{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,7,20]],"date-time":"2026-07-20T19:45:54Z","timestamp":1784576754370,"version":"3.55.0"},"reference-count":35,"publisher":"Frontiers Media SA","license":[{"start":{"date-parts":[[2023,12,1]],"date-time":"2023-12-01T00:00:00Z","timestamp":1701388800000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"content-domain":{"domain":["frontiersin.org"],"crossmark-restriction":true},"short-container-title":["Front. Bioeng. Biotechnol."],"abstract":"<jats:p><jats:bold>Background:<\/jats:bold> Plate osteosynthesis is a widely used technique for bone fracture fixation; however, complications such as plate bending remain a significant clinical concern. A better understanding of the failure mechanisms behind plate osteosynthesis is crucial for improving treatment outcomes. This study aimed to develop finite element (FE) models to predict plate bending failure and validate these against <jats:italic>in vitro<\/jats:italic> experiments using literature-based and experimentally determined implant material properties.<\/jats:p><jats:p><jats:bold>Methods:<\/jats:bold> Plate fixations of seven cadaveric tibia shaft fractures were tested to failure in a biomechanical setup with various implant configurations. FE models of the bone-implant constructs were developed from computed tomography (CT) scans. Elasto-plastic implant material properties were assigned using either literature data or the experimentally derived data. The predictive capability of these two FE modelling approaches was assessed based on the experimental ground truth.<\/jats:p><jats:p><jats:bold>Results:<\/jats:bold> The FE simulations provided quantitatively correct prediction of the <jats:italic>in vitro<\/jats:italic> cadaveric experiments in terms of construct stiffness [concordance correlation coefficient (CCC) = 0.97, standard error of estimate (SEE) = 23.66, relative standard error (RSE) = 10.3%], yield load (CCC = 0.97, SEE = 41.21N, RSE = 7.7%), and maximum force (CCC = 0.96, SEE = 35.04, RSE = 9.3%), when including the experimentally determined material properties. Literature-based properties led to inferior accuracies for both stiffness (CCC = 0.92, SEE = 27.62, RSE = 19.6%), yield load (CCC = 0.83, SEE = 46.53N, RSE = 21.4%), and maximum force (CCC = 0.86, SEE = 57.71, RSE = 14.4%).<\/jats:p><jats:p><jats:bold>Conclusion:<\/jats:bold> The validated FE model allows for accurate prediction of plate osteosynthesis construct behaviour beyond the elastic regime but only when using experimentally determined implant material properties. Literature-based material properties led to inferior predictability. These validated models have the potential to be utilized for assessing the loads leading to plastic deformation <jats:italic>in vivo<\/jats:italic>, as well as aiding in preoperative planning and postoperative rehabilitation protocols.<\/jats:p>","DOI":"10.3389\/fbioe.2023.1268787","type":"journal-article","created":{"date-parts":[[2023,12,1]],"date-time":"2023-12-01T16:41:00Z","timestamp":1701448860000},"update-policy":"https:\/\/doi.org\/10.3389\/crossmark-policy","source":"Crossref","is-referenced-by-count":8,"title":["On the importance of accurate elasto-plastic material properties in simulating plate osteosynthesis failure"],"prefix":"10.3389","volume":"11","author":[{"given":"Dominic","family":"Mischler","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Boyko","family":"Gueorguiev","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Markus","family":"Windolf","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Peter","family":"Varga","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"1965","published-online":{"date-parts":[[2023,12,1]]},"reference":[{"key":"B1","doi-asserted-by":"publisher","first-page":"1128","DOI":"10.3390\/ma12071128","article-title":"Failure analysis of a humeral shaft locking compression plate-surface investigation and simulation by finite element method","volume":"12","author":"Antoniac","year":"2019","journal-title":"Mater. (Basel)"},{"key":"B2","volume-title":"ASTM d638-14 (2014) standard test method for tensile properties of plastics","author":"ASTM International","year":"2014"},{"key":"B3","doi-asserted-by":"publisher","first-page":"S2","DOI":"10.1016\/s0020-1383(18)30294-8","article-title":"Evolution of fracture treatment with bone plates","volume":"49","author":"Augat","year":"2018","journal-title":"Injury"},{"key":"B4","doi-asserted-by":"publisher","first-page":"389","DOI":"10.1097\/00005131-199608000-00005","article-title":"Titanium plate fixation: a review of implant failures","volume":"10","author":"Banovetz","year":"1996","journal-title":"J. Orthop. Trauma"},{"key":"B5","doi-asserted-by":"publisher","first-page":"1064","DOI":"10.1080\/10255842.2020.1867114","article-title":"A comparative finite element simulation of locking compression plate materials for tibial fracture treatment","volume":"24","author":"Beirami","year":"2021","journal-title":"Comput. Methods Biomech. Biomed. Engin"},{"key":"B6","doi-asserted-by":"publisher","first-page":"565","DOI":"10.1097\/00005131-200409000-00015","article-title":"Failure of less invasive stabilization system plates in the distal femur: a report of four cases","volume":"18","author":"Button","year":"2004","journal-title":"J. Orthop. Trauma"},{"key":"B7","doi-asserted-by":"publisher","first-page":"119","DOI":"10.1243\/09544119jeim670","article-title":"Computational investigations of mechanical failures of internal plate fixation","volume":"224","author":"Chen","year":"2010","journal-title":"Proc. Inst. Mech. Eng. H."},{"key":"B8","article-title":"Implant materials. Wrought 18% chromium\u2013 14% nickel\u20132.5%Molybdenum stainless steel","volume-title":"Synthes","author":"Disegi","year":""},{"key":"B9","article-title":"Implant materials. Unalloyed titanium","volume-title":"Synthes","author":"Disegi","year":""},{"key":"B10","doi-asserted-by":"publisher","first-page":"742","DOI":"10.1007\/s10439-010-0196-y","article-title":"Robust QCT\/FEA models of proximal femur stiffness and fracture load during a sideways fall on the hip","volume":"39","author":"Dragomir-Daescu","year":"2011","journal-title":"Ann. Biomed. Eng."},{"key":"B11","doi-asserted-by":"publisher","first-page":"2845","DOI":"10.3390\/ijerph15122845","article-title":"Incidence, costs and predictors of non-union, delayed union and mal-union following long bone fracture","volume":"15","author":"Ekegren","year":"2018","journal-title":"Int. J. Environ. Res. Public Health"},{"key":"B12","volume-title":"Trauma fixation \u2013 global analysis and market forecasts","author":"GlobalData_MediPoint","year":"2016"},{"key":"B13","doi-asserted-by":"publisher","first-page":"S56","DOI":"10.1016\/s0020-1383(18)30305-x","article-title":"Why and how do locking plates fail?","volume":"49","author":"Gueorguiev","year":"2018","journal-title":"Injury"},{"key":"B14","doi-asserted-by":"publisher","first-page":"S3","DOI":"10.1016\/j.injury.2014.04.002","article-title":"Delayed union and nonunions: epidemiology, clinical issues, and financial aspects","volume":"45","author":"Hak","year":"2014","journal-title":"Injury"},{"key":"B15","doi-asserted-by":"publisher","first-page":"2209","DOI":"10.3390\/ma14092209","article-title":"Microstructural analysis of fractured orthopedic implants","volume":"14","author":"Kopec","year":"2021","journal-title":"Mater. (Basel)"},{"key":"B16","doi-asserted-by":"publisher","first-page":"S73","DOI":"10.1007\/s00198-004-1764-5","article-title":"Distal humerus fractures in elderly patients: results after open reduction and internal fixation","volume":"16","author":"Korner","year":"2005","journal-title":"Osteoporos. Int."},{"key":"B17","doi-asserted-by":"publisher","first-page":"2675","DOI":"10.1007\/s00264-018-3864-4","article-title":"Healing, nonunion, and re-operation after internal fixation of diaphyseal and distal femoral fractures: a systematic review and meta-analysis","volume":"42","author":"Koso","year":"2018","journal-title":"Int. Orthop."},{"key":"B18","doi-asserted-by":"publisher","first-page":"509","DOI":"10.1097\/00005131-200409000-00006","article-title":"Treatment of distal femur fractures using the less invasive stabilization system: surgical experience and early clinical results in 103 fractures","volume":"18","author":"Kregor","year":"2004","journal-title":"J. Orthop. Trauma"},{"key":"B19","doi-asserted-by":"publisher","first-page":"403","DOI":"10.1007\/s11914-021-00690-y","article-title":"Finite element analysis of fracture fixation","volume":"19","author":"Lewis","year":"2021","journal-title":"Curr. Osteoporos. Rep."},{"key":"B20","doi-asserted-by":"publisher","first-page":"1712","DOI":"10.1016\/j.jbiomech.2012.04.008","article-title":"Does screw-bone interface modelling matter in finite element analyses?","volume":"45","author":"MacLeod","year":"2012","journal-title":"J. Biomech."},{"key":"B21","doi-asserted-by":"publisher","first-page":"105097","DOI":"10.1016\/j.clinbiomech.2020.105097","article-title":"Comparison of optimal screw configurations in two locking plate systems for proximal humerus fixation - a finite element analysis study","volume":"78","author":"Mischler","year":"2020","journal-title":"Clin. Biomech. (Bristol, Avon)"},{"key":"B22","doi-asserted-by":"publisher","first-page":"408","DOI":"10.1177\/0954411920985757","article-title":"A mechanobiological approach to find the optimal thickness for the locking compression plate: finite element investigations","volume":"235","author":"Mohandes","year":"2021","journal-title":"Proc. Inst. Mech. Eng. H."},{"key":"B23","doi-asserted-by":"publisher","first-page":"465","DOI":"10.1186\/s12891-019-2847-y","article-title":"Finite element analysis comparison between superior clavicle locking plate with and without screw holes above fracture zone in midshaft clavicular fracture","volume":"20","author":"Pengrung","year":"2019","journal-title":"BMC Musculoskelet. Disord."},{"key":"B24","doi-asserted-by":"publisher","first-page":"1093","DOI":"10.1302\/0301-620x.84b8.0841093","article-title":"Evolution of the internal fixation of long bone fractures","author":"Perren","year":"2002","journal-title":"J. Bone Jt. Surg. Br."},{"key":"B25","doi-asserted-by":"publisher","first-page":"267","DOI":"10.55095\/achot2014\/035","article-title":"Biomechanical and biological aspects of defect treatment in fractures using helical plates","volume":"81","author":"Perren","year":"2014","journal-title":"Acta Chir. Orthop."},{"key":"B26","doi-asserted-by":"publisher","first-page":"77","DOI":"10.4103\/1110-1148.165879","article-title":"Primary bone grafting with locked plating for comminuted distal femoral fractures: can it improve the results?","volume":"50","author":"Rizk","year":"2015","journal-title":"Egypt. Orthop. J."},{"key":"B27","doi-asserted-by":"publisher","first-page":"247","DOI":"10.1007\/s00264-017-3734-5","article-title":"Diaphyseal long bone nonunions - types, aetiology, economics, and treatment recommendations","volume":"42","author":"Rupp","year":"2018","journal-title":"Int. Orthop."},{"key":"B28","doi-asserted-by":"publisher","first-page":"571","DOI":"10.1097\/00005131-200409000-00016","article-title":"Locking compression plate loosening and plate breakage: a report of four cases","volume":"18","author":"Sommer","year":"2004","journal-title":"J. Orthop. Trauma"},{"key":"B29","doi-asserted-by":"publisher","first-page":"276","DOI":"10.1186\/s12891-021-04152-5","article-title":"Finite element analysis of double-plate fixation using reversed locking compression-distal femoral plates for Vancouver B1 periprosthetic femoral fractures","volume":"22","author":"Takahashi","year":"2021","journal-title":"BMC Musculoskelet. Disord."},{"key":"B30","doi-asserted-by":"publisher","first-page":"767","DOI":"10.1016\/j.jbiomech.2014.12.019","article-title":"Four decades of finite element analysis of orthopaedic devices: where are we now and what are the opportunities?","volume":"48","author":"Taylor","year":"2015","journal-title":"J. Biomech."},{"key":"B31","doi-asserted-by":"publisher","first-page":"846","DOI":"10.2106\/jbjs.e.00543","article-title":"Failure of LCP condylar plate fixation in the distal part of the femur. A report of six cases","volume":"88","author":"Vallier","year":"2006","journal-title":"J. Bone Jt. Surg. Am."},{"key":"B32","doi-asserted-by":"publisher","first-page":"858","DOI":"10.3390\/medicina58070858","article-title":"Continuous implant load monitoring to assess bone healing status-evidence from animal testing","volume":"58","author":"Windolf","year":"2022","journal-title":"Med. Kaunas."},{"key":"B33","doi-asserted-by":"publisher","first-page":"1957","DOI":"10.1016\/j.jse.2021.02.017","article-title":"Complications of articular distal humeral fracture fixation: a systematic review and meta-analysis","volume":"30","author":"Yetter","year":"2021","journal-title":"J. Shoulder Elb. Surg."},{"key":"B34","doi-asserted-by":"publisher","first-page":"8590251","DOI":"10.1155\/2017\/8590251","article-title":"Biomechanical property of a newly designed assembly locking compression plate: three-dimensional finite element analysis","volume":"2017","author":"Zhou","year":"2017","journal-title":"J. Healthc. Eng."},{"key":"B35","doi-asserted-by":"publisher","first-page":"e162775","DOI":"10.1001\/jamasurg.2016.2775","article-title":"Epidemiology of fracture nonunion in 18 human bones","volume":"151","author":"Zura","year":"2016","journal-title":"JAMA Surg."}],"container-title":["Frontiers in Bioengineering and Biotechnology"],"original-title":[],"link":[{"URL":"https:\/\/www.frontiersin.org\/articles\/10.3389\/fbioe.2023.1268787\/full","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,12,1]],"date-time":"2023-12-01T16:41:04Z","timestamp":1701448864000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.frontiersin.org\/articles\/10.3389\/fbioe.2023.1268787\/full"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2023,12,1]]},"references-count":35,"alternative-id":["10.3389\/fbioe.2023.1268787"],"URL":"https:\/\/doi.org\/10.3389\/fbioe.2023.1268787","relation":{},"ISSN":["2296-4185"],"issn-type":[{"value":"2296-4185","type":"electronic"}],"subject":[],"published":{"date-parts":[[2023,12,1]]},"article-number":"1268787"}}