{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,9,22]],"date-time":"2026-09-22T04:35:34Z","timestamp":1790051734779,"version":"4.0.1"},"reference-count":27,"publisher":"Frontiers Media SA","license":[{"start":{"date-parts":[[2023,4,28]],"date-time":"2023-04-28T00:00:00Z","timestamp":1682640000000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"content-domain":{"domain":["frontiersin.org"],"crossmark-restriction":true},"short-container-title":["Front. Bioeng. Biotechnol."],"abstract":"<jats:p>The placement of acetabular implant components determines the short- and long-term outcomes of total hip replacement (THR) and a number of tools have been developed to assist the surgeon in achieving cup orientation to match the surgical plan. However, the accuracy and precision of 3D-CT for the measurement of acetabular component position and orientation is yet to be established. To investigate this, we compared measurements of cobalt chrome acetabular components implanted into 2 different bony pelvic models between a coordinate measuring Faro arm and 3 different low dose CT images, including 3D-CT, 2D anterior pelvic plane (APP) referenced CT and 2D scanner referenced (SR) CT. Intra-observer differences were assessed using the Intraclass correlation coefficient (ICC). The effect of imaging the pelvis positioned in 3 different orientations within the CT scanner was also assessed. The measured parameters were the angles of inclination and version. 3D-CT measurements were found to closely match the \u201ctrue values\u201d of the component position measurements, compared with the 2D-CT methods. ICC analysis also showed good agreement between the coordinate measuring arm (CMA) and 3D-CT but poor agreement between the 2D SR method, in the results from two observers. When using the coordinate system of the CT scanner, the measurements consistently produced the greatest error; this method yielded values up to 34\u00b0 different from the reference digitising arm. However, the difference between the true inclination and version angles and those measured from 3D APP CT was below half a degree in all cases. We concluded that low radiation dose 3D-CT is a validated reference standard for the measurement of acetabular cup orientation.<\/jats:p>","DOI":"10.3389\/fbioe.2023.1150061","type":"journal-article","created":{"date-parts":[[2023,4,28]],"date-time":"2023-04-28T01:57:15Z","timestamp":1682647035000},"update-policy":"https:\/\/doi.org\/10.3389\/crossmark-policy","source":"Crossref","is-referenced-by-count":4,"title":["The accuracy and precision of acetabular implant measurements from CT imaging"],"prefix":"10.3389","volume":"11","author":[{"given":"Johann","family":"Henckel","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Angelika","family":"Ramesh","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Harry","family":"Hothi","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Robin","family":"Richards","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Anna","family":"Di Laura","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Alister","family":"Hart","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"1965","published-online":{"date-parts":[[2023,4,28]]},"reference":[{"key":"B1","doi-asserted-by":"publisher","first-page":"1196","DOI":"10.1302\/0301-620x.104b11.bjj-2022-0194.r2","article-title":"Validating the use of 3D biplanar radiography versus CT when measuring femoral anteversion after total hip arthroplasty","author":"Anderson","year":"2022","journal-title":"Bone. Jt. J."},{"key":"B2","doi-asserted-by":"publisher","first-page":"731","DOI":"10.1007\/s00264-016-3240-1","article-title":"Accuracy of measuring acetabular cup position after total hip arthroplasty: Comparison between a radiographic planning software and three-dimensional computed tomography","volume":"41","author":"Bayraktar","year":"2017","journal-title":"Int. Orthop."},{"key":"B3","doi-asserted-by":"publisher","first-page":"470","DOI":"10.1016\/j.ejrad.2006.08.008","article-title":"Multi-detector CT imaging in the postoperative orthopedic patient with metal hardware","volume":"60","author":"Berg","year":"2006","journal-title":"Eur. J. Radiol."},{"key":"B4","doi-asserted-by":"publisher","first-page":"563","DOI":"10.1016\/j.otsr.2019.10.019","article-title":"Improved accuracy of CT based measurements for anterior prominence of acetabular prosthesis using a novel protocol based on Anatomical Landmarks","volume":"106","author":"Brownlie","year":"2020","journal-title":"Orthop. Traumatol. Surg. Res."},{"key":"B5","doi-asserted-by":"publisher","first-page":"485","DOI":"10.3109\/17453674.2015.1017791","article-title":"2D measurements of cup orientation are less reliable than 3D measurements","volume":"86","author":"Davda","year":"2015","journal-title":"Acta Orthop."},{"key":"B6","doi-asserted-by":"publisher","first-page":"50","DOI":"10.1051\/sicotj\/2017034","article-title":"Computer assisted navigation in total knee and hip arthroplasty","volume":"50","author":"Deep","year":"2017","journal-title":"SICOT-J"},{"key":"B7","doi-asserted-by":"publisher","first-page":"531","DOI":"10.5301\/hipint.5000289","article-title":"Precision of acetabular cup placement in robotic integrated total hip arthroplasty","volume":"25","author":"Elson","year":"2015","journal-title":"Hip Int."},{"key":"B8","doi-asserted-by":"publisher","first-page":"26","DOI":"10.1051\/sicotj\/2021025","article-title":"Advances and innovations in total hip arthroplasty","volume":"7","author":"Fontalis","year":"2021","journal-title":"SICOT-J"},{"key":"B9","volume-title":"The ionising radiation (medical exposure) Regulations 2000: Programme of inspections (S.I. 2000\/1059)","year":"2001"},{"key":"B10","doi-asserted-by":"publisher","first-page":"3282","DOI":"10.1016\/j.jbiomech.2008.08.013","article-title":"Structural properties of fourth-generation composite femurs and tibias","volume":"41","author":"Heiner","year":"2008","journal-title":"J. Biomech."},{"key":"B11","doi-asserted-by":"publisher","first-page":"342","DOI":"10.5435\/jaaos-d-16-00719","article-title":"3D-printed patient-specific guides for hip arthroplasty","volume":"26","author":"Henckel","year":"2018","journal-title":"J. Am. Acad. Orthop. Surg."},{"key":"B12","doi-asserted-by":"publisher","first-page":"1016","DOI":"10.1259\/0007-1285-46-552-1016","article-title":"Computerized transverse axial scanning (tomography): Part 1. Description of system","volume":"46","author":"Hounsfield","year":"1973","journal-title":"Br. J. Radiol."},{"key":"B13","doi-asserted-by":"publisher","first-page":"65","DOI":"10.1007\/s00590-018-2279-7","article-title":"A prospective clinical trial to assess the accuracy of an MRI-based patient-specific acetabular instrument guide in total hip arthroplasty","volume":"29","author":"Inoue","year":"2019","journal-title":"Eur. J. Orthop. Surg. Traumatol."},{"key":"B14","first-page":"607","article-title":"The influence on the images of computed tomography caused by the use of artificial cranial reconstructive materials","volume":"36","author":"Itokawa","year":"2008","journal-title":"No Shinkei Geka"},{"key":"B15","doi-asserted-by":"publisher","first-page":"698","DOI":"10.1177\/02841851211009466","article-title":"Pelvic tilt impacts cup orientation on CT: How accurate is the gold standard?","volume":"63","author":"Kaiser","year":"2021","journal-title":"Acta Radiol."},{"key":"B16","doi-asserted-by":"publisher","first-page":"18877","DOI":"10.1002\/rcs.1887","article-title":"Inter- and intra-operator reliability in patient-specific template positioning for total hip arthroplasty. A cadaver study","volume":"14","author":"Kr\u00e4mer","year":"2018","journal-title":"Int. J. Med. Robot."},{"key":"B17","doi-asserted-by":"publisher","first-page":"402","DOI":"10.1016\/j.tripleo.2006.07.015","article-title":"Accuracy of measurements and reliability of landmark identification with computed tomography (CT) techniques in the maxillofacial area: A systematic review","volume":"104","author":"Lou","year":"2007","journal-title":"Oral Surg. Oral Med. Oral Pathol. Oral Radiol. Endod."},{"key":"B18","doi-asserted-by":"publisher","first-page":"886","DOI":"10.1186\/s12891-022-05835-3","article-title":"Assessing component orientation of total hip arthroplasty using the low-dose bi-planar radiographs","volume":"23","author":"Ma","year":"2022","journal-title":"BMC Musculoskelet. Disord."},{"key":"B19","doi-asserted-by":"publisher","first-page":"263","DOI":"10.1016\/j.jbiomech.2004.02.007","article-title":"Imaging knee position using MRI, RSA\/CT and 3D digitisation","volume":"38","author":"McPherson","year":"2005","journal-title":"J. Biomech."},{"key":"B20","doi-asserted-by":"publisher","first-page":"630","DOI":"10.1097\/rct.0b013e3181568b27","article-title":"Metal artifact reduction by the alteration of technical factors in multidetector computed tomography: A 3-dimensional quantitative assessment","volume":"32","author":"Moon","year":"2008","journal-title":"J. Comput. Assist. Tomogr."},{"key":"B21","doi-asserted-by":"publisher","first-page":"228","DOI":"10.1302\/0301-620x.75b2.8444942","article-title":"The definition and measurement of acetabular orientation","volume":"75","author":"Murray","year":"1993","journal-title":"J. Bone Jt. Surg. Br."},{"key":"B22","doi-asserted-by":"publisher","first-page":"64333","DOI":"10.7717\/peerj.6433","article-title":"Variation in pelvic shape and size in eastern European males: A computed tomography comparative study","volume":"7","author":"Musielak","year":"2019","journal-title":"PeerJ"},{"key":"B23","doi-asserted-by":"publisher","first-page":"1644","DOI":"10.1016\/j.arth.2013.02.014","article-title":"Accuracy and precision of version angle measurements of the acetabular component after total hip arthroplasty","volume":"9","author":"Nishino","year":"2013","journal-title":"J. Arthroplasty"},{"key":"B24","doi-asserted-by":"publisher","first-page":"621","DOI":"10.1097\/rct.0b013e318149e215","article-title":"Computed tomographic metal artifact reduction for the detection and quantitation of small features near large metallic implants: A comparison of published methods","volume":"32","author":"Rinkel","year":"2008","journal-title":"J. Comput. Assist. Tomogr."},{"key":"B25","doi-asserted-by":"publisher","first-page":"241","DOI":"10.1111\/os.12445","article-title":"Non-equivalent results from different anteversion measurements methods for the evaluation of the acetabular cup orientation in total hip arthroplasty","volume":"11","author":"Snijders","year":"2019","journal-title":"Orthop. Surg."},{"key":"B26","doi-asserted-by":"publisher","first-page":"1342","DOI":"10.1302\/0301-620x.98b10.37808","article-title":"Patient-specific instrumentation improves the accuracy of acetabular component placement in total hip arthroplasty","volume":"98","author":"Spencer-Gardner","year":"2016","journal-title":"Bone. Jt. J."},{"key":"B27","doi-asserted-by":"publisher","first-page":"621","DOI":"10.1016\/j.arth.2013.08.004","article-title":"The use of combined anteversion in total hip arthroplasty for patients with developmental dysplasia of the hip","volume":"29","author":"Zhang","year":"2014","journal-title":"J. Arthroplasty"}],"container-title":["Frontiers in Bioengineering and Biotechnology"],"original-title":[],"link":[{"URL":"https:\/\/www.frontiersin.org\/articles\/10.3389\/fbioe.2023.1150061\/full","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,4,28]],"date-time":"2023-04-28T01:57:19Z","timestamp":1682647039000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.frontiersin.org\/articles\/10.3389\/fbioe.2023.1150061\/full"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2023,4,28]]},"references-count":27,"alternative-id":["10.3389\/fbioe.2023.1150061"],"URL":"https:\/\/doi.org\/10.3389\/fbioe.2023.1150061","relation":{},"ISSN":["2296-4185"],"issn-type":[{"value":"2296-4185","type":"electronic"}],"subject":[],"published":{"date-parts":[[2023,4,28]]},"article-number":"1150061"}}