{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,4,5]],"date-time":"2026-04-05T09:52:03Z","timestamp":1775382723335,"version":"3.50.1"},"reference-count":44,"publisher":"Frontiers Media SA","license":[{"start":{"date-parts":[[2024,1,5]],"date-time":"2024-01-05T00:00:00Z","timestamp":1704412800000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"funder":[{"DOI":"10.13039\/501100008530","name":"European Regional Development Fund","doi-asserted-by":"publisher","id":[{"id":"10.13039\/501100008530","id-type":"DOI","asserted-by":"publisher"}]}],"content-domain":{"domain":["frontiersin.org"],"crossmark-restriction":true},"short-container-title":["Front. Bioeng. Biotechnol."],"abstract":"<jats:p><jats:bold>Introduction:<\/jats:bold> To preserve knee function, surgical repair is indicated when a meniscal root disinsertion occurs. However, this surgery has not yet achieved complete recovery of the joint\u00b4s natural biomechanics, with the meniscus-suture interface identified as a potentially determining factor. Knowing the deformation and resistance behavior of the sutured meniscal horn and whether these properties are preserved as the patient ages could greatly contribute to improving repair outcomes.<\/jats:p><jats:p><jats:bold>Methods:<\/jats:bold> A cadaveric experimental study was conducted on human sutured menisci classified into three <jats:italic>n<\/jats:italic> = 22 age groups (young \u226455; 55 &amp;lt; middle-aged \u226475; 75 &amp;lt; old) were subjected to load-to-failure test by suture pulling. Meniscal thickness at the suture hole was measured and the applied traction force and tissue deformation in the suture area in the direction of traction were recorded during the test. The traction load that initiated the meniscal cut-out, <jats:inline-formula><mml:math xmlns:mml=\"http:\/\/www.w3.org\/1998\/Math\/MathML\" id=\"m1\"><mml:mrow><mml:msub><mml:mi>F<\/mml:mi><mml:mi>c<\/mml:mi><\/mml:msub><\/mml:mrow><\/mml:math><\/jats:inline-formula>, maximum load borne by the meniscus, <jats:inline-formula><mml:math xmlns:mml=\"http:\/\/www.w3.org\/1998\/Math\/MathML\" id=\"m2\"><mml:mrow><mml:msub><mml:mi>F<\/mml:mi><mml:mi>u<\/mml:mi><\/mml:msub><\/mml:mrow><\/mml:math><\/jats:inline-formula>, tissue stress at the cut-out initiation, <jats:inline-formula><mml:math xmlns:mml=\"http:\/\/www.w3.org\/1998\/Math\/MathML\" id=\"m3\"><mml:mrow><mml:msub><mml:mi>S<\/mml:mi><mml:mi>c<\/mml:mi><\/mml:msub><\/mml:mrow><\/mml:math><\/jats:inline-formula>, and equivalent stiffness modulus at the suture area, <jats:inline-formula><mml:math xmlns:mml=\"http:\/\/www.w3.org\/1998\/Math\/MathML\" id=\"m4\"><mml:mrow><mml:msub><mml:mi>m<\/mml:mi><mml:mi>s<\/mml:mi><\/mml:msub><\/mml:mrow><\/mml:math><\/jats:inline-formula>, were calculated.<\/jats:p><jats:p><jats:bold>Results:<\/jats:bold> At the tissue level, the resistance in terms of <jats:inline-formula><mml:math xmlns:mml=\"http:\/\/www.w3.org\/1998\/Math\/MathML\" id=\"m5\"><mml:mrow><mml:msub><mml:mi>S<\/mml:mi><mml:mi>c<\/mml:mi><\/mml:msub><\/mml:mrow><\/mml:math><\/jats:inline-formula> decrease with age (young: 47.2\u00a0MPa; middle-aged: 44.7\u00a0MPa; old: 33.8\u00a0MPa) being significantly different between the young and the old group (<jats:italic>p<\/jats:italic> = 0.015). Mean meniscal thickness increased with age (young: 2.50\u00a0mm; middle-aged: 2.92\u00a0mm; old: 3.38\u00a0mm; <jats:italic>p<\/jats:italic> = 0.001). Probably due to thickening, no differences in resistance were found at the specimen level, i.e., in <jats:inline-formula><mml:math xmlns:mml=\"http:\/\/www.w3.org\/1998\/Math\/MathML\" id=\"m6\"><mml:mrow><mml:msub><mml:mi>F<\/mml:mi><mml:mi>c<\/mml:mi><\/mml:msub><\/mml:mrow><\/mml:math><\/jats:inline-formula> (overall mean 58.2\u00a0N) and <jats:inline-formula><mml:math xmlns:mml=\"http:\/\/www.w3.org\/1998\/Math\/MathML\" id=\"m7\"><mml:mrow><mml:msub><mml:mi>F<\/mml:mi><mml:mi>u<\/mml:mi><\/mml:msub><\/mml:mrow><\/mml:math><\/jats:inline-formula> (overall mean 73.6\u00a0N). As for elasticity, <jats:inline-formula><mml:math xmlns:mml=\"http:\/\/www.w3.org\/1998\/Math\/MathML\" id=\"m8\"><mml:mrow><mml:msub><mml:mi>m<\/mml:mi><mml:mi>s<\/mml:mi><\/mml:msub><\/mml:mrow><\/mml:math><\/jats:inline-formula> was lower in the old group than in the young group (57.5\u00a0MPa vs. 113.6\u00a0MPa, <jats:italic>p<\/jats:italic> = 0.02) and the middle-aged one (57.5\u00a0MPa vs. 108.0\u00a0MPa, <jats:italic>p<\/jats:italic> = 0.04).<\/jats:p><jats:p><jats:bold>Conclusion:<\/jats:bold> Regarding the influence of age on the sutured meniscal horn tissue, <jats:italic>in vitro<\/jats:italic> experimentation revealed that meniscal horn specimens older than 75\u00a0years old had a more elastic tissue which was less resistant to cut-out than younger menisci at the suture hole area. However, a thickening of the meniscal horns with age, which was also found, leveled out the difference in the force that initiated the tear, as well as in the maximum force borne by the meniscus in the load-to-failure test.<\/jats:p>","DOI":"10.3389\/fbioe.2023.1249982","type":"journal-article","created":{"date-parts":[[2024,1,5]],"date-time":"2024-01-05T04:57:24Z","timestamp":1704430644000},"update-policy":"https:\/\/doi.org\/10.3389\/crossmark-policy","source":"Crossref","is-referenced-by-count":3,"title":["Age influence on resistance and deformation of the human sutured meniscal horn in the immediate postoperative period"],"prefix":"10.3389","volume":"11","author":[{"given":"Alejandro","family":"Pe\u00f1a-Trabalon","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Ana","family":"Perez-Blanca","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Salvador","family":"Moreno-Vegas","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"M. Belen","family":"Estebanez Campos","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Maria","family":"Prado-Novoa","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"1965","published-online":{"date-parts":[[2024,1,5]]},"reference":[{"key":"B1","doi-asserted-by":"publisher","first-page":"1510","DOI":"10.1007\/s00167-007-0310-3","article-title":"A pull out suture for transection of the posterior horn of the medial meniscus: using a posterior trans-septal portal","volume":"15","author":"Ahn","year":"2007","journal-title":"Knee Surg. Sports Traumatol. Arthrosc."},{"key":"B2","doi-asserted-by":"publisher","first-page":"2699","DOI":"10.1177\/0363546514549445","article-title":"Biomechanical comparison of arthroscopic repair constructs for meniscal root tears","volume":"42","author":"Anz","year":"2014","journal-title":"Am. J. Sports Med."},{"key":"B3","doi-asserted-by":"publisher","first-page":"e511","DOI":"10.1016\/J.EATS.2018.01.003","article-title":"Suture anchor refixation of meniscal root tears without an additional portal","volume":"7","author":"Balke","year":"2018","journal-title":"Arthrosc. Tech."},{"key":"B4","doi-asserted-by":"publisher","first-page":"2988","DOI":"10.1177\/0363546514549447","article-title":"Biomechanical evaluation of a transtibial pull-out meniscal root repair challenging the bungee effect","volume":"42","author":"Cerminara","year":"2014","journal-title":"Am. J. Sports Med."},{"key":"B5","doi-asserted-by":"publisher","first-page":"951","DOI":"10.1002\/JOR.20573","article-title":"Compressive moduli of the human medial meniscus in the axial and radial directions at equilibrium and at a physiological strain rate","volume":"26","author":"Chia","year":"2008","journal-title":"J. Orthop. Res."},{"key":"B6","doi-asserted-by":"publisher","first-page":"e1919","DOI":"10.1016\/J.EATS.2017.07.011","article-title":"Posterior lateral meniscus root reattachment with suture anchors: an arthroscopic technique","volume":"6","author":"Cu\u00e9llar","year":"2017","journal-title":"Arthrosc. Tech."},{"key":"B7","doi-asserted-by":"publisher","first-page":"105073","DOI":"10.1016\/J.JMBBM.2022.105073","article-title":"Mechanical properties of meniscal circumferential fibers using an inverse finite element analysis approach","volume":"126","author":"De Rosa","year":"2022","journal-title":"J. Mech. Behav. Biomed. Mater"},{"key":"B8","doi-asserted-by":"publisher","first-page":"2419","DOI":"10.1007\/s00264-023-05769-y","article-title":"Improved tibiofemoral contact restoration after transtibial reinsertion of the anterior root of the lateral meniscus compared to in situ repair: a biomechanical study","volume":"1","author":"Espejo-Reina","year":"2023","journal-title":"Int. Orthop."},{"key":"B9","doi-asserted-by":"publisher","first-page":"6182","DOI":"10.1038\/S41598-022-10229-5","article-title":"Biomechanical consequences of anterior root detachment of the lateral meniscus and its reinsertion","volume":"12","author":"Espejo-Reina","year":"2022","journal-title":"Sci. Rep."},{"key":"B10","doi-asserted-by":"publisher","first-page":"175","DOI":"10.3758\/BF03193146","article-title":"G*Power 3: a flexible statistical power analysis program for the social, behavioral, and biomedical sciences","volume":"39","author":"Faul","year":"2007","journal-title":"Behav. Res. Methods"},{"key":"B11","doi-asserted-by":"publisher","first-page":"2784","DOI":"10.1177\/0363546513502464","article-title":"Biomechanical evaluation of different suture techniques for arthroscopic transtibial pull-out repair of posterior medial meniscus root tears","volume":"41","author":"Feucht","year":"2013","journal-title":"Am. J. Sports Med."},{"key":"B12","doi-asserted-by":"publisher","first-page":"2342","DOI":"10.1177\/0363546512457642","article-title":"Qualitative and quantitative anatomic analysis of the posterior root attachments of the medial and lateral menisci","volume":"40","author":"Johannsen","year":"2012","journal-title":"Am. J. Sports Med."},{"key":"B13","doi-asserted-by":"publisher","first-page":"306","DOI":"10.1111\/J.1440-1673.2006.01586.X","article-title":"Medial meniscus posterior root attachment injury and degeneration: MRI findings","volume":"50","author":"Jones","year":"2006","journal-title":"Australas. Radiol."},{"key":"B14","doi-asserted-by":"publisher","first-page":"1644","DOI":"10.1016\/J.ARTHRO.2011.06.033","article-title":"Arthroscopic suture anchor repair versus pullout suture repair in posterior root tear of the medial meniscus: a prospective comparison study","volume":"27","author":"Kim","year":"2011","journal-title":"Arthrosc. J. Arthrosc. Relat. Surg."},{"key":"B15","doi-asserted-by":"publisher","first-page":"795.e1","DOI":"10.1016\/J.ARTHRO.2005.12.040","article-title":"Arthroscopic pullout repair of a complete radial tear of the tibial attachment site of the medial meniscus posterior horn","volume":"22","author":"Kim","year":"2006","journal-title":"Arthroscopy"},{"key":"B16","doi-asserted-by":"publisher","first-page":"2141","DOI":"10.1177\/0363546511413250","article-title":"Meniscal root suturing techniques: implications for root fixation","volume":"39","author":"Kopf","year":"2011","journal-title":"Am. J. Sports Med."},{"key":"B17","doi-asserted-by":"publisher","first-page":"951","DOI":"10.1016\/J.ARTHRO.2009.03.018","article-title":"Arthroscopic pullout suture repair of posterior root tear of the medial meniscus: radiographic and clinical results with a 2-year follow-up","volume":"25","author":"Lee","year":"2009","journal-title":"Arthrosc. J. Arthrosc. Relat. Surg."},{"key":"B18","doi-asserted-by":"publisher","first-page":"38","DOI":"10.1186\/S40634-019-0206-4","article-title":"The rebar repair for radial meniscus tears: a biomechanical comparison of a reinforced suture repair versus parallel and cross-stitch techniques","volume":"6","author":"Massey","year":"2019","journal-title":"J. Exp. Orthop."},{"key":"B19","doi-asserted-by":"publisher","first-page":"e953","DOI":"10.1016\/j.eats.2020.03.013","article-title":"Rebar repair of radial meniscus tears: a reinforced suture technique","volume":"9","author":"Massey","year":"2020","journal-title":"Arthrosc. Tech."},{"key":"B20","doi-asserted-by":"publisher","first-page":"111","DOI":"10.1016\/J.ARTHRO.2015.07.013","article-title":"Medial meniscal root avulsion: a biomechanical comparison of 4 different repair constructs","volume":"32","author":"Mitchell","year":"2016","journal-title":"Arthrosc. J. Arthrosc. Relat. Surg."},{"key":"B21","doi-asserted-by":"publisher","first-page":"1138","DOI":"10.1177\/0363546511435622","article-title":"Prognostic factors of arthroscopic pull-out repair for a posterior root tear of the medial meniscus","volume":"40","author":"Moon","year":"2010","journal-title":"Am. J. Sports Med."},{"key":"B22","doi-asserted-by":"publisher","first-page":"605","DOI":"10.1016\/J.JOCA.2022.01.001","article-title":"Mechanisms of energy dissipation and relationship with tissue composition in human meniscus","volume":"30","author":"Morejon","year":"2022","journal-title":"Osteoarthr. Cartil."},{"key":"B23","doi-asserted-by":"publisher","first-page":"110343","DOI":"10.1016\/J.JBIOMECH.2021.110343","article-title":"Viscoelastic and equilibrium shear properties of human meniscus: relationships with tissue structure and composition","volume":"120","author":"Norberg","year":"2021","journal-title":"J. Biomech."},{"key":"B24","doi-asserted-by":"publisher","first-page":"1863","DOI":"10.1177\/0363546512453291","article-title":"Effects of serial sectioning and repair of radial tears in the lateral meniscus","volume":"40","author":"Ode","year":"2012","journal-title":"Am. J. Sports Med."},{"key":"B25","doi-asserted-by":"publisher","first-page":"699","DOI":"10.1177\/0363546513499314","article-title":"Biomechanical consequences of a complete radial tear adjacent to the medial meniscus posterior root attachment site: in situ pull-out repair restores derangement of joint mechanics","volume":"42","author":"Padalecki","year":"2014","journal-title":"Am. J. Sports Med."},{"key":"B26","doi-asserted-by":"publisher","first-page":"1132","DOI":"10.1016\/j.joca.2011.05.008","article-title":"Macroscopic and histopathologic analysis of human knee menisci in aging and osteoarthritis","volume":"19","author":"Pauli","year":"2011","journal-title":"Osteoarthr. Cartil."},{"key":"B27","doi-asserted-by":"publisher","first-page":"624","DOI":"10.1016\/j.arthro.2015.08.040","article-title":"Comparative biomechanical study on contact alterations after lateral meniscus posterior root avulsion, transosseous reinsertion, and total meniscectomy","volume":"32","author":"Perez-Blanca","year":"2016","journal-title":"Arthrosc. J. Arthrosc. Relat. Surg."},{"key":"B28","doi-asserted-by":"publisher","first-page":"811","DOI":"10.1007\/s00264-018-3799-9","article-title":"The role of suture cutout in the failure of meniscal root repair during the early post-operative period: a biomechanical study","volume":"42","author":"Perez-Blanca","year":"2018","journal-title":"Int. Orthop."},{"key":"B29","volume-title":"Biomec\u00e1nica de la reinserci\u00f3n transtibial de la ra\u00edz posterior del menisco lateral de la rodilla: avances en la t\u00e9cnica de reparaci\u00f3n","author":"P\u00e9rez de la Blanca","year":"2019"},{"key":"B30","doi-asserted-by":"publisher","first-page":"237","DOI":"10.1007\/s00402-013-1873-8","article-title":"Posterior root tear of the medial and lateral meniscus","volume":"134","author":"Petersen","year":"2014","journal-title":"Arch. Orthop. Trauma Surg."},{"key":"B31","doi-asserted-by":"publisher","first-page":"984","DOI":"10.1007\/s00113-006-1193-3","article-title":"Avulsion injury to the posterior horn of the lateral meniscus. Technique for arthroscopic refixation","volume":"109","author":"Petersen","year":"2006","journal-title":"Unfallchirurg"},{"key":"B32","doi-asserted-by":"publisher","first-page":"1748","DOI":"10.1038\/S41598-020-58656-6","article-title":"Initial biomechanical properties of transtibial meniscal root repair are improved by using a knotless anchor as a post-insertion tensioning device","volume":"10","author":"Prado-Novoa","year":"2020","journal-title":"Sci. Rep."},{"key":"B33","doi-asserted-by":"publisher","first-page":"2573","DOI":"10.3390\/MA15072573","article-title":"Influence of loading conditions on the mechanical performance of multifilament coreless UHMWPE sutures used in orthopaedic surgery","volume":"15","author":"Prado-Novoa","year":"2022","journal-title":"Materials"},{"key":"B34","doi-asserted-by":"publisher","first-page":"281","DOI":"10.1007\/978-981-13-3681-2_11","article-title":"Connective tissue and age-related diseases","volume":"91","author":"Sarbacher","year":"2019","journal-title":"Subcell. Biochem."},{"key":"B35","doi-asserted-by":"publisher","first-page":"659989","DOI":"10.3389\/fbioe.2021.659989","article-title":"Osteoarthritis-related degeneration alters the biomechanical properties of human menisci before the articular cartilage","volume":"9","author":"Seitz","year":"2021","journal-title":"Front. Bioeng. Biotechnol."},{"key":"B36","doi-asserted-by":"publisher","first-page":"74","DOI":"10.1177\/03635465020300012601","article-title":"Nonanatomic location of the posterior horn of a medial meniscal autograft implanted in a cadaveric knee adversely affects the pressure distribution on the tibial plateau","volume":"30","author":"Sekaran","year":"2002","journal-title":"Am. J. Sports Med."},{"key":"B37","doi-asserted-by":"publisher","first-page":"99","DOI":"10.1177\/0363546510382225","article-title":"Second-look arthroscopic findings after repairs of posterior root tears of the medial meniscus","volume":"39","author":"Seo","year":"2010","journal-title":"Am. J. Sports Med."},{"key":"B38","doi-asserted-by":"publisher","first-page":"081004","DOI":"10.1115\/1.4045893","article-title":"Nonanatomic placement of posteromedial meniscal root repairs: a finite element study","volume":"142","author":"Steineman","year":"2020","journal-title":"J. Biomech. Eng."},{"key":"B39","doi-asserted-by":"publisher","first-page":"1262","DOI":"10.1016\/J.KNEE.2017.08.001","article-title":"Age-related changes in the knee meniscus","volume":"24","author":"Tsujii","year":"2017","journal-title":"Knee"},{"key":"B40","doi-asserted-by":"publisher","first-page":"232596712110004","DOI":"10.1177\/23259671211000464","article-title":"Biomechanical comparison of an all-inside meniscal repair device construct versus pullout sutures for arthroscopic transtibial repair of posterior medial meniscus root tears A matched-pair cadaveric study","volume":"9","author":"Vertullo","year":"2021","journal-title":"Orthop. J. Sports Med."},{"key":"B41","doi-asserted-by":"publisher","first-page":"123","DOI":"10.1007\/s10439-007-9403-x","article-title":"A quantitative study of the microstructure and biochemistry of the medial meniscal horn attachments","volume":"36","author":"Villegas","year":"2008","journal-title":"Ann. Biomed. Eng."},{"key":"B42","doi-asserted-by":"publisher","first-page":"536","DOI":"10.3760\/CMA.J.ISSN.0366-6999.2009.05.010","article-title":"An anatomical and histological study of human meniscal horn bony insertions and peri-meniscal attachments as a basis for meniscal transplantation","volume":"122","author":"Wang","year":"2009","journal-title":"Chin. Med. J. Engl."},{"key":"B43","doi-asserted-by":"publisher","first-page":"44","DOI":"10.1680\/jemmr.15.00031","article-title":"Tensile biomechanical characteristics of human meniscus","volume":"5","author":"Yan","year":"2016","journal-title":"Emerg. Mater. Res."},{"key":"B44","doi-asserted-by":"publisher","first-page":"863","DOI":"10.1177\/0363546503260749","article-title":"Initial fixation strength of flexible all-inside meniscus suture anchors in comparison to conventional suture technique and rigid anchors biomechanical evaluation of new meniscus refixation systems","volume":"32","author":"Zantop","year":"2004","journal-title":"Am. J. Sports Med."}],"container-title":["Frontiers in Bioengineering and Biotechnology"],"original-title":[],"link":[{"URL":"https:\/\/www.frontiersin.org\/articles\/10.3389\/fbioe.2023.1249982\/full","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2024,1,5]],"date-time":"2024-01-05T04:57:40Z","timestamp":1704430660000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.frontiersin.org\/articles\/10.3389\/fbioe.2023.1249982\/full"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2024,1,5]]},"references-count":44,"alternative-id":["10.3389\/fbioe.2023.1249982"],"URL":"https:\/\/doi.org\/10.3389\/fbioe.2023.1249982","relation":{},"ISSN":["2296-4185"],"issn-type":[{"value":"2296-4185","type":"electronic"}],"subject":[],"published":{"date-parts":[[2024,1,5]]},"article-number":"1249982"}}