{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,6,24]],"date-time":"2026-06-24T20:14:23Z","timestamp":1782332063170,"version":"3.54.5"},"reference-count":30,"publisher":"Frontiers Media SA","license":[{"start":{"date-parts":[[2024,1,22]],"date-time":"2024-01-22T00:00:00Z","timestamp":1705881600000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"content-domain":{"domain":["frontiersin.org"],"crossmark-restriction":true},"short-container-title":["Front. Bioeng. Biotechnol."],"abstract":"<jats:p><jats:bold>Objective:<\/jats:bold> To investigate the biomechanical properties of the retropharyngeal reduction plate by comparing the traditional posterior pedicle screw-rod fixation by finite element analysis.<\/jats:p><jats:p><jats:bold>Methods:<\/jats:bold> Two three-dimensional finite element digital models of the retropharyngeal reduction plate and posterior pedicle screw-rod fixation were constructed and validated based on the DICOM (Digital Imaging and Communications in Medicine) data from C1 to C4. The biomechanical finite element analysis values of two internal fixations were measured and calculated under different conditions, including flexion, extension, bending, and rotation.<\/jats:p><jats:p><jats:bold>Results:<\/jats:bold> In addition to the backward extension, there was no significant difference in the maximum von Mises stress between the retropharyngeal reduction plate and posterior pedicle screw fixation under other movement conditions. The retropharyngeal reduction plate has a more uniform distribution under different conditions, such as flexion, extension, bending, and rotation. The stress tolerance of the two internal fixations was basically consistent in flexion, extension, left bending, and right bending.<\/jats:p><jats:p><jats:bold>Conclusion:<\/jats:bold> The retropharyngeal reduction plate has a relatively good biomechanical stability without obvious stress concentration under different movement conditions. It shows potential as a fixation option for the treatment of atlantoaxial dislocation.<\/jats:p>","DOI":"10.3389\/fbioe.2024.1346850","type":"journal-article","created":{"date-parts":[[2024,1,22]],"date-time":"2024-01-22T16:43:23Z","timestamp":1705941803000},"update-policy":"https:\/\/doi.org\/10.3389\/crossmark-policy","source":"Crossref","is-referenced-by-count":1,"title":["The retropharyngeal reduction plate for atlantoaxial dislocation: a finite element analysis"],"prefix":"10.3389","volume":"12","author":[{"given":"Weiqing","family":"Kong","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Yukun","family":"Du","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Jianyi","family":"Li","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Jiale","family":"Shao","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Yongming","family":"Xi","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"1965","published-online":{"date-parts":[[2024,1,22]]},"reference":[{"key":"B1","doi-asserted-by":"publisher","first-page":"147","DOI":"10.1007\/978-3-319-62515-7_21","article-title":"The high cervical anterolateral retropharyngeal approach","volume":"125","author":"Alshafai","year":"2019","journal-title":"Acta Neurochir. Suppl."},{"key":"B2","doi-asserted-by":"publisher","first-page":"568","DOI":"10.1016\/j.wneu.2017.09.135","article-title":"Craniovertebral junction transoral approach: predictive factors of complications","volume":"110","author":"Amelot","year":"2018","journal-title":"World Neurosurg."},{"key":"B3","doi-asserted-by":"publisher","first-page":"168","DOI":"10.1186\/s12938-016-0246-2","article-title":"Compression-distraction reduction surgical verification and optimization to treat the basilar invagination and atlantoaxial dislocation: a finite element analysis","volume":"15","author":"Bo","year":"2016","journal-title":"Biomed. Eng. online"},{"key":"B4","doi-asserted-by":"publisher","first-page":"107","DOI":"10.1016\/j.jot.2020.03.006","article-title":"Comparative analysis of the biomechanics of the adjacent segments after minimally invasive cervical surgeries versus anterior cervical discectomy and fusion: a finite element study","volume":"23","author":"Chen","year":"2020","journal-title":"J. Orthop. Transl."},{"key":"B5","doi-asserted-by":"publisher","first-page":"507","DOI":"10.1007\/s00586-020-06527-z","article-title":"Anterior release without odontoidectomy for irreducible atlantoaxial dislocation: transoral or endoscopic transnasal?","volume":"30","author":"Dong","year":"2021","journal-title":"Eur. spine J."},{"key":"B6","doi-asserted-by":"publisher","first-page":"284","DOI":"10.1007\/s00586-016-4916-3","article-title":"Traumatic atlantoaxial rotatory fixation in an adult patient","volume":"28","author":"Garc\u00eda-Pallero","year":"2019","journal-title":"Eur. spine J."},{"key":"B7","doi-asserted-by":"publisher","first-page":"59","DOI":"10.1007\/978-3-319-62515-7_9","article-title":"Atlantoaxial instability: evolving understanding","volume":"125","author":"Goel","year":"2019","journal-title":"Acta Neurochir. Suppl."},{"key":"B8","doi-asserted-by":"publisher","first-page":"657","DOI":"10.14444\/7096","article-title":"Is transoral surgery still a relevant procedure in atlantoaxial instability?","volume":"14","author":"Govindasamy","year":"2020","journal-title":"Int. J. spine Surg."},{"key":"B9","doi-asserted-by":"publisher","first-page":"239","DOI":"10.1186\/s12891-020-03273-7","article-title":"Surgical treatment of atlantoaxial subluxation by intraoperative skull traction and C1-C2 fixation","volume":"21","author":"Guo","year":"2020","journal-title":"BMC Musculoskelet. Disord."},{"key":"B10","doi-asserted-by":"publisher","first-page":"1371","DOI":"10.2169\/internalmedicine.1315-18","article-title":"Atlantoaxial rotatory fixation","volume":"58","author":"Kenzaka","year":"2019","journal-title":"Intern. Med. (Tokyo, Jpn."},{"key":"B11","doi-asserted-by":"publisher","first-page":"403","DOI":"10.1007\/s11914-021-00690-y","article-title":"Finite element analysis of fracture fixation","volume":"19","author":"Lewis","year":"2021","journal-title":"Curr. Osteoporos. Rep."},{"key":"B12","doi-asserted-by":"publisher","first-page":"456","DOI":"10.1186\/s13018-023-03905-3","article-title":"Biomechanical properties of different anterior and posterior techniques for atlantoaxial fixation: a finite element analysis","volume":"18","author":"Li","year":"2023","journal-title":"J. Orthop. Surg. Res."},{"key":"B13","doi-asserted-by":"publisher","first-page":"522","DOI":"10.1111\/os.13217","article-title":"Retropharyngeal Reduction Plate for atlantoaxial dislocation: a cadaveric test and morphometric trajectory analysis","volume":"14","author":"Li","year":"2022","journal-title":"Orthop. Surg."},{"key":"B14","doi-asserted-by":"publisher","first-page":"47","DOI":"10.1016\/j.jot.2019.06.007","article-title":"Three-dimensional finite-element analysis of aggravating medial meniscus tears on knee osteoarthritis","volume":"20","author":"Li","year":"2020","journal-title":"J. Orthop. Transl."},{"key":"B15","doi-asserted-by":"publisher","first-page":"674","DOI":"10.1016\/j.spinee.2017.12.011","article-title":"Biomechanical evaluation of C1 lateral mass and C2 translaminar bicortical screws in atlantoaxial fixation: an in vitro human cadaveric study","volume":"18","author":"Liu","year":"2018","journal-title":"spine J."},{"key":"B16","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1155\/2019\/5297950","article-title":"Traumatic atlantoaxial and fracture-related dislocation","volume":"2019","author":"Meyer","year":"2019","journal-title":"Biomed. Res. Int."},{"key":"B17","doi-asserted-by":"publisher","first-page":"1888","DOI":"10.1016\/j.spinee.2018.05.019","article-title":"Biomechanical comparison of cemented versus non-cemented anterior screw fixation in type II odontoid fractures in the elderly: a cadaveric study","volume":"18","author":"Rehousek","year":"2018","journal-title":"spine J."},{"key":"B18","doi-asserted-by":"publisher","first-page":"230949901987046","DOI":"10.1177\/2309499019870465","article-title":"Treatment of irreducible atlantoaxial dislocation using one-stage retropharyngeal release and posterior reduction","volume":"27","author":"Ren","year":"2019","journal-title":"J. Orthop. Surg. (Hong Kong)"},{"key":"B19","doi-asserted-by":"publisher","first-page":"573","DOI":"10.1097\/brs.0000000000001872","article-title":"Management of unusual atlantoaxial dislocation","volume":"42","author":"Song","year":"2017","journal-title":"Spine"},{"key":"B20","doi-asserted-by":"publisher","first-page":"767","DOI":"10.1016\/j.jbiomech.2014.12.019","article-title":"Four decades of finite element analysis of orthopaedic devices: where are we now and what are the opportunities?","volume":"48","author":"Taylor","year":"2015","journal-title":"J. biomechanics"},{"key":"B21","doi-asserted-by":"publisher","first-page":"228","DOI":"10.1055\/s-0041-1722838","article-title":"Atlantoaxial stabilization by posterior C1 and C2 screw-rod fixation for various pathologies: case series and comprehensive review of literature","volume":"12","author":"Unni","year":"2021","journal-title":"J. Neurosci. rural Pract."},{"key":"B22","doi-asserted-by":"publisher","first-page":"E306","DOI":"10.1097\/01.brs.0000217686.80327.e4","article-title":"Open reduction of irreducible atlantoaxial dislocation by transoral anterior atlantoaxial release and posterior internal fixation","volume":"31","author":"Wang","year":"2006","journal-title":"Spine"},{"key":"B23","doi-asserted-by":"publisher","first-page":"e474","DOI":"10.1016\/j.wneu.2019.03.174","article-title":"Biomechanical rationale for the development of atlantoaxial instability and basilar invagination in patients with occipitalization of the atlas: a finite element analysis","volume":"127","author":"Wang","year":"2019","journal-title":"World Neurosurg."},{"key":"B24","doi-asserted-by":"publisher","first-page":"55","DOI":"10.1016\/j.jot.2017.12.003","article-title":"Finite element analysis of biomechanical effects of total ankle arthroplasty on the foot","volume":"12","author":"Wang","year":"2018","journal-title":"J. Orthop. Transl."},{"key":"B25","doi-asserted-by":"publisher","first-page":"e95","DOI":"10.3928\/01477447-20121217-25","article-title":"New clinical classification system for atlantoaxial dislocation","volume":"36","author":"Xu","year":"2013","journal-title":"Orthopedics"},{"key":"B26","doi-asserted-by":"publisher","first-page":"E375","DOI":"10.1097\/01.brs.0000168374.84757.d5","article-title":"Irreducible anterior atlantoaxial dislocation: one-stage treatment with a transoral atlantoaxial reduction plate fixation and fusion. Report of 5 cases and review of the literature","volume":"30","author":"Yin","year":"2005","journal-title":"Spine"},{"key":"B27","doi-asserted-by":"publisher","first-page":"35","DOI":"10.1016\/j.jot.2019.12.006","article-title":"Population-based design and 3D finite element analysis of transforaminal thoracic interbody fusion cages","volume":"21","author":"Yu","year":"2020","journal-title":"J. Orthop. Transl."},{"key":"B28","doi-asserted-by":"publisher","first-page":"189","DOI":"10.1016\/j.jbiomech.2004.10.029","article-title":"Finite element analysis of moment-rotation relationships for human cervical spine","volume":"39","author":"Zhang","year":"2006","journal-title":"J. biomechanics"},{"key":"B29","doi-asserted-by":"publisher","first-page":"323","DOI":"10.3171\/2019.4.peds1928","article-title":"Management of pediatric patients with irreducible atlantoaxial dislocation: transoral anterior release, reduction, and fixation","volume":"24","author":"Zhu","year":"2019","journal-title":"J. Neurosurg. Pediatr."},{"key":"B30","doi-asserted-by":"publisher","first-page":"825","DOI":"10.1186\/s12891-020-03838-6","article-title":"Surgical treatment for basilar invagination with irreducible atlantoaxial dislocation: transoral atlantoaxial reduction plate fixation vs occipitocervical fixation","volume":"21","author":"Zou","year":"2020","journal-title":"BMC Musculoskelet. Disord."}],"container-title":["Frontiers in Bioengineering and Biotechnology"],"original-title":[],"link":[{"URL":"https:\/\/www.frontiersin.org\/articles\/10.3389\/fbioe.2024.1346850\/full","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2024,1,22]],"date-time":"2024-01-22T16:43:26Z","timestamp":1705941806000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.frontiersin.org\/articles\/10.3389\/fbioe.2024.1346850\/full"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2024,1,22]]},"references-count":30,"alternative-id":["10.3389\/fbioe.2024.1346850"],"URL":"https:\/\/doi.org\/10.3389\/fbioe.2024.1346850","relation":{},"ISSN":["2296-4185"],"issn-type":[{"value":"2296-4185","type":"electronic"}],"subject":[],"published":{"date-parts":[[2024,1,22]]},"article-number":"1346850"}}