{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,9,18]],"date-time":"2026-09-18T19:54:24Z","timestamp":1789761264178,"version":"4.0.1"},"reference-count":13,"publisher":"Frontiers Media SA","license":[{"start":{"date-parts":[[2025,11,7]],"date-time":"2025-11-07T00:00:00Z","timestamp":1762473600000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"content-domain":{"domain":["frontiersin.org"],"crossmark-restriction":true},"short-container-title":["Front. Bioeng. Biotechnol."],"abstract":"<jats:sec>\n                    <jats:title>Background<\/jats:title>\n                    <jats:p>Tibial plateau bone defect represents a pivotal challenge in revision knee arthroplasty, where suboptimal extension stem design predisposes to stress concentration and subsequent prosthesis loosening. Physiological posterior tibial slope (5\u00b0\u20137\u00b0) optimizes knee biomechanics, yet bone defects disrupt proximal tibial anatomy, rendering traditional stems biomechanically incompatible. The synergistic optimization of \u201cdefect severity-stem length-posterior tilt angle\u201d remains underexplored.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Methods<\/jats:title>\n                    <jats:p>A finite element model was constructed incorporating three defect areas (20%, 40%, 60%), two stem lengths (40mm, 80\u00a0mm), and five posterior tilt angles (0\u00b0\u201310\u00b0), yielding 30 experimental cohorts. Under 2450N axial loading, stress distribution (cortical\/cancellous bone, prosthesis, sleeve) and bone-prosthesis micromotion were quantitatively evaluated.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Results<\/jats:title>\n                    <jats:p>All micromotion magnitudes remained below the 150\u00a0\u03bcm osseointegration threshold. In 20% defects, 40\u00a0mm stems with \u22647\u00b0 tilt mitigated cortical stress concentration; 80\u00a0mm stems showed lower micromotion but excessive cancellous stress at 10\u00b0 tilt. In 40%\/60% defects, increasing tilt reduced micromotion (37.3%\/45.3% reduction), with 80\u00a0mm stems exhibiting superior stability. Extreme tilt (10\u00b0) in long stems exacerbated cortical stress and prosthesis load.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Conclusion<\/jats:title>\n                    <jats:p>\n                      Based on the finite element analysis results, this study provides a hypothetical reference for the selection of posterior tilt angles of extension stems in the repair of tibial plateau defects: a posterior tilt angle of \u22647\u00b0 is suggested for 20% defects when using a 40\u00a0mm stem; 7\u00b0\u201310\u00b0 for 40% defects when using an 80\u00a0mm stem; and 5\u00b0\u20137\u00b0 for 60% defects when using an 80\u00a0mm stem. This preliminary biomechanical finding offers a basis for exploring personalized implant design, while the realization of precision-based repair and improved prosthesis longevity requires further validation by multi-center clinical data, diverse patient anatomical models (e.g., differences in tibial size and medullary canal morphology), and\n                      <jats:italic>in vitro<\/jats:italic>\n                      experiments.These data need to be verified through multi-center clinical data and\n                      <jats:italic>in vitro<\/jats:italic>\n                      artificial bone experiments.\n                    <\/jats:p>\n                  <\/jats:sec>","DOI":"10.3389\/fbioe.2025.1688915","type":"journal-article","created":{"date-parts":[[2025,11,7]],"date-time":"2025-11-07T06:24:12Z","timestamp":1762496652000},"update-policy":"https:\/\/doi.org\/10.3389\/crossmark-policy","source":"Crossref","is-referenced-by-count":1,"title":["Biomechanical optimization study of posterior tilt extension stems in the repair of tibial plateau bone defects"],"prefix":"10.3389","volume":"13","author":[{"given":"Yong","family":"Wang","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Ruihu","family":"Hao","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Lin","family":"Guo","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Xiaoyu","family":"Zhou","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"1965","published-online":{"date-parts":[[2025,11,7]]},"reference":[{"key":"B1","doi-asserted-by":"publisher","first-page":"e14","DOI":"10.2106\/JBJS.ST.18.00038","article-title":"Management of bone defects in revision total knee arthroplasty with use of a stepped, porous-coated metaphyseal sleeve","volume":"9","author":"Angerame","year":"2019","journal-title":"JBJS Essent. Surg. Tech."},{"key":"B13","doi-asserted-by":"publisher","first-page":"2550","DOI":"10.1007\/s00167-015-3630-8","article-title":"All-polyethylene tibial components generate higher stress and micromotions than metal-backed tibial components in total knee arthroplasty","volume":"24","author":"Brihault","year":"2016","journal-title":"Knee Surg. Sports Traumatol. Arthrosc."},{"key":"B2","doi-asserted-by":"publisher","first-page":"11","DOI":"10.1186\/s42836-021-00070-y","article-title":"Effects of posterior tibial slope on the mid-term results of medial unicompartmental knee arthroplasty","volume":"3","author":"Chen","year":"2021","journal-title":"Arthroplasty"},{"key":"B3","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1016\/j.jor.2019.11.021","article-title":"Finite element assessment of metaphyseal sleeves in total knee arthroplasty","volume":"19","author":"Frehill","year":"2019","journal-title":"J. Orthop."},{"key":"B4","doi-asserted-by":"publisher","first-page":"e0177285","DOI":"10.1371\/journal.pone.0177285","article-title":"Tibial revision knee arthroplasty with metaphyseal sleeves: the effect of stems on implant fixation and bone flexibility","volume":"12","author":"Nadorf","year":"2017","journal-title":"PLoS One"},{"key":"B5","doi-asserted-by":"publisher","first-page":"108","DOI":"10.1097\/00003086-198607000-00023","article-title":"Observations on the effect of movement on bone ingrowth into porous-surfaced implants","volume":"208","author":"Pilliar","year":"1986","journal-title":"Clin. Orthop. Relat. Res."},{"key":"B6","doi-asserted-by":"publisher","first-page":"1596","DOI":"10.1002\/jor.24710","article-title":"Joint line elevation and tibial slope are associated with increased polyethylene wear in cruciate-retaining total knee replacement","volume":"38","author":"Pourzal","year":"2020","journal-title":"J. Orthop. Res."},{"key":"B7","doi-asserted-by":"publisher","first-page":"e0184361","DOI":"10.1371\/journal.pone.0184361","article-title":"Biomechanical evaluation of tibial bone adaptation after revision total knee arthroplasty: a comparison of different implant systems","volume":"12","author":"Quilez","year":"2017","journal-title":"PLoS One"},{"key":"B8","doi-asserted-by":"publisher","first-page":"e0156282","DOI":"10.1371\/journal.pone.0156282","article-title":"Knee joint loads and surrounding muscle forces during stair ascent in patients with total knee replacement","volume":"11","author":"Rasnick","year":"2016","journal-title":"PLoS One"},{"key":"B9","doi-asserted-by":"publisher","first-page":"521","DOI":"10.1177\/2041303310395074","article-title":"Load transfer in the proximal tibia following implantation with a unicompartmental knee replacement: a static snapshot","volume":"225","author":"Simpson","year":"2011","journal-title":"J. Eng. Med."},{"key":"B10","doi-asserted-by":"publisher","first-page":"S51","DOI":"10.1016\/s0883-5403(88)80009-3","article-title":"The effect of posterior tibial slope on knee stability after ortholoc total knee arthroplasty","volume":"3","author":"Whiteside","year":"1988","journal-title":"J. arthroplasty"},{"key":"B11","doi-asserted-by":"publisher","first-page":"909","DOI":"10.1186\/s13018-023-04222-5","article-title":"The effect of different posterior inclinations of tibial component on tibiofemoral contact pressures after unicompartmental knee arthroplasty","volume":"18","author":"Yuan","year":"2023","journal-title":"J. Orthop. Surg. Res."},{"key":"B12","doi-asserted-by":"publisher","first-page":"3718705","DOI":"10.1155\/2020\/3718705","article-title":"Finite element assessment of the screw and cement technique in total knee arthroplasty","volume":"2020","author":"Zheng","year":"2020","journal-title":"Biomed. Res. Int."}],"container-title":["Frontiers in Bioengineering and Biotechnology"],"original-title":[],"link":[{"URL":"https:\/\/www.frontiersin.org\/articles\/10.3389\/fbioe.2025.1688915\/full","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,11,7]],"date-time":"2025-11-07T06:24:12Z","timestamp":1762496652000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.frontiersin.org\/articles\/10.3389\/fbioe.2025.1688915\/full"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2025,11,7]]},"references-count":13,"alternative-id":["10.3389\/fbioe.2025.1688915"],"URL":"https:\/\/doi.org\/10.3389\/fbioe.2025.1688915","relation":{},"ISSN":["2296-4185"],"issn-type":[{"value":"2296-4185","type":"electronic"}],"subject":[],"published":{"date-parts":[[2025,11,7]]},"article-number":"1688915"}}