{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,6,16]],"date-time":"2026-06-16T05:37:50Z","timestamp":1781588270460,"version":"3.54.5"},"reference-count":30,"publisher":"Frontiers Media SA","license":[{"start":{"date-parts":[[2023,3,3]],"date-time":"2023-03-03T00:00:00Z","timestamp":1677801600000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"content-domain":{"domain":["frontiersin.org"],"crossmark-restriction":true},"short-container-title":["Front. Bioeng. Biotechnol."],"abstract":"<jats:p><jats:bold>Objective:<\/jats:bold> To select the most appropriate internal fixation method based on the Pauwels angle, in order to provide a new concept for clinical accurate treatment of femoral neck fractures (FNFs).<\/jats:p><jats:p><jats:bold>Methods:<\/jats:bold> FNFs models of Pauwels <jats:inline-formula><mml:math xmlns:mml=\"http:\/\/www.w3.org\/1998\/Math\/MathML\" id=\"m1\"><mml:mrow><mml:mrow><mml:mn>30<\/mml:mn><mml:mo>\u00b0<\/mml:mo><\/mml:mrow><\/mml:mrow><\/mml:math><\/jats:inline-formula>; <jats:inline-formula><mml:math xmlns:mml=\"http:\/\/www.w3.org\/1998\/Math\/MathML\" id=\"m2\"><mml:mrow><mml:mrow><mml:mn>40<\/mml:mn><mml:mo>\u00b0<\/mml:mo><\/mml:mrow><\/mml:mrow><\/mml:math><\/jats:inline-formula>; <jats:inline-formula><mml:math xmlns:mml=\"http:\/\/www.w3.org\/1998\/Math\/MathML\" id=\"m3\"><mml:mrow><mml:mrow><mml:mn>50<\/mml:mn><mml:mo>\u00b0<\/mml:mo><\/mml:mrow><\/mml:mrow><\/mml:math><\/jats:inline-formula>; <jats:inline-formula><mml:math xmlns:mml=\"http:\/\/www.w3.org\/1998\/Math\/MathML\" id=\"m4\"><mml:mrow><mml:mrow><mml:mn>60<\/mml:mn><mml:mo>\u00b0<\/mml:mo><\/mml:mrow><\/mml:mrow><\/mml:math><\/jats:inline-formula> were created respectively. For Pauwels \u2264 <jats:inline-formula><mml:math xmlns:mml=\"http:\/\/www.w3.org\/1998\/Math\/MathML\" id=\"m5\"><mml:mrow><mml:mrow><mml:mn>50<\/mml:mn><mml:mo>\u00b0<\/mml:mo><\/mml:mrow><\/mml:mrow><\/mml:math><\/jats:inline-formula>, 1, 2 and 3 Cannulated Compression Screws (CCS) and Porous Tantalum Screws (PTS) were used to fix the fracture for the models. For Pauwels <jats:inline-formula><mml:math xmlns:mml=\"http:\/\/www.w3.org\/1998\/Math\/MathML\" id=\"m6\"><mml:mrow><mml:mrow><mml:mn>60<\/mml:mn><mml:mo>\u00b0<\/mml:mo><\/mml:mrow><\/mml:mrow><\/mml:math><\/jats:inline-formula>, 3CCS and Medial Buttress Plate (MBP) combined with 1, 2 and 3CCS were used to fix the fracture. Based on the results of the finite element (FE) analysis, the biomechanical properties of each model were compared by analyzing and evaluating the following four parameters: maximal stress of the bone (MBS), maximal stress of the implants (MIS), maximal displacement of bone (MBD), interfragmentary motion (IFM).<\/jats:p><jats:p><jats:bold>Results:<\/jats:bold> At Pauwels <jats:inline-formula><mml:math xmlns:mml=\"http:\/\/www.w3.org\/1998\/Math\/MathML\" id=\"m7\"><mml:mrow><mml:mrow><mml:mn>30<\/mml:mn><mml:mo>\u00b0<\/mml:mo><\/mml:mrow><\/mml:mrow><\/mml:math><\/jats:inline-formula>, the larger parameters were found in 1CCS, which was 94.8\u00a0MPa (MBS), 307.7\u00a0MPa (MIS), 0.86\u00a0mm (MBD) and 0.36\u00a0mm (IFM). In 2CCS group, the parameters were 86.1\u00a0MPa (MBS), 254.4\u00a0MPa (MIS), 0.73\u00a0mm (MBD) and 0.27\u00a0mm (IFM), which were similar to those of PTS. At Pauwels <jats:inline-formula><mml:math xmlns:mml=\"http:\/\/www.w3.org\/1998\/Math\/MathML\" id=\"m8\"><mml:mrow><mml:mrow><mml:mn>40<\/mml:mn><mml:mo>\u00b0<\/mml:mo><\/mml:mrow><\/mml:mrow><\/mml:math><\/jats:inline-formula>; <jats:inline-formula><mml:math xmlns:mml=\"http:\/\/www.w3.org\/1998\/Math\/MathML\" id=\"m9\"><mml:mrow><mml:mrow><mml:mn>50<\/mml:mn><mml:mo>\u00b0<\/mml:mo><\/mml:mrow><\/mml:mrow><\/mml:math><\/jats:inline-formula>, with the increase of the number of used CCS, accordingly, the parameters decreased. Particularly, the MIS (Pauwels <jats:inline-formula><mml:math xmlns:mml=\"http:\/\/www.w3.org\/1998\/Math\/MathML\" id=\"m10\"><mml:mrow><mml:mrow><mml:mn>50<\/mml:mn><mml:mo>\u00b0<\/mml:mo><\/mml:mrow><\/mml:mrow><\/mml:math><\/jats:inline-formula>) of 1CCS was 1,195.3 MPa, but the other were less than the yield range of the materials. At Pauwels <jats:inline-formula><mml:math xmlns:mml=\"http:\/\/www.w3.org\/1998\/Math\/MathML\" id=\"m11\"><mml:mrow><mml:mrow><mml:mn>60<\/mml:mn><mml:mo>\u00b0<\/mml:mo><\/mml:mrow><\/mml:mrow><\/mml:math><\/jats:inline-formula>, the MBS of 3CCS group was 128.6 Mpa, which had the risk of failure. In 2CCS + MBP group, the parameters were 124.2\u00a0MPa (MBS), 602.5\u00a0MPa (MIS), 0.75\u00a0mm (MBD) and 0.48\u00a0mm (IFM), The model stability was significantly enhanced after adding MBP.<\/jats:p><jats:p><jats:bold>Conclusion:<\/jats:bold> Pauwels type \u2160 (&amp;lt;<jats:inline-formula><mml:math xmlns:mml=\"http:\/\/www.w3.org\/1998\/Math\/MathML\" id=\"m12\"><mml:mrow><mml:mrow><mml:mn>30<\/mml:mn><mml:mo>\u00b0<\/mml:mo><\/mml:mrow><\/mml:mrow><\/mml:math><\/jats:inline-formula>) fractures can reduce the number of CCS, and PTS is an appropriate alternative treatment. For Pauwels type \u2161 fractures (<jats:inline-formula><mml:math xmlns:mml=\"http:\/\/www.w3.org\/1998\/Math\/MathML\" id=\"m13\"><mml:mrow><mml:mrow><mml:mn>30<\/mml:mn><mml:mo>\u00b0<\/mml:mo><\/mml:mrow><mml:mo>\u223c<\/mml:mo><mml:mrow><mml:mn>50<\/mml:mn><mml:mo>\u00b0<\/mml:mo><\/mml:mrow><\/mml:mrow><\/mml:math><\/jats:inline-formula>), the 3CCS fixation method is still recommended. For Pauwels type \u2162 fractures (&amp;gt;<jats:inline-formula><mml:math xmlns:mml=\"http:\/\/www.w3.org\/1998\/Math\/MathML\" id=\"m14\"><mml:mrow><mml:mrow><mml:mn>50<\/mml:mn><mml:mo>\u00b0<\/mml:mo><\/mml:mrow><\/mml:mrow><\/mml:math><\/jats:inline-formula>), it is recommended to add MBP to the medial femoral neck and combine with 2CCS to establish a satisfactory fracture healing environment.<\/jats:p>","DOI":"10.3389\/fbioe.2023.1143575","type":"journal-article","created":{"date-parts":[[2023,3,3]],"date-time":"2023-03-03T06:48:52Z","timestamp":1677826132000},"update-policy":"https:\/\/doi.org\/10.3389\/crossmark-policy","source":"Crossref","is-referenced-by-count":10,"title":["Biomechanical study of internal fixation methods for femoral neck fractures based on Pauwels angle"],"prefix":"10.3389","volume":"11","author":[{"given":"Fuyang","family":"Wang","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Yuchen","family":"Liu","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Yi","family":"Huo","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Ziming","family":"Wang","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Jinge","family":"Zhang","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Minghao","family":"Xu","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Kaiming","family":"Ma","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Linbao","family":"Wang","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Yongtao","family":"Lu","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Liangliang","family":"Cheng","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Dewei","family":"Zhao","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"1965","published-online":{"date-parts":[[2023,3,3]]},"reference":[{"key":"B1","doi-asserted-by":"publisher","first-page":"544","DOI":"10.1097\/BOT.0b013e31814b822e","article-title":"Vertically oriented femoral neck fractures: Mechanical analysis of four fixation techniques","volume":"21","author":"Aminian","year":"2007","journal-title":"J. Orthop. Trauma"},{"key":"B2","doi-asserted-by":"publisher","first-page":"358","DOI":"10.1097\/00005131-200106000-00009","article-title":"Pauwels' classification of femoral neck fractures: Correct interpretation of the original","volume":"15","author":"Barton\u00ed\u010dek","year":"2001","journal-title":"J. Orthop. Trauma"},{"key":"B3","doi-asserted-by":"publisher","first-page":"1","DOI":"10.4055\/cios.2019.11.1.1","article-title":"Biomechanical evaluation of internal fixation of Pauwels type III femoral neck fractures: A systematic review of various fixation methods","volume":"11","author":"Cha","year":"2019","journal-title":"Clin. Orthop. Surg."},{"key":"B4","doi-asserted-by":"publisher","first-page":"236","DOI":"10.1097\/TA.0b013e3181c428ce","article-title":"Challenges in the treatment of femoral neck fractures in the nonelderly adult","volume":"68","author":"Davidovitch","year":"2010","journal-title":"J. Trauma"},{"key":"B5","doi-asserted-by":"publisher","first-page":"014504","DOI":"10.1115\/1.4003129","article-title":"Experimental validation of a finite element model of the proximal femur using digital image correlation and a composite bone model","volume":"133","author":"Dickinson","year":"2011","journal-title":"J. Biomech. Eng."},{"key":"B6","doi-asserted-by":"publisher","first-page":"1141","DOI":"10.1243\/09544119jeim799","article-title":"A biomechanical evaluation of orthopaedic implants for hip fractures by finite element analysis and in-vitro tests","volume":"224","author":"Eberle","year":"2010","journal-title":"Proc. Inst. Mech. Eng. H."},{"key":"B7","doi-asserted-by":"publisher","first-page":"891338","DOI":"10.3389\/fbioe.2022.891338","article-title":"Two cannulated screws provide sufficient biomechanical strength for prophylactic fixation in adult patients with an aggressive benign femoral neck lesion","volume":"10","author":"Fu","year":"2022","journal-title":"Front. Bioeng. Biotechnol."},{"key":"B8","doi-asserted-by":"publisher","first-page":"1836","DOI":"10.1016\/j.jbiomech.2016.04.021","article-title":"Implicit modeling of screw threads for efficient finite element analysis of complex bone-implant systems","volume":"49","author":"Inzana","year":"2016","journal-title":"J. Biomech."},{"key":"B9","doi-asserted-by":"publisher","first-page":"36","DOI":"10.1097\/00003086-198904000-00006","article-title":"Controlled mechanical stimulation in the treatment of tibial fractures","volume":"241","author":"Kenwright","year":"1989","journal-title":"Clin. Orthop. Relat. Res."},{"key":"B10","doi-asserted-by":"publisher","first-page":"297","DOI":"10.1007\/s00402-006-0143-4","article-title":"Two cannulated hip screws for femoral neck fractures: Treatment of choice or asking for trouble?","volume":"126","author":"Krastman","year":"2006","journal-title":"Arch. Orthop. Trauma Surg."},{"key":"B11","doi-asserted-by":"publisher","first-page":"e182","DOI":"10.2106\/jbjs.L.01185","article-title":"Assessment of femoral head and head-neck junction perfusion following surgical hip dislocation using gadolinium-enhanced magnetic resonance imaging: A cadaveric study","volume":"95","author":"Lazaro","year":"2013","journal-title":"J. Bone Jt. Surg. Am."},{"key":"B12","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1155\/2018\/1271762","article-title":"Optimum configuration of cannulated compression screws for the fixation of unstable femoral neck fractures: Finite element analysis evaluation","volume":"2018","author":"Li","year":"2018","journal-title":"Biomed. Res. Int."},{"key":"B13","doi-asserted-by":"publisher","first-page":"1895","DOI":"10.1016\/j.injury.2019.08.024","article-title":"Medial anatomical buttress plate in treating displaced femoral neck fracture a finite element analysis","volume":"50","author":"Li","year":"","journal-title":"Injury"},{"key":"B14","doi-asserted-by":"publisher","first-page":"76","DOI":"10.1186\/s13018-019-1097-x","article-title":"Comparison of three different internal fixation implants in treatment of femoral neck fracture-a finite element analysis","volume":"14","author":"Li","year":"","journal-title":"J. Orthop. Surg. Res."},{"key":"B15","doi-asserted-by":"publisher","first-page":"1654","DOI":"10.2106\/JBJS.G.01353","article-title":"Results of internal fixation of Pauwels type-3 vertical femoral neck fractures","volume":"90","author":"Liporace","year":"2008","journal-title":"J. Bone Jt. Surg. Am."},{"key":"B16","doi-asserted-by":"publisher","first-page":"89","DOI":"10.1016\/j.ijsu.2018.01.050","article-title":"Sliding hip screw versus cannulated cancellous screws for fixation of femoral neck fracture in adults: A systematic review","volume":"52","author":"Ma","year":"2018","journal-title":"Int. J. Surg."},{"key":"B17","first-page":"438","article-title":"Two or three screws for fixation of femoral neck fractures?","volume":"32","author":"Maurer","year":"2003","journal-title":"Am. J. Orthop. (Belle Mead NJ)"},{"key":"B18","doi-asserted-by":"publisher","first-page":"S1","DOI":"10.1097\/bot.0000000000001369","article-title":"Treatment of young femoral neck fractures","volume":"33","author":"Medda","year":"2019","journal-title":"J. Orthop. Trauma"},{"key":"B19","doi-asserted-by":"publisher","first-page":"429","DOI":"10.1016\/j.mehy.2015.01.029","article-title":"Application of a medial buttress plate may prevent many treatment failures seen after fixation of vertical femoral neck fractures in young adults","volume":"84","author":"Mir","year":"2015","journal-title":"Med. Hypotheses"},{"key":"B20","doi-asserted-by":"publisher","first-page":"1519","DOI":"10.1016\/S0140-6736(17)30066-1","article-title":"Fracture fixation in the operative management of hip fractures (FAITH): An international, multicentre, randomised controlled trial","volume":"389","author":"Nauth","year":"2017","journal-title":"Lancet"},{"key":"B21","first-page":"490","article-title":"Results of internal fixation of Pauwels type-3 vertical femoral neck fractures","volume":"91","author":"Parker","year":"2009","journal-title":"J. Bone Jt. Surg. Am."},{"key":"B22","doi-asserted-by":"publisher","first-page":"99","DOI":"10.1016\/s1350-4533(02)00185-6","article-title":"Finite element study of trochanteric gamma nail for trochanteric fracture","volume":"25","author":"Sitthiseripratip","year":"2003","journal-title":"Med. Eng. Phys."},{"key":"B23","doi-asserted-by":"publisher","first-page":"805","DOI":"10.1007\/s00776-011-0145-0","article-title":"Comparative study of two materials for dynamic hip screw during fall and gait loading: Titanium alloy and stainless steel","volume":"16","author":"Taheri","year":"2011","journal-title":"J. Orthop. Sci."},{"key":"B24","doi-asserted-by":"publisher","first-page":"C1","DOI":"10.1016\/s0020-1383(02)00324-8","article-title":"Epidemiology of femoral neck fractures","volume":"33","author":"Thorngren","year":"2002","journal-title":"Injury"},{"key":"B25","doi-asserted-by":"publisher","first-page":"108658","DOI":"10.1016\/j.biopha.2019.108658","article-title":"Finite element analysis of different internal fixation methods for the treatment of Pauwels type III femoral neck fracture","volume":"112","author":"Tianye","year":"2019","journal-title":"Biomed. Pharmacother."},{"key":"B26","doi-asserted-by":"publisher","first-page":"359","DOI":"10.1016\/s0268-0033(98)00097-7","article-title":"The effects of external mechanical stimulation on the healing of diaphyseal osteotomies fixed by flexible external fixation","volume":"13","author":"Wolf","year":"1998","journal-title":"Clin. Biomech. (Bristol, Avon)"},{"key":"B27","doi-asserted-by":"publisher","first-page":"515","DOI":"10.1142\/s0219519410003496","article-title":"Differential thermography for experimental, full-field stress analysis of hip arthroplasty","volume":"10","author":"Zanetti","year":"2012","journal-title":"J. Mech. Med. Biol."},{"key":"B28","doi-asserted-by":"publisher","first-page":"842","DOI":"10.1186\/s12891-020-03853-7","article-title":"Influence of the proximal screws of buttress plates on the stability of vertical femoral neck fractures: A finite element analysis","volume":"21","author":"Zhan","year":"2020","journal-title":"BMC Musculoskelet. Disord."},{"key":"B29","doi-asserted-by":"publisher","first-page":"1964","DOI":"10.1111\/os.13285","article-title":"A new method to protect blood supply in the treatment of femoral neck fractures: Bidirectional compression porous tantalum screws","volume":"14","author":"Zhao","year":"2022","journal-title":"Orthop. Surg."},{"key":"B30","doi-asserted-by":"publisher","first-page":"2011","DOI":"10.1007\/s11999-017-5318-5","article-title":"Epiphyseal arterial network and inferior retinacular artery seem critical to femoral head perfusion in adults with femoral neck fractures","volume":"475","author":"Zhao","year":"2017","journal-title":"Clin. Orthop. Relat. Res."}],"container-title":["Frontiers in Bioengineering and Biotechnology"],"original-title":[],"link":[{"URL":"https:\/\/www.frontiersin.org\/articles\/10.3389\/fbioe.2023.1143575\/full","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,3,3]],"date-time":"2023-03-03T06:48:55Z","timestamp":1677826135000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.frontiersin.org\/articles\/10.3389\/fbioe.2023.1143575\/full"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2023,3,3]]},"references-count":30,"alternative-id":["10.3389\/fbioe.2023.1143575"],"URL":"https:\/\/doi.org\/10.3389\/fbioe.2023.1143575","relation":{},"ISSN":["2296-4185"],"issn-type":[{"value":"2296-4185","type":"electronic"}],"subject":[],"published":{"date-parts":[[2023,3,3]]},"article-number":"1143575"}}