{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,1]],"date-time":"2026-10-01T22:24:45Z","timestamp":1790893485765,"version":"4.1.0"},"reference-count":27,"publisher":"Frontiers Media SA","license":[{"start":{"date-parts":[[2025,2,25]],"date-time":"2025-02-25T00:00:00Z","timestamp":1740441600000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"content-domain":{"domain":["frontiersin.org"],"crossmark-restriction":true},"short-container-title":["Front. Bioeng. Biotechnol."],"abstract":"<jats:p>Robotic-assisted dental implantation represents a transformative innovation in modern dentistry, offering enhanced surgical precision and reduced variability. Despite its clinical adoption, the impact of anatomical and bone-related factors on placement accuracy remains underexplored. This retrospective study evaluated 54 implants placed in 30 patients using cone-beam computed tomography (CBCT) and virtual planning software to analyze deviations in crown position, apex position, and angulation. Significant regional variations in accuracy were observed, with higher angular deviations in the anterior maxilla (mean \u00b1 SD: 3.21\u00b0 \u00b1 2.22\u00b0) and greater positional deviations in the posterior mandible (1.09\u00a0mm \u00b1 0.51\u00a0mm) (<jats:italic>p<\/jats:italic> &amp;lt; 0.05). Implant diameter significantly influenced global deviation (<jats:italic>p<\/jats:italic> = 0.019), while implant length and bone density (classified by Misch\u2019s system) showed no significant effects (<jats:italic>p<\/jats:italic> &amp;gt; 0.05). However, denser bone types (D1) exhibited a trend toward increased deviations, potentially due to insertion resistance. These findings underscore the need for region-specific and bone-quality considerations in robotic-assisted implantation. Refining robotic navigation and feedback mechanisms is critical to optimizing accuracy, particularly in anatomically complex regions.<\/jats:p>","DOI":"10.3389\/fbioe.2025.1536957","type":"journal-article","created":{"date-parts":[[2025,2,25]],"date-time":"2025-02-25T06:56:25Z","timestamp":1740466585000},"update-policy":"https:\/\/doi.org\/10.3389\/crossmark-policy","source":"Crossref","is-referenced-by-count":7,"title":["The impact of jawbone regions (molar area, premolar area, anterior area) and bone density on the accuracy of robot-assisted dental implantation: a preliminary study"],"prefix":"10.3389","volume":"13","author":[{"given":"Mirealimu","family":"Miadili","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Xiaoman","family":"Li","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Yan","family":"Zhang","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Danping","family":"Ruan","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Wei","family":"Liu","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Jianfei","family":"Zhang","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Yiming","family":"Gao","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"1965","published-online":{"date-parts":[[2025,2,25]]},"reference":[{"key":"B1","doi-asserted-by":"publisher","first-page":"1359","DOI":"10.1016\/j.jds.2024.03.011","article-title":"Robot-assisted dental implant surgery procedure: a literature review","volume":"19","author":"Bahrami","year":"2024","journal-title":"J. Dent. Sci."},{"key":"B2","doi-asserted-by":"publisher","first-page":"269","DOI":"10.1016\/j.joms.2015.09.022","article-title":"Static or dynamic navigation for implant placement-choosing the method of guidance","volume":"74","author":"Block","year":"2016","journal-title":"J. Oral Maxillofac. Surg."},{"key":"B3","doi-asserted-by":"publisher","first-page":"639","DOI":"10.1016\/j.prosdent.2020.12.048","article-title":"Accuracy of haptic robotic guidance of dental implant surgery for completely edentulous arches","volume":"128","author":"Bolding","year":"2022","journal-title":"J. Prosthet. Dent."},{"key":"B4","doi-asserted-by":"publisher","first-page":"495","DOI":"10.1111\/j.1600-0501.2005.01133.x","article-title":"Accuracy of image-guided implantology","volume":"16","author":"Brief","year":"2005","journal-title":"Clin. Oral Implants Res."},{"key":"B5","doi-asserted-by":"publisher","first-page":"973","DOI":"10.1111\/clr.14104","article-title":"Accuracy of immediate dental implant placement with task-autonomous robotic system and navigation system: an in vitro study","volume":"35","author":"Chen","year":"2024","journal-title":"Clin. Oral Implants Res."},{"key":"B6","doi-asserted-by":"publisher","first-page":"1917","DOI":"10.1097\/SCS.0b013e3181f4b1a0","article-title":"Computer-guided surgery in implantology: review of basic concepts","volume":"21","author":"de Almeida","year":"2010","journal-title":"J. Craniofac Surg."},{"key":"B7","doi-asserted-by":"publisher","first-page":"121","DOI":"10.1111\/prd.12175","article-title":"Current state of the art of computer-guided implant surgery","volume":"73","author":"D'Haese","year":"2017","journal-title":"Periodontol"},{"key":"B8","doi-asserted-by":"publisher","first-page":"5901","DOI":"10.1118\/1.4750054","article-title":"Relationship between x-ray illumination field size and flat field intensity and its impacts on x-ray imaging","volume":"39","author":"Dong","year":"2012","journal-title":"Med. Phys."},{"key":"B9","doi-asserted-by":"publisher","first-page":"107","DOI":"10.1111\/cid.12261","article-title":"Relationship between the CT value and cortical bone thickness at implant recipient sites and primary implant stability with comparison of different implant types","volume":"18","author":"Howashi","year":"2016","journal-title":"Clin. Implant Dent. Relat. Res."},{"key":"B10","doi-asserted-by":"publisher","first-page":"3887","DOI":"10.1038\/s41598-024-54529-4","article-title":"Improving the accuracy of bone mineral density using a multisource CBCT","volume":"14","author":"Hu","year":"2024","journal-title":"Sci. Rep."},{"key":"B11","doi-asserted-by":"publisher","first-page":"1797","DOI":"10.1007\/s11548-024-03161-8","article-title":"Development and validation of a collaborative robotic platform based on monocular vision for oral surgery: an in vitro study","volume":"19","author":"Huang","year":"2024","journal-title":"Int. J. Comput. Assist. Radiol. Surg."},{"key":"B12","doi-asserted-by":"publisher","first-page":"533","DOI":"10.1016\/j.joen.2024.01.012","article-title":"Robot-assisted and haptic-guided endodontic surgery: a case report","volume":"50","author":"Isufi","year":"2024","journal-title":"J. Endod."},{"key":"B13","doi-asserted-by":"publisher","first-page":"2479","DOI":"10.1007\/s00784-021-03833-8","article-title":"Accuracy assessment of dynamic computer-aided implant placement: a systematic review and meta-analysis","volume":"25","author":"Jorba-Garc\u00eda","year":"2021","journal-title":"Clin. Oral Investig."},{"key":"B14","first-page":"39","article-title":"Bone classification, training keys to implant success","volume":"8","author":"Misch","year":"1989","journal-title":"Dent. Today"},{"key":"B15","first-page":"23","article-title":"Density of bone: effect on treatment plans, surgical approach, healing, and progressive boen loading","volume":"6","author":"Misch","year":"1990","journal-title":"Int. J. Oral Implantol."},{"key":"B16","doi-asserted-by":"publisher","first-page":"1653","DOI":"10.1016\/j.compbiomed.2013.07.029","article-title":"Factors affecting accuracy of implant placement with mucosa-supported stereolithographic surgical guides in edentulous mandibles","volume":"43","author":"Ochi","year":"2013","journal-title":"Comput. Biol. Med."},{"key":"B17","doi-asserted-by":"publisher","first-page":"1755","DOI":"10.1097\/SCS.0b013e31822e6305","article-title":"Correlation between bone density and angular deviation of implants placed using CT-generated surgical guides","volume":"22","author":"Ozan","year":"2011","journal-title":"J. Craniofac Surg."},{"key":"B18","doi-asserted-by":"publisher","first-page":"955","DOI":"10.11607\/jomi.8176","article-title":"Effects of drilling protocol and bone density on the stability of implants according to different macrogeometries of the implant used: results of an in vitro study","volume":"35","author":"P\u00e9rez-Pevida","year":"2020","journal-title":"Int. J. Oral Maxillofac. Implants"},{"key":"B19","doi-asserted-by":"publisher","first-page":"62","DOI":"10.1186\/s40729-020-00249-z","article-title":"Influence of bone condition on implant placement accuracy with computer-guided surgery","volume":"6","author":"Putra","year":"2020","journal-title":"Int. J. Implant Dent."},{"key":"B20","doi-asserted-by":"publisher","first-page":"24","DOI":"10.1111\/jcpe.13893","article-title":"Improved positional accuracy of dental implant placement using a haptic and machine-vision-controlled collaborative surgery robot: a pilot randomized controlled trial","volume":"51","author":"Shi","year":"2024","journal-title":"J. Clin. Periodontol."},{"key":"B21","doi-asserted-by":"publisher","first-page":"104748","DOI":"10.1016\/j.jdent.2023.104748","article-title":"Advancing accuracy in guided implant placement: a comprehensive meta-analysis","volume":"139","author":"Tak\u00e1cs","year":"2023","journal-title":"J. Dent."},{"key":"B22","doi-asserted-by":"publisher","first-page":"1217","DOI":"10.1016\/j.dental.2021.06.001","article-title":"Robot technology in dentistry, part one of a systematic review: literature characteristics","volume":"37","author":"van Riet","year":"2021","journal-title":"Dent. Mater"},{"key":"B23","doi-asserted-by":"publisher","first-page":"880","DOI":"10.1016\/j.ijom.2013.03.001","article-title":"Influence of maxillomandibular positioning in cone beam computed tomography for implant planning","volume":"42","author":"Visconti","year":"2013","journal-title":"Int. J. Oral Maxillofac. Surg."},{"key":"B24","doi-asserted-by":"publisher","first-page":"105034","DOI":"10.1016\/j.jdent.2024.105034","article-title":"Robot-assisted surgery for dental implant placement: a narrative review","volume":"146","author":"Wang","year":"","journal-title":"J. Dent."},{"key":"B25","doi-asserted-by":"publisher","first-page":"350","DOI":"10.1111\/clr.14232","article-title":"Effect of implant shape and length on the accuracy of robot-assisted immediate implant surgery: an in vitro study","volume":"35","author":"Wang","year":"","journal-title":"Clin. Oral Implants Res."},{"key":"B26","doi-asserted-by":"publisher","first-page":"598","DOI":"10.1111\/clr.14255","article-title":"Accuracy of robotic surgery for dental implant placement: a systematic review and meta-analysis","volume":"35","author":"Wu","year":"2024","journal-title":"Clin. Oral Implants Res."},{"key":"B27","doi-asserted-by":"publisher","first-page":"1149","DOI":"10.1111\/cid.13375","article-title":"Comparative analysis of dental implant placement accuracy: semi-active robotic versus free-hand techniques: a randomized controlled clinical trial","volume":"26","author":"Yang","year":"2024","journal-title":"Clin. Implant Dent. Relat. Res."}],"container-title":["Frontiers in Bioengineering and Biotechnology"],"original-title":[],"link":[{"URL":"https:\/\/www.frontiersin.org\/articles\/10.3389\/fbioe.2025.1536957\/full","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,2,25]],"date-time":"2025-02-25T06:56:27Z","timestamp":1740466587000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.frontiersin.org\/articles\/10.3389\/fbioe.2025.1536957\/full"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2025,2,25]]},"references-count":27,"alternative-id":["10.3389\/fbioe.2025.1536957"],"URL":"https:\/\/doi.org\/10.3389\/fbioe.2025.1536957","relation":{},"ISSN":["2296-4185"],"issn-type":[{"value":"2296-4185","type":"electronic"}],"subject":[],"published":{"date-parts":[[2025,2,25]]},"article-number":"1536957"}}