chen","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Yang","family":"Qu","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Jincheng","family":"Wang","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Jianwu","family":"Zhao","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"1965","published-online":{"date-parts":[[2022,9,8]]},"reference":[{"key":"B1","doi-asserted-by":"publisher","first-page":"294","DOI":"10.4103\/0256-4947.81542","article-title":"Percutaneous vertebroplasty complications","volume":"31","author":"Al-Nakshabandi","year":"2011","journal-title":"Ann. Saudi Med."},{"key":"B2","doi-asserted-by":"publisher","first-page":"185","DOI":"10.1016\/j.jot.2015.09.003","article-title":"Computational modelling of bone augmentation in the spine","volume":"3","author":"Badilatti","year":"2015","journal-title":"J. Orthop. Transl."},{"key":"B3","doi-asserted-by":"publisher","first-page":"421","DOI":"10.1007\/s00586-002-0512-9","article-title":"Load shift of the intervertebral disc after a vertebroplasty: A finite-element study","volume":"12","author":"Baroud","year":"2003","journal-title":"Eur. spine J."},{"key":"B4","doi-asserted-by":"publisher","first-page":"1061","DOI":"10.1097\/00007632-200005010-00004","article-title":"Biomechanical evaluation of a new bone cement for use in vertebroplasty","volume":"25","author":"Belkoff","year":"2000","journal-title":"Spine"},{"key":"B5","doi-asserted-by":"publisher","first-page":"1537","DOI":"10.1097\/00007632-200107150-00007","article-title":"The biomechanics of vertebroplasty - the effect of cement volume on mechanical behavior","volume":"26","author":"Belkoff","year":"2001","journal-title":"Spine"},{"key":"B6","doi-asserted-by":"publisher","first-page":"749914","DOI":"10.3389\/fbioe.2021.749914","article-title":"Stability evaluation of different oblique lumbar interbody fusion constructs in normal and osteoporotic condition - a finite element based study","volume":"9","author":"Bereczki","year":"2021","journal-title":"Front. Bioeng. Biotechnol."},{"key":"B7","doi-asserted-by":"publisher","first-page":"CD006349","DOI":"10.1002\/14651858.CD006349.pub4","article-title":"Percutaneous vertebroplasty for osteoporotic vertebral compression fracture","volume":"11","author":"Buchbinder","year":"2018","journal-title":"Cochrane Database Syst. Rev."},{"key":"B8","doi-asserted-by":"publisher","first-page":"1272","DOI":"10.1007\/s00586-011-1744-3","article-title":"Comparison of unipedicular and bipedicular kyphoplasty on the stiffness and biomechanical balance of compression fractured vertebrae","volume":"20","author":"Chen","year":"","journal-title":"Eur. spine J."},{"key":"B9","doi-asserted-by":"publisher","first-page":"927","DOI":"10.1007\/s00402-010-1236-7","article-title":"Repeated percutaneous vertebroplasty for refracture of cemented vertebrae","volume":"131","author":"Chen","year":"","journal-title":"Arch. Orthop. Trauma Surg."},{"key":"B10","doi-asserted-by":"publisher","first-page":"3439","DOI":"10.1007\/s00586-016-4395-6","article-title":"Comparison of unilateral versus bilateral percutaneous kyphoplasty for the treatment of patients with osteoporosis vertebral compression fracture (OVCF): A systematic review and meta-analysis","volume":"25","author":"Cheng","year":"2016","journal-title":"Eur. spine J."},{"key":"B11","doi-asserted-by":"publisher","first-page":"356","DOI":"10.1097\/BRS.0b013e31819481b1","article-title":"Prophylactic vertebroplasty may reduce the risk of adjacent intact vertebra from fatigue injury: An ex vivo biomechanical study","volume":"34","author":"Chiang","year":"2009","journal-title":"Spine"},{"key":"B12","doi-asserted-by":"publisher","first-page":"342","DOI":"10.1093\/neuros\/nyaa435","article-title":"A retrospective analysis in 1347 patients undergoing cement augmentation for osteoporotic vertebral compression fracture: Is the sandwich vertebra at a higher risk of further fracture?","volume":"88","author":"Chiu","year":"2021","journal-title":"Neurosurgery"},{"key":"B13","doi-asserted-by":"publisher","first-page":"313","DOI":"10.1136\/neurintsurg-2018-014231","article-title":"Vertebral body stent augmentation to reconstruct the anterior column in neoplastic extreme osteolysis","volume":"11","author":"Cianfoni","year":"","journal-title":"J. Neurointerv. Surg."},{"key":"B14","doi-asserted-by":"publisher","first-page":"507","DOI":"10.3171\/2019.9.Spine19711","article-title":"Stent screw-assisted internal fixation (SAIF): Clinical report of a novel approach to stabilizing and internally fixating vertebrae destroyed by malignancy","volume":"32","author":"Cianfoni","year":"","journal-title":"J. Neurosurg. Spine"},{"key":"B15","doi-asserted-by":"publisher","first-page":"525","DOI":"10.1148\/radiology.200.2.8685351","article-title":"Percutaneous vertebroplasty for osteolytic metastases and myeloma: Effects of the percentage of lesion filling and the leakage of methyl methacrylate at clinical follow-up","volume":"200","author":"Cotten","year":"1996","journal-title":"Radiology"},{"key":"B16","doi-asserted-by":"publisher","first-page":"65","DOI":"10.1097\/00003086-198410000-00008","article-title":"Spinal instability as defined by the three-column spine concept in acute spinal trauma","volume":"189","author":"Denis","year":"1984","journal-title":"Clin. Orthop. Relat. Res."},{"key":"B17","doi-asserted-by":"publisher","first-page":"817","DOI":"10.1097\/00007632-198311000-00003","article-title":"The three column spine and its significance in the classification of acute thoracolumbar spinal injuries","volume":"8","author":"Denis","year":"1983","journal-title":"Spine"},{"key":"B18","doi-asserted-by":"publisher","first-page":"63","DOI":"10.1136\/neurintsurg-2020-016597","article-title":"The 'armed concrete' approach: Stent-screw-assisted internal fixation (SAIF) reconstructs and internally fixates the most severe osteoporotic vertebral fractures","volume":"13","author":"Distefano","year":"2021","journal-title":"J. Neurointerv. Surg."},{"key":"B19","doi-asserted-by":"publisher","first-page":"1412","DOI":"10.1080\/10255842.2017.1366995","article-title":"Effectiveness of pedicle screw inclusion at the fracture level in short-segment fixation constructs for the treatment of thoracolumbar burst fractures: A computational biomechanics analysis","volume":"20","author":"Elmasry","year":"2017","journal-title":"Comput. methods biomechanics Biomed. Eng."},{"key":"B20","doi-asserted-by":"publisher","first-page":"9174","DOI":"10.1115\/1.4039174","article-title":"Finite element study to evaluate the biomechanical performance of the spine after augmenting percutaneous pedicle screw fixation with kyphoplasty in the treatment of burst fractures","volume":"140","author":"Elmasry","year":"2018","journal-title":"J. Biomech. Eng."},{"key":"B21","doi-asserted-by":"publisher","first-page":"733","DOI":"10.1227\/NEU.0b013e31821cc499","article-title":"Premature adjacent vertebral fracture after vertebroplasty: A biomechanical study","volume":"69","author":"Fahim","year":"2011","journal-title":"Neurosurgery"},{"key":"B22","doi-asserted-by":"publisher","first-page":"E1195","DOI":"10.1097\/brs.0000000000002666","article-title":"Vertebral augmentation can induce early signs of degeneration in the adjacent intervertebral disc: Evidence from a rabbit model","volume":"43","author":"Feng","year":"2018","journal-title":"Spine"},{"key":"B23","doi-asserted-by":"publisher","first-page":"1384","DOI":"10.21037\/atm-20-2246","article-title":"Selective cement augmentation of cranial and caudal pedicle screws provides comparable stability to augmentation on all segments in the osteoporotic spine: A finite element analysis","volume":"8","author":"Guo","year":"","journal-title":"Ann. Transl. Med."},{"key":"B24","doi-asserted-by":"publisher","first-page":"460","DOI":"10.1186\/s12891-020-03498-6","article-title":"Influence of cement-augmented pedicle screws with different volumes of polymethylmethacrylate in osteoporotic lumbar vertebrae over the adjacent segments: A 3D finite element analysis","volume":"21","author":"Guo","year":"","journal-title":"BMC Musculoskelet. Disord."},{"key":"B25","doi-asserted-by":"publisher","first-page":"460","DOI":"10.1186\/s12891-020-03498-6","article-title":"Influence of cement-augmented pedicle screws with different volumes of polymethylmethacrylate in osteoporotic lumbar vertebrae over the adjacent segments: A 3D finite element analysis","volume":"21","author":"Guo","year":"","journal-title":"BMC Musculoskelet. Disord."},{"key":"B26","doi-asserted-by":"publisher","first-page":"E143","DOI":"10.1097\/brs.0000000000002247","article-title":"Dynamic response of the lumbar spine to whole-body vibration under a compressive follower preload","volume":"43","author":"Guo","year":"2018","journal-title":"Spine"},{"key":"B27","doi-asserted-by":"publisher","first-page":"105023","DOI":"10.1016\/j.clinbiomech.2020.105023","article-title":"Comparison of effects of four interbody fusion approaches on the fused and adjacent segments under vibration","volume":"76","author":"Guo","year":"2020","journal-title":"Clin. Biomech. (Bristol, Avon)"},{"key":"B28","doi-asserted-by":"publisher","first-page":"683","DOI":"10.1136\/neurintsurg-2021-017612","article-title":"Spine 2.0 JNIS style","volume":"13","author":"Hirsch","year":"2021","journal-title":"J. Neurointerv. Surg."},{"key":"B29","doi-asserted-by":"publisher","first-page":"e0198407","DOI":"10.1371\/journal.pone.0198407","article-title":"Polymethylmethacrylate distribution is associated with recompression after vertebroplasty or kyphoplasty for osteoporotic vertebral compression fractures: A retrospective study","volume":"13","author":"Hou","year":"2018","journal-title":"PloS one"},{"key":"B30","doi-asserted-by":"publisher","first-page":"2833","DOI":"10.1007\/s11999-014-3745-0","article-title":"Is unilateral kyphoplasty as effective and safe as bilateral kyphoplasties for osteoporotic vertebral compression fractures? A meta-analysis","volume":"472","author":"Huang","year":"2014","journal-title":"Clin. Orthop. Relat. Res."},{"key":"B31","doi-asserted-by":"publisher","first-page":"125","DOI":"10.3340\/jkns.2010.48.2.125","article-title":"The proper volume and distribution of cement augmentation on percutaneous vertebroplasty","volume":"48","author":"Kim","year":"2010","journal-title":"J. Korean Neurosurg. Soc."},{"key":"B32","doi-asserted-by":"publisher","first-page":"435","DOI":"10.3340\/jkns.2012.52.5.435","article-title":"Effect of bone cement volume and stiffness on occurrences of adjacent vertebral fractures after vertebroplasty","volume":"52","author":"Kim","year":"2012","journal-title":"J. Korean Neurosurg. Soc."},{"key":"B33","doi-asserted-by":"publisher","first-page":"53","DOI":"10.1016\/j.clinbiomech.2016.03.008","article-title":"In silico investigation of vertebroplasty as a stand-alone treatment for vertebral burst fractures","volume":"34","author":"Koh","year":"2016","journal-title":"Clin. Biomech. (Bristol, Avon)"},{"key":"B34","doi-asserted-by":"publisher","first-page":"2281","DOI":"10.1016\/j.spinee.2014.01.028","article-title":"Comparison of radiological and clinical results of balloon kyphoplasty according to anterior height loss in the osteoporotic vertebral fracture","volume":"14","author":"Lee","year":"2014","journal-title":"Spine J."},{"key":"B35","doi-asserted-by":"publisher","first-page":"775","DOI":"10.1007\/s00590-012-1076-y","article-title":"Treatment of thoracolumbar fracture with pedicle screws at injury level: A biomechanical study based on three-dimensional finite element analysis","volume":"23","author":"Li","year":"","journal-title":"Eur. J. Orthop. Surg. Traumatol."},{"key":"B36","doi-asserted-by":"publisher","first-page":"775","DOI":"10.1007\/s00590-012-1076-y","article-title":"Treatment of thoracolumbar fracture with pedicle screws at injury level: A biomechanical study based on three-dimensional finite element analysis","volume":"23","author":"Li","year":"","journal-title":"Eur. J. Orthop. Surg. Traumatol."},{"key":"B37","doi-asserted-by":"publisher","first-page":"246","DOI":"10.1016\/j.jss.2014.12.053","article-title":"Biomechanical effects of cement distribution in the fractured area on osteoporotic vertebral compression fractures: A three-dimensional finite element analysis","volume":"195","author":"Liang","year":"","journal-title":"J. Surg. Res."},{"key":"B38","doi-asserted-by":"publisher","first-page":"246","DOI":"10.1016\/j.jss.2014.12.053","article-title":"Biomechanical effects of cement distribution in the fractured area on osteoporotic vertebral compression fractures: A three-dimensional finite element analysis","volume":"195","author":"Liang","year":"","journal-title":"J. Surg. Res."},{"key":"B39","doi-asserted-by":"publisher","first-page":"e643","DOI":"10.1016\/j.wneu.2020.04.056","article-title":"Impact of osteoporosis on different type of short-segment posterior instrumentation for thoracolumbar burst fracture-A finite element analysis","volume":"139","author":"Liao","year":"2020","journal-title":"World Neurosurg."},{"key":"B40","doi-asserted-by":"publisher","first-page":"1547","DOI":"10.1097\/00007632-200107150-00009","article-title":"Effects of bone cement volume and distribution on vertebral stiffness after vertebroplasty","volume":"26","author":"Liebschner","year":"","journal-title":"Spine"},{"key":"B41","doi-asserted-by":"publisher","first-page":"1547","DOI":"10.1097\/00007632-200107150-00009","article-title":"Effects of bone cement volume and distribution on vertebral stiffness after vertebroplasty","volume":"26","author":"Liebschner","year":"","journal-title":"Spine"},{"key":"B42","doi-asserted-by":"publisher","first-page":"1017","DOI":"10.2147\/cia.S54613","article-title":"Epidemiology and management of osteoporosis in the people's republic of China: Current perspectives.","volume":"10","author":"Lin","year":"2015","journal-title":"Clin. Interv. Aging"},{"key":"B43","doi-asserted-by":"publisher","first-page":"104006","DOI":"10.1016\/j.compbiomed.2020.104006","article-title":"Biomechanical comparison between metal block and cement-screw techniques for the treatment of tibial bone defects in total knee arthroplasty based on finite element analysis","volume":"125","author":"Liu","year":"2020","journal-title":"Comput. Biol. Med."},{"key":"B44","doi-asserted-by":"publisher","first-page":"851","DOI":"10.1007\/s00198-021-06232-7","article-title":"A nomogram for short-term recurrent pain after percutaneous vertebroplasty for osteoporotic vertebral compression fractures","volume":"33","author":"Liu","year":"2021","journal-title":"Osteoporos. Int."},{"key":"B45","doi-asserted-by":"publisher","first-page":"1439","DOI":"10.1097\/TA.0b013e318169cd0b","article-title":"New vertebral fracture after vertebroplasty","volume":"65","author":"Lo","year":"2008","journal-title":"J. Trauma-Injury Infect. Crit. Care"},{"key":"B46","first-page":"1606","article-title":"Establishment and validation of a T12-L2 3D finite element model for thoracolumbar segments","volume":"14","author":"Lu","year":"2022","journal-title":"Am. J. Transl. Res."},{"key":"B47","doi-asserted-by":"publisher","first-page":"1549","DOI":"10.1097\/00007632-200307150-00014","article-title":"The effect of vertebral body percentage fill on mechanical behavior during percutaneous vertebroplasty","volume":"28","author":"Molloy","year":"2003","journal-title":"Spine"},{"key":"B48","doi-asserted-by":"publisher","first-page":"1872","DOI":"10.1016\/j.spinee.2013.06.007","article-title":"Vertebroplasty increases compression of adjacent IVDs and vertebrae in osteoporotic spines","volume":"13","author":"Nagaraja","year":"2013","journal-title":"Spine J."},{"key":"B49","doi-asserted-by":"publisher","first-page":"933341","DOI":"10.3389\/fbioe.2022.933341","article-title":"Kinematic and biomechanical responses of the spine to distraction surgery in children with early onset scoliosis: A 3-D finite element analysis","volume":"10","author":"Pei","year":"2022","journal-title":"Front. Bioeng. Biotechnol."},{"key":"B50","doi-asserted-by":"publisher","first-page":"2137","DOI":"10.1007\/s11517-018-1844-x","article-title":"Optimizing bone cement stiffness for vertebroplasty through biomechanical effects analysis based on patient-specific three-dimensional finite element modeling","volume":"56","author":"Peng","year":"2018","journal-title":"Med. Biol. Eng. Comput."},{"key":"B51","doi-asserted-by":"publisher","first-page":"413","DOI":"10.1007\/s00586-002-0505-8","article-title":"Factors influencing stresses in the lumbar spine after the insertion of intervertebral cages: Finite element analysis","volume":"12","author":"Polikeit","year":"","journal-title":"Eur. Spine J."},{"key":"B52","doi-asserted-by":"publisher","first-page":"413","DOI":"10.1007\/s00586-002-0505-8","article-title":"Factors influencing stresses in the lumbar spine after the insertion of intervertebral cages: Finite element analysis","volume":"12","author":"Polikeit","year":"","journal-title":"Eur. spine J."},{"key":"B53","doi-asserted-by":"publisher","first-page":"991","DOI":"10.1097\/01.Brs.0000061987.71624.17","article-title":"The effect of cement augmentation on the load transfer in an osteoporotic functional spinal unit: Finite-element analysis","volume":"28","author":"Polikeit","year":"","journal-title":"Spine"},{"key":"B54","doi-asserted-by":"publisher","first-page":"991","DOI":"10.1097\/01.BRS.0000061987.71624.17","article-title":"The effect of cement augmentation on the load transfer in an osteoporotic functional spinal unit - finite-element analysis","volume":"28","author":"Polikeit","year":"","journal-title":"Spine"},{"key":"B55","doi-asserted-by":"publisher","first-page":"347","DOI":"10.1016\/1350-4533(95)97314-f","article-title":"Relations of mechanical properties to density and CT numbers in human bone","volume":"17","author":"Rho","year":"1995","journal-title":"Med. Eng. Phys."},{"key":"B56","doi-asserted-by":"publisher","first-page":"38","DOI":"10.1186\/s12891-018-1953-6","article-title":"Biomechanical effects of metastasis in the osteoporotic lumbar spine: A finite element analysis","volume":"19","author":"Salvatore","year":"2018","journal-title":"BMC Musculoskelet. Disord."},{"key":"B57","doi-asserted-by":"publisher","first-page":"150","DOI":"10.1016\/j.spinee.2020.07.016","article-title":"Biomechanical effects of laminectomies in the human lumbar spine: A finite element study","volume":"21","author":"Spina","year":"2021","journal-title":"Spine J."},{"key":"B58","doi-asserted-by":"publisher","first-page":"156","DOI":"10.1186\/s13018-016-0479-6","article-title":"Comparison of unilateral and bilateral percutaneous vertebroplasty for osteoporotic vertebral compression fractures: A systematic review and meta-analysis","volume":"11","author":"Sun","year":"2016","journal-title":"J. Orthop. Surg. Res."},{"key":"B59","doi-asserted-by":"publisher","first-page":"357","DOI":"10.1016\/j.jcma.2011.06.008","article-title":"Risk of post-vertebroplasty fracture in adjacent vertebral bodies appears correlated with the morphologic extent of bone cement","volume":"74","author":"Sun","year":"2011","journal-title":"J. Chin. Med. Assoc."},{"key":"B60","doi-asserted-by":"publisher","first-page":"104477","DOI":"10.1016\/j.compbiomed.2021.104477","article-title":"Biomechanical comparison of four types of instrumentation constructs for revision surgery in lumbar adjacent segment disease: A finite element study","volume":"134","author":"Tan","year":"2021","journal-title":"Comput. Biol. Med."},{"key":"B61","first-page":"25","article-title":"Vertebral augmentation in thoracolumbar compression fractures: A critical review on available evidence and ongoing controversies","volume":"66","author":"Teles","year":"2015","journal-title":"Minerva Ortop. Traumatol."},{"key":"B62","doi-asserted-by":"publisher","first-page":"331","DOI":"10.1007\/s00270-017-1574-8","article-title":"CIRSE guidelines on percutaneous vertebral augmentation","volume":"40","author":"Tsoumakidou","year":"2017","journal-title":"Cardiovasc. Interv. Radiol."},{"key":"B63","doi-asserted-by":"publisher","first-page":"104961","DOI":"10.1016\/j.jmbbm.2021.104961","article-title":"A biomechanical investigation of lumbar interbody fusion techniques","volume":"125","author":"Umale","year":"2022","journal-title":"J. Mech. Behav. Biomed. Mater."},{"key":"B64","doi-asserted-by":"publisher","first-page":"1223","DOI":"10.1007\/s11517-021-02375-1","article-title":"Prediction of complications and fusion outcomes of fused lumbar spine with or without fixation system under whole-body vibration","volume":"59","author":"Wang","year":"2021","journal-title":"Med. Biol. Eng. Comput."},{"key":"B65","doi-asserted-by":"publisher","first-page":"e0151680","DOI":"10.1371\/journal.pone.0151680","article-title":"The effectiveness of percutaneous vertebroplasty is determined by the patient-specific bone condition and the treatment strategy","volume":"11","author":"Widmer Soyka","year":"2016","journal-title":"PloS one"},{"key":"B66","doi-asserted-by":"publisher","first-page":"887","DOI":"10.1007\/s11596-016-1680-x","article-title":"Pedicle screw fixation with kyphoplasty decreases the fracture risk of the treated and adjacent non-treated vertebral bodies: A finite element analysis","volume":"36","author":"Yang","year":"","journal-title":"J. Huazhong Univ. Sci. Technol."},{"key":"B67","doi-asserted-by":"publisher","first-page":"887","DOI":"10.1007\/s11596-016-1680-x","article-title":"Pedicle screw fixation with kyphoplasty decreases the fracture risk of the treated and adjacent non-treated vertebral bodies: A finite element analysis","volume":"36","author":"Yang","year":"","journal-title":"J. Huazhong Univ. Sci. Technol. Med. Sci. ]."},{"key":"B68","doi-asserted-by":"publisher","first-page":"e5675","DOI":"10.1097\/md.0000000000005675","article-title":"Risk factors for recollapse of the augmented vertebrae after percutaneous vertebroplasty for osteoporotic vertebral fractures with intravertebral vacuum cleft","volume":"96","author":"Yu","year":"2017","journal-title":"Medicine"},{"key":"B69","doi-asserted-by":"publisher","first-page":"431","DOI":"10.2147\/cia.S113240","article-title":"Bone cement distribution in the vertebral body affects chances of recompression after percutaneous vertebroplasty treatment in elderly patients with osteoporotic vertebral compression fractures","volume":"12","author":"Zhang","year":"2017","journal-title":"Clin. Interv. Aging"},{"key":"B70","doi-asserted-by":"publisher","first-page":"455","DOI":"10.1080\/10255842.2021.1959557","article-title":"Biomechanics of adjacent segment after three-level lumbar fusion, hybrid single-level semi-rigid fixation with two-level lumbar fusion","volume":"25","author":"Zhang","year":"2022","journal-title":"Comput. Methods Biomechanics Biomed. Eng."},{"key":"B71","doi-asserted-by":"publisher","first-page":"e700","DOI":"10.1016\/j.wneu.2021.06.031","article-title":"Effect of osteoporosis on adjacent segmental degeneration after posterior lumbar interbody fusion under whole body vibration","volume":"152","author":"Zhang","year":"2021","journal-title":"World Neurosurg."},{"key":"B72","doi-asserted-by":"publisher","first-page":"32","DOI":"10.1186\/s13018-018-0733-1","article-title":"Biomechanical effects of different vertebral heights after augmentation of osteoporotic vertebral compression fracture: A three-dimensional finite element analysis","volume":"13","author":"Zhao","year":"2018","journal-title":"J. Orthop. Surg. Res."},{"key":"B73","doi-asserted-by":"publisher","first-page":"143","DOI":"10.1243\/09544119jeim476","article-title":"Load- and displacement-controlled finite element analyses on fusion and non-fusion spinal implants","volume":"223","author":"Zhong","year":"2009","journal-title":"Proc. Inst. Mech. Eng. H."},{"key":"B74","doi-asserted-by":"publisher","first-page":"132","DOI":"10.1186\/s13018-020-01650-5","article-title":"Influence of cement-augmented pedicle screw instrumentation in an osteoporotic lumbosacral spine over the adjacent segments: A 3D finite element study","volume":"15","author":"Zhou","year":"2020","journal-title":"J. Orthop. Surg. Res."},{"key":"B75","doi-asserted-by":"publisher","first-page":"138","DOI":"10.1186\/s13018-021-02225-8","article-title":"Finite element analysis of wedge and biconcave deformity in four different height restoration after augmentation of osteoporotic vertebral compression fractures","volume":"16","author":"Zuo","year":"","journal-title":"J. Orthop. Surg. Res."},{"key":"B76","doi-asserted-by":"publisher","first-page":"138","DOI":"10.1186\/s13018-021-02225-8","article-title":"Finite element analysis of wedge and biconcave deformity in four different height restoration after augmentation of osteoporotic vertebral compression fractures","volume":"16","author":"Zuo","year":"","journal-title":"J. Orthop. Surg. Res."}],"container-title":["Frontiers in Bioengineering and Biotechnology"],"original-title":[],"link":[{"URL":"https:\/\/www.frontiersin.org\/articles\/10.3389\/fbioe.2022.978917\/full","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2022,9,8]],"date-time":"2022-09-08T13:50:30Z","timestamp":1662645030000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.frontiersin.org\/articles\/10.3389\/fbioe.2022.978917\/full"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2022,9,8]]},"references-count":76,"alternative-id":["10.3389\/fbioe.2022.978917"],"URL":"https:\/\/doi.org\/10.3389\/fbioe.2022.978917","relation":{},"ISSN":["2296-4185"],"issn-type":[{"value":"2296-4185","type":"electronic"}],"subject":[],"published":{"date-parts":[[2022,9,8]]},"article-number":"978917"}}