{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,9,18]],"date-time":"2026-09-18T19:59:10Z","timestamp":1789761550376,"version":"4.0.1"},"reference-count":65,"publisher":"Frontiers Media SA","license":[{"start":{"date-parts":[[2024,8,20]],"date-time":"2024-08-20T00:00:00Z","timestamp":1724112000000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"funder":[{"DOI":"10.13039\/100004917","name":"Cancer Prevention and Research Institute of Texas","doi-asserted-by":"publisher","id":[{"id":"10.13039\/100004917","id-type":"DOI","asserted-by":"publisher"}]}],"content-domain":{"domain":["frontiersin.org"],"crossmark-restriction":true},"short-container-title":["Front. Bioeng. Biotechnol."],"abstract":"<jats:p><jats:bold>Introduction:<\/jats:bold> Three-dimensional (3D)-printed custom pelvic implants have become a clinically viable option for patients undergoing pelvic cancer surgery with resection of the hip joint. However, increased clinical utilization has also necessitated improved implant durability, especially with regard to the compression screws used to secure the implant to remaining pelvic bone. This study evaluated six different finite element (FE) screw modeling methods for predicting compression screw pullout and fatigue failure in a custom pelvic implant secured to bone using nine compression screws.<\/jats:p><jats:p><jats:bold>Methods:<\/jats:bold> Three modeling methods (tied constraints (TIE), bolt load with constant force (BL-CF), and bolt load with constant length (BL-CL)) generated screw axial forces using functionality built into Abaqus FE software; while the remaining three modeling methods (isotropic pseudo-thermal field (ISO), orthotropic pseudo-thermal field (ORT), and equal-and-opposite force field (FOR)) generated screw axial forces using iterative physics-based relationships that can be implemented in any FE software. The ability of all six modeling methods to match specified screw pretension forces and predict screw pullout and fatigue failure was evaluated using an FE model of a custom pelvic implant with total hip replacement. The applied hip contact forces in the FE model were estimated at two locations in a gait cycle. For each of the nine screws in the custom implant FE model, likelihood of screw pullout failure was predicted using maximum screw axial force, while likelihood of screw fatigue failure was predicted using maximum von Mises stress.<\/jats:p><jats:p><jats:bold>Results:<\/jats:bold> The three iterative physics-based modeling methods and the non-iterative Abaqus BL-CL method produced nearly identical predictions for likelihood of screw pullout and fatigue failure, while the other two built-in Abaqus modeling methods yielded vastly different predictions. However, the Abaqus BL-CL method required the least computation time, largely because an iterative process was not needed to induce specified screw pretension forces. Of the three iterative methods, FOR required the fewest iterations and thus the least computation time.<\/jats:p><jats:p><jats:bold>Discussion:<\/jats:bold> These findings suggest that the BL-CL screw modeling method is the best option when Abaqus is used for predicting screw pullout and fatigue failure in custom pelvis prostheses, while the iterative physics-based FOR method is the best option if FE software other than Abaqus is used.<\/jats:p>","DOI":"10.3389\/fbioe.2024.1420870","type":"journal-article","created":{"date-parts":[[2024,8,20]],"date-time":"2024-08-20T05:01:21Z","timestamp":1724130081000},"update-policy":"https:\/\/doi.org\/10.3389\/crossmark-policy","source":"Crossref","is-referenced-by-count":5,"title":["Evaluation of finite element modeling methods for predicting compression screw failure in a custom pelvic implant"],"prefix":"10.3389","volume":"12","author":[{"given":"Yuhui","family":"Zhu","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Ata","family":"Babazadeh-Naseri","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Matthew R. W.","family":"Brake","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"John E.","family":"Akin","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Geng","family":"Li","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Valerae O.","family":"Lewis","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Benjamin J.","family":"Fregly","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"1965","published-online":{"date-parts":[[2024,8,20]]},"reference":[{"key":"B1","doi-asserted-by":"publisher","first-page":"319","DOI":"10.1016\/j.prosdent.2004.01.016","article-title":"Influence of occlusal forces on stress distribution in preloaded dental implant screws","volume":"91","author":"Alkan","year":"2004","journal-title":"J. Prosthet. Dent."},{"key":"B2","doi-asserted-by":"publisher","first-page":"364","DOI":"10.1115\/1.1894148","article-title":"Subject-specific finite element model of the pelvis: development, validation and sensitivity studies","volume":"127","author":"Anderson","year":"2005","journal-title":"J. Biomech. Eng."},{"key":"B3","doi-asserted-by":"publisher","first-page":"123","DOI":"10.1007\/s00264-018-4232-0","article-title":"Three-dimension-printed custom-made prosthetic reconstructions: from revision surgery to oncologic reconstructions","volume":"43","author":"Angelini","year":"2019","journal-title":"Int. Orthop. (SICOT)"},{"key":"B4","doi-asserted-by":"publisher","first-page":"962959","DOI":"10.3389\/fbioe.2022.962959","article-title":"EMG-driven musculoskeletal model calibration with estimation of unmeasured muscle excitations via synergy extrapolation","volume":"10","author":"Ao","year":"2022","journal-title":"Front. Bioeng. Biotechnol."},{"key":"B5","volume-title":"Verification, validation, and uncertainty quantification terminology in computational modeling and simulation","year":"2022"},{"key":"B6","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1016\/j.medengphy.2021.07.012","article-title":"Heterogeneous material mapping methods for patient-specific finite element models of pelvic trabecular bone: a convergence study","volume":"96","author":"Babazadeh Naseri","year":"2021","journal-title":"Med. Eng. and Phys."},{"key":"B7","doi-asserted-by":"publisher","first-page":"106615","DOI":"10.1016\/j.ymssp.2020.106615","article-title":"Traction-based multi-scale nonlinear dynamic modeling of bolted joints: formulation, application, and trends in micro-scale interface evolution","volume":"139","author":"Balaji","year":"2020","journal-title":"Mech. Syst. Signal Process."},{"key":"B8","doi-asserted-by":"publisher","first-page":"859","DOI":"10.1016\/S0021-9290(01)00040-9","article-title":"Hip contact forces and gait patterns from routine activities","volume":"34","author":"Bergmann","year":"2001","journal-title":"J. Biomechanics"},{"key":"B9","doi-asserted-by":"publisher","first-page":"65","DOI":"10.3233\/BME-2010-0616","article-title":"Realistic loads for testing hip implants","volume":"20","author":"Bergmann","year":"2010","journal-title":"Bio-Medical Mater. Eng."},{"key":"B10","doi-asserted-by":"publisher","first-page":"872","DOI":"10.1016\/j.clinbiomech.2012.06.009","article-title":"Clinical implementation of finite element models in pelvic ring surgery for prediction of implant behavior: a case report","volume":"27","author":"B\u00f6hme","year":"2012","journal-title":"Clin. Biomech."},{"key":"B11","doi-asserted-by":"publisher","first-page":"905","DOI":"10.1177\/11207000221135068","article-title":"Custom designed and 3D-printed titanium pelvic implants for acetabular reconstruction after tumour resection","volume":"33","author":"Broekhuis","year":"2022","journal-title":"Hip Int."},{"key":"B12","first-page":"286","volume-title":"Shigley\u2019s mechanical engineering design","author":"Budynas","year":"2011"},{"key":"B13","doi-asserted-by":"publisher","first-page":"391","DOI":"10.1115\/1.2796022","article-title":"Factors affecting the pullout strength of cancellous bone screws","volume":"118","author":"Chapman","year":"1996","journal-title":"J. Biomechanical Eng."},{"key":"B14","doi-asserted-by":"publisher","first-page":"030006052091727","DOI":"10.1177\/0300060520917275","article-title":"Three-dimensional printed implant for reconstruction of pelvic bone after removal of giant chondrosarcoma: a case report","volume":"48","author":"Chen","year":"2020","journal-title":"J. Int. Med. Res."},{"key":"B15","doi-asserted-by":"publisher","first-page":"715","DOI":"10.1016\/0021-9290(94)00125-N","article-title":"Load transfer across the pelvic bone","volume":"28","author":"Dalstra","year":"1995","journal-title":"J. Biomechanics"},{"key":"B16","doi-asserted-by":"publisher","first-page":"1550015","DOI":"10.1142\/S0218957715500153","article-title":"An investigation into the frictional properties between bone and various orthopedic implant surfaces \u2014 implant stability","volume":"18","author":"Dannaway","year":"2015","journal-title":"J. Musculoskelet. Res."},{"key":"B17","doi-asserted-by":"publisher","first-page":"1940","DOI":"10.1109\/TBME.2007.901024","article-title":"OpenSim: open-source software to create and analyze dynamic simulations of movement","volume":"54","author":"Delp","year":"2007","journal-title":"IEEE Trans. Biomed. Eng."},{"key":"B18","volume-title":"DIN 946, Determination of coefficient of friction of bolt-nut assemblies under specified conditions","year":"1991"},{"key":"B19","doi-asserted-by":"publisher","first-page":"105103","DOI":"10.1016\/j.jmbbm.2022.105103","article-title":"Predicting friction at the bone \u2013 implant interface in cementless total knee arthroplasty","volume":"128","author":"de Vries","year":"2022","journal-title":"J. Mech. Behav. Biomed. Mater."},{"key":"B20","doi-asserted-by":"publisher","first-page":"1092","DOI":"10.1007\/s42235-019-0121-5","article-title":"Preclinical strength checking for artificial pelvic prosthesis under multi-activities - a case study","volume":"16","author":"Dong","year":"2019","journal-title":"J. Bionic Eng."},{"key":"B21","doi-asserted-by":"publisher","first-page":"443","DOI":"10.1007\/s42235-018-0035-7","article-title":"Finite element analysis of the pelvis after customized prosthesis reconstruction","volume":"15","author":"Dong","year":"2018","journal-title":"J. Bionic Eng."},{"key":"B22","doi-asserted-by":"publisher","first-page":"535","DOI":"10.1016\/S8756-3282(97)00196-8","article-title":"Nondestructive determination of iliac crest cancellous bone strength by pQCT","volume":"21","author":"Ebbesen","year":"1997","journal-title":"Bone"},{"key":"B23","doi-asserted-by":"publisher","first-page":"e0220564","DOI":"10.1371\/journal.pone.0220564","article-title":"Calibration with or without phantom for fracture risk prediction in cancer patients with femoral bone metastases using CT-based finite element models","volume":"14","author":"Eggermont","year":"2019","journal-title":"PLOS ONE"},{"key":"B24","doi-asserted-by":"publisher","first-page":"103866","DOI":"10.1016\/j.jmbbm.2020.103866","article-title":"Empirical relationships between bone density and ultimate strength: a literature review","volume":"110","author":"Fleps","year":"2020","journal-title":"J. Mech. Behav. Biomed. Mater."},{"key":"B25","doi-asserted-by":"publisher","first-page":"40","DOI":"10.1016\/j.clinbiomech.2019.07.009","article-title":"Non-locking screw insertion: No benefit seen if tightness exceeds 80% of the maximum torque","volume":"70","author":"Fletcher","year":"2019","journal-title":"Clin. Biomech."},{"key":"B26","doi-asserted-by":"publisher","first-page":"183","DOI":"10.1016\/S0022-3913(08)60177-8","article-title":"Probabilistic analysis of preload in the abutment screw of a dental implant complex","volume":"100","author":"Guda","year":"2008","journal-title":"J. Prosthet. Dent."},{"key":"B27","doi-asserted-by":"publisher","first-page":"1036882","DOI":"10.3389\/fbioe.2022.1036882","article-title":"Reconstruction with 3D-printed prostheses after type I + II + III internal hemipelvectomy: finite element analysis and preliminary outcomes","volume":"10","author":"Guo","year":"2023","journal-title":"Front. Bioeng. Biotechnol."},{"key":"B28","doi-asserted-by":"publisher","first-page":"101006","DOI":"10.1115\/1.4005223","article-title":"The effect of boundary condition on the biomechanics of a human pelvic joint under an axial compressive load: a three-dimensional finite element model","volume":"133","author":"Hao","year":"2011","journal-title":"J. Biomechanical Eng."},{"key":"B29","doi-asserted-by":"publisher","first-page":"1321","DOI":"10.1097\/01.brs.0000218478.70656.63","article-title":"Stress relaxation at the bone\u2013pedicle screw interface in human bone","volume":"31","author":"Inceoglu","year":"2006","journal-title":"Spine"},{"key":"B30","doi-asserted-by":"publisher","first-page":"525","DOI":"10.1177\/0954411917692009","article-title":"Development of finite element model for customized prostheses design for patient with pelvic bone tumor","volume":"231","author":"Iqbal","year":"2017","journal-title":"Proc. Inst. Mech. Eng. H."},{"key":"B31","doi-asserted-by":"publisher","first-page":"29","DOI":"10.21037\/aoj.2019.06.01","article-title":"The evolution of pelvic endoprosthetic reconstruction after tumor resection","volume":"4","author":"Ji","year":"2019","journal-title":"Ann. Jt."},{"key":"B32","doi-asserted-by":"publisher","first-page":"1530","DOI":"10.2106\/JBJS.19.01437","article-title":"3D-Printed modular hemipelvic endoprosthetic reconstruction following periacetabular tumor resection: early results of 80 consecutive cases","volume":"102","author":"Ji","year":"2020","journal-title":"J. Bone Jt. Surg."},{"key":"B33","doi-asserted-by":"publisher","first-page":"109348","DOI":"10.1016\/j.jbiomech.2019.109348","article-title":"Static optimization underestimates antagonist muscle activity at the glenohumeral joint: a musculoskeletal modeling study","volume":"97","author":"Kian","year":"2019","journal-title":"J. Biomech."},{"key":"B34","doi-asserted-by":"publisher","first-page":"539","DOI":"10.1016\/j.prosdent.2003.09.012","article-title":"Finite element analysis to determine implant preload","volume":"90","author":"Lang","year":"2003","journal-title":"J. Prosthet. Dent."},{"key":"B35","doi-asserted-by":"publisher","first-page":"451","DOI":"10.3928\/0147-7447-20010501-12","article-title":"Effect of insertion torque on bone screw pullout strength","volume":"24","author":"Lawson","year":"2001","journal-title":"Orthopedics"},{"key":"B36","doi-asserted-by":"publisher","first-page":"964359","DOI":"10.3389\/fbioe.2022.964359","article-title":"A computational method for estimating trunk muscle activations during gait using lower extremity muscle synergies","volume":"10","author":"Li","year":"2022","journal-title":"Front. Bioeng. Biotechnol."},{"key":"B37","doi-asserted-by":"publisher","first-page":"1389031","DOI":"10.3389\/fbioe.2024.1389031","article-title":"Changes in walking function and neural control following pelvic cancer surgery with reconstruction","volume":"12","author":"Li","year":"2024","journal-title":"Front. Bioeng. Biotechnol."},{"key":"B38","doi-asserted-by":"publisher","first-page":"1452","DOI":"10.1007\/s10439-006-9145-1","article-title":"Three-dimensional finite element models of the human pubic symphysis with viscohyperelastic soft tissues","volume":"34","author":"Li","year":"2006","journal-title":"Ann. Biomed. Eng."},{"key":"B39","doi-asserted-by":"publisher","first-page":"267","DOI":"10.1302\/0301-620X.99B2.BJJ-2016-0654.R1","article-title":"Reconstruction with 3D-printed pelvic endoprostheses after resection of a pelvic tumour","author":"Liang","year":"2017","journal-title":"Bone and Jt. J."},{"key":"B40","doi-asserted-by":"publisher","first-page":"552","DOI":"10.1177\/1350650112441908","article-title":"Computational modelling of polyethylene wear and creep in total hip joint replacements: effect of the bearing clearance and diameter","volume":"226","author":"Liu","year":"2012","journal-title":"Proc. Institution Mech. Eng. Part J J. Eng. Tribol."},{"key":"B41","first-page":"224","volume-title":"Mechanical behavior of engineering materials","author":"Marin","year":"1962"},{"key":"B42","doi-asserted-by":"publisher","first-page":"7066","DOI":"10.3390\/ma14227066","article-title":"Finite element analysis of customized acetabular implant and bone after pelvic tumour resection throughout the gait cycle","volume":"14","author":"Maslov","year":"2021","journal-title":"Materials"},{"key":"B43","doi-asserted-by":"publisher","first-page":"119","DOI":"10.1146\/annurev-bioeng-062117-121139","article-title":"Bone mechanical properties in healthy and diseased states","volume":"20","author":"Morgan","year":"2018","journal-title":"Annu. Rev. Biomed. Eng."},{"key":"B44","doi-asserted-by":"publisher","first-page":"30","DOI":"10.1016\/j.jmbbm.2007.07.001","article-title":"Mechanical biocompatibilities of titanium alloys for biomedical applications","volume":"1","author":"Niinomi","year":"2008","journal-title":"J. Mech. Behav. Biomed. Mater."},{"key":"B45","doi-asserted-by":"crossref","first-page":"179","DOI":"10.1007\/978-3-662-46836-4_8","article-title":"Titanium alloys for biomedical applications","volume-title":"Advances in metallic biomaterials: tissues, materials and biological reactions","author":"Niinomi","year":"2015"},{"key":"B46","doi-asserted-by":"publisher","first-page":"197","DOI":"10.1097\/00003086-200203000-00030","article-title":"Implantation of hemipelvic prosthesis after resection of sarcoma","volume":"396","author":"Ozaki","year":"2002","journal-title":"Clin. Orthop. Relat. Research\u00ae"},{"key":"B47","doi-asserted-by":"publisher","first-page":"820","DOI":"10.3390\/app9050820","article-title":"Biomechanical evaluation of a new fixation type in 3D-printed periacetabular implants using a finite element simulation","volume":"9","author":"Park","year":"2019","journal-title":"Appl. Sci."},{"key":"B48","doi-asserted-by":"publisher","first-page":"739","DOI":"10.1016\/j.medengphy.2006.08.010","article-title":"Finite element modelling of the pelvis: inclusion of muscular and ligamentous boundary conditions","volume":"29","author":"Phillips","year":"2007","journal-title":"Med. Eng. and Phys."},{"key":"B49","doi-asserted-by":"publisher","first-page":"2068","DOI":"10.1109\/TBME.2016.2586891","article-title":"Full-body musculoskeletal model for muscle-driven simulation of human gait","volume":"63","author":"Rajagopal","year":"2016","journal-title":"IEEE Trans. Biomed. Eng."},{"key":"B50","doi-asserted-by":"publisher","first-page":"2513","DOI":"10.1016\/j.jbiomech.2012.07.023","article-title":"Shear strength behavior of human trabecular bone","volume":"45","author":"Sanyal","year":"2012","journal-title":"J. Biomech."},{"key":"B51","doi-asserted-by":"publisher","first-page":"100010","DOI":"10.1016\/j.jfscie.2022.100010","article-title":"Effects of abutment screw preload and preload simulation techniques on dental implant lifetime","volume":"1","author":"Satpathy","year":"2022","journal-title":"JADA Found. Sci."},{"key":"B52","doi-asserted-by":"publisher","first-page":"e1006223","DOI":"10.1371\/journal.pcbi.1006223","article-title":"OpenSim: simulating musculoskeletal dynamics and neuromuscular control to study human and animal movement","volume":"14","author":"Seth","year":"2018","journal-title":"PLOS Comput. Biol."},{"key":"B53","doi-asserted-by":"publisher","first-page":"553","DOI":"10.1111\/ans.12895","article-title":"Internal hemipelvectomy with reconstruction for primary pelvic neoplasm: a systematic review","volume":"85","author":"Shao","year":"2015","journal-title":"ANZ J. Surg."},{"key":"B54","unstructured":"Engineering fundamentals of threaded fastener design and analysis\n            ShobergR. S.\n          2000"},{"key":"B55","doi-asserted-by":"publisher","first-page":"398","DOI":"10.3390\/ma16010398","article-title":"Acetabular implant finite element simulation with customised estimate of bone properties","volume":"16","author":"Soloviev","year":"2023","journal-title":"Materials"},{"key":"B56","doi-asserted-by":"publisher","first-page":"1508","DOI":"10.1016\/j.arth.2011.02.018","article-title":"Clinical effectiveness of hemipelvic reconstruction using computer-aided custom-made prostheses after resection of malignant pelvic tumors","volume":"26","author":"Sun","year":"2011","journal-title":"J. Arthroplasty"},{"key":"B57","doi-asserted-by":"publisher","first-page":"2253","DOI":"10.1007\/s00264-015-2891-7","article-title":"A novel combined hemipelvic endoprosthesis for peri-acetabular tumours involving sacroiliac joint: a finite element study","volume":"39","author":"Wang","year":"2015","journal-title":"Int. Orthop. (SICOT)"},{"key":"B58","doi-asserted-by":"publisher","first-page":"389","DOI":"10.1186\/s13018-019-1455-8","article-title":"Three-dimensional-printed custom-made hemipelvic endoprosthesis for primary malignancies involving acetabulum: the design solution and surgical techniques","volume":"14","author":"Wang","year":"2019","journal-title":"J. Orthop. Surg. Res."},{"key":"B59","doi-asserted-by":"publisher","first-page":"357","DOI":"10.1186\/s12893-022-01804-8","article-title":"3D-printed hemipelvic prosthesis combined with a dual mobility bearing in patients with primary malignant neoplasm involving the acetabulum: clinical outcomes and finite element analysis","volume":"22","author":"Wang","year":"2022","journal-title":"BMC Surg."},{"key":"B60","doi-asserted-by":"publisher","first-page":"48","DOI":"10.1016\/j.medengphy.2017.02.001","article-title":"The effect of boundary constraints on finite element modelling of the human pelvis","volume":"43","author":"Watson","year":"2017","journal-title":"Med. Eng. and Phys."},{"key":"B61","doi-asserted-by":"publisher","first-page":"935059","DOI":"10.3389\/fonc.2022.935059","article-title":"Reconstruction of tumor-induced pelvic defects with customized, three-dimensional printed prostheses","volume":"12","author":"Xu","year":"2022","journal-title":"Front. Oncol."},{"key":"B62","doi-asserted-by":"publisher","first-page":"54","DOI":"10.1109\/MPUL.2017.2701493","article-title":"ITK-SNAP: an intractive medical image segmentation tool to meet the need for expert-guided segmentation of complex medical images","volume":"8","author":"Yushkevich","year":"2017","journal-title":"IEEE Pulse"},{"key":"B63","doi-asserted-by":"publisher","first-page":"892385","DOI":"10.3389\/fbioe.2022.892385","article-title":"Improving the stability of a hemipelvic prosthesis based on bone mineral density screw channel and prosthesis optimization design","volume":"10","author":"Zhou","year":"2022","journal-title":"Front. Bioeng. Biotechnol."},{"key":"B64","doi-asserted-by":"publisher","first-page":"653","DOI":"10.1007\/s00264-012-1756-6","article-title":"Finite element analysis of the pelvis after modular hemipelvic endoprosthesis reconstruction","volume":"37","author":"Zhou","year":"2013","journal-title":"Int. Orthop."},{"key":"B65","doi-asserted-by":"publisher","first-page":"103930","DOI":"10.1016\/j.medengphy.2022.103930","article-title":"Finite element analysis of screw fixation durability under multiple boundary and loading conditions for a custom pelvic implant","volume":"111","author":"Zhu","year":"2023","journal-title":"Med. Eng. and Phys."}],"container-title":["Frontiers in Bioengineering and Biotechnology"],"original-title":[],"link":[{"URL":"https:\/\/www.frontiersin.org\/articles\/10.3389\/fbioe.2024.1420870\/full","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2024,8,20]],"date-time":"2024-08-20T05:01:28Z","timestamp":1724130088000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.frontiersin.org\/articles\/10.3389\/fbioe.2024.1420870\/full"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2024,8,20]]},"references-count":65,"alternative-id":["10.3389\/fbioe.2024.1420870"],"URL":"https:\/\/doi.org\/10.3389\/fbioe.2024.1420870","relation":{},"ISSN":["2296-4185"],"issn-type":[{"value":"2296-4185","type":"electronic"}],"subject":[],"published":{"date-parts":[[2024,8,20]]},"article-number":"1420870"}}