{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,29]],"date-time":"2026-10-29T23:03:42Z","timestamp":1793315022355,"version":"4.5.0"},"reference-count":75,"publisher":"Frontiers Media SA","license":[{"start":{"date-parts":[[2023,5,11]],"date-time":"2023-05-11T00:00:00Z","timestamp":1683763200000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"funder":[{"DOI":"10.13039\/501100000266","name":"Engineering and Physical Sciences Research Council","doi-asserted-by":"publisher","id":[{"id":"10.13039\/501100000266","id-type":"DOI","asserted-by":"publisher"}]},{"DOI":"10.13039\/501100000266","name":"Engineering and Physical Sciences Research Council","doi-asserted-by":"publisher","id":[{"id":"10.13039\/501100000266","id-type":"DOI","asserted-by":"publisher"}]},{"DOI":"10.13039\/100010665","name":"H2020 Marie Sk\u0142odowska-Curie Actions","doi-asserted-by":"publisher","id":[{"id":"10.13039\/100010665","id-type":"DOI","asserted-by":"publisher"}]}],"content-domain":{"domain":["frontiersin.org"],"crossmark-restriction":true},"short-container-title":["Front. Bioeng. Biotechnol."],"abstract":"<jats:p>\n                    <jats:bold>Introduction:<\/jats:bold>\n                    Patient-specific computational fluid dynamics (CFD) models permit analysis of complex intra-aortic hemodynamics in patients with aortic dissection (AD), where vessel morphology and disease severity are highly individualized. The simulated blood flow regime within these models is sensitive to the prescribed boundary conditions (BCs), so accurate BC selection is fundamental to achieve clinically relevant results.\n                  <\/jats:p>\n                  <jats:p>\n                    <jats:bold>Methods:<\/jats:bold>\n                    This study presents a novel reduced-order computational framework for the iterative flow-based calibration of 3-Element Windkessel Model (3EWM) parameters to generate patient-specific BCs. These parameters were calibrated using time-resolved flow information derived from retrospective four-dimensional flow magnetic resonance imaging (4D Flow-MRI). For a healthy and dissected case, blood flow was then investigated numerically in a fully coupled zero dimensional-three dimensional (0D-3D) numerical framework, where the vessel geometries were reconstructed from medical images. Calibration of the 3EWM parameters was automated and required ~3.5 min per branch.\n                  <\/jats:p>\n                  <jats:p>\n                    <jats:bold>Results:<\/jats:bold>\n                    With prescription of the calibrated BCs, the computed near-wall hemodynamics (time-averaged wall shear stress, oscillatory shear index) and perfusion distribution were consistent with clinical measurements and previous literature, yielding physiologically relevant results. BC calibration was particularly important in the AD case, where the complex flow regime was captured only after BC calibration.\n                  <\/jats:p>\n                  <jats:p>\n                    <jats:bold>Discussion:<\/jats:bold>\n                    This calibration methodology can therefore be applied in clinical cases where branch flow rates are known, for example, via 4D Flow-MRI or ultrasound, to generate patient-specific BCs for CFD models. It is then possible to elucidate, on a case-by-case basis, the highly individualized hemodynamics which occur due to geometric variations in aortic pathology high spatiotemporal resolution through CFD.\n                  <\/jats:p>","DOI":"10.3389\/fbioe.2023.1178483","type":"journal-article","created":{"date-parts":[[2023,5,11]],"date-time":"2023-05-11T07:24:55Z","timestamp":1683789895000},"update-policy":"https:\/\/doi.org\/10.3389\/crossmark-policy","source":"Crossref","is-referenced-by-count":36,"title":["Calibration of patient-specific boundary conditions for coupled CFD models of the aorta derived from 4D Flow-MRI"],"prefix":"10.3389","volume":"11","author":[{"given":"Scott MacDonald","family":"Black","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Craig","family":"Maclean","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Pauline","family":"Hall Barrientos","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Konstantinos","family":"Ritos","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Alistair","family":"McQueen","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Asimina","family":"Kazakidi","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"1965","published-online":{"date-parts":[[2023,5,11]]},"reference":[{"key":"B1","volume-title":"'Numerical modelling of pulse wave propagation in the cardiovascular system: Development, validation and clinical applications","author":"Alastruey","year":"2006"},{"key":"B2","volume-title":"Nektar1D reference manual","author":"Alastruey","year":"2021"},{"key":"B3","volume-title":"Arterial pulse wave haemodynamics","author":"Alastruey","year":"2012"},{"key":"B4","doi-asserted-by":"publisher","DOI":"10.1115\/1.3124648","article-title":"Reynolds-averaged Navier-Stokes equations for turbulence modeling","volume":"62","author":"Alfonsi","year":"2009","journal-title":"Appl. Mech. Rev."},{"key":"B5","doi-asserted-by":"publisher","first-page":"275","DOI":"10.1016\/j.medengphy.2013.11.003","article-title":"Development of a patient-specific simulation tool to analyse aortic dissections: Assessment of mixed patient-specific flow and pressure boundary conditions","volume":"36","author":"Alimohammadi","year":"2014","journal-title":"Med. Eng. Phys."},{"key":"B6","doi-asserted-by":"publisher","first-page":"34","DOI":"10.1186\/s12938-015-0032-6","article-title":"Aortic dissection simulation models for clinical support: Fluid-structure interaction vs. rigid wall models","volume":"14","author":"Alimohammadi","year":"2015","journal-title":"Biomed. Eng. OnLine"},{"key":"B7","doi-asserted-by":"publisher","first-page":"e001158","DOI":"10.1136\/openhrt-2019-001158","article-title":"Clinical use of 4D flow MRI for quantification of aortic regurgitation","volume":"7","author":"Alvarez","year":"2020","journal-title":"Open Heart"},{"key":"B8","doi-asserted-by":"publisher","first-page":"e0166569","DOI":"10.1371\/journal.pone.0166569","article-title":"Interaction between the stress phase angle (SPA) and the oscillatory shear index (OSI) affects endothelial cell gene expression","volume":"11","author":"Amaya","year":"2015","journal-title":"PloS One"},{"key":"B9","volume-title":"Reconstruction and validation of arterial geometries from 4D flow-MRI images: A novel approach","author":"Black","year":"2023"},{"key":"B10","doi-asserted-by":"publisher","first-page":"1529","DOI":"10.1007\/s10554-016-0938-5","article-title":"Comparison of 4D flow and 2D velocity-encoded phase contrast MRI sequences for the evaluation of aortic hemodynamics","volume":"32","author":"Bollache","year":"2016","journal-title":"Int. J. Cardiovasc. Imaging"},{"key":"B11","doi-asserted-by":"publisher","first-page":"45","DOI":"10.1016\/j.medengphy.2019.06.012","article-title":"Patient-specific haemodynamic simulations of complex aortic dissections informed by commonly available clinical datasets","volume":"71","author":"Bonfanti","year":"2019","journal-title":"Med. Eng. Phys."},{"key":"B12","doi-asserted-by":"publisher","first-page":"123","DOI":"10.1016\/j.medengphy.2020.09.014","article-title":"Blood flow simulations in the pulmonary bifurcation in relation to adult patients with repaired tetralogy of Fallot","volume":"85","author":"Boumpouli","year":"2020","journal-title":"Med. Eng. Phys."},{"key":"B13","doi-asserted-by":"publisher","first-page":"703717","DOI":"10.3389\/fcvm.2021.703717","article-title":"Characterization of flow dynamics in the pulmonary bifurcation of patients with repaired tetralogy of fallot: A computational approach","volume":"8","author":"Boumpouli","year":"2021","journal-title":"Front. Cardiovasc. Med."},{"key":"B14","doi-asserted-by":"publisher","first-page":"1174","DOI":"10.1152\/ajpheart.00017.2018","article-title":"Normal patterns of thoracic aortic wall shear stress measured using fourdimensional flow MRI in a large population","volume":"315","author":"Callaghan","year":"2018","journal-title":"Transl. Physiol."},{"key":"B15","doi-asserted-by":"publisher","first-page":"748908","DOI":"10.3389\/fmedt.2021.748908","article-title":"On the role and effects of uncertainties in cardiovascular in silico analyses","volume":"3","author":"Celi","year":"2021","journal-title":"Front. Med. Technol."},{"key":"B16","doi-asserted-by":"publisher","first-page":"65","DOI":"10.1186\/1475-925x-12-65","article-title":"A patient-specific study of type-B aortic dissection: Evaluation of true-false lumen blood exchange","volume":"12","author":"Chen","year":"2013","journal-title":"Biomed. Eng. OnLine"},{"key":"B17","doi-asserted-by":"publisher","first-page":"15128","DOI":"10.1038\/s41598-022-19347-6","article-title":"The impact of 4D-Flow MRI spatial resolution on patient-specific CFD simulations of the thoracic aorta","volume":"12","author":"Cherry","year":"2022","journal-title":"Sci. Rep."},{"key":"B18","doi-asserted-by":"publisher","first-page":"264","DOI":"10.1177\/1358863x15625371","article-title":"Malperfusion syndromes in aortic dissections","volume":"21","author":"Crawford","year":"2016","journal-title":"Vasc. Med."},{"key":"B19","doi-asserted-by":"publisher","first-page":"403","DOI":"10.3978\/j.issn.2225-319X.2014.07.03","article-title":"Role of entry tear size in type B aortic dissection","volume":"3","author":"Evangelista","year":"2014","journal-title":"Ann. Cardiothorac. Surg."},{"key":"B20","doi-asserted-by":"publisher","first-page":"e3516","DOI":"10.1002\/cnm.3516","article-title":"An optimal control approach to determine resistance-type boundary conditions from in-vivo data for cardiovascular simulations","volume":"37","author":"Fevola","year":"2021","journal-title":"Int. J. Numer. Methods Biomed. Eng."},{"key":"B21","doi-asserted-by":"publisher","first-page":"484","DOI":"10.1016\/j.compbiomed.2008.01.012","article-title":"On stent-graft models in thoracic aortic endovascular repair: A computational investigation of the hemodynamic factors","volume":"38","author":"Fung","year":"2008","journal-title":"Comput. Biol. Med."},{"key":"B22","doi-asserted-by":"publisher","first-page":"E90","DOI":"10.1186\/1532-429x-15-s1-e90","article-title":"Comparison of 4D flow and 2D PC MRI blood flow quantification in children and young adults with congenital heart disease","volume":"15","author":"Gabbour","year":"2013","journal-title":"J. Cardiovasc. Magnetic Reson."},{"key":"B23","doi-asserted-by":"publisher","first-page":"46","DOI":"10.1007\/s12572-016-0161-6","article-title":"Computational fluid dynamic simulation of human carotid artery bifurcation based on anatomy and volumetric blood flow rate measured with magnetic resonance imaging","volume":"8","author":"Gharahi","year":"2016","journal-title":"Int. J. Adv. Eng. Sci. Appl. Math."},{"key":"B24","doi-asserted-by":"publisher","first-page":"261","DOI":"10.2174\/1874609812666190226151500","article-title":"Impact of cardiovascular factors on pulse wave velocity and total vascular resistance in different age group patients with cardiovascular disorders","volume":"11","author":"Ghosh","year":"2018","journal-title":"Curr. Aging Sci."},{"key":"B25","first-page":"3421","article-title":"Expert recommendations on the assessment of wall shear stress in human coronary arteries: Existing methodologies, technical considerations, and clinical applications","volume":"40","author":"Gijsen","year":"2019","journal-title":"Eur. Soc. Cardiol."},{"key":"B26","doi-asserted-by":"publisher","first-page":"1496","DOI":"10.1007\/s10439-008-9527-7","article-title":"Outflow boundary conditions for arterial networks with multiple outlets","volume":"36","author":"Grinberg","year":"2008","journal-title":"Ann. Biomed. Eng."},{"key":"B27","doi-asserted-by":"publisher","first-page":"183","DOI":"10.1007\/s10554-021-02359-0","article-title":"Estimated pulse wave velocity (ePWV) as a potential gatekeeper for MRI assessed PWV: A linear and deep neural network based approach in 2254 participants of The Netherlands epidemiology of obesity study","volume":"38","author":"Hout","year":"2022","journal-title":"Int. J. Cardiovasc. Imaging"},{"key":"B28","doi-asserted-by":"publisher","first-page":"103814","DOI":"10.1016\/j.medengphy.2022.103814","article-title":"Patient-specific computational haemodynamics associated with the surgical creation of an arteriovenous fistula","volume":"105","author":"Hyde-Linaker","year":"2022","journal-title":"Med. Eng. Phys."},{"key":"B29","doi-asserted-by":"publisher","first-page":"464","DOI":"10.1002\/jmri.28045","article-title":"Aortic pulse wave velocity evaluated by4D flow MRI across the adult lifespan","volume":"56","author":"Jarvis","year":"2022","journal-title":"J. Magnetic Reson. Imaging"},{"key":"B30","doi-asserted-by":"publisher","first-page":"670841","DOI":"10.3389\/fcvm.2021.670841","article-title":"Hemodynamic abnormalities in the aorta of turner syndrome girls","volume":"8","author":"Johnston","year":"","journal-title":"Front. Cardiovasc. Med."},{"key":"B31","doi-asserted-by":"publisher","first-page":"1","DOI":"10.29245\/2578-3025\/2021\/2.1213","article-title":"Hemodynamics in the aorta and pulmonary arteries of congenital heart disease patients: A mini review","volume":"5","author":"Johnston","year":"","journal-title":"J. Cardiol. Cardiovasc. Sci."},{"key":"B32","doi-asserted-by":"publisher","first-page":"111","DOI":"10.3329\/ganit.v40i2.51314","article-title":"Performance of k-\u03c9 and k-\u03b5 model for blood flow simulation in stenosed artery","volume":"40","author":"Kabir","year":"2020","journal-title":"GANIT J. Bangladesh Math. Soc."},{"key":"B33","doi-asserted-by":"publisher","first-page":"1594","DOI":"10.1098\/rsif.2011.0108","article-title":"Effect of reverse flow on the pattern of wall shear stress near arterial branches","volume":"8","author":"Kazakidi","year":"2011","journal-title":"J. R. Soc. Interface"},{"key":"B34","doi-asserted-by":"publisher","first-page":"539","DOI":"10.1098\/rsif.2008.0323","article-title":"Effect of Reynolds number and flow division on patterns of haemodynamic wall shear stress near branch points in the descending thoracic aorta","volume":"6","author":"Kazakidi","year":"2009","journal-title":"J. R. Soc. Interface"},{"key":"B35","doi-asserted-by":"publisher","first-page":"2153","DOI":"10.1007\/s10439-009-9760-8","article-title":"On coupling a lumped parameter heart model and a three-dimensional finite element aorta model","volume":"37","author":"Kim","year":"2009","journal-title":"Ann. Biomed. Eng."},{"key":"B36","doi-asserted-by":"publisher","first-page":"157","DOI":"10.1007\/s10047-013-0694-4","article-title":"Numerical analysis of blood flow distribution in 4- and 3-branch vascular grafts","volume":"16","author":"Konoura","year":"2013","journal-title":"J. Artif. Organs"},{"key":"B37","doi-asserted-by":"publisher","first-page":"O71","DOI":"10.1186\/1532-429x-13-s1-o71","article-title":"Accuracy of aortic pulse wave velocity assessment with velocity-encoded MRI: Validation in patients with marfan syndrome","volume":"13","author":"Kr\u00f6ner","year":"2011","journal-title":"J. Cardiovasc. Magnetic Reson."},{"key":"B38","first-page":"399","volume-title":"Blood flow in arteries. Annual review of fluid mechanics","author":"Ku","year":"1997"},{"key":"B39","doi-asserted-by":"publisher","first-page":"112","DOI":"10.1137\/s1052623496303470","article-title":"Convergence properties of the Nelder-Mead simplex method in low dimensions","volume":"9","author":"Lagarias","year":"1998","journal-title":"SIAM J. Optim."},{"key":"B40","doi-asserted-by":"publisher","first-page":"0245011","DOI":"10.1115\/1.4038751","article-title":"A Re-engineered software interface and workflow for the open-source SimVascular cardiovascular modeling package","volume":"140","author":"Lan","year":"2018","journal-title":"J. Biomechanical Eng."},{"key":"B41","doi-asserted-by":"publisher","first-page":"9111","DOI":"10.1038\/s41598-018-27249-9","article-title":"Quantitative study of abdominal blood flow patterns in patients with aortic dissection by 4-dimensional flow MRI","volume":"8","author":"Liu","year":"2018","journal-title":"Sci. Rep."},{"key":"B42","doi-asserted-by":"publisher","first-page":"88","DOI":"10.1016\/j.cpc.2015.07.016","article-title":"CFD study of jet impingement test erosion using Ansys Fluent\u00ae and OpenFOAM","volume":"12","author":"L\u00f3pez","year":"2015","journal-title":"Comput. Phys. Commun."},{"key":"B43","doi-asserted-by":"publisher","first-page":"66","DOI":"10.1186\/s12938-018-0497-1","article-title":"The effect of inlet and outlet boundary conditions in image-based CFD modeling of aortic flow","volume":"17","author":"Madhavan","year":"2018","journal-title":"Biomed. Eng. Online"},{"key":"B44","doi-asserted-by":"publisher","first-page":"1586","DOI":"10.1093\/ejcts\/ezv480","article-title":"Re: Blood flow analysis of the aortic arch using computational fluid dynamics","volume":"49","author":"Markl","year":"2016","journal-title":"Eur. J. Cardio-Thoracic Surg."},{"key":"B45","doi-asserted-by":"publisher","first-page":"1575","DOI":"10.1002\/mrm.22353","article-title":"Estimation of global aortic pulse wave velocity by flow-sensitive 4D MRI","volume":"63","author":"Markl","year":"2010","journal-title":"Magnetic Reson. Med."},{"key":"B46","doi-asserted-by":"publisher","first-page":"1162","DOI":"10.1002\/jmri.22856","article-title":"Analysis of pulse wave velocity in the thoracic aorta by flow-sensitive four-dimensional MRI:reproducibility and correlation with characteristics in patients with aortic atherosclerosis","volume":"35","author":"Markl","year":"2012","journal-title":"J. Magnetic Reson. Imaging"},{"key":"B47","doi-asserted-by":"publisher","first-page":"1719","DOI":"10.1093\/eurheartj\/eht565","article-title":"Central blood pressure: Current evidence and clinical importance","volume":"35","author":"McEniery","year":"2014","journal-title":"Eur. Heart J."},{"key":"B48","doi-asserted-by":"publisher","first-page":"105685","DOI":"10.1016\/j.jstrokecerebrovasdis.2021.105685","article-title":"Inflow hemodynamics of intracranial aneurysms: A comparison of computational fluid dynamics and 4D flow magnetic resonance imaging","volume":"30","author":"Misaki","year":"2021","journal-title":"J. Stroke Cerebrovasc. Dis."},{"key":"B49","doi-asserted-by":"publisher","first-page":"63","DOI":"10.1016\/j.jcp.2012.07.035","article-title":"A modular numerical method for implicit 0D\/3D coupling in cardiovascular finite element simulations","volume":"244","author":"Moghadam","year":"2013","journal-title":"J. Comput. Phys."},{"key":"B50","doi-asserted-by":"publisher","first-page":"158","DOI":"10.1016\/j.jbiomech.2016.11.038","article-title":"Approaches for treatment of aortic arch aneurysm, a numerical study","volume":"50","author":"Nardi","year":"2017","journal-title":"J. Biomechanics"},{"key":"B51","doi-asserted-by":"publisher","first-page":"71","DOI":"10.1186\/s12968-015-0172-7","article-title":"Cardiovascular magnetic resonance phase contrast imaging","volume":"17","author":"Nayak","year":"2015","journal-title":"J. Cardiovasc. Magnetic Reson."},{"key":"B52","doi-asserted-by":"publisher","first-page":"524","DOI":"10.1161\/hypertensionaha.116.08749","article-title":"Aortic arch pulse wave velocity assessed by magnetic resonance imaging as a predictor of incident cardiovascular events","volume":"70","author":"Ohyama","year":"2017","journal-title":"Hypertension"},{"key":"B53","doi-asserted-by":"publisher","first-page":"242","DOI":"10.1093\/cvr\/cvt044","article-title":"Does low and oscillatory wall shear stress correlate spatially with early atherosclerosis? A systematic review","volume":"99","author":"Peiffer","year":"2013","journal-title":"Cardiovasc. Res."},{"key":"B54","doi-asserted-by":"publisher","first-page":"15","DOI":"10.1016\/j.jbiomech.2017.06.005","article-title":"On the choice of outlet boundary conditions for patient-specific analysis of aortic flow using computational fluid dynamics","volume":"60","author":"Pirola","year":"2017","journal-title":"J. Biomechanics"},{"key":"B55","doi-asserted-by":"publisher","first-page":"e3134","DOI":"10.1002\/cnm.3134","article-title":"Patient-specific CFD modelling in the thoracic aorta withPC-MRI\u2013based boundary conditions: A least-squarethree-element Windkessel approach","volume":"34","author":"Romarowski","year":"2018","journal-title":"Numer. Methods Biomed. Eng."},{"key":"B56","doi-asserted-by":"publisher","first-page":"464","DOI":"10.1016\/j.jvs.2012.07.008","article-title":"An in vitro phantom study on the influence of tear size and configuration on the hemodynamics of the lumina in chronic type B aortic dissections","volume":"57","author":"Rudenick","year":"2013","journal-title":"J. Vasc. Surg."},{"key":"B80","doi-asserted-by":"publisher","first-page":"796","DOI":"10.1161\/HYPERTENSIONAHA.118.11212","article-title":"Interaction between hypertension and arterial stiffness","volume":"72","author":"Safar","year":"2018","journal-title":"Hypertension"},{"key":"B57","doi-asserted-by":"publisher","first-page":"378","DOI":"10.1115\/1.1487357","article-title":"Unsteady and three-dimensional simulation of blood flow in the human aortic arch","volume":"124","author":"Shahcheraghi","year":"2002","journal-title":"Trans. ASME"},{"key":"B58","doi-asserted-by":"publisher","first-page":"1001","DOI":"10.1007\/s10439-022-02980-7","article-title":"Enhanced 4D flow MRI-based CFD with adaptive mesh refinement for flow dynamics assessment in coarctation of the aorta","volume":"50","author":"Shahid","year":"2022","journal-title":"Ann. Biomed. Eng."},{"key":"B59","doi-asserted-by":"publisher","first-page":"27","DOI":"10.1186\/s12968-019-0530-y","article-title":"Quantification of aortic pulse wave velocity from a population based cohort: A fully automatic method","volume":"21","author":"Shahzad","year":"2019","journal-title":"J. Cardiovasc. Magnetic Reson."},{"key":"B60","doi-asserted-by":"publisher","first-page":"33","DOI":"10.1186\/1475-925x-10-33","article-title":"Review of zero-D and 1-D models of blood flow in the cardiovascular system","volume":"10","author":"Shi","year":"2011","journal-title":"Biomed. Eng. Online"},{"key":"B61","doi-asserted-by":"publisher","first-page":"935","DOI":"10.1046\/j.1525-1594.2003.00025.x","article-title":"Studies of turbulence models in a computational fluid dynamics model of a blood pump","volume":"27","author":"Song","year":"2003","journal-title":"Artif. Organs"},{"key":"B62","doi-asserted-by":"publisher","first-page":"2635","DOI":"10.1007\/s10439-010-0011-9","article-title":"Tuning multidomain hemodynamic simulations to match physiological measurements","volume":"38","author":"Spilker","year":"2010","journal-title":"Ann. Biomed. Eng."},{"key":"B63","doi-asserted-by":"publisher","first-page":"173","DOI":"10.3978\/j.issn.2223-3652.2014.01.02","article-title":"4D flow imaging with MRI","volume":"4","author":"Stankovic","year":"2014","journal-title":"Cardiovasc. Diagnosis Ther."},{"key":"B64","doi-asserted-by":"publisher","first-page":"827","DOI":"10.1016\/j.jbiomech.2010.12.014","article-title":"Investigation of hemodynamics in the development of dissecting aneurysm within patient-specific dissecting aneurismal aortas using computational fluid dynamics (CFD) simulations","volume":"44","author":"Tse","year":"2011","journal-title":"J. Biomechanics"},{"key":"B65","doi-asserted-by":"publisher","first-page":"2834","DOI":"10.1098\/rsif.2012.0295","article-title":"Haemodynamics in the mouse aortic arch computed from MRI-derived velocities at the aortic root","volume":"9","author":"Van-Doormaal","year":"2012","journal-title":"J. R. Soc. Interface"},{"key":"B66","doi-asserted-by":"publisher","first-page":"3776","DOI":"10.1016\/j.cma.2005.04.014","article-title":"Outflow boundary conditions for three-dimensional finite element modeling of blood flow and pressure in arteries","volume":"195","author":"Vignon-Clementel","year":"2006","journal-title":"Comput. Methods Appl. Mech. Eng."},{"key":"B67","doi-asserted-by":"publisher","first-page":"131","DOI":"10.1007\/s11517-008-0359-2","article-title":"The arterial Windkessel","volume":"47","author":"Westerhof","year":"2009","journal-title":"Med. Biol. Eng. Comput."},{"key":"B68","doi-asserted-by":"publisher","first-page":"546","DOI":"10.1111\/j.1365-2125.2011.04129.x","article-title":"Pulse pressure amplification in relation to body fatness","volume":"73","author":"Wykretowicz","year":"2012","journal-title":"Br. J. Clin. Pharmacol."},{"key":"B69","doi-asserted-by":"publisher","first-page":"204","DOI":"10.1002\/cnm.2598","article-title":"A systematic comparison between 1-D and 3-D hemodynamics in compliant arterial models","volume":"30","author":"Xiao","year":"2014","journal-title":"Int. J. Numer. Methods Biomed. Eng."},{"key":"B70","volume-title":"Simulation of 3D blood flow in the full systemic arterial tree and computational frameworks for efficient parameter estimation","author":"Xiao","year":"2014"},{"key":"B71","doi-asserted-by":"publisher","first-page":"927","DOI":"10.1007\/s10439-018-2012-z","article-title":"Coupled morphological\u2013hemodynamic computational analysis of type B aortic dissection: A longitudinal study","volume":"46","author":"Xu","year":"2018","journal-title":"Ann. Biomed. Eng."},{"key":"B73","doi-asserted-by":"publisher","first-page":"33","DOI":"10.1259\/bjr\/59367266","article-title":"Analysis of haemodynamic factors involved in carotid atherosclerosis using computational fluid dynamics","volume":"82","author":"Zaman","year":"2009","journal-title":"Br. J. Radiology"},{"key":"B74","doi-asserted-by":"publisher","first-page":"1303","DOI":"10.1016\/0021-9290(92)90285-9","article-title":"Relation between diameter and flow in major branches of the arch of the aorta","volume":"25","author":"Zamir","year":"1992","journal-title":"J. Biomechanics"},{"key":"B75","doi-asserted-by":"publisher","first-page":"41","DOI":"10.1186\/s12938-019-0660-3","article-title":"A review on low dimensional physics based models of systemic arteries: Application to estimation of central aortic pressure","volume":"18","author":"Zhou","year":"2019","journal-title":"Biomed. Eng. Online"}],"container-title":["Frontiers in Bioengineering and Biotechnology"],"original-title":[],"link":[{"URL":"https:\/\/www.frontiersin.org\/articles\/10.3389\/fbioe.2023.1178483\/full","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,5,11]],"date-time":"2023-05-11T07:25:36Z","timestamp":1683789936000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.frontiersin.org\/articles\/10.3389\/fbioe.2023.1178483\/full"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2023,5,11]]},"references-count":75,"alternative-id":["10.3389\/fbioe.2023.1178483"],"URL":"https:\/\/doi.org\/10.3389\/fbioe.2023.1178483","relation":{},"ISSN":["2296-4185"],"issn-type":[{"value":"2296-4185","type":"electronic"}],"subject":[],"published":{"date-parts":[[2023,5,11]]},"article-number":"1178483"}}