{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,27]],"date-time":"2026-10-27T17:42:15Z","timestamp":1793122935648,"version":"4.5.0"},"reference-count":30,"publisher":"Frontiers Media SA","license":[{"start":{"date-parts":[[2023,8,4]],"date-time":"2023-08-04T00:00:00Z","timestamp":1691107200000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"content-domain":{"domain":["frontiersin.org"],"crossmark-restriction":true},"short-container-title":["Front. Bioeng. Biotechnol."],"abstract":"<jats:p>\n                    <jats:bold>Purpose:<\/jats:bold>\n                    To analyze and compare sensitive\n                    <jats:italic>in vivo<\/jats:italic>\n                    characteristics for screening early keratoconus.\n                  <\/jats:p>\n                  <jats:p>\n                    <jats:bold>Methods:<\/jats:bold>\n                    This multicenter, case-control study included 712 eyes, after matching for age and biomechanically corrected intraocular pressure, from three clinics in different cities. The keratoconus (\n                    <jats:italic>n<\/jats:italic>\n                    = 288), early keratoconus (\n                    <jats:italic>n<\/jats:italic>\n                    = 91), and normal cornea (\n                    <jats:italic>n<\/jats:italic>\n                    = 333) groups included eyes diagnosed with bilateral keratoconus, fellow eyes with relatively normal topography with unilateral keratoconus, and normal eyes before refractive surgery, respectively. After adjusting for central corneal thickness, differences\n                    <jats:italic>in vivo<\/jats:italic>\n                    characteristics were analyzed among the three groups. The\n                    <jats:italic>in vivo<\/jats:italic>\n                    characteristics were measured by Pentacam and Corvis ST. Fifty-four indices were evaluated to screen for a sensitive index for the detection of early keratoconus.\n                  <\/jats:p>\n                  <jats:p>\n                    <jats:bold>Results:<\/jats:bold>\n                    Significant differences were observed in 26 of the 36 corneal biomechanical indeces between the early keratoconus and normal corneas. The area under the receiver operating characteristic curve of tomographic and biomechanical index, Belin\/Ambr\u00f3sio deviation, and Da in differentiating keratoconus from normal cornea was 1.000. Among the top five indeces of the area under the receiver operating characteristic curve for detecting early keratoconus, the corneal biomechanical-related index accounted for 80% (4\/5), including A1 dArc length, highest concavity radius, A2 time, and tomographic and biomechanical index, of which the area under the receiver operating characteristic curve of A1 dArc length was 0.901.\n                  <\/jats:p>\n                  <jats:p>\n                    <jats:bold>Conclusion:<\/jats:bold>\n                    A1 dArc length and several corneal biomechanical indices are highly sensitive for the detection of early keratoconus, even in the absence of topographic abnormalities. Ophthalmologists should focus on the clinical application of corneal biomechanics and combine corneal tomography for the timely and accurate detection of early keratoconus.\n                  <\/jats:p>","DOI":"10.3389\/fbioe.2023.1158299","type":"journal-article","created":{"date-parts":[[2023,8,4]],"date-time":"2023-08-04T06:43:30Z","timestamp":1691131410000},"update-policy":"https:\/\/doi.org\/10.3389\/crossmark-policy","source":"Crossref","is-referenced-by-count":14,"title":["Screening of sensitive in vivo characteristics for early keratoconus diagnosis: a multicenter study"],"prefix":"10.3389","volume":"11","author":[{"given":"Xuan","family":"Chen","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Huazheng","family":"Cao","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Yan","family":"Huo","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Jiaxin","family":"Song","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Haohan","family":"Zou","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Jing","family":"Li","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Jie","family":"Hou","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Yan","family":"Wang","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"1965","published-online":{"date-parts":[[2023,8,4]]},"reference":[{"key":"B1","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1155\/2018\/5983530","article-title":"Prevalence of keratoconus in A refractive surgery population","volume":"2018","author":"Al-Amri","year":"2018","journal-title":"J. Ophthalmol."},{"key":"B2","doi-asserted-by":"publisher","first-page":"434","DOI":"10.3928\/1081597X-20170426-02","article-title":"Integration of scheimpflug-based corneal tomography and biomechanical assessments for enhancing ectasia detection","volume":"33","author":"Ambr\u00f3sio","year":"2017","journal-title":"J. Refract. Surg."},{"key":"B3","doi-asserted-by":"publisher","first-page":"435","DOI":"10.1016\/S0014-4835(80)80027-3","article-title":"Biomechanical properties of keratoconus and normal corneas","volume":"31","author":"Andreassen","year":"1980","journal-title":"Exp. Eye Res."},{"key":"B4","doi-asserted-by":"publisher","first-page":"318","DOI":"10.3928\/1081597X-20220225-01","article-title":"Biomechanical evaluation of topographically and tomographically normal fellow eyes of patients with keratoconus","volume":"38","author":"Asroui","year":"2022","journal-title":"J. Refract. Surg."},{"key":"B5","doi-asserted-by":"publisher","first-page":"4","DOI":"10.1167\/Tvst.9.7.4","article-title":"Depth-dependent corneal biomechanical properties in normal and keratoconic subjects by optical coherence elastography","volume":"9","author":"De Stefano","year":"2020","journal-title":"Transl. Vis. Sci. Technol."},{"key":"B6","doi-asserted-by":"publisher","first-page":"1849","DOI":"10.1016\/j.ophtha.2008.04.028","article-title":"Ectasia after refractive surgery","volume":"115","author":"Duffey","year":"2008","journal-title":"Ophthalmology"},{"key":"B7","doi-asserted-by":"publisher","first-page":"175","DOI":"10.1016\/J.Joco.2017.05.002","article-title":"Keratoconus diagnosis using Corvis ST measured biomechanical parameters","volume":"29","author":"Elham","year":"2017","journal-title":"J. Curr. Ophthalmol."},{"key":"B8","doi-asserted-by":"publisher","first-page":"7","DOI":"10.1016\/J.Ajo.2018.08.054","article-title":"Enhanced ectasia detection using corneal tomography and biomechanics","volume":"197","author":"Ferreira-Mendes","year":"2019","journal-title":"Am. J. Ophthalmol."},{"key":"B9","doi-asserted-by":"publisher","first-page":"270","DOI":"10.3928\/1081597X-20200212-03","article-title":"A systematic review of subclinical keratoconus and forme fruste keratoconus","volume":"36","author":"Henriquez","year":"2020","journal-title":"J. Refract. Surg."},{"key":"B10","doi-asserted-by":"publisher","first-page":"364","DOI":"10.3928\/1081597X-20220601-01","article-title":"Evaluation of corneal biomechanical indices in distinguishing between normal, very asymmetric, and bilateral keratoconic eyes","volume":"38","author":"Herber","year":"2022","journal-title":"J. Refract. Surg."},{"key":"B11","doi-asserted-by":"publisher","first-page":"885","DOI":"10.1016\/J.Ajo.2013.12.024","article-title":"Corneal biomechanics as A function of intraocular pressure and pachymetry by dynamic infrared signal and Scheimpflug imaging analysis in normal eyes","volume":"157","author":"Huseynova","year":"2014","journal-title":"Am. J. Ophthalmol."},{"key":"B12","doi-asserted-by":"publisher","first-page":"77","DOI":"10.1001\/Jama.2020.20245","article-title":"Refractive surgery in the US in 2021","volume":"326","author":"Jabbour","year":"2021","journal-title":"JAMA"},{"key":"B13","doi-asserted-by":"publisher","first-page":"2085","DOI":"10.1016\/S0140-6736(18)33209-4","article-title":"Refractive surgery","volume":"393","author":"Kim","year":"2019","journal-title":"Lancet"},{"key":"B14","doi-asserted-by":"publisher","first-page":"845","DOI":"10.1136\/Bjo.2008.147371","article-title":"Chasing the suspect: Keratoconus","volume":"93","author":"Klyce","year":"2009","journal-title":"Br. J. Ophthalmol."},{"key":"B15","doi-asserted-by":"publisher","first-page":"215","DOI":"10.1097\/ICO.0000000000002129","article-title":"Correlation between corneal biomechanical indices and the severity of keratoconus","volume":"39","author":"Koh","year":"2020","journal-title":"Cornea"},{"key":"B16","doi-asserted-by":"publisher","first-page":"697","DOI":"10.1007\/S00347-020-01231-1","article-title":"Keratoconus detection and classification from parameters of the Corvis\u00aeST: A study based on algorithms of machine learning","volume":"118","author":"Langenbucher","year":"2021","journal-title":"Ophthalmologe"},{"key":"B17","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1155\/2017\/8515742","article-title":"Repeatability and reproducibility of intraocular pressure and dynamic corneal response parameters assessed by the Corvis ST","volume":"2017","author":"Lopes","year":"2017","journal-title":"J. Ophthalmol."},{"key":"B18","doi-asserted-by":"publisher","first-page":"753","DOI":"10.1007\/S40123-021-00383-W","article-title":"Ectasia after corneal refractive surgery: A systematic review","volume":"10","author":"Moshirfar","year":"2021","journal-title":"Ophthalmol. Ther."},{"key":"B19","doi-asserted-by":"publisher","first-page":"1905","DOI":"10.3390\/Jcm10091905","article-title":"Evaluation of intraocular pressure and other biomechanical parameters to distinguish between subclinical keratoconus and healthy corneas","volume":"10","author":"Peris-Mart\u00ednez","year":"2021","journal-title":"J. Clin. Med."},{"key":"B20","doi-asserted-by":"publisher","first-page":"297","DOI":"10.1016\/S0039-6257(97)00119-7","volume":"42","author":"Rabinowitz","year":"1998","journal-title":"Keratoconus. Surv. Ophthalmol."},{"key":"B21","doi-asserted-by":"publisher","first-page":"1327","DOI":"10.1016\/S0886-3350(99)00195-9","article-title":"KISA% index: A quantitative videokeratography algorithm embodying minimal topographic criteria for diagnosing keratoconus","volume":"25","author":"Rabinowitz","year":"1999","journal-title":"J. Cataract. Refract. Surg."},{"key":"B22","doi-asserted-by":"publisher","first-page":"991","DOI":"10.1016\/J.Jcrs.2014.04.013","article-title":"Biomechanics of corneal ectasia and biomechanical treatments","volume":"40","author":"Roberts","year":"2014","journal-title":"J. Cataract. Refract. Surg."},{"key":"B23","doi-asserted-by":"publisher","first-page":"101559","DOI":"10.1016\/J.Clae.2021.101559","article-title":"Keratoconus: An updated review","volume":"45","author":"Santodomingo-Rubido","year":"2022","journal-title":"Cont. Lens Anterior Eye."},{"key":"B24","doi-asserted-by":"publisher","first-page":"1025","DOI":"10.1097\/ICO.0000000000001639","article-title":"Diagnostic ability of corneal shape and biomechanical parameters for detecting frank keratoconus","volume":"37","author":"Sedaghat","year":"2018","journal-title":"Cornea"},{"key":"B25","doi-asserted-by":"publisher","first-page":"644","DOI":"10.1111\/Aos.14700","article-title":"Evaluation of corvisst biomechanical parameters and anterior segment optical coherence tomography for diagnosing forme fruste keratoconus","volume":"99","author":"Shiga","year":"2021","journal-title":"Acta Ophthalmol."},{"key":"B26","doi-asserted-by":"publisher","first-page":"E199","DOI":"10.1111\/Aos.12590","article-title":"Correlation of the KISA% index and Scheimpflug tomography in \u201cnormal,\u201d \u201csubclinical,\u201d \u201ckeratoconus-suspect\u201d and \u201cclinically manifest\u201d keratoconus eyes","volume":"93","author":"Steinberg","year":"","journal-title":"Acta Ophthalmol."},{"key":"B27","doi-asserted-by":"publisher","first-page":"1404","DOI":"10.1097\/ICO.0000000000000598","article-title":"Screening for keratoconus with new dynamic biomechanical in vivo Scheimpflug analyses","volume":"34","author":"Steinberg","year":"","journal-title":"Cornea"},{"key":"B28","doi-asserted-by":"publisher","first-page":"468","DOI":"10.3928\/1081597X-20140521-01","article-title":"Ocular biomechanical metrics by Corvis ST in healthy Brazilian patients","volume":"30","author":"Valbon","year":"2014","journal-title":"J. Refract. Surg."},{"key":"B29","doi-asserted-by":"publisher","first-page":"803","DOI":"10.3928\/1081597X-20160629-01","article-title":"Detection of keratoconus with A new biomechanical index","volume":"32","author":"Vinciguerra","year":"","journal-title":"J. Refract. Surg."},{"key":"B30","doi-asserted-by":"publisher","first-page":"550","DOI":"10.3928\/1081597X-20160524-01","article-title":"Influence of pachymetry and intraocular pressure on dynamic corneal response parameters in healthy patients","volume":"32","author":"Vinciguerra","year":"","journal-title":"J. Refract. Surg."}],"container-title":["Frontiers in Bioengineering and Biotechnology"],"original-title":[],"link":[{"URL":"https:\/\/www.frontiersin.org\/articles\/10.3389\/fbioe.2023.1158299\/full","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,8,4]],"date-time":"2023-08-04T06:43:34Z","timestamp":1691131414000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.frontiersin.org\/articles\/10.3389\/fbioe.2023.1158299\/full"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2023,8,4]]},"references-count":30,"alternative-id":["10.3389\/fbioe.2023.1158299"],"URL":"https:\/\/doi.org\/10.3389\/fbioe.2023.1158299","relation":{},"ISSN":["2296-4185"],"issn-type":[{"value":"2296-4185","type":"electronic"}],"subject":[],"published":{"date-parts":[[2023,8,4]]},"article-number":"1158299"}}