{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,27]],"date-time":"2026-10-27T10:13:50Z","timestamp":1793096030171,"version":"4.5.0"},"reference-count":62,"publisher":"Frontiers Media SA","license":[{"start":{"date-parts":[[2024,7,23]],"date-time":"2024-07-23T00:00:00Z","timestamp":1721692800000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"content-domain":{"domain":["frontiersin.org"],"crossmark-restriction":true},"short-container-title":["Front. Bioeng. Biotechnol."],"abstract":"<jats:p><jats:bold>Introduction:<\/jats:bold> Bone healing can be improved by axial micromovement, as has been shown in animals and human patients with external fixators. In the development of smart fracture plates, the ideal amount of stroke for different fracture types in the different healing stages is currently unknown. It was hypothesized that the resulting strain in the fracture gap of a simple tibial shaft fracture does not vary with the amount of axial stroke in the plate, the fracture gap size, and the fracture angle.<\/jats:p><jats:p><jats:bold>Methods:<\/jats:bold> With finite element simulations based on body donation computed tomography data, the second invariant of the deviatoric strain tensor (J2), strain energy density, hydrostatic strain, octahedral shear strain, and percentage of the fracture gap in the \u201cperfect healing window\u201d were computed for different gap sizes (1\u20133\u00a0mm), angles (5\u00b0\u201360\u00b0), and plate stroke levels (0.05\u20130.60\u00a0mm) in three healing stages. Multiple linear regression analyses were performed.<\/jats:p><jats:p><jats:bold>Results:<\/jats:bold> Findings showed that an active fracture plate should deliver an axial stroke in the range of 0.10\u20130.45\u00a0mm. Different optimal stroke values were found for each healing phase, namely, 0.10\u20130.25\u00a0mm for the first, 0.10\u00a0mm for the second, and 0.35\u20130.45\u00a0mm for the third healing phase, depending on the fracture gap size and less on the fracture angle. J2, hydrostatic strain, octahedral shear strain and the strain energy density correlated with the fracture gap size and angle (all <jats:italic>p<\/jats:italic> &amp;lt; 0.001). The influence of the fracture gap size and angle on the variability (adjusted R<jats:sup>2<\/jats:sup>) in several outcome measures in the fracture gap was shown to vary throughout healing. The contribution to the variability of the percentage of the fracture gap in the perfect healing window was greatest during the second healing phase. For J2, strain energy density, hydrostatic strain, and octahedral shear strain, the fracture gap size showed the greatest contribution in the third fracture healing phase, while the influence of fracture angle was independent of the healing phase.<\/jats:p><jats:p><jats:bold>Discussion:<\/jats:bold> The present findings are relevant for implant development and to design clinical studies that aim to accelerate fracture healing using axial micromovement.<\/jats:p>","DOI":"10.3389\/fbioe.2024.1420047","type":"journal-article","created":{"date-parts":[[2024,7,23]],"date-time":"2024-07-23T05:04:20Z","timestamp":1721711060000},"update-policy":"https:\/\/doi.org\/10.3389\/crossmark-policy","source":"Crossref","is-referenced-by-count":10,"title":["Finite element simulations of smart fracture plates capable of cyclic shortening and lengthening: which stroke for which fracture?"],"prefix":"10.3389","volume":"12","author":[{"given":"Michael","family":"Roland","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Stefan","family":"Diebels","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Kerstin","family":"Wickert","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Tim","family":"Pohlemann","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Bergita","family":"Ganse","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"1965","published-online":{"date-parts":[[2024,7,23]]},"reference":[{"key":"B1","doi-asserted-by":"publisher","first-page":"e308","DOI":"10.1016\/S2589-7500(19)30128-1","article-title":"Innovative intelligent insole system reduces diabetic foot ulcer recurrence at plantar sites: a prospective, randomised, proof-of-concept study","volume":"1","author":"Abbott","year":"2019","journal-title":"Lancet Digit. Health"},{"key":"B2","doi-asserted-by":"publisher","first-page":"1011","DOI":"10.1016\/S0736-0266(03)00098-6","article-title":"Shear movement at the fracture site delays healing in a diaphyseal fracture model","volume":"21","author":"Augat","year":"2003","journal-title":"J. Orthop. Res."},{"key":"B3","doi-asserted-by":"publisher","first-page":"691","DOI":"10.3390\/biomedicines9060691","article-title":"Can optimizing the mechanical environment deliver a clinically significant reduction in fracture healing time?","volume":"9","author":"Barcik","year":"2021","journal-title":"Biomedicines"},{"key":"B4","doi-asserted-by":"publisher","first-page":"116834","DOI":"10.1016\/j.bone.2023.116834","article-title":"The absence of immediate stimulation delays bone healing","volume":"175","author":"Barcik","year":"2023","journal-title":"Bone"},{"key":"B5","first-page":"754","article-title":"In vivo comparison of early fracture healing under deviatoric and volumetric deformations","volume":"4","author":"Bishop","year":"2003","journal-title":"Acta Bioeng. Biomech."},{"key":"B6","doi-asserted-by":"publisher","first-page":"307","DOI":"10.1097\/01.blo.0000191272.34786.09","article-title":"Shear does not necessarily inhibit bone healing","volume":"443","author":"Bishop","year":"2006","journal-title":"Clin. Orthop. Relat. Res."},{"key":"B7","doi-asserted-by":"publisher","first-page":"749209","DOI":"10.3389\/fsurg.2021.749209","article-title":"Individualized determination of the mechanical fracture environment after tibial exchange nailing-A simulation-based feasibility study","volume":"8","author":"Braun","year":"2021","journal-title":"Front. Surg."},{"key":"B8","doi-asserted-by":"publisher","first-page":"203","DOI":"10.1243\/0954411011533760","article-title":"A three-dimensional finite element model from computed tomography data: a semi-automated method","volume":"215","author":"Cattaneo","year":"2001","journal-title":"Proc. Inst. Mech. Eng. H."},{"key":"B9","doi-asserted-by":"publisher","first-page":"255","DOI":"10.1016\/s0021-9290(98)00153-5","article-title":"Magnitudes of local stress and strain along bony surfaces predict the course and type of fracture healing","volume":"32","author":"Claes","year":"1999","journal-title":"J. Biomech."},{"key":"B10","doi-asserted-by":"publisher","first-page":"S132","DOI":"10.1097\/00003086-199810001-00015","article-title":"Effects of mechanical factors on the fracture healing process","volume":"355","author":"Claes","year":"1998","journal-title":"Clin. Orthop. Relat. Res."},{"key":"B11","doi-asserted-by":"publisher","first-page":"523","DOI":"10.1016\/0021-9290(93)90014-6","article-title":"Mechanical and textural properties of pelvic trabecular bone","volume":"26","author":"Dalstra","year":"1993","journal-title":"J. Biomech."},{"key":"B12","doi-asserted-by":"publisher","first-page":"1809","DOI":"10.1016\/j.engfracmech.2003.08.003","article-title":"Modelling bone tissue fracture and healing: a review","volume":"71","author":"Doblar\u00e9","year":"2004","journal-title":"Eng. Fract. Mech."},{"key":"B13","doi-asserted-by":"publisher","first-page":"875","DOI":"10.1016\/j.medengphy.2012.08.022","article-title":"An investigation to determine if a single validated density-elasticity relationship can be used for subject specific finite element analyses of human long bones","volume":"35","author":"Eberle","year":"2013","journal-title":"Med. Eng. Phys."},{"key":"B14","doi-asserted-by":"publisher","first-page":"1655","DOI":"10.1016\/j.jbiomech.2013.04.016","article-title":"Torsional stiffness and strength of the proximal tibia are better predicted by finite element models than DXA or QCT","volume":"46","author":"Edwards","year":"2013","journal-title":"J. Biomech."},{"key":"B15","doi-asserted-by":"publisher","first-page":"110192","DOI":"10.1016\/j.jbiomech.2020.110192","article-title":"Biphasic plating improves the mechanical performance of locked plating for distal femur fractures","volume":"115","author":"Epari","year":"2021","journal-title":"J. Biomech."},{"key":"B16","doi-asserted-by":"publisher","first-page":"S101","DOI":"10.1016\/j.injury.2020.09.026","article-title":"Smart implants in fracture care - only buzzword or real opportunity?","volume":"52","author":"Ernst","year":"2021","journal-title":"Injury"},{"key":"B17","doi-asserted-by":"publisher","first-page":"91","DOI":"10.1016\/j.medengphy.2021.11.002","article-title":"An engineering review of external fixators","volume":"98","author":"Fernando","year":"2021","journal-title":"Med. Eng. Phys."},{"key":"B18","doi-asserted-by":"publisher","first-page":"43","DOI":"10.1016\/j.injury.2020.06.044","article-title":"The influence of biomechanical stability on bone healing and fracture-related infection: the legacy of Stephan Perren","volume":"52","author":"Foster","year":"2021","journal-title":"Injury"},{"key":"B19","doi-asserted-by":"publisher","first-page":"2394","DOI":"10.1002\/jor.25583","article-title":"Effects of dynamization timing and degree on bone healing of different fracture types","volume":"41","author":"Fu","year":"2023","journal-title":"J. Orthop. Res."},{"key":"B20","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1016\/j.actbio.2022.05.001","article-title":"Concepts and clinical aspects of active implants for the treatment of bone fractures","volume":"146","author":"Ganse","year":"2022","journal-title":"Acta Biomater."},{"key":"B21","doi-asserted-by":"publisher","first-page":"1777","DOI":"10.1016\/j.injury.2016.06.003","article-title":"Partial weight bearing of the tibia","volume":"47","author":"Ganse","year":"2016","journal-title":"Injury"},{"key":"B22","first-page":"394","article-title":"A numerical model to study the mechanical influences on bone fracture healing","volume":"4","author":"Garcia","year":"2003","journal-title":"Acta Bioeng. Biomech."},{"key":"B23","doi-asserted-by":"publisher","first-page":"87","DOI":"10.1016\/j.bonr.2017.03.002","article-title":"Bone fracture healing in mechanobiological modeling: a review of principles and methods","volume":"6","author":"Ghiasi","year":"2017","journal-title":"Bone Rep."},{"key":"B24","doi-asserted-by":"publisher","first-page":"678","DOI":"10.3389\/fphys.2016.00678","article-title":"A concert between biology and biomechanics: the influence of the mechanical environment on bone healing","volume":"7","author":"Glatt","year":"2017","journal-title":"Front. Physiol."},{"key":"B25","doi-asserted-by":"publisher","first-page":"8","DOI":"10.1186\/1475-925X-2-8","article-title":"In vivo measurement of bending stiffness in fracture healing","volume":"2","author":"Hente","year":"2003","journal-title":"Biomed. Eng. Online"},{"key":"B26","doi-asserted-by":"publisher","first-page":"709","DOI":"10.1016\/j.orthres.2003.11.007","article-title":"The influence of cyclic compression and distraction on the healing of experimental tibial fractures","volume":"22","author":"Hente","year":"2004","journal-title":"J. Orthop. Res."},{"key":"B27","doi-asserted-by":"publisher","first-page":"105963","DOI":"10.1016\/j.archoralbio.2024.105963","article-title":"The role of the Piezo1 channel in osteoblasts under cyclic stretching: a study on osteogenic and osteoclast factors","volume":"163","author":"Kang","year":"2024","journal-title":"Arch. Oral Biol."},{"key":"B28","doi-asserted-by":"publisher","first-page":"36","DOI":"10.1097\/00003086-198904000-00006","article-title":"Controlled mechanical stimulation in the treatment of tibial fractures","volume":"241","author":"Kenwright","year":"1989","journal-title":"Clin. Orthop. Relat. Res."},{"key":"B29","doi-asserted-by":"publisher","first-page":"1185","DOI":"10.1016\/s0140-6736(86)92196-3","article-title":"Effect of controlled axial micromovement on healing of tibial fractures","volume":"2","author":"Kenwright","year":"1986","journal-title":"Lancet"},{"key":"B30","doi-asserted-by":"publisher","first-page":"28","DOI":"10.1097\/00003086-199308000-00005","article-title":"Tibial external fixation, weight bearing, and fracture movement","volume":"293","author":"Kershaw","year":"1993","journal-title":"Clin. Orthop. Relat. Res."},{"key":"B31","doi-asserted-by":"publisher","first-page":"36","DOI":"10.1186\/s40634-016-0072-2","article-title":"Quantitative Computed Tomography (QCT) derived Bone Mineral Density (BMD) in finite element studies: a review of the literature","volume":"3","author":"Knowles","year":"2016","journal-title":"J. Exp. Orthop."},{"key":"B32","doi-asserted-by":"publisher","first-page":"258","DOI":"10.1093\/icvts\/ivv403","article-title":"eComment. The importance of choosing a proper predictor variable selection method in logistic regression analyses","volume":"22","author":"Kucuk","year":"2016","journal-title":"Interact. Cardiovasc Thorac. Surg."},{"key":"B33","doi-asserted-by":"publisher","first-page":"41","DOI":"10.2147\/IEH.S133518","article-title":"Smart implants in orthopedic surgery, improving patient outcomes: a review","volume":"5","author":"Ledet","year":"2018","journal-title":"Innov. Entrep. Health"},{"key":"B34","first-page":"320","article-title":"Health care and productivity costs for isolated tibia shaft fracture admissions in The Netherlands","volume":"86","author":"Leliveld","year":"2020","journal-title":"Acta Orthop. Belg"},{"key":"B35","doi-asserted-by":"publisher","first-page":"551","DOI":"10.1016\/j.injury.2011.03.031","article-title":"The biology of fracture healing","volume":"42","author":"Marsell","year":"2011","journal-title":"Injury"},{"key":"B36","doi-asserted-by":"publisher","first-page":"100409","DOI":"10.1016\/j.pacs.2022.100409","article-title":"Photoacoustic imaging for the study of oxygen saturation and total hemoglobin in bone healing and non-union formation","volume":"28","author":"Menger","year":"","journal-title":"Photoacoustics"},{"key":"B37","doi-asserted-by":"publisher","first-page":"1100","DOI":"10.1016\/j.medengphy.2016.07.007","article-title":"Influence of fracture geometry on bone healing under locking plate fixations: a comparison between oblique and transverse tibial fractures","volume":"38","author":"Miramini","year":"2016","journal-title":"Med. Eng. Phys."},{"key":"B38","doi-asserted-by":"publisher","first-page":"075047","DOI":"10.1088\/1361-665X\/aac9e1","article-title":"High-speed and high-efficiency shape memory alloy actuation","volume":"27","author":"Motzki","year":"2018","journal-title":"Smart Mater. Struct."},{"key":"B39","doi-asserted-by":"publisher","first-page":"1752","DOI":"10.1080\/10255842.2021.1919883","article-title":"Prediction of interfragmentary movement in fracture fixation constructs using a combination of finite element modeling and rigid body assumptions","volume":"24","author":"M\u00fchling","year":"2021","journal-title":"Comput. Methods Biomech. Biomed. Engin"},{"key":"B40","doi-asserted-by":"publisher","first-page":"663","DOI":"10.1016\/j.injury.2008.10.035","article-title":"The influence of osteoporosis in femoral fracture healing time","volume":"40","author":"Nikolaou","year":"2009","journal-title":"Injury"},{"key":"B41","doi-asserted-by":"publisher","first-page":"1067845","DOI":"10.3389\/fbioe.2023.1067845","article-title":"Simulation-based prediction of bone healing and treatment recommendations for lower leg fractures: effects of motion, weight-bearing and fibular mechanics","volume":"11","author":"Orth","year":"2023","journal-title":"Front. Bioeng. Biotechnol."},{"key":"B42","doi-asserted-by":"publisher","first-page":"347","DOI":"10.1016\/1350-4533(95)97314-F","article-title":"Relations of mechanical properties to density and CT numbers in human bone","volume":"17","author":"Rho","year":"1995","journal-title":"Med. Eng. Phys."},{"key":"B43","doi-asserted-by":"publisher","first-page":"20450","DOI":"10.1038\/s41598-023-47910-2","article-title":"Reappraisal of clinical trauma trials: the critical impact of anthropometric parameters on fracture gap micro-mechanics-observations from a simulation-based study","volume":"13","author":"Roland","year":"2023","journal-title":"Sci. Rep."},{"key":"B44","doi-asserted-by":"publisher","first-page":"247","DOI":"10.1007\/s00264-017-3734-5","article-title":"Diaphyseal long bone nonunions - types, aetiology, economics, and treatment recommendations","volume":"42","author":"Rupp","year":"2018","journal-title":"Int. Orthop."},{"key":"B45","doi-asserted-by":"publisher","first-page":"85","DOI":"10.3390\/bioengineering10010085","article-title":"Bone healing gone wrong: pathological fracture healing and non-unions-overview of basic and clinical aspects and systematic review of risk factors","volume":"10","author":"Saul","year":"2023","journal-title":"Bioeng. (Basel)"},{"key":"B46","doi-asserted-by":"publisher","first-page":"398","DOI":"10.1302\/0301-620X.94B3.27550","article-title":"Telemetric assessment of bone healing with an instrumented internal fixator: a preliminary study","volume":"94","author":"Seide","year":"2012","journal-title":"J. Bone Jt. Surg. Br."},{"key":"B47","doi-asserted-by":"publisher","first-page":"2440","DOI":"10.1016\/j.jbiomech.2004.10.019","article-title":"Trabecular bone fracture healing simulation with finite element analysis and fuzzy logic","volume":"38","author":"Shefelbine","year":"2005","journal-title":"J. Biomech."},{"key":"B48","doi-asserted-by":"publisher","first-page":"1152","DOI":"10.1016\/j.injury.2010.08.018","article-title":"The influence of compression on the healing of experimental tibial fractures","volume":"42","author":"Sigurdsen","year":"2011","journal-title":"Injury"},{"key":"B49","doi-asserted-by":"publisher","first-page":"79","DOI":"10.1080\/10255842.2010.499865","article-title":"A numerical model of the fracture healing process that describes tissue development and revascularisation","volume":"14","author":"Simon","year":"2011","journal-title":"Comput. Methods Biomech. Biomed. Engin"},{"key":"B50","doi-asserted-by":"publisher","first-page":"459","DOI":"10.1142\/S2424835522500461","article-title":"The effect of hand dominance, age, gender, fracture comminution and ASA status on time to fracture healing following surgical fixation of distal radius fractures","volume":"27","author":"Tang","year":"2022","journal-title":"J. Hand Surg. Asian Pac"},{"key":"B51","doi-asserted-by":"publisher","first-page":"255","DOI":"10.3390\/bioengineering10020255","article-title":"Gait analysis to monitor fracture healing of the lower leg","volume":"10","author":"Warmerdam","year":"2023","journal-title":"Bioeng. (Basel)"},{"key":"B52","doi-asserted-by":"publisher","first-page":"1355254","DOI":"10.3389\/fbioe.2024.1355254","article-title":"Long-term continuous instrumented insole-based gait analyses in daily life have advantages over longitudinal gait analyses in the lab to monitor healing of tibial fractures","volume":"12","author":"Warmerdam","year":"2024","journal-title":"Front. Bioeng. Biotechnol."},{"key":"B53","doi-asserted-by":"publisher","first-page":"1425","DOI":"10.1016\/0021-9290(92)90056-7","article-title":"The behavior of adaptive bone-remodeling simulation models","volume":"25","author":"Weinans","year":"1992","journal-title":"J. Biomech."},{"key":"B54","doi-asserted-by":"publisher","first-page":"1370837","DOI":"10.3389\/fbioe.2024.1370837","article-title":"Experimental and virtual testing of bone-implant systems equipped with the AO Fracture Monitor with regard to interfragmentary movement","volume":"12","author":"Wickert","year":"2024","journal-title":"Front. Bioeng. Biotech."},{"key":"B55","doi-asserted-by":"publisher","first-page":"858","DOI":"10.3390\/medicina58070858","article-title":"Continuous implant load monitoring to assess bone healing status-evidence from animal testing","volume":"58","author":"Windolf","year":"2022","journal-title":"Med. Kaunas."},{"key":"B56","doi-asserted-by":"publisher","first-page":"805","DOI":"10.2106\/00004623-198163050-00016","article-title":"Comparison of cyclic loading versus constant compression in the treatment of long-bone fractures in rabbits","volume":"63","author":"Wolf","year":"1981","journal-title":"J. Bone Jt. Surg. Am."},{"key":"B57","doi-asserted-by":"publisher","first-page":"359","DOI":"10.1016\/s0268-0033(98)00097-7","article-title":"The effects of external mechanical stimulation on the healing of diaphyseal osteotomies fixed by flexible external fixation","volume":"13","author":"Wolf","year":"1998","journal-title":"Clin. Biomech. Bristol, Avon."},{"key":"B58","doi-asserted-by":"publisher","first-page":"1110099","DOI":"10.3389\/fbioe.2023.1110099","article-title":"Effects of age, body height, body weight, body mass index and handgrip strength on the trajectory of the plantar pressure stance-phase curve of the gait cycle","volume":"11","author":"Wolff","year":"2023","journal-title":"Front. Bioeng. Biotechnol."},{"key":"B59","doi-asserted-by":"publisher","first-page":"456","DOI":"10.1016\/j.jbiomech.2014.12.031","article-title":"On the relationship between tibia torsional deformation and regional muscle contractions in habitual human exercises in vivo","volume":"48","author":"Yang","year":"2015","journal-title":"J. Biomech."},{"key":"B60","doi-asserted-by":"publisher","first-page":"e94525","DOI":"10.1371\/journal.pone.0094525","article-title":"Torsion and antero-posterior bending in the in-vivo human tibia loading regimes during walking and running","volume":"9","author":"Yang","year":"2014","journal-title":"PLOS ONE"},{"key":"B61","doi-asserted-by":"publisher","first-page":"833","DOI":"10.3390\/bios13080833","article-title":"Insole systems for disease diagnosis and rehabilitation: a review","volume":"13","author":"Zhang","year":"2023","journal-title":"Biosens. (Basel)."},{"key":"B62","doi-asserted-by":"publisher","first-page":"e162775","DOI":"10.1001\/jamasurg.2016.2775","article-title":"Epidemiology of fracture nonunion in 18 human bones","volume":"151","author":"Zura","year":"2016","journal-title":"JAMA Surg."}],"container-title":["Frontiers in Bioengineering and Biotechnology"],"original-title":[],"link":[{"URL":"https:\/\/www.frontiersin.org\/articles\/10.3389\/fbioe.2024.1420047\/full","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2024,7,23]],"date-time":"2024-07-23T05:04:23Z","timestamp":1721711063000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.frontiersin.org\/articles\/10.3389\/fbioe.2024.1420047\/full"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2024,7,23]]},"references-count":62,"alternative-id":["10.3389\/fbioe.2024.1420047"],"URL":"https:\/\/doi.org\/10.3389\/fbioe.2024.1420047","relation":{},"ISSN":["2296-4185"],"issn-type":[{"value":"2296-4185","type":"electronic"}],"subject":[],"published":{"date-parts":[[2024,7,23]]},"article-number":"1420047"}}