{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,5,9]],"date-time":"2026-05-09T01:32:02Z","timestamp":1778290322179,"version":"3.51.4"},"reference-count":15,"publisher":"Frontiers Media SA","license":[{"start":{"date-parts":[[2023,9,12]],"date-time":"2023-09-12T00:00:00Z","timestamp":1694476800000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"content-domain":{"domain":["frontiersin.org"],"crossmark-restriction":true},"short-container-title":["Front. Bioeng. Biotechnol."],"abstract":"<jats:p><jats:bold>Objective:<\/jats:bold> By assessing a case of ankylosing spondylitis (AS) after thoracic lumbar protrusion deformity in a digital model and verifying its effectiveness after surgery for orthopaedic surgery process simulation, a finite element model was established for biomechanical experiments.<\/jats:p><jats:p><jats:bold>Method:<\/jats:bold> A 56-year-old patient with AS underwent preoperative thoracic lumbar spine computed tomography. The data were reconstructed using MIMICS16.0 software and modelled to design and measure the nailing parameters. A three-dimensional model was established using ANSYS14.0 software, and the actual surgical procedure was simulated using biomechanical experiments. The model was verified by comparing the X-ray films obtained from patients during preoperative forward bending, stretching and lateral flexion, with the model further tested using the Hueter-Volkmann principle.<\/jats:p><jats:p><jats:bold>Result:<\/jats:bold> On comparing the measurements across three different load cases (forward bending, after stretching and lateral flexion) in patients with AS after thoracic lumbar protrusion deformity and the original X-ray images, no difference was found between the model of deformation and real patient movement displacement across the vertebral body. On simulating the stress distribution, the measured T10-L4 vertebral body stress values at every point in the injured vertebrae were, on the whole, directed at both the upper and lower ends and exhibited a decreasing trend, and the stress distribution gradually decreased from the injured vertebrae (T12 and L1) to the upper and lower ends.<\/jats:p><jats:p><jats:bold>Conclusion:<\/jats:bold> The accuracy of the research model is high, the geometric similarity is good and relevant applied anatomy can be undertaken using the model parameter measurement. This study provides a successful example of the application of digital technology in the field of spinal deformity and a novel idea for the treatment of AS-related kyphosis.<\/jats:p>","DOI":"10.3389\/fbioe.2023.1220102","type":"journal-article","created":{"date-parts":[[2023,9,13]],"date-time":"2023-09-13T06:37:45Z","timestamp":1694587065000},"update-policy":"https:\/\/doi.org\/10.3389\/crossmark-policy","source":"Crossref","is-referenced-by-count":2,"title":["A case report on digital preoperative design, clinical application and finite element analysis for a patient with ankylosing spondylitis kyphosis"],"prefix":"10.3389","volume":"11","author":[{"given":"Lei","family":"Zhu","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Chi","family":"Zhang","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Li","family":"Peng","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Zifei","family":"Cheng","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Xiuwen","family":"Liang","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"1965","published-online":{"date-parts":[[2023,9,12]]},"reference":[{"key":"B1","doi-asserted-by":"publisher","first-page":"816","DOI":"10.14245\/ns.2142596.298","article-title":"Multiple-rod constructs do not reduce pseudarthrosis and rod fracture after pedicle subtraction osteotomy for adult spinal deformity correction but improve quality of life","volume":"18","author":"Bourghli","year":"2021","journal-title":"Neurospine"},{"key":"B2","doi-asserted-by":"publisher","first-page":"1584","DOI":"10.1097\/01.brs.0000170300.17082.49","article-title":"Closing wedge osteotomy versus opening wedge osteotomy in ankylosing spondylitis with thoracolumbar kyphotic deformity","volume":"30","author":"Chang","year":"2005","journal-title":"Spine (Phila Pa 1976)"},{"key":"B3","doi-asserted-by":"publisher","first-page":"6","DOI":"10.3389\/fbioe.2014.00006","article-title":"Connecting mechanics and bone cell activities in the bone remodeling process: an integrated finite element modeling","volume":"2","author":"Hambli","year":"2014","journal-title":"Front. Bioeng. Biotechnol."},{"key":"B4","doi-asserted-by":"publisher","first-page":"12039","DOI":"10.1038\/s41598-019-48539-w","article-title":"Changes in spinal alignment following eXtreme lateral interbody fusion alone in patients with adult spinal deformity using computed tomography","volume":"9","author":"Hiyama","year":"2019","journal-title":"Sci. Rep."},{"key":"B5","doi-asserted-by":"publisher","first-page":"272","DOI":"10.21037\/apm-21-3852","article-title":"Comparison of corrective and clinical effects between SRS-Schwab grade IV osteotomy combined with the interbody fusion cage and pure grade IV osteotomy in the treatment of old thoracolumbar vertebral osteoporotic fractures with kyphosis","volume":"11","author":"Li","year":"2022","journal-title":"Ann. Palliat. Med."},{"key":"B6","doi-asserted-by":"publisher","first-page":"e26374","DOI":"10.1097\/MD.0000000000026374","article-title":"Effectiveness and safety of Chinese herbal formula combined with western medicine for ankylosing spondylitis: a protocol for systematic review and meta-analysis","volume":"100","author":"Liu","year":"2021","journal-title":"Med. Baltim."},{"key":"B7","doi-asserted-by":"publisher","first-page":"638","DOI":"10.1186\/s12891-020-03666-8","article-title":"Modified mini-open SRS-Schwab grade 4 osteotomy combined with percutaneous pedicle screws fixation in post-traumatic thoracolumbar kyphosis","volume":"21","author":"Liu","year":"2020","journal-title":"BMC Musculoskelet. Disord."},{"key":"B8","doi-asserted-by":"publisher","first-page":"399","DOI":"10.1007\/s11831-014-9120-1","article-title":"On the road to personalized medicine: multiscale computational modeling of bone tissue","volume":"21","author":"Podshivalov","year":"2014","journal-title":"Archives Comput. Methods Eng. State-of-the-Art Rev."},{"key":"B9","doi-asserted-by":"publisher","first-page":"1415","DOI":"10.1097\/BRS.0b013e318250dc95","article-title":"The influence of closing-opening wedge osteotomy on sagittal balance in thoracolumbar kyphosis secondary to ankylosing spondylitis: a comparison with closing wedge osteotomy","volume":"37","author":"Qian","year":"2012","journal-title":"Spine (Phila Pa 1976)"},{"key":"B10","doi-asserted-by":"publisher","first-page":"1321","DOI":"10.1007\/s10067-020-05354-3","article-title":"Characteristics and outcome of a first acute myocardial infarction in patients with ankylosing spondylitis","volume":"40","author":"S\u00f6dergren","year":"2021","journal-title":"Clin. Rheumatol."},{"key":"B11","doi-asserted-by":"publisher","first-page":"1392","DOI":"10.1177\/2192568220980716","article-title":"Does the level of pedicle subtraction osteotomy affect the surgical outcomes in ankylosing spondylitis-related thoracolumbar kyphosis with the same curve pattern?","volume":"12","author":"Tang","year":"2022","journal-title":"Glob. Spine J."},{"key":"B12","doi-asserted-by":"publisher","first-page":"267","DOI":"10.1007\/s10237-014-0601-9","article-title":"Synchrotron X-ray phase nano-tomography-based analysis of the lacunar-canalicular network morphology and its relation to the strains experienced by osteocytes in situ as predicted by case-specific finite element analysis","volume":"14","author":"Varga","year":"2015","journal-title":"Biomech. Model Mechanobiol."},{"key":"B13","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1155\/2018\/4071356","article-title":"Computational investigation on the biomechanical responses of the osteocytes to the compressive stimulus: a poroelastic model","volume":"2018","author":"Wang","year":"2018","journal-title":"Biomed. Res. Int."},{"key":"B14","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1155\/2015\/376474","article-title":"Strain amplification analysis of an osteocyte under static and cyclic loading: a finite element study","volume":"2015","author":"Wang","year":"2015","journal-title":"Biomed. Res. Int."},{"key":"B15","doi-asserted-by":"publisher","first-page":"1533","DOI":"10.7507\/1002-1892.202006129","article-title":"Treatment of chronic thoracolumbar osteoporotic fractures combined with kyphosis with cement-injectable cannulated pedicle screw and multiple level Schwab grade \u2160 osteotomy","volume":"34","author":"Zhang","year":"2020","journal-title":"Zhongguo Xiu Fu Chong Jian Wai Ke Za Zhi"}],"container-title":["Frontiers in Bioengineering and Biotechnology"],"original-title":[],"link":[{"URL":"https:\/\/www.frontiersin.org\/articles\/10.3389\/fbioe.2023.1220102\/full","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,9,13]],"date-time":"2023-09-13T06:37:49Z","timestamp":1694587069000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.frontiersin.org\/articles\/10.3389\/fbioe.2023.1220102\/full"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2023,9,12]]},"references-count":15,"alternative-id":["10.3389\/fbioe.2023.1220102"],"URL":"https:\/\/doi.org\/10.3389\/fbioe.2023.1220102","relation":{},"ISSN":["2296-4185"],"issn-type":[{"value":"2296-4185","type":"electronic"}],"subject":[],"published":{"date-parts":[[2023,9,12]]},"article-number":"1220102"}}