{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,3,15]],"date-time":"2026-03-15T21:27:26Z","timestamp":1773610046427,"version":"3.50.1"},"reference-count":55,"publisher":"Frontiers Media SA","license":[{"start":{"date-parts":[[2023,10,2]],"date-time":"2023-10-02T00:00:00Z","timestamp":1696204800000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"content-domain":{"domain":["frontiersin.org"],"crossmark-restriction":true},"short-container-title":["Front. Bioeng. Biotechnol."],"abstract":"<jats:p><jats:bold>Introduction:<\/jats:bold> Independent augmentation technology based on reinforcing devices has been reported to signifi-cantly reduce the elongation behavior of graft and improve knee stability after anterior cruciate ligament reconstruction (ACLR). Using biodegradable devices could reduce the risk of severe inflammatory reactions due to particle accumulation from foreign bodies. Given the limitations of the mechanical properties of biodegradable materials, partially biodegradable composite devices may offer a compromise strategy.<\/jats:p><jats:p><jats:bold>Methods:<\/jats:bold> Three types of partially absorbable core-sheath sutures, including low-absorbable cord (LA-C), medium-absorbable cord (MA-C) and high-absorbable cord (HA-C), were braided using unabsorbable ultra-high molecular weight polyethylene (UHMWPE) yarn and absorbable polydioxanone (PDO) monofil-ament bundle based on the desired configuration. The feasibility of these partially absorbable cords were verified by biomechanical testing, material degradation testing, and cell experiments, all performed <jats:italic>in vitro<\/jats:italic>.<\/jats:p><jats:p><jats:bold>Results:<\/jats:bold> Reinforcement of an 8\u00a0mm graft with the cords decreased dynamic elongation by 24%\u201376%, was positively related to dynamic stiffness, and increased the failure load by 44%\u2013105%, during which LA-C showed maximum enhancement. Human ligament-derived fibroblasts showed good proliferation and vitality on each cord over 2\u00a0weeks and aligned themselves in the direction of the fibers, especially the UHMWPE portion.<\/jats:p><jats:p><jats:bold>Discussion:<\/jats:bold> This study supports the potential of partially degradable UHMWPE\/PDO cords, particularly LA-C, for graft protection. Nervertheless, a higher proportion of biodegradable material results in lower stiffness, which may impair the protective and lead to mechanical instability during degradation.<\/jats:p>","DOI":"10.3389\/fbioe.2023.1216937","type":"journal-article","created":{"date-parts":[[2023,10,2]],"date-time":"2023-10-02T15:52:10Z","timestamp":1696261930000},"update-policy":"https:\/\/doi.org\/10.3389\/crossmark-policy","source":"Crossref","is-referenced-by-count":1,"title":["Evaluation of biomechanical properties and biocompatibility: are partially absorbable cords eligible for anterior cruciate ligament reconstruction?"],"prefix":"10.3389","volume":"11","author":[{"given":"Fei","family":"Xu","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Yanlin","family":"Li","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Yang","family":"Yu","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Guoliang","family":"Wang","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Guofeng","family":"Cai","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"1965","published-online":{"date-parts":[[2023,10,2]]},"reference":[{"key":"B1","doi-asserted-by":"publisher","first-page":"410","DOI":"10.1177\/0885328217720641","article-title":"Synthetic sutures: clinical evaluation and future developments","volume":"32","author":"Abhari","year":"2017","journal-title":"J. Biomater. Appl."},{"key":"B2","doi-asserted-by":"publisher","first-page":"596","DOI":"10.1136\/bjsm.2010.076364","article-title":"Return to sport following anterior cruciate ligament reconstruction surgery: A systematic review and meta-analysis of the state of play","volume":"45","author":"Ardern","year":"2011","journal-title":"Br. J. Sports Med."},{"key":"B3","doi-asserted-by":"publisher","first-page":"88","DOI":"10.1016\/j.arthro.2021.09.032","article-title":"Independent suture augmentation with all-inside anterior cruciate ligament reconstruction reduces peak loads on soft-tissue graft. A biomechanical full-construct study","volume":"38","author":"Bachmaier","year":"2022","journal-title":"Arthroscopy"},{"key":"B4","doi-asserted-by":"publisher","first-page":"490","DOI":"10.1016\/j.arthro.2017.10.037","article-title":"Independent suture tape reinforcement of small and standard diameter grafts for anterior cruciate ligament reconstruction: A biomechanical full construct model","volume":"34","author":"Bachmaier","year":"2018","journal-title":"Arthroscopy"},{"key":"B5","doi-asserted-by":"publisher","first-page":"957","DOI":"10.1016\/j.arthro.2014.11.032","article-title":"Synthetic devices for reconstructive surgery of the cruciate ligaments: A systematic review","volume":"31","author":"Batty","year":"2015","journal-title":"Arthroscopy"},{"key":"B6","doi-asserted-by":"publisher","first-page":"2536","DOI":"10.1177\/0363546511422349","article-title":"Accelerated versus nonaccelerated rehabilitation after anterior cruciate ligament reconstruction: A prospective, randomized, double-blind investigation evaluating knee joint laxity using roentgen stereophotogrammetric analysis","volume":"39","author":"Beynnon","year":"2011","journal-title":"Am. J. Sports Med."},{"key":"B7","doi-asserted-by":"publisher","first-page":"2114","DOI":"10.1016\/j.arthro.2019.01.054","article-title":"Suture augmented versus standard anterior cruciate ligament reconstruction: A matched comparative analysis","volume":"35","author":"Bodendorfer","year":"2019","journal-title":"Arthroscopy"},{"key":"B8","doi-asserted-by":"publisher","first-page":"91","DOI":"10.1007\/s00264-003-0515-0","article-title":"Augmentation in anterior cruciate ligament reconstruction-a histological and biomechanical study on goats","volume":"28","author":"Buma","year":"2004","journal-title":"Int. Orthop."},{"key":"B9","doi-asserted-by":"publisher","first-page":"2476","DOI":"10.1177\/0363546511402662","article-title":"The \"ligamentization\" process in anterior cruciate ligament reconstruction: what happens to the human graft? A systematic review of the literature","volume":"39","author":"Claes","year":"2011","journal-title":"Am. J. Sports Med."},{"key":"B10","doi-asserted-by":"publisher","first-page":"704","DOI":"10.1055\/s-0036-1597618","article-title":"A canine arthroscopic anterior cruciate ligament reconstruction model for study of synthetic augmentation of tendon allografts","volume":"30","author":"Cook","year":"2017","journal-title":"J. Knee Surg."},{"key":"B11","doi-asserted-by":"publisher","first-page":"349","DOI":"10.1016\/j.pmrj.2017.09.005","article-title":"Accelerated return to sport after anterior cruciate ligament reconstruction and early knee osteoarthritis features at 1 Year: an exploratory study","volume":"10","author":"Culvenor","year":"2018","journal-title":"Pm R."},{"key":"B12","doi-asserted-by":"publisher","first-page":"217","DOI":"10.3109\/17453679008993504","article-title":"Goretex prosthetic ligament vs. Kennedy ligament augmentation device in anterior cruciate ligament reconstruction. A prospective randomized 3-year follow-up of 41 cases","volume":"61","author":"Dahlstedt","year":"1990","journal-title":"Acta Orthop. Scand."},{"key":"B13","doi-asserted-by":"publisher","first-page":"162","DOI":"10.1115\/1.1351889","article-title":"Comparison of viscoelastic, structural, and material properties of double-looped anterior cruciate ligament grafts made from bovine digital extensor and human hamstring tendons","volume":"123","author":"Donahue","year":"2001","journal-title":"J. Biomech. Eng."},{"key":"B14","doi-asserted-by":"publisher","first-page":"697","DOI":"10.1002\/jbm.b.10054","article-title":"Control of material stiffness during degradation for constructs made of absorbable polymer fibers","volume":"67","author":"D\u00fcrselen","year":"2003","journal-title":"J. Biomed. Mater Res. B Appl. Biomater."},{"key":"B15","doi-asserted-by":"publisher","first-page":"265","DOI":"10.1002\/jbm.b.30381","article-title":"Biological response to a new composite polymer augmentation device used for cruciate ligament reconstruction","volume":"76","author":"D\u00fcrselen","year":"2006","journal-title":"J. Biomed. Mater Res. B Appl. Biomater."},{"key":"B16","doi-asserted-by":"publisher","first-page":"2073","DOI":"10.1016\/j.arthro.2021.12.036","article-title":"Suture tape augmentation of anterior cruciate ligament reconstruction increases biomechanical stability: A scoping review of biomechanical, animal, and clinical studies","volume":"38","author":"Eam","year":"2022","journal-title":"Arthroscopy"},{"key":"B17","doi-asserted-by":"publisher","first-page":"197","DOI":"10.1016\/s0749-8063(98)70041-6","article-title":"Revascularization and ligamentization of autogenous anterior cruciate ligament grafts in humans","volume":"14","author":"Falconiero","year":"1998","journal-title":"Arthroscopy"},{"key":"B18","doi-asserted-by":"publisher","first-page":"490","DOI":"10.1016\/j.arthro.2019.11.129","article-title":"Editorial commentary: will suture tape augmentation prove to Be the answer to anterior cruciate ligament graft remodeling, ultimate strength, and safe return to play?","volume":"36","author":"Frangie","year":"2020","journal-title":"Arthroscopy"},{"key":"B19","first-page":"143","article-title":"Tendon-to-bone healing of a semitendinosus tendon autograft used for ACL reconstruction in a sheep model","volume":"13","author":"Goradia","year":"2000","journal-title":"Am. J. Knee Surg."},{"key":"B20","doi-asserted-by":"publisher","first-page":"2884","DOI":"10.1007\/s00167-015-3530-y","article-title":"Lack of consensus regarding pretensioning and preconditioning protocols for soft tissue graft reconstruction of the anterior cruciate ligament","volume":"24","author":"Jisa","year":"2016","journal-title":"Knee Surg. Sports Traumatol. Arthrosc."},{"key":"B21","doi-asserted-by":"publisher","first-page":"232596712210855","DOI":"10.1177\/23259671221085577","article-title":"Outcomes after hamstring ACL reconstruction with suture tape reinforcement in adolescent athletes","volume":"10","author":"Kitchen","year":"2022","journal-title":"Orthop. J. Sports Med."},{"key":"B22","doi-asserted-by":"publisher","first-page":"e57","DOI":"10.1016\/j.asmr.2020.08.009","article-title":"The use of suture augmentation for graft protection in ACL reconstruction: A biomechanical study in porcine knees","volume":"3","author":"Lai","year":"2021","journal-title":"Arthrosc. Sports Med. Rehabil."},{"key":"B23","doi-asserted-by":"publisher","first-page":"982","DOI":"10.1002\/jbm.a.34759","article-title":"Biodegradable weft-knitted intestinal stents: fabrication and physical changes investigation in vitro degradation","volume":"102","author":"Li","year":"2014","journal-title":"J. Biomed. Mater Res. A"},{"key":"B24","doi-asserted-by":"publisher","first-page":"938","DOI":"10.3390\/polym14050938","article-title":"A complex in vitro degradation study on polydioxanone biliary stents during a clinically relevant period with the focus on Raman spectroscopy validation","volume":"14","author":"Loskot","year":"2022","journal-title":"Polym. (Basel)"},{"key":"B25","doi-asserted-by":"publisher","first-page":"526","DOI":"10.1016\/j.arthro.2011.11.024","article-title":"Graft size and patient age are predictors of early revision after anterior cruciate ligament reconstruction with hamstring autograft","volume":"28","author":"Magnussen","year":"2012","journal-title":"Arthroscopy"},{"key":"B26","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1155\/2018\/4657824","article-title":"A review on Biomechanics of anterior cruciate ligament and materials for reconstruction","volume":"2018","author":"Marieswaran","year":"2018","journal-title":"Appl. Bionics Biomech."},{"key":"B27","doi-asserted-by":"publisher","first-page":"1948","DOI":"10.1016\/j.arthro.2013.08.025","article-title":"The influence of hamstring autograft size on patient-reported outcomes and risk of revision after anterior cruciate ligament reconstruction: A multicenter orthopaedic outcomes network (MOON) cohort study","volume":"29","author":"Mariscalco","year":"2013","journal-title":"Arthroscopy"},{"key":"B28","doi-asserted-by":"publisher","first-page":"3335","DOI":"10.1016\/j.arthro.2021.04.053","article-title":"Suture tape augmentation improves the biomechanical performance of bone-patellar tendon-bone grafts used for anterior cruciate ligament reconstruction","volume":"37","author":"Matava","year":"2021","journal-title":"Arthroscopy"},{"key":"B29","doi-asserted-by":"publisher","first-page":"224","DOI":"10.1007\/s00167-007-0474-x","article-title":"Biological failure\" of the anterior cruciate ligament graft","volume":"16","author":"M\u00e9n\u00e9trey","year":"2008","journal-title":"Knee Surg. Sports Traumatol. Arthrosc."},{"key":"B30","doi-asserted-by":"publisher","first-page":"1003","DOI":"10.1136\/bjsports-2016-096274","article-title":"What's my risk of sustaining an ACL injury while playing sports?\" A systematic review with meta-analysis","volume":"53","author":"Montalvo","year":"2019","journal-title":"Br. J. Sports Med."},{"key":"B31","doi-asserted-by":"publisher","first-page":"481","DOI":"10.1016\/j.arthro.2019.06.036","article-title":"Independent suture tape reinforcement of tripled smaller-diameter and quadrupled grafts for anterior cruciate ligament reconstruction with tibial screw fixation: A biomechanical full construct model","volume":"36","author":"Noonan","year":"2020","journal-title":"Arthroscopy"},{"key":"B32","doi-asserted-by":"publisher","first-page":"148","DOI":"10.1016\/j.actbio.2017.10.010","article-title":"Modulating microfibrillar alignment and growth factor stimulation to regulate mesenchymal stem cell differentiation","volume":"64","author":"Olvera","year":"2017","journal-title":"Acta Biomater."},{"key":"B33","doi-asserted-by":"publisher","first-page":"609","DOI":"10.1016\/j.arthro.2020.09.002","article-title":"Hamstring autograft anterior cruciate ligament reconstruction using an all-inside technique with and without independent suture tape reinforcement","volume":"37","author":"Parkes","year":"2021","journal-title":"Arthroscopy"},{"key":"B34","doi-asserted-by":"publisher","first-page":"2109","DOI":"10.1007\/s00167-013-2636-3","article-title":"Long-term results of a randomized study on anterior cruciate ligament reconstruction with or without a synthetic degradable augmentation device to support the autograft","volume":"22","author":"Peterson","year":"2014","journal-title":"Knee Surg. Sports Traumatol. Arthrosc."},{"key":"B35","doi-asserted-by":"publisher","first-page":"e582","DOI":"10.3928\/01477447-20150701-55","article-title":"Pretensioning of soft tissue grafts in anterior cruciate ligament reconstruction","volume":"38","author":"Pilia","year":"2015","journal-title":"Orthopedics"},{"key":"B36","doi-asserted-by":"publisher","first-page":"188","DOI":"10.1016\/j.polymertesting.2018.05.014","article-title":"Using an industrial braiding machine to upscale the production and modulate the design of electrospun medical yarns","volume":"69","author":"Rea","year":"2018","journal-title":"Polym. Test."},{"key":"B37","doi-asserted-by":"publisher","first-page":"470","DOI":"10.1016\/j.arthro.2009.08.019","article-title":"Ligamentization of tendon grafts treated with an endogenous preparation rich in growth factors: gross morphology and histology","volume":"26","author":"S\u00e1nchez","year":"2010","journal-title":"Arthroscopy"},{"key":"B38","doi-asserted-by":"publisher","first-page":"132","DOI":"10.1002\/jor.22185","article-title":"Bending and abrasion fatigue of common suture materials used in arthroscopic and open orthopedic surgery","volume":"31","author":"Savage","year":"2013","journal-title":"J. Orthop. Res."},{"key":"B39","doi-asserted-by":"publisher","first-page":"112414","DOI":"10.1016\/j.msec.2021.112414","article-title":"Early development of a polycaprolactone electrospun augment for anterior cruciate ligament reconstruction","volume":"129","author":"Savi\u0107","year":"2021","journal-title":"Mater Sci. Eng. C Mater Biol. Appl."},{"key":"B40","doi-asserted-by":"publisher","first-page":"834","DOI":"10.1007\/s00167-008-0560-8","article-title":"Graft remodeling and ligamentization after cruciate ligament reconstruction","volume":"16","author":"Scheffler","year":"2008","journal-title":"Knee Surg. Sports Traumatol. Arthrosc."},{"key":"B41","doi-asserted-by":"publisher","first-page":"23","DOI":"10.1186\/s12951-019-0556-1","article-title":"Biodegradable polymer nanocomposites for ligament\/tendon tissue engineering","volume":"18","author":"Silva","year":"2020","journal-title":"J. Nanobiotechnology"},{"key":"B42","doi-asserted-by":"publisher","first-page":"232596711881160","DOI":"10.1177\/2325967118811604","article-title":"Foreign body reaction associated with artificial LARS ligaments: A retrieval study","volume":"6","author":"Sinagra","year":"2018","journal-title":"Orthop. J. Sports Med."},{"key":"B43","doi-asserted-by":"publisher","first-page":"525","DOI":"10.1055\/s-0038-1655765","article-title":"Intra-Articular biocompatibility of multistranded, long-chain polyethylene suture tape in a canine ACL model","volume":"32","author":"Smith","year":"2019","journal-title":"J. Knee Surg."},{"key":"B44","doi-asserted-by":"publisher","first-page":"1047","DOI":"10.1055\/s-0039-1692649","article-title":"Independent suture tape internal brace reinforcement of bone-patellar tendon-bone allografts: biomechanical assessment in a full-ACL reconstruction laboratory model","volume":"33","author":"Smith","year":"","journal-title":"J. Knee Surg."},{"key":"B45","doi-asserted-by":"publisher","first-page":"1256","DOI":"10.1055\/s-0039-1695040","article-title":"Patellar bone-tendon-bone autografts versus quadriceps tendon allograft with synthetic augmentation in a canine model","volume":"33","author":"Smith","year":"","journal-title":"J. Knee Surg."},{"key":"B46","doi-asserted-by":"publisher","first-page":"1238","DOI":"10.1302\/0301-620x.101b10.bjj-2018-1282.r2","article-title":"In vivo assessment of high-molecular-weight polyethylene core suture tape for intra-articular ligament reconstruction: an animal study","author":"Soreide","year":"2019","journal-title":"Bone Jt. J."},{"key":"B47","doi-asserted-by":"publisher","first-page":"478","DOI":"10.1016\/j.jbiomech.2012.10.031","article-title":"In vivo measurement of ACL length and relative strain during walking","volume":"46","author":"Taylor","year":"2013","journal-title":"J. Biomech."},{"key":"B48","doi-asserted-by":"publisher","first-page":"176","DOI":"10.1016\/s0268-0033(99)00063-7","article-title":"Cruciate ligament forces in the human knee during rehabilitation exercises","volume":"15","author":"Toutoungi","year":"2000","journal-title":"Clin. Biomech. (Bristol, Avon)"},{"key":"B49","doi-asserted-by":"publisher","first-page":"e378","DOI":"10.7759\/cureus.378","article-title":"Current trends in anterior cruciate ligament reconstruction: A review","volume":"7","author":"Vaishya","year":"2015","journal-title":"Cureus"},{"key":"B50","doi-asserted-by":"publisher","first-page":"20","DOI":"10.1186\/s40634-022-00454-2","article-title":"Suture tape reinforcement of hamstring tendon graft reduces postoperative knee laxity after primary ACL reconstruction","volume":"9","author":"von Essen","year":"2022","journal-title":"J. Exp. Orthop."},{"key":"B51","doi-asserted-by":"publisher","first-page":"751","DOI":"10.1177\/03635465010290061401","article-title":"Biomechanical properties and vascularity of an anterior cruciate ligament graft can be predicted by contrast-enhanced magnetic resonance imaging: A two-year study in Sheep<sup\/>","volume":"29","author":"Weiler","year":"2001","journal-title":"Am. J. Sports Med."},{"key":"B52","doi-asserted-by":"publisher","first-page":"1861","DOI":"10.1177\/0363546515621554","article-title":"Risk of secondary injury in younger athletes after anterior cruciate ligament reconstruction: A systematic review and meta-analysis","volume":"44","author":"Wiggins","year":"2016","journal-title":"Am. J. Sports Med."},{"key":"B53","doi-asserted-by":"publisher","first-page":"1101","DOI":"10.1016\/j.otsr.2019.06.007","article-title":"Biomechanical comparison of different tendon suturing techniques for three-stranded all-inside anterior cruciate ligament grafts","volume":"105","author":"Yoo","year":"2019","journal-title":"Orthop. Traumatol. Surg. Res."},{"key":"B54","doi-asserted-by":"publisher","first-page":"354","DOI":"10.5694\/mja17.00974","article-title":"Increasing rates of anterior cruciate ligament reconstruction in young Australians, 2000-2015","volume":"208","author":"Zbrojkiewicz","year":"2018","journal-title":"Med. J. Aust."},{"key":"B55","doi-asserted-by":"publisher","first-page":"792","DOI":"10.1002\/jbm.b.30319","article-title":"Mechanical properties and in vitro degradation of bioresorbable fibers and expandable fiber-based stents","volume":"74","author":"Zilberman","year":"2005","journal-title":"J. Biomed. Mater Res. B Appl. Biomater."}],"container-title":["Frontiers in Bioengineering and Biotechnology"],"original-title":[],"link":[{"URL":"https:\/\/www.frontiersin.org\/articles\/10.3389\/fbioe.2023.1216937\/full","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,10,2]],"date-time":"2023-10-02T15:52:14Z","timestamp":1696261934000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.frontiersin.org\/articles\/10.3389\/fbioe.2023.1216937\/full"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2023,10,2]]},"references-count":55,"alternative-id":["10.3389\/fbioe.2023.1216937"],"URL":"https:\/\/doi.org\/10.3389\/fbioe.2023.1216937","relation":{},"ISSN":["2296-4185"],"issn-type":[{"value":"2296-4185","type":"electronic"}],"subject":[],"published":{"date-parts":[[2023,10,2]]},"article-number":"1216937"}}